UCS Engineering Details for the SAN Administrator

Similar documents
UCS Supported Storage Architectures and Best Practices with Storage

UCS Technical Deep Dive: Getting to the Heart of the Matter

UCS Networking 201 Deep Dive

UCS Direct Attached Storage and FC Zoning Configuration Example

UCS SAN Deployment Models and Best Practices

UCS Fabric Fundamentals

Direct Attached Storage

FCoE Cookbook for HP Virtual Connect

Design and Implementations of FCoE for the DataCenter. Mike Frase, Cisco Systems

UCS Networking Deep Dive

Fibre Channel Zoning

UCS-ABC. Cisco Unified Computing System Accelerated Boot Camp. Length: 5 Days. Format: Lecture/Lab. Course Version: 5.0. Product Version: 2.

UCS Fabric Fundamentals

UCS Management Deep Dive

FCoE Configuration Between VIC Adapter on UCS Rack Server and Nexus 5500 Switch

UCS Networking Deep Dive. Neehal Dass - Customer Support Engineer

Designing and Deploying a Cisco Unified Computing System SAN Using Cisco MDS 9000 Family Switches

Using Advanced Features on Cisco UCS Dan Hanson, Technical Marketing Manager, Data Center Group

Cisco UCS Local Zoning

Nexus 5000 NPIV FCoE with FCoE NPV Attached UCS Configuration Example

Cisco CCIE Data Center Written (Beta) Download Full Version :

Traffic Monitoring. Traffic Monitoring

N-Port Virtualization in the Data Center

Troubleshooting the Cisco UCS Compute Deployment BRKCOM Cisco and/or its affiliates. All rights reserved.

CCIE Data Center Written Exam ( ) version 1.0

Deployment Guide: Network Convergence with Emulex OneConnect FCoE CNA and Windows Server Platform

DCNX5K: Configuring Cisco Nexus 5000 Switches

LAN Ports and Port Channels

Cisco Exam Questions & Answers

Configuring Fibre Channel Interfaces

Configuring Cisco UCS Server Pools and Policies

Cisco UCS Manager Storage Management Guide, Release 3.1

Troubleshooting N-Port Virtualization

Host and storage system rules

CCIE Data Center Storage Networking. Fibre Channel Switching

Question: 1 You have a Cisco UCS cluster and you must recover a lost admin password. In which order must you power cycle the fabric interconnects?

UCS Networking Deep Dive

UCS deployment guide for Nimble Storage

UCS Management Architecture Deep Dive

Configuring FCoE NPV. Information About FCoE NPV. This chapter contains the following sections:

Configuring Cisco UCS Server Pools and Policies


Windows 2012 NPIV on UCS Configuration Example

Configuring Service Profiles

vsphere 6.0 with HP ProLiant Gen9 Servers, OneView, 3PAR, Cisco Nexus 5600 and Brocade 6510 Deployment Guide

Inter-VSAN Routing Configuration

Cisco MDS 9000 Family Blade Switch Solutions Guide

Unified Storage Access Design

Cisco Actualtests Questions & Answers

Overview of Cisco Unified Computing System

The Virtual Machine Aware SAN

Reference Architecture. DataStream. UCS Direct Connect. For DataStream OS 2.6 or later Document # NA Version 1.08 April

Nimble Storage SmartStack Getting Started Guide Cisco UCS and VMware ESXi5

Deploying FCoE (FIP Snooping) on Dell PowerConnect 10G Switches: M8024-k, 8024 and 8024F. Dell Networking Solutions Engineering March 2012

UCS Networking Deep Dive

Next Generation Computing Architectures for Cloud Scale Applications

Configuring PortChannels

Large SAN Design Best Practices Using Cisco MDS 9700 and MDS 9500 Multilayer Directors

Vendor: EMC. Exam Code: E Exam Name: Cloud Infrastructure and Services Exam. Version: Demo

HP 6125XLG Blade Switch

CCIE Data Center Lab Exam Version 1.0

ITBraindumps. Latest IT Braindumps study guide

ATTACHMENT A SCOPE OF WORK IMPLEMENTATION SERVICES. Cisco Server and NetApp Storage Implementation

Active System Manager Release 8.2 Compatibility Matrix

Midmarket Data Center Architecture: Cisco Unified Computing System with the Cisco Nexus 1000V Switch

Question No : 3 Which is the maximum number of active zone sets on Cisco MDS 9500 Series Fibre Channel Switches?

