User Guide. Indoor Air Quality Meter/Datalogger. Model EA80

Similar documents
Indoor Air Quality Meter/Datalogger

User's Guide. Digital Psychrometer. Model RH390. F C WBT Dew Point MAX MIN

Auto-timer Datalogging Temperature / Humidity Meter

User Manual. Thermocouple Datalogging Thermometer. Model EA15

User's Guide. EasyView K-Type Thermometer. Model EA11A

USER MANUAL. Hygro-Thermometer. Model RHT510. Additional User Manual Translations available at

Hygro-Thermometer / Datalogger

Moisture Content Meter Plus Dew Point, Wet Bulb, and Thermocouple Temperature functions

1366 INSTRUCTION MANUAL

ph/orp Meter SD Card real-time Datalogger

Dual Moisture Meter Pin / Pinless Moisture Meter

USER MANUAL. Light Meter. Model LT510. Additional User Manual Translations available at

USER GUIDE. Dual Input True RMS AC Voltage/Current Datalogger. Model DL160

USER GUIDE. 3 Channel DC Current Datalogger Model SD900

4-Channel Thermometer / Datalogger

SuperHeat Psychrometer Models RH350 and RH355 (kit)

User's Guide. Datalogging Hygro-Thermometer Model SD500

USER GUIDE. Heavy Duty Digital Light Meter with PC Interface. Model HD400

Light Meter SD Card real-time datalogger

Heavy Duty Datalogging Light Meter

RS Stock No Instruction Manual RS Input Data Logging Thermometer

Datalogging Hygro-Thermometer

12-Channel Thermocouple Datalogger

User's Guide. Hot Wire Thermo-Anemometer. Model

USER MANUAL. Heavy Duty Manifold Pressure Gauge. Model HD780. Additional User Manual Translations available at

User's Guide. 3 Channel Datalogging Thermometer Model SD200

Vibration Meter SD Card real-time datalogger

Humidity & Temperature Datalogger

Datalogging Hygro-Thermometer

Sound Level Meter SD Card real-time Datalogger

USER GUIDE Turbidity Meter Model TB400

Model A Mini AC/DC Clamp Meter. User's Guide

User's Guide. Barometric Pressure / Humidity and Temperature Datalogger Model SD700

USER GUIDE. Coating Thickness Tester. Model CG104

3 Channel Datalogging Thermometer

User Guide. Conductivity Meter. Model EC210

User Manual. Heavy Duty Differential Pressure Manometer. Model SDL720. Additional User Manual Translations available at

Barometric Pressure / Humidity and Temperature Datalogger

4-Channel Vibration Datalogger

USER GUIDE. Differential Thermometer Datalogger. Model HD200

Model A Current / Voltage Calibrator. User's Guide

User Manual. Heavy Duty Hot Wire CFM Thermo-Anemometer. Model

Heat Stress WBGT Meter

Large Vane CFM/CMM Anemometer / Psychrometer

User's Guide. Extech CG204 Coating Thickness Tester. 99 Washington Street Melrose, MA Phone Toll Free

USER GUIDE. AC/DC Magnetic Meter. Model MF100

User Manual. 400Amp AC Clamp Meter + NCV. Model MA430. Additional User Manual Translations available at

USER GUIDE. Heavy Duty Differential Pressure Manometer. Model HD700

Digital Sound Level Meter

Model A Current Calibrator. User Guide

Personal Sound Level Meter

User's Guide. 800 Amp Clamp Meters. EX710 AC Clamp meter EX720 True RMS AC Clamp meter EX730 AC/DC True RMS Clamp meter

Humidity & Temperature Datalogger

User Manual. Thermohygrometer. Model with NIST-Traceable Calibration THE STANDARD IN PRECISION MEASUREMENT

Vibration Meter and Laser Combination Tachometer

Heavy Duty Vibration Meter

Earth Resistance and Resistivity Tester

USER GUIDE Current Calibrator

Formaldehyde Thermo-Hygrometer

User Manual. Dual-Input Data Logging Thermometers. with NIST-Traceable Calibration. Thermocouple Meter, Type J/K/T Input Model

Coating Thickness Tester

Large Vane CFM/CMM Thermo-Anemometer

User's Guide. Cup Thermo-Anemometer. Model AN400

RS Stock No Instruction Manual RS Input Data Logging Thermometer

Heavy Duty Pitot Tube Anemometer and Differential Pressure Manometer

Heavy Duty Datalogging Light Meter

Humidity + Temperature + Pressure Datalogger

11 in 1 Environmental Meter

User's Manual. Autoranging Datalogging Insulation Tester (Megohmmeter) with PC Interface. Model

