AVM-8880 USB Logging Anemometer

Similar documents
ET-961 Hot Wire Thermo-Anemometer User Manual

CFM/CMM Hot-Wire Thermoanemometer

LX-1309 Lux Meter Manual

TA 888 Hot Wire Anemometer

The Specification of Hot Wire Anemometer Manual PCE-423

User Manual. Heavy Duty Hot Wire CFM Thermo-Anemometer. Model

HOT WIRE ANEMOMETER. Model : 204HA

Manual Anemometer PCE-423

User Manual. Data Logging Anemometer. Model with NIST-Traceable Calibration THE STANDARD IN PRECISION MEASUREMENT

Heavy Duty Hot Wire CFM Thermo-Anemometer

User Manual. Hand-held Laser Distance Meter

HDT-318 Thermo-Hygrometer with Data Logger. (Air Humidity/Temperature) Instruction Manual

User's Guide. Hot Wire Thermo-Anemometer. Model

Mini Environmental Quality Meter

User's Manual. VA893 Thermo Anemometer

User's Guide. Cup Thermo-Anemometer. Model AN400

User Manual. Dual-Input Data Logging Thermometers. with NIST-Traceable Calibration. Thermocouple Meter, Type J/K/T Input Model

Anemometer SD Card Datalogger. Instruction Manual

Digital Air Velocity Meter DC580. The Value Leader TM

User Manual. Data Logging Light Meter. Model with NIST-Traceable Calibration THE STANDARD IN PRECISION MEASUREMENT

User's Guide. Heavy Duty Vane Thermo-Anemometer. Model

Mini Environmental Quality Meter

User Manual. Thermocouple Thermometer with Dual Type K/J Inputs and Data Logging. Model with NIST-Traceable Calibration

ST Model. Instruction Manual. Multi-Function Environment Meter. reedinstruments. www. com

RS Stock No Instruction Manual RS Input Data Logging Thermometer

1. Introduction 2. Specifications 3. Symbol Definition and Button Location 4. Operation Instructions 5. Temperature Measurement 6.

Mini Environmental Quality Meter

DIGITAL ANEMOMETER Model : AM-4203

4 in 1 Anemometer, Humidity Light Meter, Thermometer

OPERATION MANUAL. auto range + type K Temp. optional Humidity, Light, Anemometer SOUND LEVEL METER Model : SL-4112

User's Guide. Hot Wire Thermo-Anemometer Model Introduction

Anemometer, Hygrometer Light Meter, Thermometer

Professional Thermocouple Thermometer with Four Type K Inputs, Data Logging, and Optional Infrared Wand

Datalogging Hot Wire CFM Anemometer

User's Guide. Hot Wire Thermo-Anemometer Model

User Manual. Thermohygrometer. Model with NIST-Traceable Calibration THE STANDARD IN PRECISION MEASUREMENT

Model LM-81LX. Instruction Manual. Light Meter. reedinstruments. REED Instruments

RS Stock No Instruction Manual RS Input Data Logging Thermometer

User's Guide. Heavy Duty Vane Thermo-Anemometer. Model

9 in 1 Anemometer, Humidity/Temp. meter, Light meter Pt 1000 Temp. ( optional ) Sport/Weather meter ENVIRONMENT METER Model : SP-8001

Using the Hotwire Anemometer

User's Guide. Vane Thermo-Anemometer Datalogger. Model Introduction

Contents. 1. Safety information 1 2. Description 2 3. Specifications 6 4. Operating instruction 8 5. Accessories 12

USER GUIDE. Dual Input True RMS AC Voltage/Current Datalogger. Model DL160

Heavy Duty Mini Vane CFM Thermo Anemometer

USER`S MANUAL Professional measuring instrument 4 in 1 ATE-9508

11 in 1 Environmental Meter

Temperature & Humidity Datalogger

ANEMOMETER OPERATION MANUAL. metal vane + air flow. Model : AM-4206M


VANE ANEMOMETER HUMIDITY/TEMP.