Service Profiles and Templates

UCS Uplink Ethernet Connection Configuration Example

UCS Management Deep Dive

Cisco Cisco Data Center Associate Level Accelerated - v1.0 (DCAA)

Cisco Nexus 4000 Series Switches for IBM BladeCenter

Cisco UCS Virtual Interface Card 1225

Vblock Architecture. Andrew Smallridge DC Technology Solutions Architect

UCS Fundamentals Aaron Kerr, Consulting Systems Engineer

You can monitor or use SPAN on port channels only for ingress traffic.

VersaStack for Data Center Design & Implementation (VDCDI) 1.0

Cisco MDS NX-OS Release 6.2Configuration Limits 2

Evolution with End-to-End Data Center Virtualization

SAN Configuration Guide

Fibre Channel Networking for the IP Network Engineer and SAN Core Edge Design Best Practices Chad Hintz Technical Solutions Architect BRKVIR-1121

Using native UCSM and CLI tools for Troubleshooting and Configuration

Cisco Designing Cisco Data Center Unified Fabric (DCUFD) v5.0. Download Full Version :

ECE Enterprise Storage Architecture. Fall 2016

Fibre Channel Gateway Overview

Configuring Server Boot

Service Profiles. Service Profiles in UCS Manager

Jake Howering. Director, Product Management

Dell Networking MXL and PowerEdge I/O Aggregator with Cisco Nexus 5000 series fabric mode Config Sheets

UCS Fundamentals. Conor Murphy Partner Systems Engineer. #clmel BRKCOM-1001

Virtual Networks: For Storage and Data

"Charting the Course... Designing Cisco Data Center Infrastructure (DCID) Course Summary

Implementing Cisco Data Center Unified Computing (DCUCI)

CISCO EXAM QUESTIONS & ANSWERS

"Charting the Course... Troubleshooting Cisco Data Center Infrastructure v6.0 (DCIT) Course Summary

CISCO EXAM QUESTIONS & ANSWERS

Course Description. Boot Camp Date and Hours: The class starts on Saturday 2 nd of April, 2016 Saturdays Only 8:00 AM 4:00 PM Central Standard Time

Designing Cisco Data Center Unified Computing

Expert Reference Series of White Papers. Cisco UCS B Series Uplink Strategies

STORAGE CONSOLIDATION WITH IP STORAGE. David Dale, NetApp

Configuring Service Profiles

Transcription:

UCS Engineering Details for the SAN Administrator Craig Ashapa 2

First things first: debunking a myth Today (June 2012 UCS 2.02m) there is no FCoE northbound of UCS unless you really really really want to That s right, there is no FCoE on external Ethernet uplinks by default In other words, FCoE is used only at the access layer (Server to Fabric Interconnect) in a totally transparent manner You don t need to know anything about FCoE to understand how storage works with UCS Everything works as usual. Servers have HBAs that FLOGI into the SAN fabric, you use zoning and LUN masking just like you do with rackmounts today UCS release 1.4 introduced support for Direct Connect FCoE targets Today, this is the only case where you ll see FCoE traffic You ll have to go through explicit configuration steps to make this happen

Topics Introduction of Converged Network Adapters (CNAs) CNAs and Port WWNs Considerations UCS Storage modes of operation and recommendations End Host Mode - NPV (N_Port Virtualization) FC Switching Mode Upstream Connectivity F_Port Trunking / F_Port Channeling Direct Connectivity of Storage Port Types What works and what doesn t IP-Based Storage Appliance Ports iscsi

