Technical Specifications. Dual Source kwh Energy Meter

Similar documents
Technical Specificaions. kwh Energy Meter

Technical Specifications. Dual Source Energy Meter (EB / DG)

Technical Specifications. Multi Function Meter

QUICK SETUP GUIDE. BCM2 Series Branch Circuit Monitors. Safety Information. Equipment Maintenance and Service. Raritan DANGER!

BCM2 Series Branch Circuit Monitors Quick Setup Guide

ACCESS 9340/9360 Meter Input/Output Module

INSTALLATION DKM-409 NETWORK ANALYSER WITH HARMONIC MEASUREMENT AND SCOPEMETER. Before installation:

PowerLogic High Density Metering System 1-Meter Enclosure

StruxureWare Power Monitoring Expert 8.0 Data Center Edition

QUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB PM Series Power Meter. Safety Information. Equipment Maintenance and Service.

QUICK SETUP GUIDE. BCM2 Series Branch Circuit Monitors. Safety Information. Equipment Maintenance and Service. Product Overview. Raritan DANGER!

PM Series Power Meter

AcquiSuite Ally 12 & 48 Advanced Multi-Circuit Meter

Generator Performance Guide 7EN /2015

ENERCEPT H8035/H8036 DANGER NOTICE CAUTION. Networked Power Transducer (Modbus RTU) INSTALLATION GUIDE QUICK INSTALL TABLE OF CONTENTS

IPD163C. Single-Phase Multifunction Meter User Manual Version: V1. August 20, 2017

QUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB-1960, PMMC-1000 PM Series Power Meter

H704-42(H)(E), H704-42/1(H)(E)

S7999D SOLA Operator Interface Display

METERSUK. SmartLink D Y N A M i T E. 3 MOD CT Series. User Manual KEY FEATURES INDEX 3. TECHNICAL DESCRIPTION.

PowerLogic ION7550 RTU option

GE Industrial Solutions. DET-756 Installation Instructions ASPMETER Panelboard Monitoring System

Iso DIN. User Manual. 1 channel Earth Fault Monitoring

CEM M-RS485 INSTRUCTION MANUAL (M014B A)

HIGH-VOLTAGE DC METER

SPM91 DIN Rail Single Phase Energy Meter Installation & Operation Manual V1.0

Instruction Bulletin. Sepam Series 20 & 40 Relays Quick Start Guide

MultiCube Single Phase Multi-Function Electricity Meter. Installation and Operation

USER MANUAL 2012 V1.1

High Voltage DC Meter

12-36 VDC/12-24 VAC Power Option 4-Digit Display, 0.56 (14.2 mm) or 1.20 (30.5 mm)

SEM3 - Embedded Micro Metering Module

BCPM Series Panelboard Monitoring Systems

Trident and Trident X2 Digital Process and Temperature Panel Meter

Conext CL-60 Inverter Firmware Upgrade Process

DTS 310. DIN Rail Mounted, Indoor Rated Revenue Grade Electrical Sub-meter. Page 1. Measurlogic MQ A

IMPORTANT SAFETY INSTRUCTIONS

DEIF A/S. MIC Multi-instrument G. Data sheet. Features. Accuracy. Measurements. Installation. Intelligent. Display. Communication DEIF A/S

DKM-407 DIN RAIL TYPE NETWORK ANALYZER

MIC-2 MKII & MIC-2 MKII DIN, Multi-instrument DATA SHEET

LE ELECTRONICS Pvt. Ltd.

CEM-C30 INSTRUCTION MANUAL (M017B A)

RGM180 Display Series

Smart Energy Meter. Benefits and Main Features. User Manual Revision English OB (100)A

StruxureWare Power Monitoring Expert for Healthcare 7.2

CEM-C6 INSTRUCTION MANUAL (M187B B)

RST ROOM TEMPERATURE TRANSMITTER. Mounting and operating instructions

PD765 TRIDENT. Trident Series Process & Temperature Meters.

CEM M-ETH INSTRUCTION MANUAL (M060B A)

Multi-Measuring-Interface MMI 6000

Digital Multifunction Meters. Digital Multifunction Meters

RXTH DUAL ROOM SENSOR / SWITCH

2 Table of Contents 1. TABLE OF CONTENTS. 1. Table of Contents Introduction Wiring Diagram Terminals Review...

PD765 TRIDENT. Trident Series Process & Temperature Meters.

