Revenue Grade NEMA 4X THE BYRAM. Electric Meter

Similar documents
Series 3000 User Manual and Product Features

Metered Rack PDU Rack PDU, Metered, Zero U, 10A, 230V, (16) C13

PowerLogic EM4000 series

A3 ALPHA Meter. Electronic Meter for Electric Energy Measurement. TM B US English (en)

Metered Rack PDU Rack PDU, Metered, Zero U, 5.7kW,208V,(36)C13& (6)C19; 10' Cord

ACUREV Three-Phased DIN-Rail Multifunction Meter FEATURES

Metered Rack PDU Rack PDU, Metered, Zero U,12.5kW,208V,(30)C13, (6)C19; 10' Cord

Power Xpert Meter 350 (PXM350) three-phased DIN-rail multifunction meter

AcuRev Multi-Circuit Power and Energy Meter. Shop for Accuenergy products online at:

EM-1000 /EM-2000/ EM-3000 Series Multifunction Power and Energy Meters

MID PRELIMINARY DATA SHEET. RI-D Series. Single Phase Multifunction Energy Meter (MID Certified) MID

Technical data sheet. PowerLogic power-monitoring units EM3500 series DIN Rail meter

Metered Rack PDU Rack PDU, Metered, Zero U, 20A, 120V, (24) NEMA 5-20R

Energy meters Single phase electrical energy meters WM1-6 / WM1M6

Power Meter PowerMonitor 500

Surge Protective Devices. STV100K Series. Instruction Manual

Surge Protective Devices. STV100K Series. Instruction Manual

Multilin EPM Energy and Demand Submeter with Wi-Fi. Monitoring & Metering. Communications. Key Benefits. Applications

MAXIOM. Data Sheet. Lighting Relay Panel. Overview Leverage the Power of BAS Integration

AcquiSuite Ally 48 Advanced Branch Circuit Monitor

OHIO SEMITRONICS, INC. AC MULTIFUNCTION PROGRAMMABLE TRANSDUCERS & -1000L

AcuRev 2000 Multi-Circuits Networked Multifunction Power and Energy Meter

EngyVolt RV12 and RV15

EM132 EM132. Main Features. Multi-functional 3-Phase Transducer. Energy Meter

Configurable power distribution

em4 Accessories Digital expansions

Electronic Submeter with Advanced WiFi Ethernet Capability

BFM-II BFM-II BRANCH FEEDER MONITOR. Highlights

IIM Warwick Court. Williamsburg VA REV 5

Rapidus Power Factor Controller

Multi-Point Gas Detection and Control System

DTS 310. DIN Rail Mounted, Indoor Rated Revenue Grade Electrical Sub-meter. Page 1. Measurlogic MQ A

Simple Electrical Utility Cost Allocation Solutions

MIC-2 MKII, Multi-instrument DATA SHEET

Rugged MediaConverter

MIC-2 MKII & MIC-2 MKII DIN, Multi-instrument DATA SHEET

Residential Storage Solution for North America. Accessory: Rapid Shut-down System (RSS) Features:

Data Sheet. Digital Multifunctional Power Meter with LCD Display and Optional Modules WPM D

INSTALLATION DKM-409 NETWORK ANALYSER WITH HARMONIC MEASUREMENT AND SCOPEMETER. Before installation:

SLI 15 Inverter Series Data Sheet 1500 Watt, 1U Compact Inverters

DANGER DANGER: is used in this manual to warn of high voltages capable of causing shock, burns, or death.

LXEM145 SERIES Lanx Australis single Phase KWh Meter 45Amp. User manual

LED Driver Linear / area fixed output

MIC-2 Multi-instrument DATA SHEET

Multi-Point Gas Detection and Control System

LED Driver Linear / area fixed output

See instructions to download and install the latest version of LinkBoxLON and the user's manual at

Features. Applications and Benefits TRC ELECTRONICS, INC

Gelo LED Driver 100W, Single output RGLD100-24

Always "On" UPS Systems Inc. USER MANUAL

CITY OF BOISE SPECIFICATIONS FOR LIGHT EMITTING DIODE (LED) STREET LIGHTING Effective 1 Feb, 2018

LED Driver Linear / area fixed output

Multi-Point Gas Detection and Control System

SLI 15 INVERTER SERIES, 1500 W

PRO1250D CT MID DIN rail three phase four wire energy meter. User manual Version 1.5

SEL-734B Data Sheet. Advanced Monitoring and Control System. Major Features and Benefits

REQUIREMENTS FOR WIRELESS, WEB-BASED MONITORING EQUIPMENT AND SERVICES FOR PUMP STATION APPLICAITONS

PRO-1250D CT MID DIN rail three phase four wire energy meter.