Introduction of Converged Network Adapters CNAs and Port WWNs Considerations

Unified Fabric with FCoE CNA: Converged Network Adapter Nexus Edge participates in both distinct FC and IP Core topologies CNA presents multiple PCI addresses to the Operating System (OS) OS loads two unique sets of drivers and manages two unique application topologies Server participates in both topologies since it has two stacks and thus two views of the same unified wire Host FC Multi-Pathing driver provides failover between two fabrics (SAN A and SAN B ) UCS hardware based Fabric Failover (preferred) or OS NIC Teaming provides Ethernet traffic failover FCF Unified Wire shared by both FC and IP topologies Ethernet Driver bound to Ethernet NIC PCI address 10GbE Ethernet Drivers Fibre Channel 10GbE Link PCIe Operating System Ethernet Fibre Channel Drivers FCF Nexus Unified Edge supports both FC and IP topologies FC Driver bound to FC HBA PCI address

CNA: Converged Network Adapter Operating System View Emulex / Qlogic / Cisco Standard drivers Same management Operating System sees: N port or Dual port (depending on hardware) 10 Gigabit Ethernet adapter N port or Dual Port (depending on hardware) Fibre Channel HBAs 7

vhbas: WWN assignment WWN assignment: just like Ethernet MAC addresses Either inherited from burnt-in WWN (not with M81KR!) Or manually set Or borrowed from a pool (recommended) Up to two HBAs (called vhbas) per server with non-m81kr CNAs Backplane path failover does not exist for HBAs! A vhba either goes through switch A or B at any given time OS-level multipathing provides path resiliency Same dynamic pinning concept as with 10GE NICs Manual override allowed by using SAN pin-groups

A word on World-Wide Name formats Avoid interop issues by choosing IEEE Extended Type 2 WW Names inside pools: Section 1 Section 2 Section 3 Section 4 2 0:00 00:25:B5 XX:XX:XX Section 1 identifies the WWN as an extended format WWN Section 2 is a vendor specific code and can be used to identify specific ports on a node or to extend the serial number (section 4) of the WWN Section 3 identifies the vendor (00:25:B5 = Cisco) Section 4 is the serial number for the device

Quick tip how do I determine my port WWNs? Determine the server s pwwn Assigned through the service profile Verify on the host it will match: Check local FLOGI for that pwwn on UCS and MDS: On Windows, use free fcinfo.exe utility

Fabric Interconnects Modes of Operation

What is NPV? N-Port Virtualizer (NPV) utilizes NPIV functionality to allow a switch to act like a server performing multiple logins through a single physical link Physical servers connected to the NPV switch login to the upstream NPIV core switch Physical uplink from NPV switch to FC NPIV core switch does actual FLOGI Subsequent logins are converted (proxy) to FDISC to login to upstream FC switch No local switching is done on an FC switch in NPV mode FC edge switch in NPV mode Does not take up a domain ID UCS Fabric Interconnect FC NPIV Core Switch F-Port Eth1/1 Server1 N_Port_ID 1 NP-Port F-Port Eth1/2 Server2 N_Port_ID 2 F_Port Eth1/3 Server3 N_Port_ID 3 N-Port

N-Port Virtualization (NPV) mode UCS FI works in NPV mode by default Server-facing ports are regular F ports Uplinks toward SAN core fabric are NP ports UCS distributes (relays) FCIDs to attached devices No domain ID to maintain locally Zoning, FSPF, DPVM, etc are not configured on the UCS Fabrics Domain Mgr, FSPF, Zone Server, Fabric Login Server, Name Server They do not run on UCS Fabrics No local switching All FC traffic routed via the core SAN switches

UCS Storage Defaults and Recommendations for FC Default (recommended) - N_Port Virtualization (NPV) Mode End Host Mode for FC, UCS functions as Node Port (initiator) Small to Large Scale Deployments of homogeneous or heterogeneous operating systems Extensive interoperability with SAN and array ecosystem Option - FC Switching Mode UCS FI has limited FC switching features, No Zoning Configuration Must still have upstream MDS or Nexus FC switch via FC Uplink Direct Connect from Fabric Interconnect to Storage Array FC target Designed for POD or Small scale Limited interoperability with Storage ecosystem

