AE/CE Series Industrial Control Transformers

Similar documents
AE/CE Series Industrial Control Transformers

SECTION5AE/CE SERIES INDUSTRIAL CONTROL TRANSFORMERS

Industrial Control. 50 to 5,000 VA. Applications. Specifications. Standards. Options and Accessories. Features, Functions, Benefits.

Industrial Control. 50 to 5,000 VA. Applications. Specifications. Standards. Options and Accessories. Features, Functions, Benefits.

VTD SERIES p. 108 DC Input, 15 to 600 V. VTD-BD SERIES p. 110 DC Input, 15 to 600 V

CROWN CLIP Series Sockets

PanelView Plus/VersaView CE Terminals and Display Modules

SECTION 1 PT SERIES CONTROL TRANSFORMERS

Safety switches for hinged doors

ENCAPSULATED TRANSFORMERS FOR HAZARDOUS LOCATIONS

K1C024B body for BCD encoded output switch - 1 pole A - for Ø 22 mm

K1D004ACH cam switch - 4-pole A - for Ø 22 mm

ABE7R16S210 sub-base - soldered electromechanical relays ABE7-16 channels - relay 10 mm

Safety switches with separate actuator

Push-Pull and E-Stop Switches. Datasheet

Features. Applications and Benefits TRC ELECTRONICS, INC

K1F037MCH cam voltmeter switch - 3L and 3L-N A - for Ø 22 mm

Argent Angel S series PCB Soldering Power Transformers

ICS Regent. Relay Output Modules. Low Power and High Power (T3446L and T3446H) PD-6017

Quantum III. Compact DC Drive Package. Slitter DC Drive Package. Quantum III

K1D011B body for BCD encoded output switch - 1 pole A - for Ø 22 mm

Gelo LED Driver 100W, Single output, Constant Voltage RGLD100-24

PV Rapid Shutdown device

OVERLOAD RELAYS POWER & ACTUATION PROVEN. series

HID Ballast Kits. Specifications. Electronic. Ballasts. Fluorescent Ballasts. Compact. Ballasts HID

SR60 Busbar System 2/1 2/2. General Data. 2/3 Busbar routing. 2/7 Mounting components. 2/13 Accessories

Gelo LED Driver 100W, Single output RGLD100-24

SagFighter Active Voltage Conditioner / Sag Ride Through (SRT)

K1B004TLH cam switch - 1 pole A - screw mounting

E-Series General Specifications

PRM MODEL TABLE. (1) Measured at 115V a-c source.

Power supply module, bus connection module

Safety switches with manual mechanical delay and separate actuator

K1D012ULH cam changeover switch - 2-pole A - screw mounting

Safety switches with separate actuator

SSV-T and SSC-T High Drop-out Relay. Range amps amps amps amps. Operating Frequency: Temperature Error:

Installation RA5112-C-16A-C20. Basic Rack Power Distribution Unit

RM35UB3. Product data sheet Characteristics. voltage control relay RM35-U - range V AC. Main. Complementary

TRIO-PS/1AC/24DC/20. Extract from the online catalog. Order No.:

GLX40 GLX50 UL EN GLX60 GLX110-B GLX110-C GLX200 GLX140-C GLX140-CF GLX150-C GLX17Q-C GLX17S-C GLX250-CEF GLX250-CF

RM35TF V AC

Installation Instructions H Series

K1K015NZ4 cam stepping switch - 2-pole A - screw mounting

Power Supplies GLX40 GLX50 GLX60 GLX110-B GLX110-C GLX120 GLX140-C GLX140-CF GLX150-C GLX17Q-C GLX17S-C GLX200 GLX250-CEF GLX250-CF

RM17UB3. Product data sheet Characteristics. voltage control relay RM17-U - range V AC. Main. Complementary

MCFCW-20-4HS-1 (4-Pipe) High Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 60,000 BTUH

P/N: AX Distribute your control functions directly onto the valve.

Distinctive Characteristics

MCFCW-08-4LS-1 (4-Pipe) Low Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 24,000 BTUH

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

Safety switches with separate actuator

Model 720 Electromechanical Hour Meter

MCFCW-06-4HS-1 (4-Pipe) High Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 18,000 BTUH

CompactLogix Power Supplies Specifications

Power supply CP-C 24/5.0

6 Buck Boost Transformers

Volastic VC-M 15 Amp Module

Max. Input Power (W) Input Current. Inrush Current

5/2 Product overview. 5/3 Distribution board components. 5/9 Built-in components. 5/17 Mounting components 5. Siemens ET B1 10/2009

HIGH DENSITY TERMINAL BLOCKS

MAXIMA+ Series Rotary Level Indicator

PHOENIX CONTACT Features

S66 Series Electronic Fan Speed Control

2.) Cabinet setup and preset data shall, as standard, be fully user programmable on a per cabinet or system wide basis.