*Approved by CSA for non-hazardous locations (Group Safety Publication IEC Third Edition).

MODULAR CIRCUIT MONITORING SYSTEM

SECTION ( ) LIGHTING CONTROL PANELBOARD

Xitanium Highbay LED Drivers Dimmable (1-10V) Independent

DEIF A/S. MIC Multi-instrument G. Data sheet. Features. Accuracy. Measurements. Installation. Intelligent. Display. Communication DEIF A/S

Gelo LED Driver 100W, Single output, Constant Voltage RGLD100-24

LED Driver Linear / area fixed output

Surge Protective Devices Installation, Operation and Maintenance Manual. LoadTrack LTL

Installation, Testing, and Operating Procedures 30 AMP PORTABLE AND PERMANENT SERIES GFCI SINGLE and MULTIPHASE

Powered to Perform. Everyday Reliability. Exceptional Value. Expertise and Support

LED Driver. Xitanium SR 150W V 0.7A SR XI150C070V235VSF1. Specifications. Wiring Diagram. Enclosure. Input and output use lead-wires.

THE SURGE PROTECTION SOLUTION

LineScope. Smart Power Monitor. Bulletin DB50C18. US Patent Nos , , and B2

FLL.RGBW. Noribachi Product Family Brochure and Specifications. Noribachi.com /

APC Matrix-UPS 3kVA 208V/240V In 120/208/240V Out

PDI Modular Compact Remote Power Panel

SECTION ELECTRIC METERING

LED Driver Linear / area fixed output

LED Driver Linear / area fixed output

Surgelogic Surge Protective Device I-Line Plug-On Unit Series

Micro-Ohmmeter. Digital 200A. Model Measure low resistance with high accuracy

Xitanium Highbay LED Drivers Dimmable (1-10V) Independent

9.3. Metering Devices, Protective Relays, Software and Connectivity

EM133 EM133 TOU SMART ENERGY METER. Main Features. Multifunctional 3-Phase Smart Meter. Billing/TOU Energy Meter

Xitanium Highbay LED Drivers Dimmable (1-10V) Independent

Part Numbers SNAP-IT-EMU1

NEW ERA METER. Installation & Operation Guide NE METER

LED Driver Linear / area fixed output

Preliminary. LED Driver. Xitanium SR 75W V 0.7A SR XI075C070V118VSY1. Specifications. Enclosure. Wiring Diagram 1.50"

PLT. Breaker-based transfer switch open, closed or soft transition amps. Specification sheet

Voltage Transducer UMT516 / MT516

Features. ! Single vector/bi vector/tri vector measurement! Time of day metering with maximum demand registration

SDM120 SERIES. SDM120 series User Manual. Single phase two wire DIN rail energy meter (One module)

7511 / / / 711 / / 731 / Preset 27

FFC SERIES CONTRACTORS

ACUREV 2000 Multi-Circuits Networked Multifunction Power Energy Meter

Ultra-small U-shaped Micro Photoelectric Sensor. Extremely small size enables space saving!! 12 mm in

PM-24 SERIES. Ultra-small U-shaped Micro Photoelectric Sensor. Extremely small size enables space saving!! ( ) Equipped with two independent outputs

LED Driver Linear / area fixed output

SAMSUNG ELECTRO-MECHANICS CO., LTD

RTU560. CT/VT Interface 560CVT10. Meter Operation. Application. Characteristics. Data Sheet CT/VT Interface 560CVT10. Instantaneous Meter Values

SECTION SWITCHBOARDS

Transcription:

Meets ANSI and IEC Standards Quick and Easy to Install Revenue Grade NEMA 4X THE BYRAM Electric Meter Tenant Billing Multi-Family Commercial Office & Retail Industrial & Manufacturing Educational Government www.byramlabs.com 1.800.766.1212

Index Why Sub-Metering?...2 - Cost Allocation...2 - Tenant Billing...2 Meter Attributes...3 - Revenue Grade...3 - Demand Intervals...3 - Bi-Directional Capabilities...3 - Wide Voltage Range...3 Byram s Electric Meters...4 - Features...4 - Limited Warranty Information...4 - Meter Kit Contents...4 Single Phase/Residential Meter...5 - Specifications...5 - Part Numbers/Ordering Details...5 Meter/CT Dimensional Drawings...6 Three Phase, Three Wire/Commercial & Industrial Meter...7 - Specifications...7 - Part Numbers/Ordering Details...8 Three Phase, Four Wire/Commercial & Industrial Meter...9 - Specifications...9 - Part Numbers/Ordering Details...10 Polyphase Meter Dimensional Drawings...11 Current Transformer Dimensional Drawings - BL-2 Series...12 - BL-3 Series...13 - BL-4 Series...13 - BL-5 Series...14 - BL-6 Series...14 Installation Diagrams - Single Phase, Two Wire...15 - Single Phase, Three Wire...16 - Three Phase, Three Wire... - Three Phase, Four Wire... 1910-2015 Serving the electrical industry for 105 years Patent pending. Information contained herein is subject to change without notice. Product specifications may change. Contact your Byram representative for the most current product information. Printed in the United States. 1

Sub-Metering Sub-metering is the most accurate and widely used method of recovering variable utility costs. It is a proven, cost effective and easy to implement method to recover electric expenses. Properties benefit from: Accurate energy monitoring, real-time energy consumption Ability to identify and eliminate wasted energy Reduced variable utility costs Improved net operating income Increased property value Cost Allocation Metering individual departments, areas or buildings for cost center analysis, budgetary accountability and allocation allows visibility into energy consumption and usage trends. With this knowledge, managers are able to take advantage of new energy savings opportunities. When department budgets include energy consumption, users will be more inclined to take the necessary steps to reducing overall energy usage. Tenant Billing In facilities where there are multiple tenants, monitoring actual consumption is a win-win situation for both the building manager and the tenants. Managers are able to allocate energy usage costs directly to the tenants. Energy costs can include not only electric, but gas, water and BTU costs as well. In addition, all common area usage can be monitored and distributed equitably between tenants. Both tenant billing and common area allocation allows building managers to recoup energy expenses. Tenants benefit from sub-metering of actual energy usage in two ways. First, tenants only pay for what they use. They are not burdened with the overflow cost of large users as they would be if billed a flat rate per square foot of space rented. The second benefit is that they gain control over their usage allowing them to conserve energy and benefit financially for their efforts. Whether metering a commercial or residential tenant, department or common area, cost allocation and accurate billing practices help reduce costs, recoup energy expenses and promote energy conservation. Condo Multi-Family Student Housing Hospital Restaurant Theater Duplex Municipal Franchise/Chain Residential High Rise Apartments 2

Revenue Grade Byram s meters meet IEC 62052-21 and 62053-21 standards of compliance, as well as ANSI C12.19 and C12.22 accuracy requirements for accuracy class 0.2% These meters are sufficient for the purposes of electric utilities and are, therefore, revenue grade meters. Beyond just accuracy, Byram s meters meet additional requirements: Capable of separately recording bi-directional energy flows Visible display to support self-meter reading by the end user Demand Intervals Demand meters record the highest average kilowatts consumed and maintained over a 15-minute interval during any given billing period. For properties where electrical demand is high, Byram s demand meters are the first step to tracking and managing your demand, saving you money on your electric bill. Bi-Directional The bi-directional meter installed for Byram metering customers records the power flowing in two directions. It measures how much electricity you use from your utility company and how much electricity your system supplies to the utility s energy grid. Each billing period, the power from the utility company you use is offset by the power you send to the utility. This feature is imperative to systems where a solar array is deployed. Wide Voltage Range No guessing required. The Byram meters feature a wide range voltage input. The meter may be used with any distribution voltage from 120 V to 480 V. The installer always has the meter with the correct voltage rating. The wide range feature detects and operates accurately on the voltage required. 3