True RMS AC Voltage/Current Datalogger

RA3211 PON optical power meter

OPERATION MANUAL. Model : AM Wind speed measurement, pocket type, IP-65 CUP ANEMOMETER

Model 6812 VOLUME FLOW ANEMOMETER. User Manual. Kanomax USA, Inc. 219 Route 206 PO Box 372. Andover, NJ USA. (800) Fax: (973)

Model 6812 VOLUME FLOW ANEMOMETER. User Manual. 219 Route 206 Phone: PO Box 372 Fax: (973)

Large Vane CFM/CMM Thermo-Anemometer

DataNet Installation Guide + Quick Start Guide Updated: August 2008

Large Vane CFM/CMM Anemometer / Psychrometer

Therma-Stor LLC Model LM in-1 Pocket Thermo-Anemometer, Hygrometer, Thermometer & Illuminometer. Instruction Manual.

User Manual. Single-Input Thermometers. with NIST-Traceable Calibration. Thermocouple Meter, Type J/K/T Input Model

Supplied with. Calibration certificate. Anemometer VT 200

USB COMMUNICATIONS INTERFACE LOOP LINK Contents. Side 1. Page 15. Page 29. Seite 43

Hygro Thermo-Anemometer Model

Air velocity, Air flow, Type K/J thermometer Real time data logger, Data logger no., RS232 ANEMOMETER. Model : DAF2005MDL

Digital Anemometer Operation Manual

Model ST-618. Instruction Manual. Digital Thermo-Anemometer. Digital Measurement Metrology, Inc PRECISION IS OUR VISION

VANE ANEMOMETER BAROMETER HUMIDITY/TEMP. Model : ABH-4225

Model R3001. Instruction Manual. Anemometer/Manometer. reedinstruments. www. com

Mini Environmental Quality Meter

Thermo-Anemometer Data Logger Model 1227

UNIVERSAL SOFTWARE. Universal Software. Data Sheet

DTM-321 REL HOLD T2 K-TYPE TEMP: 20 C 60 C 140 F C F HUMIDITY: %RH POWER-UP OPTIONS

Model 6813 THERMO-ANEMOMETER. User Manual. Kanomax USA, Inc. 219 Route 206 PO Box 372. Andover, NJ USA. (800) Fax: (973)

Model 6815 HYGRO-THERMOMETER ANEMOMETER. User Manual. Kanomax USA, Inc. 219 Route 206 PO Box 372. Andover, NJ USA

PUR 800 Operational manual

Manual Light Meter PCE -174

DATA ACQUISITION Hints and Tips

Torque Meter. Instruction Manual

User Manual. Single-Input Thermometers. with NIST-Traceable Calibration. Thermocouple Meter, Type J/K/T Input Model

ANEMOMETER OPERATION MANUAL. Model : AM-4207SD. SD card real time datalogger + Type K/J thermometer

Auto-timer Datalogging Temperature / Humidity Meter

Model LM-81LX. Instruction Manual. Illuminometer. reedinstruments. www. com

User's Guide. Mini Microscope. Model MC108

Heavy Duty Datalogger Module

SensorWATCH Basic RH - Wireless Setup Users Help Guide Part Number: A Revision: 1.1.0

USER MANUAL. Heavy Duty Manifold Pressure Gauge. Model HD780. Additional User Manual Translations available at

HH-521BT 4-Channel Thermocouple Data Logger (with Bluetooth) (Types K, J, T, N, E, R, S) Instruction Manual

Hygro-Thermometer / Datalogger

OPERATING MANUAL DATA LOGGING LIGHT METERS LXP-2, LXP-10B, LXP-10A

Model Instruction Manual. Digital Pocket Psychrometer. reedinstruments. www. com

Installation of Hot Disk v 7.3 and later on a PC with Windows 7, 8 or 10

1366 INSTRUCTION MANUAL

SEIKA. Braille Display. User s Manual V3 Pro Version 1.0


Handheld Odor Meter OMX-ADM. Operation Manual. Ver

DICKSON FH320/325 & FT300/325 DICKSON. Temperature/Humidity Recorder. Specifications. Applications & Product. Product. Contents: Getting Started