Motor protection relays

TOT Series Manual. North American CE and UK Models. CE Models. UK Models. North American Models

M E M O R A N D U M I.S.

T775S Series 2000 Expansion Module

Airflow Pressure Sensor

Standardized valve series MI-01 Connection pattern according to ISO 5599/1, size 1, 5/2- and 5/3-way NG and 1700 Nl/min (1.636 and 1.

For (2) Single Receptacles: dia. Hole Standard Depth

920 Remote Control (RC) Switches

XPSMP11123P module XPS-MP - 2 independent functions - 24 V DC

MAXIMA + Series ROTARY LEVEL CONTROL

TOT Series Manual. North American and International Models - without optional faceplate. Receptacle Panel of International Models, CE model shown

Single-Phase Encapsulated

[.050 (1.27mm) Density. D-Microminiature]

FT & RT Test Switches

Free Energy Band RCC30U Room Temperature Controller for Four-pipe Fan Coil Unit

NF44E-.. / NFZ44E-.. Contactor Relays AC / DC Operated - with Screw Terminals

AC to AC Output Adapters

ABE7R16S210 sub-base - soldered electromechanical relays ABE7-16 channels - relay 10 mm

APL/UPL, 205/295 Series Magnetic Circuit Protectors

MODEL SST3-MV INSTALLATION INSTRUCTIONS FOR FEDERAL MODEL SST3-MV SELECTABLE SIRENTONE-MULTI VOLT

The HAHN UI 30 Series Quality and efficiency in series

NEUROLOGIC RESEARCH CORPORATION MODEL 2500

EZ-ZONE. EZ-ZONE ST Integrated Control Loop Makes Solving the Thermal Requirements of Your System Easy

RM17UB3. Price* : USD

R-LB R-LX Series Installation, Operation & Maintenance Manual

RM17UAS. Product datasheet Characteristics. voltage control relay RM17-U - range V DC. Main. Complementary. Price* : 70.

Output signal active note. Output signal. temperature DC V, DC V DC V, DC V DC V

ASCO 920 Remote Control (RC) Switches

CRM Control Panel and Weather Detection System CRM3 for DC actuators (part # 40821J) CRM4 for AC actuators (part # 40822K)

Instrument Current Transformers

ALLEN BRADLEY RELAY Bulletin 700-HF

Programmable DC power supplies

Power Sensing Products

File E Project 12SC February 9, 2013 REPORT. Component - Protectors, Low-voltage Solid-state Overcurrent

EZ-ZONE. EZ-ZONE ST Integrated Control Loop Makes Solving the Thermal Requirements of Your System Easy

SMARTONLINE E3 UPS SYSTEMS

Transcription:

AE/E SERIES INDUSTRIAL ONTROL TRANSFORMERS AE/E Series Industrial ontrol Transformers The Acme Electric AE and E Series Industrial ontrol Transformers are designed specifically for machine tool control circuit applications. These transformers have the ability to handle potentially damaging high in-rush currents that occur when electromagnetic components are energized, without sacrificing the required stable output voltage. Designed to meet or exceed the demands of international standards, combined with the full breadth of product offering, the AE and E Series Transformers from Acme Electric are the ideal solution for your industrial control applications. FEATURES & BENEFITS Epoxy encapsulated design protects core & coil assembly from potentially damaging contaminants. Integrally molded terminal blocks with isolation barriers to prevent arc over, terminal blocks allow full access for ring terminals for easy installation and solid termination. Heavy gauge steel mounting feet. ooler. leaner. More ompact. The AE and E Series design improves the dissipation of the heat away from the core and coil assembly providing cooler operation. In addition, the AE and E Series industrial control transformers seal the transformer s windings and internal terminations within an epoxy encapsulant encased in a durable thermoplastic end cap, protecting them from potentially damaging moisture, dirt and other ambient contaminants. Furthermore, Acme s compact design helps minimize the mounting footprint, providing more flexibility in applications where space is at a premium. Available factory or field installed fuse blocks provide integral fusing on the primary or primary and secondary. Dual labeling for easy product identification when equipped with a fuse block. 50-750 VA, 50/60 Hz. UL and cul Listed, E Marked (E Series only). Ten-year limited warranty. 55 Temperature Rise. 105 Insulation lass. E Series for Global Applications Acme s E Series Encapsulated Industrial ontrol Transformers carry the E mark, indicating it complies with the requirements established by the International Electrotechnical ommission (IE) for use of control circuit transformers in the countries of the European Union. Regulations that apply to control transformers include Low Voltage Directive 73/23/EE and Electromagnetic ompatibility (EM) Directive 89/336/EE. 80