Byram s Electric Meters Byram s meters are revenue grade electronic devices that measure the amount of electric energy consumed by a residence, business, or an electrically powered device. Byram s electric meters also measure demand for when energy savings during certain periods is desired. Additionally, these meters allow for time of day metering, meaning electric rates can be changed during a day in order to record usage during peak high-cost periods and off-peak, lower-cost, periods. Key Features Quick and easy to install Low ownership cost Fully programmable Reliable, revenue grade Preprogrammed at Byram Laboratories, Inc. Conforms to ANSI electrical standards UL Recognized safety Space saving footprint Pulse output capabilities Potential for future integration in smart metering mesh network Meter Limited Warranty Optional Feature Upgrades (TOU) Time-of-use (LP) Load profile (PQM) Power quality management (I-LP) Instrumentation profiling (ADV) Advanced metering (4 Quadrant) (A3R) Reactive Meter (Watt/Var) (A3K) Apparent Power Meter (Watt/VA) Selectable demand intervals Alternate communication options: - RS232 ANSI - RS485 ANSI - Ethernet Byram warrants that goods shall be delivered free of defects in material and workmanship. The warranty remedy period for goods is effective for a period of (5) five years following the date of shipment when installed in accordance with manufacturer s instructions by qualified personnel. Meter Kits Include Byram Single Phase Meters Revenue grade meter Calibrated current transformers Meter locking seal (applied after installation) Mounting template Meter manual Display cycle descriptions Terminal Butt Connectors Byram Polyphase Meter Revenue grade meter Calibrated current transformers Meter locking seal (applied after installation) Mounting template Meter manual Display cycle descriptions 4

Single Phase / Residential Specifications Voltage 1 phase, 2 wire service 1 phase, 3 wire service 1 phase, 3 wire service Current Frequency Temperature Humidity General performance characteristics Starting current Creep 0. 00 0 A (no current) Burden IEC standards compliance Additional standards 120 VAC ± 20% 120/208 VAC ± 20% 240 VAC ± 20% 200A Nominal 60 Hz ± 5% -40 F to +131 F (ambient) 0% to 100 % (non-condensing) 100mA No more than 1 pulse me asure d per quantity, conforming to ANSI C12.1 requirements Less than 1.5W IEC 62052-11, IEC 62052-21, IEC 62053-21 C12.19, C12.22, AS/NZS 4268, NMI M6 Byram Single Phase Meters Byram s meters are electronic electricity meters designed to meet residential metering requirements and provide remote communications. The meters are capable of measuring interval data, bidirectional energy, critical tier, and time-of-use (TOU) data. Byram s smart meters are available in most common residential wiring configurations. Non Demand Meter Kits Models Ordering CT Amperage Number Voltage Diagram Measurement* Electrical System B10-2120100 1C73 120 BL-3 100A 1 Phase, 2 Wire B10-2120200 1C7383 120 BL-3 200A 1 Phase, 2 Wire B10-3208100 1C7319 208/240 BL-3 100A 1 Phase, 3 Wire, Network B10-3208200 1C7320 208/240 BL-3 200A 1 Phase, 3 Wire, Network *Only 1 CT supplied for 2 wire meters. Other amperages available upon request Install Diagram Page 15 15 16 16 Demand Meter Kits Models Ordering CT Amperage Number Voltage Diagram Measurement* Electrical System B10-2120100D 1C7384 120 BL-3 100A 1 Phase, 2 Wire B10-2120200D 1C73 120 BL-3 200A 1 Phase, 2 Wire B10-3208100D 1C7074 208/240 BL-3 100A 1 Phase, 3 Wire, Network B10-3208200D 1C7323 208/240 BL-3 200A 1 Phase, 3 Wire, Network *Only 1 CT supplied for 2 wire meters. Other amperages available upon request Install Diagram Page 15 15 16 16 5