USER MANUAL Video Particle Counter with built in Camera Model VPC300

True RMS AC Voltage/Current Datalogger

User Guide. Moisture Meter. Model MO250

Datalogging IAQ Meter Instruction Manual

USER GUIDE. Video Particle Counter with built in Camera. Model VPC300

User's Guide. Digital Multimeter. Model MN42

HDT-318 Thermo-Hygrometer with Data Logger. (Air Humidity/Temperature) Instruction Manual

Extech EX820 True RMS 1000 Amp Clamp Meter with IR Thermometer. User's Guide

USER GUIDE. Video Particle Counter with built in Camera. Model VPC300

Heavy Duty Datalogger Module

User's Guide. Humidity + Temperature + Pressure Datalogger. Model RHT50

APO F T1 F T1-T2 ESC - 0 ENTER. [Limits] CLR? SET[ ] LOG READ SAVE READ SHIFT [OFS] [APO] MAX/MIN REL HOLD [TIME] T1-T2 TYPE T1/T2 TYPE T1/T2

Mini Digital Multimeter

Coating Thickness Tester

USER GUIDE. Noise Dosimeter with PC Interface. Model

Coating Thickness Tester

Integrating Sound Level Datalogger Model

User Manual. Single-Input Thermometers. with NIST-Traceable Calibration. Thermocouple Meter, Type J/K/T Input Model

Dual Input, 3-Display Thermometer/Datalogger Model

User Manual. Single-Input Thermometers. with NIST-Traceable Calibration. Thermocouple Meter, Type J/K/T Input Model

Video Borescope Inspection Camera

Heavy Duty Hot Wire CFM Thermo-Anemometer

User Guide True RMS Multimeter Extech EX205T

3-Phase Power Analyzer/Datalogger

Thermocouple Calibrator

USER MANUAL. Mini Multimeter with Non-Contact Voltage Detector (NCV) Model EX310

HH-521BT 4-Channel Thermocouple Data Logger (with Bluetooth) (Types K, J, T, N, E, R, S) Instruction Manual

Heavy Duty Datalogger Module

User s Manual. Models Digital Force Gauge. Additional User Manual Translations available at

CENTER 521 INSTRUCTION MANUAL 4-Channel Thermocouple Data Logger (with Bluetooth) (Types K, J, T, N, E, R, S)

Heavy Duty Psychrometer + IR Thermometer Model HD500

Transcription:

User Guide Indoor Air Quality Meter/Datalogger Model EA80

Introduction Congratulations on your purchase of the Extech EA80 Indoor Air Quality Meter. This meter measures Carbon Dioxide (CO 2, ppm) levels, ambient Temperature and Relative Humidity (%RH). 16,200 readings can be logged by the meter and later transferred to a PC. This meter is shipped fully tested and calibrated and, with proper use, will provide years of reliable service. Description 1. Display 2. Gas exhaust 3. Gas inlet port 4. PC Interface jack 5. AC adapter socket (9V, 300mA) 6. Power Button 7. Data Hold Button 8. Backlight Button 9. MX/MN Button 10. SET Button 11. ALARM button 12. MEM (memory) button 13. (Enter) button 14. READ button 15. TIME button 16. C/ F button 17. DEW button 18. WET button 19. Temperature / Humidity sensor probe AC Adaptor 2.5mm mono Plug Ø2.5 Three Tier LCD Display 2

Preparation for Use Power Supply The meter is powered by six (6) 1.5V AAA alkaline batteries or by an AC adapter. Installing the Batteries Insert six (6) AAA batteries as indicated by the diagram located on the inside of the battery compartment. When the battery voltage drops below the operating voltage, the + indicator will be displayed indicating that the batteries need to be changed. AC Adapter The AC adapter allows the meter to be powered from a common AC wall outlet. When using the AC adapter, the batteries (if installed) will be bypassed. The AC adapter is not a battery charger. Gas Inlet Always ensure that the meter s gas inlet port and gas exhaust are not blocked. Operation Note: Exhaled CO 2 will affect the accuracy of the reading; do not hold meter near the face. Taking Measurements The sensor for Temperature, Humidity, Dew Point, and Wet Bulb measurements is located in the remote probe. Hold the probe in the air in the area to be tested. DO NOT immerse in liquid. The sensor for CO2 measurements is located at the top of the meter. Selecting temperature units of measure (C/F) Press the C/ F button momentarily to toggle the temperature units. CO2 Measurement 1. Press button to turn on the meter, 2. The sensor requires a 30 second warm-up before displaying the CO2 measurement. 3. The meter sensor requires approximately10 minutes to stabilize in still air before the readings can be considered accurate. Moving the meter may decrease this stabilization time. 4. The primary display indicates the CO2 reading. The secondary display indicates temperature. The third display indicates %RH. 3