AE/E SERIES INDUSTRIAL ONTROL TRANSFORMERS FEATURES Integrally molded terminal blocks with combination slotted/phillips screws. Isolation barriers protect against arc over while able to accommodate a full ring terminal. Integrally mounted fuse blocks available in standard and touch-proof (E Series) style. Dual labels for identification of fused modules E Series offers touch-proof terminals, isolating live contacts for additional safety. Epoxy encapsulated copper windings and internal terminations, providing isolation from external contaminants and physical damage. 81

AE/E INDUSTRIAL ONTROL TRANSFORMERS SELETION HARTS GROUP I 120 x 240 PRIMARY VOLTS 24 SEONDARY VOLTS 1Ø, 50/60 Hz AE SERIES 50 AE01-0050 2.69 (6.8) 3.00 (7.6) 2.81 (7.1) 2.03 (5.1) 2.53 (6.4).20 x.40 (0.5 x 1.0) 2.50 (1.1) 75 AE01-0075 3.22 (8.1) 3.00 (7.6) 2.81 (7.1) 2.53 (6.4) 2.53 (6.4).20 x.40 (0.5 x 1.0) 3.50 (1.6) 100 AE01-0100 3.28 (8.3) 3.41 (8.6) 3.09 (7.8) 2.41 (6.1) 2.81 (7.1).20 x.40 (0.5 x 1.0) 4.05 (1.8) 150 AE01-0150 3.88 (9.8) 3.78 (9.6) 3.41 (8.6) 2.97 (7.5) 3.13 (7.9).20 x.40 (0.5 x 1.0) 6.50 (2.9) 250 AE01-0250 4.13 (10.4) 4.50 (11.4) 3.84 (9.7) 2.94 (7.4) 3.75 (9.5).20 x.40 (0.5 x 1.0) 9.25 (4.2) 350 AE01-0350 5.00 (12.7) 4.50 (11.4) 3.84 (9.7) 3.78 (9.6) 3.75 (9.5).20 x.40 (0.5 x 1.0) 12.75 (5.8) 500 AE01-0500 5.53 (14.0) 5.25 (13.3) 4.66 (11.8) 4.16 (10.5) 4.38 (11.1).31 x.69 (0.8 x 1.7) 19.00 (8.6) 750 AE01-0750 6.81 (17.3) 5.25 (13.3) 4.66 (11.8) 5.75 (14.6) 4.38 (11.1).31 x.69 (0.8 x 1.7) 26.00 (11.8) GROUP II 200//, 208//, 240/480 PRIMARY VOLTS 23/110, 24/115, 25/120 SEONDARY VOLTS 1Ø, 50/60 Hz 50 AE02-0050 3.28 (8.3) 3.00 (7.6) 2.78 (7.0) 2.25 (5.7) 2.53 (6.4).20 x.40 (0.5 x 1.0) 3.0 (1.4) 75 AE02-0075 3.28 (8.3) 3.00 (7.6) 3.09 (7.8) 2.53 (6.4) 2.81 (7.1).20 x.40 (0.5 x 1.0) 4.0 (1.8) 100 AE02-0100 3.28 (8.3) 3.41 (8.6) 3.41 (8.6) 2.53 (6.4) 3.13 (7.9).20 x.40 (0.5 x 1.0) 4.0 (1.8) 150 AE02-0150 4.03 (10.2) 3.75 (9.5) 3.41 (8.6) 3.28 (8.3) 3.13 (7.9).20 x.40 (0.5 x 1.0) 7.0 (3.2) 250 AE02-0250 4.38 (11.1) 4.50 (11.4) 4.03 (10.2) 3.75 (9.5) 3.75 (9.5).20 x.40 (0.5 x 1.0) 9.0 (4.1) 300 AE02-0300 5.13 (13.0) 4.50 (11.4) 4.97 (12.6) 3.88 (9.8) 4.38 (11.1).31 x.69 (0.8 X 1.7) 11.0 (5.0) 350 AE02-0350 5.25 (13.3) 4.50 (11.4) 4.97 (12.6) 4.16 (10.5) 4.38 (11.1).31 x.69 (0.8 X 1.7) 13.0 (5.9) 500 AE02-0500 6.31 (16.0) 5.25 (13.3) 4.97 (12.6) 5.25 (13.3) 4.38 (11.1).31 x.69 (0.8 X 1.7) 19.0 (8.6) 750 AE02-0750 6.81 (17.3) 5.25 (13.3) 4.97 (12.6) 5.75 (14.6) 4.38 (11.1).31 x.69 (0.8 X 1.7) 27.0 (12.2) GROUP III 240 x 480 PRIMARY VOLTS 24 SEONDARY VOLTS 1Ø, 50/60 Hz 50 AE03-0050 2.69 (6.8) 3.00 (7.6) 2.81 (7.1) 2.03 (5.1) 2.53 (6.4).20 x.40 (0.5 x 1.0) 2.5 (1.1) 75 AE03-0075 3.22 (8.1) 3.00 (7.6) 2.81 (7.1) 2.53 (6.4) 2.53 (6.4).20 x.40 (0.5 x 1.0) 3.5 (1.6) 100 AE03-0100 3.28 (8.3) 3.41 (8.6) 3.09 (7.8) 2.41 (6.1) 2.81 (7.1).20 x.40 (0.5 x 1.0) 4.0 (1.8) 150 AE03-0150 3.88 (9.8) 3.84 (9.7) 3.41 (8.6) 2.97 (7.5) 3.13 (7.9).20 x.40 (0.5 x 1.0) 6.5 (2.9) 250 AE03-0250 4.13 (10.4) 4.50 (11.4) 3.84 (9.7) 2.94 (7.4) 3.75 (9.5).20 x.40 (0.5 x 1.0) 9.2 (4.2) 350 AE03-0350 5.00 (12.7) 4.50 (11.4) 3.84 (9.7) 3.78 (9.6) 3.75 (9.5).20 x.40 (0.5 x 1.0) 12.7 (5.8) 500 AE03-0500 5.53 (14.0) 5.25 (13.3) 4.66 (11.8) 4.16 (10.5) 4.34 (11.0).31 x.69 (0.8 X 1.7) 19.0 (8.6) 750 AE03-0750 6.81 (17.3) 5.25 (13.3) 4.66 (11.8) 5.75 (14.6) 4.38 (11.1).31 x.69 (0.8 X 1.7) 26.0 (11.8) 82