A803 INSTRUCTION MANUAL

C F MAX MIN TEMP:-20 C~ 60 C -4 F~140 F HUMIDITY: 0 ~ 100RRH HOLD TIMER T2 T1 RS-232 DC9V. h:m:m:s HUMIDITY TEMPERATURE METER POWER - UP OPTIONS

Data Logger / K,J,E,T, Type THERMOMETER SE-378

Transcription:

AVM-8880 USB Logging Anemometer Introduction This digital USB logging Anemometer is a precision instrument. It measures airflow levels and has the facilities to record and store measured valves when plugged into a computer. When not in use, the instrument should be kept in the carrying case provided, to protect it from damage. Features Records maximum and minimum with recall Large LCD with dual display showing velocity and temperature Data hold Measures air velocity in five different units Selectable units temperature Accessories included: Carrying Case, Software, USB Connection Cable, Hotwire Probe, AC/DC Adapter and 9V Battery. Applications This item can be used for environmental testing, air conveyors, flow hoods, clean rooms, air velocity, fans, motors, blowers, furnace, and spray booths. Specifications Measures in m/s (0.1 ~ 25.0), km/h (0.3 ~ 90.0), ft/min (20 ~ 4925), MPH (0.2 ~ 55.8) & knots (0.2 ~ 48.5) Measures temperature in C/ F Sampling rate of approximately 0.8 seconds Accuracy: ±5% of reading + 0.1m/s Accuracy for temperature: ±1 C/±1.8 F Operating temperature and humidity: 0 C ~ 50 C (32 F ~ 122 F) and less than 80%RH Power source: 1 x 9V battery or AC/DC Adapter (supplied) Power current: DC 60 ~ 90mA 46.7mm x 60mm LCD display Dimensions: 210L x 75W x 50H (mm) Weight of unit: 280g Function Buttons 1. Power On/Off Button 2. Hold/Zero Button 3. Mean Button 4. Min/Max Memory Button 5. Flow/Temp Button 6. Units Button for Temperature 7. Units Button for Velocity 8. Setup/Backlight Button 9. Enter Button Operation Instructions Power On/Off and Back Light for Display To turn the meter on by pressing the yellow power button (No 1) on the bottom of the unit. The meter will count down from 8 before briefly showing dashes whilst the meter connects with the probe. Press the power button once to turn the meter off.

To illuminate the LCD display, press the button (No 8). Repeat to turn the light off. Entering and Changing Set-up Options To enter or exit set-up mode press the SETUP button (No 8) for 3 seconds. In set-up mode you can change the area unit, the flow area and auto power off mode. To select the option you wish to change, scroll through using the or button (No 6&7) and press Enter (No 9) to change it. Using the Unit buttons (No 6&7) select the unit for area, or the area of measuring, or disable or enable auto power off, depending on which option you have selected. Press Enter to save the changes and press set-up to exit. Selection of Velocity, Flow and Temperature Units To change the units for velocity press the button (No 7) to scroll through the five different options and release when the desired unit is shown on the LCD display. For temperature and flow use the button (No 6) and repeat the same procedure to select the correct units. Data Hold and Zero the Unit Data hold allows the current reading to be frozen on the display. Press HOLD/ZERO button (No 2) to activate. An indicator at the top of the display will show HOLD. Press HOLD/ZERO again to cancel data hold and the instrument will return to normal operation. Before using the unit it is recommended that the sensor cover is covering the sensor and the meter is zeroed. Press HOLD/ZERO (No 2) for 2 seconds and four OOOO will show across the screen where the velocity reading is shown. This indicates that zero setting has been completed and the unit is ready for use. Minimum and Maximum Values This function is activated by pressing MAX/MIN (No 4) and will display the minimum and maximum values since the instrument was switched on. The first value is the maximum measured value with a MAX indicator shown at the bottom of the display. Press MAX/MIN again to display the minimum measured value with MIN indicator shown at the bottom of the LCD screen. Hold the MAX/MIN button for 2 seconds to exit MAX/MIN mode. Multi-point Mean Calculation To enter multi-point mean calculation press MEAN button (No 3) once and Mean will appear at the bottom of the screen. The upper line of the display will show stored readings and the lower line will show the current reading. To enter a reading for mean calculation press ENTER (No 9) when a reading is showing on the lower line of the display and the same reading will appear on the upper line of the display, this reading is now stored. Press ENTER to store your second reading and the second reading will appear on the upper line. Repeat this procedure until you have all the readings you require to calculate your mean value. To calculate the mean using your saved readings press MEAN button once, Mean will flash and your mean value will appear in the lower line of the display. Press MEAN again to return to normal view. If you wish to change units whilst in mean mode press Unit button (No 6). To change between temperature, flow, velocity and calculated volumetric flow rate press the FLOW/TEMP button (No 5). If you wish to change the units whilst in mean mode press the Unit button (No 6). Mean Calculation in Real Time To perform a mean calculation in real time hold down the MEAN button for 2 seconds and Mean will appear at the bottom of the display. The measuring time (mm:ss) is displayed in the top line, while the current reading is shown in the bottom line of the display. To start using this function press ENTER and the time will start counting up in seconds in the upper line of the display. Take your readings with the probe (you don t need to press any buttons until you have finished taking all your readings). When you are ready to calculate the mean press MEAN once. The time will stop, Mean will flash and your mean value will appear in the lower line of the display. If you wish to change units whilst in mean mode press Unit button (No 6).