UCS Storage Defaults and Recommendations for FCoE Default FCoE Traffic is internal to UCS system (blade to Fabric Interconnect) FCoE packets are terminated at the fabric interconnect, no northbound FCoE packets transmitted from UCS Options FC Switching Mode UCS FI has limited FC switching features, no zoning configuration Must still have upstream MDS or Nexus FC switch via FC Uplink Direct Connect from Fabric Interconnect to Storage Array(s) FCoE target Use of FCoE Storage Targets with UCS Limited interoperability with Storage ecosystem

UCS Storage Defaults and Recommendations for NAS Default (recommended) - End Host Mode Superior traffic engineering - Native L2 multipathing; no spanning-tree Easier integration into network 1.4 Introduced Appliance Ports which allow direct connect NAS filers Options - Ethernet Switching Mode As of 1.4 no storage based reasons to use this mode Previous releases required switching mode for direct connect NAS

UCS Connectivity Summary LAN CLOUD SAN Switch Upstream Switch in NPIV Mode FC STORAGE NAS STORAGE LAN Switch UCS Ethernet in EHM UCS FC in NPV Mode UCS Fabric Interconnect Access Layer LAN & SAN Unified Fabric (FCoE)

Upstream Connectivity SAN Uplinks, Port Channels and Trunks

FC Uplink VSAN Membership Default SAN integration is very straightforward: Connect UCS to external SAN switch (MDS / Brocade) Make FC uplink member of one and only one VSAN No F_Port or NP_Port trunking by default

FC Port Trunking (Multiple VSANs per Link) Provide isolation to SAN traffic over the same physical FC link Help consolidate FC infrastructure vhbas can be on different VSANs Uplink FC ports will be in NPV mode (N- Port) by default All VSANs will be trunked on every uplink FC port Selecting a subset of VSANs for individual uplink ports not supported Scalability: Max of 32 VSANs per UCS system VSAN trunking supported in FC switch mode as well VSAN Trunking is not available for direct connect FC (or FCoE) Storage Port types SAN A SAN B vfcs VSAN 100 VSAN 200 VSAN 300 VSAN 400

FC Port Channels Aggregate and maximize available bandwidth while maintaining isolation Increases resiliency and guard against port failures Up to 16 FC ports can be aggregated together for a single port channel Different combination of FC ports from different expansion modules on the FI can be placed on the same port channel vfcs In case of port speed mismatch port channel forces port speed to highest commonly supported speed VSANs can be trunked over the port channel Port Channel VSAN 100 VSAN 200 VSAN 300 VSAN trunking and port channel supported for both NPV and switch mode FI operation FC Port channeling is not available for direct connect FC Storage Port types SAN A SAN B VSAN 400

How FC Trunking Is Enabled (Global) Global Setting for both FIs Default is Not enabled

Creation and Management of FC Port Channels

Fabric Interconnects FC and Direct Storage Connectivity Options

FC SAN Boot Create Service Profile Configure Storage (simple or expert) Create vhba s (1, 2, or more (M81KR)) Assign Initiator WWPN (manual or pool) Assign VSAN to vhba s Assign vhba Placement Select or Create Boot Policy Assign Target WWPN and LUNID Associate Server Zone Mask Boot to vmedia Install Drivers and OS

Enable Direct Connection of FC/FCOE Storage Customer benefits Support to directly connect FC/ FCoE storage to 6100 End to end FCoE topologies possible Lower cost point for small deployments (no access layer FC switches) FCoE Storage FC Storage Feature details Support for NetApp and EMC direct attached storage Ability to turn On/Off Fibre Channel switching mode Zoning configuration not exposed with UCS Manager Zoning must be inherited from upstream switch Ethernet and FC switching modes are independent UCS 6100 UCS 6100 UCS B-Series