AE/E SERIES INDUSTRIAL ONTROL TRANSFORMERS GROUP VI 240 x 480, x, x PRIMARY VOLTS 120/115/110 SEONDARY VOLTS 1Ø, 50/60 Hz 50 AE06-0050 2.69 (6.8) 3.00 (7.6) 2.81 (7.1) 2.03 (5.1) 2.53 (6.4).20 x.40 (0.5 x 1.0) 2.5 (1.1) 75 AE06-0075 3.22 (8.1) 3.00 (7.6) 2.81 (7.1) 2.53 (6.4) 2.53 (6.4).20 x.40 (0.5 x 1.0) 3.5 (1.6) 100 AE06-0100 3.28 (8.3) 3.41 (8.6) 3.09 (7.8) 2.41 (6.1) 2.81 (7.1).20 x.40 (0.5 x 1.0) 4.0 (1.8) 150 AE06-0150 3.88 (9.8) 3.84 (9.7) 3.41 (8.6) 2.97 (7.5) 3.13 (7.5).20 x.40 (0.5 x 1.0) 6.5 (2.9) 250 AE06-0250 4.13 (10.4) 4.50 (11.4) 3.84 (9.7) 2.94 (7.4) 3.75 (9.5).20 x.40 (0.5 x 1.0) 9.2 (4.2) 350 AE06-0350 5.00 (12.7) 4.50 (11.4) 3.84 (9.7) 3.78 (9.6) 3.75 (9.5).20 x.40 (0.5 x 1.0) 12.7 (5.8) 500 AE06-0500 5.53 (14.0) 5.25 (13.3) 4.66 (11.8) 4.16 (10.5) 4.34 (11.0).31 x.69 (0.8 X 1.7) 19.0 (8.6) 750 AE06-0750 6.81 (17.3) 5.25 (13.3) 4.66 (11.8) 5.75 (14.6) 4.31 (10.9).31 x.69 (0.8 X 1.7) 26.0 (11.8) GROUP VII 208// PRIMARY VOLTS 115 SEONDARY VOLTS 1Ø, 50/60 Hz 50 AE07-0050 2.84 (7.2) 3.00 (7.6) 2.81 (7.1) 2.16 (5.4) 2.53 (6.4).20 x.40 (0.5 x 1.0) 2.6 (1.2) 100 AE07-0100 3.41 (6.6) 3.41 (8.6) 3.09 (7.8) 2.69 (6.8) 2.81 (7.1).20 x.40 (0.5 x 1.0) 4.2 (1.9) 150 AE07-0150 3.88 (9.8) 3.75 (9.5) 3.41 (8.6) 3.09 (7.8) 3.09 (7.8).20 x.40 (0.5 x 1.0) 6.7 (3.1) 250 AE07-0250 4.16 (10.5) 4.50 (11.4) 4.03 (10.2) 3.28 (8.3) 3.75 (9.5).20 x.40 (0.5 x 1.0) 9.5 (4.3) 350 AE07-0350 5.19 (13.1) 4.50 (11.4) 4.03 (10.2) 4.38 (11.1) 3.75 (9.5).20 x.40 (0.5 x 1.0) 13.4 (6.1) 500 AE07-0500 5.88 (14.9) 5.25 (13.3) 4.66 (11.8) 4.78 (12.1) 4.38 (11.1).31 x.69 (0.8 X 1.7) 19.0 (8.6) 750 AE07-0750 6.81 (17.3) 5.25 (13.3) 4.66 (11.8) 5.75 (14.6) 4.38 (11.1).31 x.69 (0.8 X 1.7) 27.0 (12.2) GROUP XII //575 PRIMARY VOLTS 95/115 SEONDARY VOLTS 1Ø, 50/60 Hz 50 AE12-0050 2.88 (7.3) 3.00 (7.6) 2.81 (7.1) 2.19 (5.5) 2.53 (6.4).20 x.40 (0.5 x 1.0) 2.6 (1.2) 100 AE12-0100 3.59 (9.1) 3.41 (8.6) 3.09 (7.8) 2.88 (7.3) 2.81 (7.1).20 x.40 (0.5 x 1.0) 4.2 (1.9) 150 AE12-0150 3.94 (10.0) 3.78 (9.6) 3.41 (8.6) 3.28 (8.3) 3.09 (7.8).20 x.40 (0.5 x 1.0) 6.8 (3.1) 250 AE12-0250 4.16 (10.5) 4.50 (11.4) 4.03 (10.2) 3.22 (8.1) 3.75 (9.5).20 x.40 (0.5 x 1.0) 9.5 (4.3) 350 AE12-0350 5.00 (12.7) 4.50 (11.4) 4.03 (10.2) 3.69 (9.3) 4.31 (10.9).20 x.40 (0.5 x 1.0) 13.2 (6.0) 500 AE12-0500 5.84 (14.8) 5.25 (13.3) 4.66 (11.8) 4.66 (11.8) 4.38 (11.1).31 x.69 (0.8 X 1.7) 19.2 (8.7) 750 AE12-0750 6.81 (17.3) 5.25 (13.3) 4.66 (11.8) 5.81 (14.7) 4.38 (11.1).31 x.69 (0.8 X 1.7) 27.0 (12.2) 83