Single Phase Meter Dimensions 5.2 2.8 8.6 8.8 9.0 ENCLOSURE DIMENSIONS 5.2 in X 8.6 in X 2.8 in Split Core CT Dimensions Features Secured latch & keying hole for locking/service tag Swing open for ease of installation Rigid housing case with UL rated durable plastic Indoor rated 6ft twisted pair leads 22 AWG black/white leads BL 3 Series Applications Energy and sub-metering products Electrical load monitoring Network equipment Instruments and sensors Control systems Go GREEN initiatives 2.00.70.75.57 2.13.93 6

The Byram Polyphase Meter The Byram meter is a very accurate revenue meter (0.2 accuracy Class). The meter provides advanced four quadrant revenue functions, transformer and line loss compensation, and increased data profiling without adding hardware option boards. The main circuit board has a nonvolatile memory for storing profile, data logs, and self read data. If extensive profile recording is required, an extended memory option board can be easily added to increase total memory by 1 MB. When optional instrumentation profiling is enabled, the meter stores 2 separate sets of instrumentation data. Each data set has an independent interval length and up to 16 channels. With instrumentation profiling, each meter becomes a powerful data collection tool to monitor data and diagnose problems without installing expensive temporary monitoring equipment. Power Quality Management Power quality management (PQM) provides continuous service condition monitoring 24 hours a day. PQM looks for exceptions to user-defined thresholds for items such as voltage, current, and total harmonic distortion. Each of the 12 PQM tests can be configured to control relay activation, LCD warning, date/time stamp log entry, and even an automatic telephone call to report the condition. Specifications The Byram Electric Meter 3-Phase, 3-Wire/ Commercial & Industrial Maximum voltage Continuous 528 VAC Operating Range 120V - 480V Surge voltage withstand ANSI C37.90.1 oscillatory 2.5kV, 2500 strikes Fast transient 5kV, 2500 strikes ANSI C62.41 6kV at 1.2/50 µs, 10 strikes IEC 61000-4-4 4kV, 2.5 khz repetitive burst for 1 minute ANSI C12.16 2.5 kv, 60 Hz for 1 minute Temperature -40 F to 122 F (Inside meter cover) Humidity 0 to 100% RH (Non condensing) Enclosure Rugged IP-66 outdoor-rated Material UV Resistant Polycarbonate UL Type 4X/6P Listed Width x Height x Depth 8.5 in x 7.7 in x 5.5 in Weight 2.85 lbs. ANSI Standards C12.1; C12.10; C13.; C12.19; C12.20; C12.21 7

Non Demand Meter Kits Models Ordering CT Amperage Voltage Number Diagram Measurement* B20-120100 1C7302 120V BL-3 100A B20-120200 1C7303 120V BL-3 200A B20-120400 1C7304 120V BL-4 400A B20-120800 1C7305 120V BL-5 800A B20-1201600 1C7306 120V BL-6 1600A B20-240100 1C7307 240V BL-3 100A B20-240200 1C7308 240V BL-3 200A B20-240400 1C7309 240V BL-4 400A B20-240800 1C7310 240V BL-5 800A B20-2401600 1C7311 240V BL-6 1600A B20-480100 1C7312 480V BL-3 100A B20-480200 1C7313 480V BL-3 200A B20-480400 1C7314 480V BL-4 400A B20-480800 1C7315 480V BL-5 800A B20-4801600 1C7316 480V BL-6 1600A Demand Meter Kits Models Ordering CT Amperage Number Voltage Diagram Measurement* B20-120100D 1C7287 120V BL-3 100A B20-120200D 1C7288 120V BL-3 200A B20-120400D 1C7289 120V BL-4 400A B20-120800D 1C7290 120V BL-5 800A B20-1201600D 1C7291 120V BL-6 1600A B20-240100D 1C7292 240V BL-3 100A B20-240200D 1C7293 240V BL-3 200A B20-240400D 1C7294 240V BL-4 400A B20-240800D 1C7295 240V BL-5 800A B20-2401600D 1C7296 240V BL-6 1600A B20-480100D 1C7297 480V BL-3 100A B20-480200D 1C7298 480V BL-3 200A B20-480400D 1C7299 480V BL-4 400A B20-480800D 1C7300 480V BL-5 800A B20-4801600D 1C7301 480V BL-6 1600A Meter Kits Include Revenue grade meter Calibrated current transformer Meter locking seal (applied after installation) Electrical System *Other ratios available upon request Electrical System *Other ratios available upon request Mounting template Meter manual Display cycle descriptions Install Diagram Page Install Diagram Page Condo Multi-Family Student Housing Hospital Restaurant Theater Duplex Municipal Franchise/Chain Residential High Rise Apartments 8