UCS Direct Connect Storage Three UCS port types related to direct storage capability Storage FC Port direct connect this port to FC port on array Storage FCoE Port direct connect this port to FCoE port on array Appliance Port - direct connect this port to 10G Ethernet port on array

UCS Manager View of New Ports

Hybrid Topology with Direct-Attach and SAN SAN Fabric Storage Arrays Fibre Channel Direct Attach Fabric A Core Fabric B Ethernet Unified I/O FC Storage FCoE Storage FCoE SAN Edge A SAN Edge B UCS 6100 UCS 6100 Security via Zoneset Merge AND Security via LUN Masking LUN Masking Always Used to Some Extent UCS B-Series

How to Place FI into FC Switching Mode This operation results in both FIs going into reboot cycles which takes 15 min or so, system wide downtime, by design When FC switch mode is turned on, all the FC ports come up in TE mode

Configuring an FC Storage Port To connect an FC storage device directly into one of the 6100 s FC port, the user must configure the port as an FC storage port The VSAN is configured under the Storage Cloud object Internally, the port is configured as follows: As a F_Port As an access port The speed is kept as auto The user is also allowed to select a named VSAN for that port.

Configuring an FC Storage Port (GUI)

Configuring a VSAN on an FC Port (GUI)

Configuring an FCoE Storage Port (GUI)

Configuring an FCoE Storage Port (Cont.) Since the Ethernet port is configured as trunk, a native VLAN must be configured on that port. The FCoE VLAN ID can not be the same as the native VLAN ID User is not requested to provide a native VLAN value. An arbitrary VLAN (4048) was chosen and is always used as the native VLAN for FCoE storage ports unless changed

FCoE Port Must Be Assigned to a VSAN

IP-based Storage Appliance Ports and iscsi

UCS Manager Appliance Ports What is an Ethernet Appliance A specialized device for use on a Ethernet network, for example Network Attached Storage, iscsi, security appliances, Nexus 1010 What qualifies to be an appliance An Appliance is a specialized external host, does not run STP (today only NetApp and EMC IP storage devices qualified) Purpose of Appliance Port Connect Ethernet appliances only! Do Not to use this port type for switch connectivity to avoid traffic loops

Appliance Ports How to Configure

Appliance Port Exposed Settings QoS per port settings, normal UCS QoS constructs Manual (static) pinning using pin groups for border port selection Select which VLANs can traverse this port Optionally specify the destination MAC address of the filer. Some Filers do not broadcast their MAC address

VLANs and Appliance Ports Similar to VSAN concept, there are two scopes Traditional, LAN Cloud Appliance Cloud with scope restricted to appliance ports and associated VLANs Use the same VLAN ID in both scopes

iscsi Feature Overview

iscsi Boot Flow Create iscsi vnics Create iscsi boot policy Provide UCSM with iscsi boot information Target ip, iqn Initiator ip/mask/gw, iqn vmedia map the OS and drivers Adapter successfully initializes Install OS and Drivers (if required) 43

Storage Vendor Support UCS 1.4 Direct Connect only support EMC and NetApp for all topologies (FC, FCoE, NAS) We may add more vendors as a function of time given business case justifications iscsi Boot will only support EMC and NetApp Arrays We may add more vendors as a function of time given business case justifications Please Consult the these resources http://www.cisco.com/en/us/products/ps10477/prod_technical_reference_list.html http://www.cisco.com/en/us/docs/unified_computing/ucs/interoperability/matrix/r_hcl_ B_rel2.02.pdf

Complete Your Online Session Evaluation Give us your feedback and you could win fabulous prizes. Winners announced daily. Receive 20 Passport points for each session evaluation you complete. Complete your session evaluation online now (open a browser through our wireless network to access our portal) or visit one of the Internet stations throughout the Convention Center. Don t forget to activate your Cisco Live Virtual account for access to all session material, communities, and on-demand and live activities throughout the year. Activate your account at the Cisco booth in the World of Solutions or visit www.ciscolive.com. 45

Presentation_ID