Similar documents
SITRANS F C. Transmitter MASS 6000 Ex d compact/remote 3/195

Flow Measurement SITRANS F C

SITRANS F flowmeters. SITRANS F C Transmitter MASS 6000 for 19" insert/19" wall mounting. 4/134 Siemens FI

Flow Measurement SITRANS F M. Transmitter MAG 6000 I/6000 I Ex de. 3/46 Siemens FI

SITRANS F flowmeters. SITRANS F C System information MASSFLO coriolis mass flowmeters. 4/110 Siemens FI Overview

Flow Measurement SITRANS F M. Transmitter MAG 5000/ /34 Siemens FI Overview

Flow Measurement SITRANS F US Inline

Flow Measurement SITRANS F C

Flow Measurement SITRANS F US Inline

Flow Measurement SITRANS F M

Level Measurement Continuous level measurement - Ultrasonic transmitters

Flow Measurement SITRANS F M

PN DN FIG. 660D-BATT+670D-BATT 661D-BATT+670D-BATT SISTEMI DI MISURA / SYSTEM MEASURE / SYSTEMES DE KAT KAT-06...

Measurement. SITRANS F US Inline. Transmitter FUS080/FUE080 4/221

RHE26. Rack/Panel/DIN Rail Mount Multifunction Coriolis Flow Transmitter

5 Fieldbus Technology

Level Measurement Continuous level measurement - Ultrasonic transmitters

Flow Measurement SITRANS F US Clamp-on

Assembly MAU. MUX 4 Channels 8 Channels Zone 1

RHE21. Exd / Exd(e) Extreme Environment Multifunction Coriolis Flow Transmitter

Micro Motion Model 2200S 2-Wire Transmitter with MVD Technology

RHE21. Exd / Exd(e) Extreme Environment Multifunction Coriolis Flow Transmitter

Supplementary Components WirelessHART products

C-Flow Coriolis Mass Flow Meter

RHE27. Rack/Panel Mount Multifunction Coriolis Flow Transmitter

VersaFlow TWC 9000/TWC 010 Coriolis Mass Flow Converter Technical Datasheet. Specification. The high-performance solution. Industries.

RHE26. Rack/Panel Mount Multifunction Coriolis Flow Transmitter

Siemens AG Continuous level measurement - Radar transmitters. Configuration. Mounting on a nozzle. Installation min.

SYSTEM COMPONENTS SYSTEM COMPONENTS MODULES

RHE16. Compact Multifunction Coriolis Flow Meter Transmitter. Features. Applications. Benefits

Assembly MAU. MUX 4 Channels 8 Channels Zone 1

HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters

RHE27 Rack/Panel Mount Multifunction Coriolis Flow Transmitter

TRICOR Series TCM Coriolis Mass Flow Meters

Level Measurement Continuous level measurement - Ultrasonic controllers

FOR LIQUIDS AND SOLIDS

HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters

Digital Output Module 8-Channel Version for Zone 1 Series 9475/

Online data sheet. FLOWSIC100 Flare MASS FLOW MEASURING DEVICES

SITRANS F C MASSFLO. MASS flowmeters Transmitter type MASS 6000 Ex-d sensor type MASS 2100 compact or remote mounted. Operating manual *083R9506*

4 â Active barrier RN221N with optional HART diagnosis. Technical Information

Safety instructions. IECEx TUN Ex ia IIC T6 Gb

ExCos-P Pressure sensor 20 Pa Pa

Level Measurement Continuous level measurement - Ultrasonic controllers

RHE28. Field and Wall Mount Multifunction Coriolis Flow Transmitter

Grounding Systems / Ground Monitoring Device Series 8146/5075 and 8125/5071

Ethernet CPU Module & Power Module for Zone 1 / Div. 1 Series 9441/12 and 9444/12

Micro Motion Series 1000 and 2000 Transmitters with MVD Technology

Isolating repeater IRU 420

HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters

NIVOSWITCH VIBRATING FORK LEVEL SWITCHES

Digital Output Module 8-Channel Version for Zone 2 Series 9475/

SITRANS F flowmeters SITRANS F US. SITRANS FUE950 energy calculator. 4/240 Siemens FI

Level Measurement Continuous level measurement - Ultrasonic controllers

Flow Measurement SITRANS F US Clamp-on

Reed sensor For bypass level indicators Model BLR

SITRANS F flowmeters SITRANS F US. Flowmeter SONO 3300/FUS060 4/177. Technical specifications. Overview