The Byram Polyphase Meter 3-Phase, 4-Wire/ Commercial & Industrial The Byram meter is a very accurate revenue meter (0.2 accuracy Class). The meter provides advanced four quadrant revenue functions, transformer and line loss compensation, and increased data profiling without adding hardware option boards. The main circuit board has a nonvolatile memory for storing profile, data logs, and self read data. If extensive profile recording is required, an extended memory option board can be easily added to increase total memory by 1 MB. When optional instrumentation profiling is enabled, the meter stores 2 separate sets of instrumentation data. Each data set has an independent interval length and up to 16 channels. With instrumentation profiling, each meter becomes a powerful data collection tool to monitor data and diagnose problems without installing expensive temporary monitoring equipment. Power Quality Management Power quality management (PQM) provides continuous service condition monitoring 24 hours a day. PQM looks for exceptions to user-defined thresholds for items such as voltage, current, and total harmonic distortion. Each of the 12 PQM tests can be configured to control relay activation, LCD warning, date/time stamp log entry, and even an automatic telephone call to report the condition. Specifications The Byram Electric Meter Maximum voltage Continuous 528 VAC Operating Range 120V - 480V Surge voltage withstand ANSI C37.90.1 oscillatory 2.5kV, 2500 strikes Fast transient 5kV, 2500 strikes ANSI C62.41 6kV at 1.2/50 µs, 10 strikes IEC 61000-4-4 4kV, 2.5 khz repetitive burst for 1 minute ANSI C12.16 2.5 kv, 60 Hz for 1 minute Temperature -40 F to 122 F (Inside meter cover) Humidity 0 to 100% RH (Non condensing) Enclosure Rugged IP-66 outdoor-rated Material UV Resistant Polycarbonate UL Type 4X/6P Listed Width x Height x Depth 8.5 in x 7.7 in x 5.5 in Weight 2.85 lbs. ANSI Standards C12.1; C12.10; C13.; C12.19; C12.20; C12.21 9

Non Demand Meter Kits Models Ordering CT Amperage Voltage Number Diagram Measurement* B20-208100 1C7234 208V BL-3 100A B20-208200 1C7235 208V BL-3 200A B20-208400 1C7321 208V BL-4 400A B20-208800 1C7322 208V BL-5 800A B20-2081600 1C7281 208V BL-6 1600A B20-277100 1C7283 277V BL-3 100A B20-277200 1C7282 277V BL-3 200A B20-277400 1C7284 277V BL-4 400A B20-277800 1C7285 277V BL-5 800A B20-2771600 1C7286 277V BL-6 1600A Electrical System Install Diagram Page *Other ratios available upon request Demand Meter Kits Models Ordering CT Amperage Number Voltage Diagram Measurement* B20-208100D 1C6629 208V BL-3 100A B20-208200D 1C7145 208V BL-3 200A B20-208400D 1C7146 208V BL-4 400A B20-208800D 1C7147 208V BL-5 800A B20-2081600D 1C7148 208V BL-6 1600A B20-277100D 1C7149 277V BL-3 100A B20-277200D 1C7150 277V BL-3 200A B20-277400D 1C7151 277V BL-4 400A B20-277800D 1C7152 277V BL-5 800A B20-2771600D 1C7153 277V BL-6 1600A Meter Kits Include Revenue grade meter Calibrated current transformer Meter locking seal (applied after installation) Electrical System *Other ratios available upon request Mounting template Meter manual Display cycle descriptions Install Diagram Page Condo Multi-Family Student Housing Hospital Restaurant Theater Duplex Municipal Franchise/Chain Residential High Rise Apartments 10