MIC-2 Multi-instrument DATA SHEET

MID PRELIMINARY DATA SHEET. RI-D Series. Single Phase Multifunction Energy Meter (MID Certified) MID

Instruction Bulletin Trim and Rail Extension Kit (6-, 12-, and 18-inch) Installation onto an NF Panelboard Class 1670

GE Power Management. MMII Intelligent MCC Controller

Models beginning with 2M, 2L or 2X. Product Description. Technical Specifications. Installation Instructions. Series 2000 Multiple Meter Units (MMUs)

Multilin EPM 4600 Metering Solution

SAVE THESE INSTRUCTIONS

Integrated Metering Systems, Inc.

SDM630M CT USER MANUAL 2016 V4.7. DIN Rail Energy Meter for Single and Three Phase Electrical Systems

Square D Clipsal Pascal Automation Controller

RXTP ROOM TEMPERATURE

DKM-405 NETWORK ANALYSER WITH TOTAL HARMONIC DISTORTION DISPLAY

SGE-3G/GPRS INSTRUCTION MANUAL (M179B A)

Process & Temperature Digital Panel Meter

MIC-2 MKII, Multi-instrument DATA SHEET

HAT600 Series HAT600/HAT600I/HAT600B/HAT600BI ATS CONTROLLER USER MANUAL

Quick Start Guide TS A

ATS22D62Q soft starter-ats22-control 220V-power 230V(15kW)/ V(30kW)

ATS22C41Q soft starter-ats22-control 220V-power 230V(110kW)/ V(220kW)

PADPULS2 M-BUS Pulse Input Modules

PowerLogic ION7300 Series

Sidewinder Pumps Inc. AC C1D2 Timer/Controller

PFC-10 Power Factor Controller

HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH

RDM172 Remote Display Module QUICK GUIDE

ATS22D75S6 soft starter-ats22-control 220V-power 230V(18.5kW)/ V(37kW)/500V(45kW)

Multi Unit Enclosed Meter

DXTH DUCT SENSOR / SWITCH FOR TEMPERATURE AND HUMIDITY. Mounting and operating instructions

7KM2112-0BA00-3AA0 SENTRON PAC3200. English. Operating Instructions DANGER CAUTION DANGER. Order-No.: A5E Last update: 18 January 2008

B+G E-Tech User Manual for SDM630 SDM630. Din Rail Smart Energy Meter for Single and Three Phase Electrical Systems USER MANUAL 2013 V1.

EM132 EM132. Main Features. Multi-functional 3-Phase Transducer. Energy Meter

0.01kV (0 to ±0.99 kv)

EC700. Pulses concentrator. User instructions

Technical data sheet. PowerLogic power-monitoring units EM3500 series DIN Rail meter

Single Kernel Grain Moisture Tester PQ-520. (type PQ ) Operating Instructions

EnerSure Installation Guide

GV3000/SE Operator Interface Module (OIM) User Guide Version 2.0 M/N 2RK3000

CVM-B100 CVM-B150 INSTRUCTION MANUAL (M010B B)

POWER SERIES Plus Watt-VAR / Watt-Power Factor Digital Switchboard Meter User s Manual IM2492WVPF-1

Energy Logger. User's Guide. Model EM Washington Street Melrose, MA Phone Toll Free

INSTALLATION INSTRUCTIONS

Clipsal Bus Couplers. Two Channel (SLC5102BCLEDL) and Four Channel (SLC5104BCL) for Use with C-Bus Wired Systems

Power Meter PowerMonitor 500

MW/MVAR Transducer Specifications

Energy Management Modular DC Energy analyzer Type VMU-E and VMU-X

IIM Warwick Court. Williamsburg VA REV 5

Transcription:

Technical Specifications of Dual Source kwh Energy Meter (SPKG300) Class 0.5S Sai PowerrZerve 29/3B, Rajalakshmi Nagar, 1 st Main Road, Velachery Bye Pass, Chennai 600 042. Website :www.spowerz.com Email : info@spowerz.com Phone : 044-43192660 1 SPZ/SPMG300-TS/V1.0