SITRANS T measuring instruments for temperature

Level Measurement Continuous level measurement Ultrasonic controllers

4 Remote I/O. Digital Output Module 8-Channel Version Type 9475/ from Rev. F

RHE16. Compact Multifunction Coriolis Flow Meter Transmitter. Features. Applications. Benefits

Digital Output Module 4-Channel Version for Zone 1 Series 9475/

Flow Measurement SITRANS F US Inline

4 Remote I/O. Analog Output Module HART Ex i / I.S. Outputs, 8 Channels Series 9466/12

Flow Measurement SITRANS F C

PI-EX-ME-2NAM/COC-24VDC

SITRANS F flowmeters SITRANS F US

Continuous level measurement Ultrasonic controllers

Dräger Polytron 8200 Stationary gas detector (CatEx)

Grounding Monitoring Device Series 8485

Digital Output Module 4-Channel Version for Zone 1 Series 9475/

Series 255. Flow Averaging Transmitter TECHNICAL SPECIFICATIONS

Capacitance level switches LS 210 LS 220

SITRANS F. Electromagnetic Flowmeters. MAG 6000 I / MAG 6000 I Ex de transmitter. Operating Instructions. Answers for industry.

Flow Measurement SITRANS F US Inline

Digital Output Module 8-Channel Version for Zone 2 Series 9475/

PI-EX-ME-2NAM/COC-120VAC

Flow Measurement SITRANS F US Clamp-on

Continuous level measurement Radar transmitters

100mm Process Indicator Recorder

FieldIT Multi Barrier NMB204/NMB204-EX (MB 204/MB 204-Ex)

Flow Measurement SITRANS F C

Level Measurement Continuous level measurement Ultrasonic controllers

Assembly. Front view. LED yellow: Relay output. LED red: LB/SC Power Rail

Flow Measurement SITRANS F US Inline

Intrinsically Safe Barriers

InCos-P Pressure sensor 20 Pa Pa

Flow simulation system PROline FieldCheck

FlexBar 3501 Pressure Transmitter

UFD 5. Display for ALTOSONIC 5. Technical Datasheet. Configurable display for ALTOSONIC 5 Easy installation Durable design

EElectronic Devices and Systems. EK-87 Electronic Volume Corrector. This product is discontinued!

FB-6SP and FB-12SP. Block device couplers. Data sheet 3177_en_A. 2 Features. 1 Description

Technical Information RIA15

Absolute Rotary Encoder EXAG Explosion Proof. Profibus-DP

FLEX Ex Spring Clamp Terminal Base

4 Remote I/O. Digital Output Module 8-Channel Version Series 9475/ from Rev. F

TRANSMITTERS. HygroFlex & HygroClip-EX. Applications. Highlights

Assembly. Front view. LED yellow/red: Status output Ι/ Fault signal Function. Switch Power Rail

Electro-Magnetic Flowmeters Converters

CPU module for zone 2 Series 9442/35

Transcription:

Overview MASS 6 is based on digital signal processing technology engineered for high performance, fast flow step response, fast batching applications, high immunity against process noise, easy to install, commission and maintain. The MASS 6 transmitter delivers true multiparameter measurements i.e.: Mass flow, volume flow, density, temperature and fraction flow. The MASS 6 Ex d transmitter is manufactured in stainless steel (AISI 16L/1.444) and able to withstand harsh installation conditions in hazardous applications within the process and chemical industry. The conservative choice of material guarantees the user a low cost of ownership and a long trouble-free lifetime. The Ex d can be compact mounted on all sensors of type MASS 21 DI to DI 15, and can be used in remote version for all types of MASS 21. MASS 6 Ex d cannot be combined with MC2 sensors. Benefits Fully stainless steel flameproof Ex d enclosure, ensuring optimum cost of ownership Intrinsically safe keypad and display directly programmable in hazardous area Ex-approved transmitter which can be mounted in hazardous area Zone 1 or Zone 2. Sensor and transmitter interface intrinsically safe Ex ia IIC Exchange of transmitter directly in hazardous area without shut-down of process pipe line due to ia IIC sensor/transmitter interface. Dedicated mass flow chip with the latest ASIC technology Fast batching and flow step response with an update rate of true Hz Superior noise immunity due to a DFT (Discrete Fourier Transformation) algorithm Front end resolution better than.5 ns improves zero point stability and enhances dynamic turn-down ratio on flow and density accuracy. Advanced diagnosis and service menu enhances troubleshooting and meter verification. Built-in batch controller with compensation and monitoring comprising 2 built-in totalizers Multi-parameter outputs, individual configurable for mass flow, volume flow, density, temperature or fraction flow such as Brix or Plato 1 current output, 1 frequency/pulse and 1 relay as standard output Current output can be selected as passive or active output Digital input for batch-control, remote zero adjust or forced output mode All outputs can be forced to preset value for simulation, verification or calibration purposes. User-configurable operation menu with password protection - lines, 2 characters display in 11 languages - Self-explaining error handling/log in text format - Keypad can be used for controlling batch as start/stop/hold/reset SENSORPROM technology automatically configures transmitter at start-up providing: - Factory pre-programming with calibration data, pipe size, sensor type, output settings - Any values or settings changed by users are stored automatically - Automatically re-programming any new transmitter without loss of accuracy - Transmitter replacement in less than 5 minutes. True "plug & play" Fraction flow computation based on a rd-order algorithm matching all applications USM II platform enables fitting of add-on bus modules without loss of functionality: - All modules can be fitted as true "plug & play" - Module and transmitter automatically configured through the SENSORPROM Installation of the transmitter to the sensor is simple "plug & play" via the sensor pedestal. Application mass flowmeters are suitable for all applications within the entire process industry where there is a demand for accurate flow measurement in hazardous area. The meter can measure both liquids and gases. The main applications for the MASS 6 Ex d transmitter can be found in: Chemical process industry Pharmaceutical industries Automotive industry Oil and gas industry Power generation and utility industry Design The transmitter is designed in an Ex d compact stainless steel enclosure which can be compact mounted on the MASS 21 sensor range DI to DI 15, and remote mounted for the entire sensor series except MC2. The MASS 6 Ex d is available as standard with 1 current, 1 frequency/pulse and 1 relay output and can be fitted with addon modules for bus communication. Flameproof d enclosure Enclosure stainless steel, IP67/NEMA 6 as compact and IP65 as remote Supply voltage 24 V AC/DC MASS 6 Ex d is Ex-approved together with all MASS 21 sensors, but can not be used together with MC2 Ex versions /16 Siemens FI 1 216

Function The following functions are available: Mass flow rate, volume flow rate, density, temperature, fraction flow 1 current output, 1 frequency/pulse output, 1 relay output, 1 digital input All outputs can be individually configured with mass, volume, density etc. 2 built-in totalizers which can count positive, negative or net Low flow cut-off Density cut-off or empty pipe cut-off, adjustable Flow direction Error system consisting of error-log, error pending menu Operating time Uni/bidirectional flow measurement Limit switches with 1 or 2 limits, programmable for flow, density or temperature Noise filter setting for optimization of measurement performance under non-ideal application conditions Full batch controller Automatic zero adjustment menu, with zero point evaluation feed back Full service menu for effective and straight forward application and meter troubleshooting Technical specifications Measurement of Current output Current Time constant Current characteristics Digital output Frequency Time constant Passive Relay Type Functionality Mass flow [kg/s (lb/min)], volume flow [l/s (gpm)], fraction [%], Brix, density [kg/m (lb/ft )], temperature [ C ( F)] Classified Ex ia, selectable as active or passive outputs. Default setting is active mode.... 2 ma or 4... 2 ma < 5.... s adjustable U o = 24 V, I o = 82 ma, P o =.5 W, C o = 125 nf, L o = 2.5 mh U i = V, I i = 1 ma, P i =.75 W, C i = 52 nf, L i = 1 H... 1 khz, 5 % duty cycle.1... s adjustable 6... V DC, max. 11 ma, 1 K R load 1 k U i = V, I i = 1 ma, P i =.75 W, C i = 52 nf, L i = 1 H Change-over relay V/1 ma Error level, error number, limit, direction U i = V, I i = 1 ma, P i =.75 W, C i = nf, L i = mh Digital input Functionality Galvanic isolation Cut-off Low-flow Empty pipe 11... V DC (R i = 1.6 k Start/hold/continue batch, zero point adjust, reset totalizer 1/2, force output, freeze output U i = V, I i =.45 ma, P i =.1 W, C i = nf, L i = mh All inputs and outputs are galvanically isolated. Isolation voltage: 5 V to supply 5 V between outputs.... % of maximum flow Detection of empty sensor Density... 2. g/cm Totalizer Display Zero point adjustment Ambient temperature Operation Storage Communication PROFIBUS PA Passive mode Passive mode Enclosure Two eight-digit counters for forward, net or reverse flow Background illumination with alphanumerical text, 2 characters to indicate flow rate, totalized values, settings and faults. Time constant as current output Reverse flow indicated by negative sign Via keypad or remote via digital input -2... +5 C (-4... +122 F) -4... +7 C (-4... +158 F) (Humidity max. 5 %) Add-on modules:, PROFIBUS PA, U o = 6.88 V, I o = ma, P o =.57 W, C o = 2 nf, L o = 1 H U i = 1 V, I i = 2 ma, P i =.5 W, C i = nf, L i = H U i = 17.5 V, I i = 8 ma, P i = 5.2 W, C i = 5 nf, L i = 1 H U i = 17.5 V, I i = 8 ma Material Stainless steel AISI 16/1.445 Rating Compact mounted on sensor: IP67/NEMA 4X Remote mounted: IP65 18... 1 Hz random, 1.14 g RMS, in all directions, to IEC 68-2-6, Curve E Siemens FI 1 216 /17