AE/E SERIES INDUSTRIAL ONTROL TRANSFORMERS SELETION HARTS E SERIES GROUP I 120 x 240 PRIMARY VOLTS 24 SEONDARY VOLTS 1Ø, 50/60 Hz 50 E01-0050 2.69 (6.8) 3.00 (7.6) 2.81 (7.1) 2.25 (5.7) 2.56 (6.5).20 x.40 (0.5 x 1.0) 2.5 (1.2) 75 E01-0075 3.22 (8.1) 3.41 (8.6) 2.81 (7.1) 2.25 (5.7) 2.88 (7.3).20 x.40 (0.5 x 1.0) 3.5 (1.6) 100 E01-0100 3.28 (8.3) 3.75 (9.5) 3.09 (7.8) 2.53 (6.4) 3.13 (7.9).20 x.40 (0.5 x 1.0) 4.2 (1.9) 150 E01-0150 3.88 (9.8) 4.50 (11.4) 3.41 (8.6) 2.53 (6.4) 3.84 (9.7).20 x.40 (0.5 x 1.0) 6.6 (3.0) 250 E01-0250 4.13 (10.4) 4.50 (11.4) 4.03 (10.2) 3.22 (8.1) 3.84 (9.7).20 x.40 (0.5 x 1.0) 9.4 (4.3) 350 E01-0350 5.00 (12.7) 5.25 (13.3) 4.03 (10.2) 3.75 (9.5) 4.50 (11.4).31 x.69 (0.8 X 1.7) 13.0 (5.9) 500 E01-0500 5.50 (13.9) 5.25 (13.3) 4.66 (11.8) 4.28 (10.8) 4.50 (11.4).31 x.69 (0.8 X 1.7) 19.1 (8.7) 750 E01-0750 7.03 (17.8) 5.25 (13.3) 4.66 (11.8) 5.75 (14.6) 4.50 (11.4).31 x.69 (0.8 X 1.7) 26.6 (12.1) GROUP II 200//, 208//, 240/480 PRIMARY VOLTS 23/110, 24/115, 25/120 SEONDARY VOLTS 1Ø, 50/60 Hz 50 E02-0050 3.28 (8.3) 3.28 (8.3) 2.81 (7.1) 2.25 (5.7) 2.81 (7.1).20 x.40 (0.5 x 1.0) 2.7 (1.2) 100 E02-0100 4.03 (10.2) 3.75 (9.5) 3.13 (7.9) 3.22 (8.1) 3.16 (8.0).20 x.40 (0.5 x 1.0) 4.3 (1.9) 150 E02-0150 4.03 (10.2) 4.50 (11.4) 3.41 (8.6) 2.81 (7.1) 3.75 (9.5).20 x.40 (0.5 x 1.0) 6.8 (3.0) 250 E02-0250 4.78 (12.1) 4.50 (11.4) 4.03 (10.2) 4.06 (10.3) 3.75 (9.5).20 x.40 (0.5 x 1.0) 9.7 (4.4) 350 E02-0350 5.53 (14.0) 5.25 (13.3) 4.03 (10.2) 4.28 (10.8) 4.38 (11.1).31 x.69 (0.8 X 1.7) 13.5 (6.1) 500 E02-0500 7.25 (18.4) 5.25 (13.3) 4.69 (11.9) 6.00 (15.2) 4.38 (11.1).31 x.69 (0.8 X 1.7) 19.6 (8.9) 750 E02-0750 6.81 (17.3) 5.28 (13.4) 4.69 (11.9) 5.75 (14.6) 4.44 (11.2).31 x.69 (0.8 X 1.7) 27.0 (12.2) GROUP III 240 x 480 PRIMARY VOLTS 24 SEONDARY VOLTS 1Ø, 50/60 Hz 50 E03-0050 3.00 (7.6) 3.00 (7.6) 2.81 (7.1) 2.25 (5.7) 2.53 (6.4).20 x.40 (0.5 x 1.0) 2.5 (1.1) 75 E03-0075 3.28 (8.3) 3.28 (8.3) 2.81 (7.1) 2.25 (5.7) 2.81 (7.1).20 x.40 (0.5 x 1.0) 3.5 (1.6) 100 E03-0100 3.28 (8.3) 3.75 (9.5) 3.09 (7.8) 2.53 (6.4) 3.13 (7.9).20 x.40 (0.5 x 1.0) 4.0 (1.8) 150 E03-0150 3.88 (9.8) 4.50 (11.4) 3.47 (8.8) 2.53 (6.4) 3.75 (9.5).20 x.40 (0.5 x 1.0) 6.5 (2.9) 250 E03-0250 4.13 (10.4) 4.50 (11.4) 4.03 (10.2) 3.22 (8.1) 3.75 (9.5).20 x.40 (0.5 x 1.0) 9.2 (4.2) 350 E03-0350 5.00 (12.7) 5.25 (13.3) 4.03 (10.2) 3.75 (9.5) 4.38 (11.1).31 x.69 (0.8 X 1.7) 12.7 (5.8) 500 E03-0500 5.53 (14.0) 5.25 (13.3) 4.66 (11.8) 4.28 (10.8) 4.38 (11.1).31 x.69 (0.8 X 1.7) 19.0 (8.6) 750 E03-0750 7.03 (17.8) 5.25 (13.3) 4.66 (11.8) 5.41 (13.7) 4.38 (11.1).31 x.69 (0.8 X 1.7) 26.0 (11.8) 84

