SPECIFICATIONS OF CLUSTER SERVER CLUSTER SERVER: Processor - Intel XEON 8 Core E5-2620 V4 Processor ( 2.GHz ) Max Turbo Frequency : 3.0GHz No. of Processors (Std/Max) - 2/2 Cache - 20MB SmartCache Chipset - Intel C62 Memory - 64GB TruDDR4 Memory (2Rx4,.2V) PC4-9200 CL7 2400MHz LP RDIMM Memory Total Memory / Slots - 24 Slots With RDIMMs : Up to 768 GB with 24x 32 GB RDIMMs and two processors With LRDIMMs : Up to.5 TB with 24x 64 GB LRDIMMs and two processors Hard Disk - 4 x 600 GB 0K 2.5" hot swap SAS disks RAID Controller - Integrated RAID 0, and 0 Bays - Up to 28x 2.5 SAS/SATA hot-swap drive bays (24 front, 4 rear) Expansion Slots - Nine PCI Slots for Expansion Network - Four Integrated RJ-45 Gigabit Ethernet 000BASE-T ports Additional Intel I350-T4 4xGbE BaseT Adapter Form Factor - 2U rackmount Optical Drive - 9.5mm Ultra-Slim SATA Multi-Burner Graphics - Matrox G200eR2 with 6 MB memory integrated into the IMM2.. Maximum resolution is 600x200 at 75 Hz with 6 M colors. Ports - Front : x USB 2.0 / Rear : 2 x USB 3.0, x DB-5 video, x RJ-45 systems management, 4x RJ-45 GbE network ports. Optional x DB-9 serial port. Internal: x USB 2.0 (for hypervisor), x SD Media Adapter slot (for hypervisor). SD Media Support - Support for x SD Media Adapter with redundant SD media (for embedded hypervisor). Systems Management - UEFI, Integrated Management Module II (IMM2.) based on Renesas SH7758, Predictive Failure Analysis, light path diagnostics, Automatic Server Restart, ToolsCenter, XClarity Administrator, XClarity Energy Manager. Power Supply - Up to two redundant hot-swap 550W High Efficiency Platinum AC power supplies Cooling Fans - Calibrated Vectored Cooling with up to six redundant hot-swap fans (four standard, additional two fans with the second processor); two fan zones with N+ fan redundancy; each fan has one motor. Operating Systems / Virtualization Software Supported - Microsoft Windows Server 206, 202 R2, 202, 2008 R2; Red Hat Enterprise Linux 6, 7; SUSE Linux Enterprise Server, 2; VMware ESXi 5., 5.5, 6.0, 6.5 2 Memory (Optional) - Additional 32GB TruDDR4 Memory (2Rx4,.2V) PC4-9200 CL7 2400MHz LP RDIMM Memory
SPECIFICATIONS OF ACTIVE DIRECTORY SERVER ACTIVE DIRECTORY SERVER: Processor - Intel Quad Core Xeon E3-225 v5 Processor (3.3 GHz) Max Turbo Frequency 3.7 GHz Cache - 8MB L3 Chipset - Intel C236 Chipset Memory - 8GB DDR4 UDIMMs, 233 MHz Memory expandable upto 64GB Storage - 2 X TB SATA 7.2Krpm Hard Drive Internal Storage - 4 LFF SATA HDD cage PCI-Express Slots - 4 PCIe 3.0 slots Optical Drive - DVDRW Graphics - SVGA / Matrox G200e intehrated in IMM on Systemboard / 6MB DDR2-250 MHz SDRAM std/max/ 32-bit 33MHz PCI 2.2 Network Controller - Intel Ethernet Connection I29-LM Standard Network - HP Ethernet Gb 2P 332T Adapter PIC Storage Controller - Intel Rapid Storage Technology SATA RAID Fans - non hot plug, non-redundant Management - Intel Active Management Technology (Intel AMT.0) Form Factor - Single Socket Tower Server, 4U Power Supply - 300W NHP PSU 85% Efficiency Input Devices - USB Keyboard & Mouse OS Support - Should support Microsoft windows 206, Red Hat Enterprise Linux and VMware VSphere (ESXi)
DETAILS OF REQUIRED SOFTWARE Vendor's Proposal(Must specify exact specification) Operating System Microsoft Windows Server 206 Standard Edition 6 Core Lic 3 Microsoft Windows Server 206 Client Access License 5 Backup Microsoft System Center 206 Standard Edition 8 Core Lic