Supply voltage 24 V AC Range Power consumption Power supply 24 V DC Range Power consumption Power supply EMC performance 2... V AC 6 VA I N = 25 ma, I ST = 2 A ( ms) The power supply shall be from a safety isolating transformer. Maximal cable core is 1.5 mm 2 18... V DC 6 W I N = 25 ma, I ST = 2 A ( ms) The power supply shall be from a safety isolating transformer. Maximal cable core is 1.5 mm 2. Emission EN 5511/CISPR-11 (Class A) Immunity NAMUR Ex approval EN/IEC 6126-1 (Industry) Within the value limits according to "Allgemeine Anforderung" with error criteria A in accordance with NE 21 ATEX, EAC Ex: Ex d e ib [ia Ga] IIC T4 Gb Selection and Ordering data MASS 6 transmitter Transmitter Ex d for remote mounting inclusive of wall mounting kit Click on the for the online configuration in the PIA Life Cycle Portal. Enclosure Ex d SS with 5 m (16.5 ft) cable Ex d SS with 1 m (2.8 ft) cable Ex d SS with 25 m (82. ft) cable Output configuration 1 current, 1 frequency, 1 relay A 7ME411 - Supply voltage 24V AC/DC 2 27777-77A7 Ex approvals Ex 1 Display/Keypad With display 1 Serial communication No communication PROFIBUS PA Profile Cable gland M2 1 G H J A B F J Operating instructions for MASS 6 Ex d A5E24488 This device is shipped with a Quick Start guide and a CD containing further SITRANS F iterature. All literature is available to download for free, in a range of languages, at www.siemens.com/processinstrumentation/documentation Note: Only communication modules with Ex approvals are allowed. /18 Siemens FI 1 216

Selection and Ordering data Accessories Add-on module for remote and compact MASS 6 Ex d (Ex-i) FDK:85U226 PROFIBUS PA Profile (Ex-i) (Ex-i) FDK:85U26 A5E25425 Operating instructions for SITRANS F add-on modules PROFIBUS PA/DP German FOUNDATION Fieldbus German A5E878 A5E72617 A5E12642 A5E218728 A5E2488856 This device is shipped with a Quick Start guide and a CD containing further literature. All literature is available to download for free, in a range of languages, at www.siemens.com/processinstrumentation/documentation Dimensional drawings MASS 6 Ex d compact version DImensions in mm (inch) Sensor size [Di (inch)] Ø1 (5.12) L L H 5 H 6 255.1 (1.4) H 5 + H 6 (1/8) 75 (2.5) 82 (.2) 247 (.72) 2 (12.5) 6 (¼) 62 (2.44) 72 (2.8) 257 (1.12) 2 (12.5) 15 (½) 75 (2.5) 87 (.4) 267 (1.51) 54 (1.4) 25 (1) 75 (2.5) 17 (6.81) 271 (1.67) 444 (17.48) 4 (1½) 75 (2.5) 227 (8.4) 271 (1.67) 48 (1.61) H5 H6 MASS 6 Ex d remote version Weight: kg (6.6 lbs) 255 (1.4) 1 (5.12) Dimensions in mm 6 4 28 M5 Dimensions in inch 2.6 1.57.5 1.1 M5 176 (6.) 6 (1.2) 15 1 1 Ø1 5.1.4. Ø.51 1 4xØ 2xØ. 4xØ.5 2xØ.5 8 (.1) Dimensions in mm (inch) Siemens FI 1 216 /1

Schematics Electrical connection compact or remote 1+ 2-1 2 44 45 46 56 57 58 77 78 1 2 5 6 81 82 1 2 8 84 4 8 85 86 5 6 87 88 7 8 /2 Siemens FI 1 216