AE/E SERIES INDUSTRIAL ONTROL TRANSFORMERS GROUP IV 380/400/415 PRIMARY VOLTS 110/ SEONDARY VOLTS 1Ø, 50/60 Hz 50 E04-0050 3.53 (8.9) 3.00 (7.6) 2.81 (7.1) 2.53 (6.4) 2.53 (6.4).20 x.40 (0.5 x 1.0) 2.6 (1.2) 100 E04-0100 3.53 (8.9) 3.75 (9.5) 3.22 (8.1) 2.53 (6.4) 3.13 (8.0).20 x.40 (0.5 x 1.0) 4.3 (1.9) 150 E04-0150 3.53 (8.9) 4.34 (11.0) 3.41 (8.6) 2.53 (6.4) 3.75 (9.5).20 x.40 (0.5 x 1.0) 6.7 (3.0) 250 E04-0250 4.03 (10.2) 4.50 (11.4) 4.22 (10.7) 3.22 (8.1) 3.75 (9.5).20 x.40 (0.5 x 1.0) 9.4 (4.3) 350 E04-0350 4.91 (12.4) 4.50 (11.4) 4.22 (10.7) 4.06 (10.3) 4.38 (11.1).20 x.40 (0.5 x 1.0) 13.0 (5.9) 500 E04-0500 6.00 (15.2) 5.25 (13.3) 4.69 (11.9) 4.78 (12.1) 4.38 (11.1).31 x.69 (0.8 X 1.7) 18.8 (8.5) 750 E04-0750 6.81 (17.3) 5.25 (13.3) 4.69 (11.9) 5.75 (14.6) 4.38 (11.1).31 x.69 (0.8 X 1.7) 26.0 (11.8) GROUP V 208, /380/, /400/, 240/416/480 PRIMARY VOLTS 85/100/110, 91/110/120, 95/115/125, 99/120/130 SEONDARY VOLTS 1Ø, 50/60 Hz 50 E05-0050 4.03 (10.2) 3.41 (8.6) 3.09 (7.8) 2.47 (6.2) 2.81 (7.1).20 x.40 (0.5 x 1.0) 2.7 (1.2) 150 E05-0150 3.88 (9.8) 4.34 (11.0) 3.41 (8.6) 2.88 (7.3) 3.75 (9.5).20 x.40 (0.5 x 1.0) 6.7 (3.0) 250 E05-0250 5.13 (13.0) 4.50 (11.4) 4.03 (10.2) 4.38 (11.1) 3.75 (9.5).20 x.40 (0.5 x 1.0) 9.5 (4.3) 350 E05-0350 5.91 (15.0) 5.25 (13.3) 4.03 (10.2) 4.78 (12.1) 4.38 (11.1).31 x.69 (0.8 X 1.7) 13.3 (6.0) 500 E05-0500 5.91 (15.0) 5.25 (13.3) 4.66 (11.8) 4.63 (11.7) 4.38 (11.1).31 x.69 (0.8 X 1.7) 19.0 (8.6) 750 E05-0750 7.09 (18.0) 5.25 (13.3) 4.66 (11.1) 5.81 (14.7) 4.38 (11.1).31 x.69 (0.8 X 1.7) 27.0 (12.2) GROUP VI 240 x 480, x, x PRIMARY VOLTS 120/115/110 SEONDARY VOLTS 1Ø, 50/60 Hz 50 E06-0050 3.41 (8.6) 3.00 (7.6) 2.81 (7.1) 2.53 (6.4) 2.53 (6.4).20 x.40 (0.5 x 1.0) 2.6 (1.2) 75 E06-0075 3.41 (8.6) 3.28 (8.3) 2.81 (7.1) 2.53 (6.4) 2.81 (7.1).20 x.40 (0.5 x 1.0) 3.6 (1.6) 100 E06-0100 3.41 (8.6) 3.75 (9.5) 3.09 (7.8) 2.53 (6.4) 3.13 (7.9).20 x.40 (0.5 x 1.0) 4.3 (1.9) 150 E06-0150 3.88 (9.8) 4.50 (11.4) 3.47 (8.8) 2.53 (6.4) 3.75 (9.5).20 x.40 (0.5 x 1.0) 6.7 (3.0) 250 E06-0250 4.13 (10.4) 4.50 (11.4) 4.03 (10.2) 3.22 (8.1) 3.75 (9.5).20 x.40 (0.5 x 1.0) 9.4 (4.3) 300 E06-0300 4.53 (11.5) 4.50 (11.4) 4.03 (10.2) 3.75 (9.5) 3.75 (9.5).20 x.40 (0.5 x 1.0) 10.9 (4.9) 350 E06-0350 5.00 (12.7) 5.25 (13.3) 4.03 (10.2) 3.75 (9.5) 4.38 (11.1).31 x.69 (0.8 X 1.7) 13.0 (5.9) 500 E06-0500 6.00 (15.2) 5.25 (13.3) 4.66 (11.8) 4.78 (12.1) 4.38 (11.1).31 x.69 (0.8 X 1.7) 18.8 (8.5) 750 E06-0750 6.81 (17.3) 5.25 (13.3) 4.66 (11.8) 5.75 (14.6) 4.38 (11.1).31 x.69 (0.8 X 1.7) 26.0 (11.8) 85