SPECIFICATIONS OF NAS NAS: CPU Memory Hard Disk Hard Drive Bays Dual Core.4GHz GB DDR3 2 x 2TB S-ATA Hard Disk 4 Hot Swappable External Ports USB 3.0 ports x 3 Supported RAID type Hybrid RAID, Basic, JBOD, RAID 0, RAID, RAID 5, RAID 6, RAID 0 Network Gigabit (RJ-45) x 2 Networking protocols File system CIFS, AFP, NFS, FTP, WebDAV, CalDAV, iscsi, Telnet, SSH, SNMP, VPN (PPTP, OpenVPN, L2TP) Internal : ext4 / External: ext4, ext3, FAT, NTFS, HFS+ (read only) Storage management Maximum single volume size: 6TB, Maximum internal volume: 256, File sharing capability Directory service Security Backup solutions Storage Analyzer Security Advisor Warranty Maximum iscsi Target: 0, Maximum iscsi LUN: 0 Maximum user account: 2048, Maximum group: 256, Maximum shared folder: 256, Maximum concurrent CIFS/AFP/FTP/File Station connection: 256 Windows AD Integration: Domain Users login via Samba (CIFS)/AFP/ FTP/File Station, LDAP integration FTP over SSL/TLS, IP auto-block, firewall, encrypted network backup over Rsync, HTTPS connection Network backup; local backup; desktop backup; configuration backup; OS X Time Machine; backup data to public cloud; shared folder sync - maximum task number: 4 Volume and quota usage, total size of files, volume usage and trends based on past usage, size of shared folders, largest/most/least frequently modified files Malware detection/removal, user account/password, network, system-related security scan One Year
SPECIFICATIONS OF SERVER RACK SERVER RACK: Size 42U, 800 x 000mm Form Factor Floor Mount with Caster Wheels Frame Steel Front Door Single Perforated Metal Door with Lock Rear Door Dual Perforated Metal Door with Lock Fixed Shelves 2 Cooling Fans Four PDU 0 Sockets Power Distribution Unit ( C3 Sockets ) Captive Hardware Cable Organiser Horizontal Cable Organizer 5 Packets 2 Nos of Vertical Cable Organizer Min 3 Nos
SPECIFICATIONS OF ONLINE UPS Product Capacity Main Feature Input Rating 5KVA Voltage Range 65~285V Frequency Range 50Hz +/-0% Power Factor > 0.95 Phase Battery Voltage 5KVA UPS True On Line Double Conversion Design Output Isolation Transformer Wide input voltage range user friendly digital LCD Display Cold start function High Crest Factor Circuit Design Advanced Battery Management Improved Input Power Fctor Single Phase 20V Output Crest Factor 3: Voltage Range 220 V / 230 V / 240 V Power Factor 0.7 Standard Overload Capacity 25% of rated load last for 60 secs; 50% of rated load last for sec Output Distorion THD <2% (Linear Load) and <4% (Non Linear Load) Other Features LCD Display indicating (input voltage, output voltage, input frequency, Display Panel output frequency, load capacity, battery voltage) LED Indication: Mains, AC Mode, DC Mode, Low Battery, Overload Charger Capacity 0 Ampere Efficiency > 9% Back up Time Up To 2 Hrs
SCOPE OF WORK FOR INSTALLATION AND IMPLEMENTATION S.N Scope of Work The solution provider shall design new virualization environment and to perform necessary migration from current platform for new configuration 2 Server optimization, rack mount and installation of hypervisor Migrating of existing OS, data and applications (physical Machine and VMs) to new 3 virtualized environment plan and design exisiting data migration without any downtime 4 Plan and design or configuring virtual machine backup and replication Setup and configuration Hypervisor, Management Server and Virtual Machine as 5 per the requirements 6 Plan, design and implement virtualization infrastructure 7 Convert of current physical machine to new Virtual Machine 8 Configuration of Virtualization replication 9 Virtualization host management and monitoring 0 Configuring networking for virtualization and physical environment Necessary VLAN and network configuration for the VM hosts, routing between VM hosts Bidder should have local certified professional for proposed Solutions who shall 2 deploy the solution and provide support to NB Insurance. Complete training and knowledge transfer of supplied server, virtualization for 3 NB Insurance IT Staff. Complete resume of working team including level of support providing task 4 assignment for this project