General Specifications 1) GENERAL: Meter measures Active Power and Active energy on 3 phase 4 wire system, All four quadrant measurement for KWh are measured and stored in energy accumulators, Parameters can be viewed through 7 segment LED (3 row), Soft Keys are provided to stop, scroll, edit and to view the parame RTC with battery backup is used for time keeping and has a calendar of 100 years, Power Line Communication can be done using RS485 communication with MODBUS RTU, 2) METER FEATURES: 2.1) Display Details: 7 segment (3*4 digits) LED type The parameters are calculated by the meter are displayed, Selectable Parameters Can select any out of 8 parameters. Scroll rate The scroll rate of the display parameter scroll in steps of 4secs. Keys are provided to stop, scroll, edit and to view the particular parameter. 2.1.1) Display Parameters: Time, Date, Meter ID with Phase Sequence, Frequency (Hz.), Instant Active Power KW R,Y,B,(EB/DG) Instant KW RYB. (EB/DG) Cumulative RYB Active Energy (KWh), (EB) Cumulative RYB Active Energy (KWh), (DG) 2 SPZ/SPMG300-TS/V1.0

2.2) Key Features: The Parameter setup can be done through 4 nos. of soft keys on front fascia, Keys on the front panel is used to scroll, increment, decrement through display parameter and set the Meter ID, CT Primary values, Time & Date, MD Reset (EB / DG), Energy Reset(EB / DG), Change Password. Press scroll key once the parameter set is completed, this allows to view the parameters one after the other automatically (change over time period is 4 secs). If this is not done auto scroll will not happen. Fig.:- Key Feature Description 3 SPZ/SPMG300-TS/V1.0

2.3) Rear Terminal Details: 2.4) Communication: 2.4.1) Communication Interface: Note: Through RS485 Communication with MODBUS RTU, Baud Rate : 9600 Power Line Communication using Power Line Node and Concentrator. (i) Field Programmability of the meter is optional based on the customer requirement, (ii) Each meter is given a unique number at the factory. 4 SPZ/SPMG300-TS/V1.0

2.5) Safety Precautions: HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Apply appropriate personal protective equipment (PPE) and follow safe electrical work practices. Only qualified electrical workers should install this equipment. Such work should be performed only after reading this entire set of instructions. If the equipment is not used in a manner specified by the manufacturer, the protection provided by the equipment may be impaired. NEVER work alone. Before performing visual inspections, tests, or maintenance on this equipment, disconnect all sources of electric power. Assume that all circuits are live until they have been completely de-energized, tested, and tagged. Pay particular attention to the design of the power system. Consider all sources of power, including the possibility of back feeding. Turn off all power supplying the dual energy meter and the equipment in which it is installed before working on it. Always use a properly rated voltage sensing device to confirm that all power is off. Before closing all covers and doors, inspect the work area for tools and objects that may have been left inside the equipment. When removing or installing panels do not allow them to extend into the energized bus. The successful operation of this equipment depends upon proper handling, installation, and operation. Neglecting fundamental installation requirements may lead to personal injury as well as damage to electrical equipment or other property. NEVER bypass external fusing. NEVER short the secondary of a PT. NEVER open circuit a CT High voltage testing may damage electronic components contained in the dual energy meter. Ensure that no wiring strands are straying outside after connecting the wires. Dual Source Energy Meter should be installed in a suitable electrical enclosure. Failure to follow these instructions will result in death or serious injury 5 SPZ/SPMG300-TS/V1.0

Technical Specifications Accuracy : Class 0.5S System type : 3 Phase 4 Wire Resolution : 0.01 (for Combined Kwh) Display : Multi Parameter LED (3 ROW) Auxiliary Supply : 85 265 VAC Current CT : Primary side Programmable (5A 6000A) : Secondary side 1 or 5A Starting Current : 10mA Power Factor : 4 quadrant operation Frequency : 50Hz, ±5% Communication : RS485 Communication with MODBUS RTU in external integration with Power Line Communication Temperature : Operating Temp. (-10 to 55) C Storage Temp. (-20 to 70) C Humidity 5 to 95% RH at 50 C (Non-Condensing) Dimension : (96 x 96 x 48) mm (Inclusive of connector) Panel Cutout : 92 x 92 mm (-0.5mm) Mounting : Panel Mountable Connector Type : Screw type terminals (U Lug 2.5mm) Weight : 350gms. (app.) 6 SPZ/SPMG300-TS/V1.0