AE/E INDUSTRIAL ONTROL TRANSFORMERS FUSE SIZING HARTS PRIMARY FUSE SIZING HARTS REOMMENDED RATING FOR URRENT LIMITING LASS FUSES 120 V 208 V V V 240 V 380 V 400 V 416 V V V 480 V 500 V 550 V 575 V 600 V 50 VA 1.25 0.60 0.60 0.60 0.60 0.30 0.30 0.30 0.30 0.30 0.30 0.30 0.25 0.25 0.25 75 VA 1.80 1.00 1.00 0.80 0.80 0.50 0.50 0.50 0.50 0.40 0.40 0.40 0.40 0.30 0.30 100 VA 2.50 1.40 1.25 1.25 1.25 0.75 0.75 0.60 0.60 0.60 0.60 0.60 0.50 0.50 0.50 150 VA 3.50 2.00 2.00 1.80 1.80 1.13 1.13 1.00 1.00 0.80 0.80 0.80 0.80 0.75 0.75 250 VA 3.20 3.50 3.20 3.20 3.00 1.80 1.80 1.80 1.60 1.60 1.50 1.50 1.25 1.25 1.25 300 VA 4.00 4.00 4.00 3.50 3.50 2.25 2.25 2.00 2.00 1.80 1.80 1.80 1.60 1.50 1.50 350 VA 4.50 5.00 4.50 4.50 4.00 2.50 2.50 2.50 2.25 2.25 2.00 2.00 1.80 1.80 1.60 500 VA 6.25 4.00 3.50 3.50 3.20 3.50 3.50 3.50 3.20 3.20 3.00 3.00 2.50 2.50 2.50 750 VA 10.00 6.00 5.60 5.00 5.00 5.60 5.60 5.00 5.00 4.50 4.50 4.50 4.00 3.50 3.50 NOTE: Bold lines indicate changes in the percent of rated current used to calculate fuse sizes in accordance with article 450 of the NE. SEONDARY FUSE SIZING HARTS REOMMENDED RATING FOR URRENT LIMITING MIDGET FUSES 24 V 85 V 91 V 95 V 99 V 100 V 110 V 115 V 120 V 125 V 130 V 50 VA 2.00 0.50 0.50 0.50 0.50 0.50 0.50 0.50 0.50 0.50 0.25 75 VA 3.00 0.75 0.75 0.75 100 VA 5.00 1.00 1.00 1.00 150 VA 6.00 2.00 2.00 1.50 1.50 1.50 1.50 1.50 1.50 1.50 1.00 250 VA 12.00 3.00 3.00 3.00 3.00 3.00 2.00 2.00 2.00 2.00 2.00 300 VA 3.00 3.00 3.00 350 VA 15.00 5.00 4.00 4.00 4.00 4.00 3.00 3.00 3.00 3.00 3.00 500 VA 25.00 6.00 6.00 6.00 6.00 6.00 5.00 5.00 5.00 5.00 4.00 750 VA 35.00 10.00 10.00 8.00 8.00 8.00 8.00 8.00 6.00 6.00 6.00 ONNETION DETAILS FOR AE05 & E05 - - - - -X3 -X4 208 85 100 110 380 91 110 120 400 95 115 125 240 416 480 99 120 130 86