Polyphase Meter Dimensions.82 6.54 1.12 8.48 6.54 6.75 7.69 3.98 TOP A TOP B 6.01 @ TOP OF BACKPANEL 6.01 @ TOP OF BACKPANEL 5.47 1.125 4.34 4.82 SIDE A SIDE B ENCLOSURE DIMENSIONS 8.5 in X 7.7 in X 5.5 in 11

Split Core CT Dimensions Features Secured latch & keying hole for locking/service tag Swing open for ease of installation Rigid housing case with UL rated durable plastic Indoor rated 6ft twisted pair leads Black/white leads BL-2-22AWG BL-3-22AWG BL-4 - AWG BL-5-16AWG BL-6-16AWG Applications Energy and sub-metering products Electrical load monitoring Network equipment Instruments and sensors Control systems Go GREEN initiatives BL 2 Series Dimensions [63.50mm] 2.50 [25.40mm] 1.00 [22.86mm].90 [19.30mm].76 Leads [70.87mm] 2.79 [35.56mm] 1.40 Black White Outside Dimensions 2.79 in X 2.50 in Inside Dimensions 1.40 in X 1.00 in 12

BL 3 Series Dimensions 2.00.70.75.57 Leads 2.13.93 Red White Black White Outside Dimensions 2.13 in X 2.00 in Inside Dimensions.93 in X.75 in BL 4 Series Dimensions Leads Black 3.82 1.70 White 1.14 1.30 3.60 Outside Dimensions 3.82 in X 3.60 in Inside Dimensions 1.70 in X 1.30 in 13

Split Core CT Dimensions BL 5 Series Dimensions Leads 6. 3.50 Black White 1.24 2.00 4.37 Outside Dimensions 6. in X 4.37 in Inside Dimensions 3.50 in X 2.00 in BL 6 Series Dimensions Leads 8.19 5.50 Black White 1.24 2.00 4.37 Outside Dimensions 8.19 in X 4.37 in Inside Dimensions 5.50 in X 2.00 in 14

1 Phase, 2 Wire Installation Diagram Connection Wires Located Inside The Byram Meter Black White Black/White Pulse Output L1 N CT1 K Z 1. Neutral Bar 3. Terminal - Butt Connectors Load * N L1 Twisted pair 2. CT1 1. Mount Meter 2. Install Current Transformer 3. Connect Voltage and Neutral Wiring * Recommended fuses or circuit breaker per the National Electrical Code. Typical Fuses: 1A fuses (not included) 15

1 Phase, 3 Wire Installation Diagram Connection Wires Located Inside The Byram Meter Black White L2 Red Black & White Red & White Pulse Output L1 N CT1 CT2 KZ 1. Neutral Bar CT1 CT2 2. Terminal - Butt Connectors * * Twisted pairs 3. 1. Mount Meter 2. Install Current Transformers 3. Connect Voltage and Neutral Wiring * Recommended fuses or circuit breaker per the National Electrical Code. Typical Fuses: 1A fuses (not included) 16

Installation Diagram Terminal Block Located Inside The Byram Meter LINE VOLTAGE Voltage Black Red Blue L1 CURRENT TRANSFORMERS L1 Black/White Twisted Pair PULSE OUTPUT L2 L3 X1 X2 X1 X2 K Y Z L3 Black/White Twisted Pair BAS 1. Twisted pairs 2. L1 L3 * * * 3. 1. Mount Meter 2. Install Current Transformers 3. Connect Voltage Wiring BAS = Building Automation System * Recommended fuses or circuit breaker per the National Electrical Code. Typical Fuses: 1A fuses (not included)

Installation Diagram Terminal Block Located Inside The Byram Meter LINE VOLTAGE CURRENT TRANSFORMERS Voltage L1 L2 L3 Black/White Black/White Black/White PULSE OUTPUT Black Red Blue White Twisted Pair Twisted Pair Twisted Pair L1 L2 L3 N X1 X2 X1 X2 X1 X2 K Y Z BAS 1. Twisted pairs Neutral Bar L1 L2 L3 2. * * * 3. 1. Mount Meter 2. Install Current Transformers 3. Connect Voltage and Neutral Wiring BAS = Building Automation System * Recommended fuses or circuit breaker per the National Electrical Code. Typical Fuses: 1A fuses (not included)

Manufacturer Representatives