Humidity Measurement 1. Press the button to power the meter ON. 2. The display will indicate the humidity reading (% RH) directly on the third display. 3. Hold the probe in the air in the area to be tested. Do NOT immerse in liquid. 4. Allow adequate time for readings to stabilize. 5. Read the measurements on the LCD. Temperature Measurement 1. Press the button to power the meter ON. 2. Press the C/ F button momentarily to toggle the temperature units. 3. The display will show the Temperature reading directly on the second display. 4. Allow adequate time for readings to stabilize. 5. Read the measurements on the LCD. Dew Point Temperature Measurement 1. Press the button to power the meter ON. 2. Press the DEW button 3. The display will show the Dew Point Reading on the second display. 4. Allow adequate time for the readings to stabilize 5. Read the measurements on the LCD. 6. Press the DEW button again to exit the dew point temperature reading. Wet Bulb Temperature Measurement 1. Press the button to power the meter ON. 2. Press the WET button 3. The display will show the Wet Bulb Reading on the second display. 4. Allow adequate time for the readings to stabilize 5. Read the measurements on the LCD. 6. Press the WET button again to exit the display. 4

CO 2 Maximum and Minimum Recording Measurement 1. Press MX/MN button to enter the maximum / minimum recording mode, the MAX icon appears on the display. The maximum CO2 reading will be displayed and will be updated only when a higher reading occurs. 2. Press TIME button to enter time display mode. Displays 2 and 3 will indicate the time the maximum reading occurred. 3. Press MX/MN button again. The MIN icon will appear with the minimum value and its stamp time. 4. Press MX/MN button again. The icon will appear with the current value and current time. 5. Press MX/MN button again cycle through the recorded MAX, MIN and current readings. 6. Press button to exit this mode. 7. Press TIME button exit the time display mode. MAX m:s MIN m:s 8 CO2 d-h CO2 d-h ppm ppm CO2 ppm m:s d-h Data Hold 1. Press the H button momentarily to freeze the displayed reading. The 'H' icon will appear on the upper left-hand side of the display. 2. Press the H button again to return to normal operation (the 'H' hold icon will disappear). SET MAX MIN ALM 88 8888 R M Err INTV 8888 8888 CO2 m:s DEW C F WET ppm CAL CO2 d-h %RH ppm Backlight 1. Press the button to turn the backlight on or off. 2. The backlight will turn off automatically after 30 seconds. 5

CO 2 Alarm Operation Setting the Alarm Limit Values 1. Press ALARM button to turn on the alarm function, the ALM icon, and current value are displayed. 2. Press SET button to enter High/Low limit value setting mode, the SET icon is displayed and hundred and thousand digits of the high limit value SET ALM will flash. 3. Press or button to set desired value. 4. Press button to move the cursor to set the tens and ones digits. 5. Press or button to enter the desired value. 6. Press button to move the cursor to the hundred and thousand digits of the low limit value. 7. Press or button to set desired value. 8. Press button to move the cursor to move the cursor to set the tens and ones of the low limit value. 9. Press or button to set desired value. 10. To change any setting, press or button to move the cursor to desired high or low limit value position. 11. Press button to store these setting and exit this mode. Turning Alarm On / Off 1. Press ALARM button to turn on the alarm function, ALM is displayed. 2. When the CO 2 value is below the low limit value, the meter displays mark and beeps. 3. When the CO 2 value exceeds the high limit value, the meter displays and beeps. 4. To exit the ALARM function, press ALARM button again. Setting the Real Time Clock 1. Press SET button to enter the real-time clock SET MAX MIN CAL setting mode, SET is displayed and the minutes ALM are flashing. 2. Press or button to set the minutes. 8888 R M88 Err INTV 3. Press button to move the cursor to seconds. DEW 4. Press or button to set the seconds. 8888 8888 C F WET 5. Press button to move the cursor to days. CO2 m:s ppm CO2 d-h %RH ppm 6. Press or button to set the day of the real time date. (Please note that this is not a calendar. Days are elapsed days up to 99 total) 7. Press button to move the cursor to the hours. (Please note that this is a 24 hour clock) 8. Press or button to set the hours. 9. To change any setting, press or button to move the cursor to desired position. 10. Press button to store the settings and exit this mode. 6