5 SETION AE/E INDUSTRIAL ONTROL TRANSFORMERS FUSE KITS & AESSORIES ATALOG NUMBER VA DESRIPTION APPROX. SHIPPING WT. (Lbs./ Kg.) PL-79920 50-750 PL-79921 150-750 PL-79922 50-750 PL-79923 Fuse Kit: Primary Fuse Block EI Series (2 lass Blocks) Fuse Kit: Primary & Secondary Fuse Block EI Series (2 lass and 1 Midget Blocks) Fuse Kit: Primary Fuse Block EI Series E Listed w/ overs (2 lass Blocks) Fuse Kit: Primary & Secondary Fuse Block EI Series 150-750 E Listed w/ overs (2 lass and 1 Midget Blocks) 1.0 (0.5) 1.0 (0.5) 1.0 (0.5) 1.0 (0.5) PL-79924 Fuse Kit: Secondary Fuse 1/4 x 1-1/4 w/arm 1.0 (0.5) PL-79925 50 350 over: Small Terminal overs (Qty. 2) 1.0 (0.5) PL-79926 500 & 750 over: Large Terminal overs (Qty. 2) 1.0 (0.5) PL-79927 over: Fuse Block overs (Qty. 1) 1.0 (0.5) PL-79928 50 350 Link: Small Jumper Links (Qty. 2) 1.0 (0.5) PL-79929 500 & 750 Link: Large Jumper Links (Qty. 2) 1.0 (0.5) PL-79930 50 350 Fuse Kit: Secondary Fuse Midget w/arm 1.0 (0.5) PL-79931 500 & 750 Fuse Kit: Secondary Fuse Midget w/arm 1.0 (0.5) AE & E Series Wiring Diagrams WIRING FOR AE01 & E01 WIRING FOR AE02 & E02 WIRING FOR AE03 & E03 WIRING FOR E04 240V 120V 208 200 240 480 480V 240V 380 400 415 24V X3 120 115 110 25 24 23 WIRING FOR AE05 & E05 WIRING FOR AE06 & E06 WIRING FOR AE07 WIRING FOR AE12 24V X4 X4 110V X3 X3 X4 X3 V 240V 208 416V 400 380 480V 600V 575 550 500 H5 480V 240V 208V V V 240V 480V 600V 575 550 120V 115 130V 110 125 100 120 110 X4 X3 99V 95 91 85 120V 115 110 115V X3 120V 115 110 100V 95 90 AE & E Series Dimensional Drawings B E F D A 87