Manual Datalogging Storing readings Press the "MEM" button. The LCD will display "M" and memory address number. The total memory size is 99 readings. SET MAX MIN Viewing readings DEW Press the "READ" button to enter READ mode. The LCD C F WET will CO2 m:s ppm CO2 d-h %RH ppm display "R" and the memory address number. Press " " or " " to scroll through the stored readings. Press " " enter to exit this mode. Deleting stored data Press the SET button three times. The LCD will display CLr and the meter will enter the Clear Memory mode. Press to clear the all manually stored readings. To abort, press the SET button twice and then press the button to exit the Clear Memory mode. ALM 88 8888 R M Err INTV 8888 8888 CAL the Auto Datalogging Setting interval time Press SET two times. The INTV mark will appear and the meter will enter the Interval Time setting mode. Use the or button to select the desired interval time from 1 to 255 seconds. Press the button to store the value and to exit the mode. Auto Datalogging mode Press and hold MEM for two seconds (3 beeps), the LCD will display the icon and the memory location. The M will flash each time a recording is made. The maximum memory capacity is 16,200 recordings that can be divided into 99 sets. Press the button to exit this mode and to stop recording. Deleting Logged Data Press SET four times, the CLr and mark will be displayed. Press the button to clear the automatically stored data and to exit this mode. To abort, press the SET button again then press the button to exit. 7

Calibration CO2 Calibration 1. Press to turn the meter on. 2. Place the probe in a known CO2 reference for 10 minutes. 3. Press the SET button 5 times until C-01 is displayed in the second display. 4. Press or to select digits to adjust (flashing). 5. Press or to adjust the display to the reference value. 6. Press to store the value and exit the calibration mode. Humidity Calibration 1. Press to turn the meter on. 2. Place the probe in a known humidity reference for 60 minutes. 3. Press the SET button 6 times until SET and CAL are displayed on the LCD. 4. Press or to adjust the display to the reference value. 5. Press to store the value and exit the calibration mode. Temperature Calibration 1. Press to turn the meter on. 2. Place the probe in a known temperature reference for 60 minutes. 3. Press the SET button 7 times until SET and CAL are displayed on the LCD. 4. Press or to adjust the display to the reference value. 5. Press to store the value and exit the calibration mode. 8

Specifications Display Three Tier LCD Display Rate One reading per second Low Battery Indication The + icon is displayed when the battery voltage drops below the operating voltage Power Supply Six (6) AAA-size alkaline batteries or AC adapter (120V) Battery Life Approx. 8 hours using alkaline batteries (with backlight and Alarm functions OFF) Manual Data Memory Capacity 99 records Auto Datalogging Capacity 16,200 records in up to 99 data sets Operating Temperature Range 5 C to 50 C (41 F to 122 F) Storage Temperature Range -10 C to 60 C (-14 F to 140 F) Operating Humidity Range 10%RH to 90%RH, non-condensing Storage Humidity Range 10%RH to 90%RH, non-condensing Dimensions 158 (L) x 72(W) x 35(H) mm (6.22 x 2.83 x 1.38 ) Weight 255g (0.56 lbs) approx. (including batteries) Accessories Instruction Manual, Batteries, AC Adaptor, Software CD ROM, and PC Interface Cable CO2 Specifications Sensing Range Sensing Resolution Accuracy Sensing Method Gas Sampling Mode Warm up time Response time Temperature Coefficient 0 to 6000ppm 1ppm 3% of reading or 50ppm, whichever is greater @ 101.4 kpa (29.92 inhg) and @ 25 C (77 F) Dual wavelength detector with non- dispersive infrared (NDIR) sensor Diffusion type 10 seconds < 10 minutes in still air Add 0.36% of reading per C ( 0.2% of reading per F) when deviating from calibration temperature Temperature & Humidity Specifications Relative Humidity Temperature Range 10% ~ 95% RH -20 C ~ +60 C (-4 C ~ +140 F) Resolution 0.1% RH 0.1 C (0.1 F) Accuracy 3%RH @ 25 C(77 F), 30~95%RH) 5%RH @ at 25 C(77 F), 10~30%RH) 0.5 C ( 0.9 F) Sensor type Precision capacitance sensor Thermistor Response time 45%RH 95%RH 1min 95%RH 45%RH 3min 10 C / 2sec 9

Maintenance Cleaning Periodically wipe the case with a dry cloth or a damp cloth with mild detergent. Do not use abrasives or solvents to clean this instrument. Battery Replacement When the symbol appears on the LCD, the six 1.5V AAA must be replaced. 1. Turn the meter off 2. Remove the meter s rubber protective jacket 3. Remove the flat-head screw at the rear of the meter 4. Remove the meter s battery cover 5. Replace the batteries observing polarity 6. Affix the battery cover, secure the rear screw, and re-attach the meter s rubber protective jacket You, as the end user, are legally bound (Battery ordinance) to return all used batteries and accumulators; disposal in the household garbage is prohibited! Bring used batteries / accumulators to the collection points in your community or wherever batteries / accumulators are sold! PC Interface, Software Installation and Operation Software operational instructions are located on the software disc. Install the software by inserting the disc in the PC CD-ROM drive and following the on-screen prompts. Open the Software manual (PDF) and read the Installation and Operation instructions. Copyright 2013 2015 FLIR Systems, Inc. All rights reserved including the right of reproduction in whole or in part in any form ISO 9001 Certified www.extech.com 10