To change between temperature, flow, velocity and calculated volumetric flow rate press the FLOW/TEMP button (No 5). If you wish to change the units whilst in mean mode press the Unit button (No 6). To return to normal view press MEAN. Hotwire Probe When using the hot wire probe, make sure that the probe is connected correctly into the top of the meter. On the top of the probe there is a silver sensor cover that you slide down when you are ready to take a reading. It is important, that the sensor cover is put back over the sensor when the probe is not in use to isolate the sensor from the environment and protect from damage. The probe provided is telescopic and can be extended to a convenient length for the required application. On the top of the sensor head there is an arrow to indicate which way the probe should be used when taking a measurement. It is important that you check this, if used in the wrong direction you will receive false readings. AC/DC Power Adapter This instrument is supplied with a regulated AC/DC adaptor. Do not use any other power adapter. Prior to connection slide off the back cover and remove the 9V battery. Connect the adaptor to the instrument and plug into a mains supply. Switch on the instrument as normal. Low Battery Indicator When the battery power falls below the required voltage a battery symbol will appear in the top left hand side of the display. To change the battery, slide the back cover off, disconnect the expired battery and replace. Maintenance and Calibration The instrument should be cleaned using a damp cloth to remove any dust or dirt. Do not store the instrument where the temperatures and humidity is excessively low or high. This should be taken into consideration especially when leaving the instrument in vehicles. Recalibration of this instrument will vary due to operating conditions and regulations. It is recommended that the meter be recalibrated at least once every 12 months. ATP offers a fully traceable calibration service to national standards. Please call our technical help line for current prices 01530 566804. Installing the Software Start Windows and insert the CD into the CD drive. Install Wizard should detect and install the software. If install wizard does not appear automatically go to START at the bottom of the desktop, then Run... Browse for DT-8880 DISK (D:) which is the name of the software. Click on DT-8880 DISK (D:) This will open up the files stored within the CD. Open the SETUP file and follow the instructions to install the software. Once this is complete you will see an icon appear on your desktop. The installation was successful, but before you can use the software you need to install the hardware drivers. Do not remove the CD. Installing the Hardware Drivers You will need to install the hardware drivers even if you already have installed the following ATP Data Logging Instruments as this meter comes with an updated version of the hardware. SL-8851 USB Logging Sound Level Meter SL-8852 USB Data Logging Sound Level Meter. LX-1309 USB Logging Lux Meter. LX-8809A USB Data Logging Lux Meter With the CD for the software still in the CD drive, turn the instrument on, and then connect the meter to the computer using the USB cable supplied.

A new window should appear automatically to install the hardware. Click install, to start installation. If you have any older version of the hardware already on your computer a notice box will appear asking you to remove them. Click yes, to continue. At the end of installation it will ask you to restart your computer, it is advised that you click yes. To un-install the driver (in the add or remove programs ) you will find a driver called Silicon Laboratories CP210x USB to UART Bridge (Driver Removal). Click on this to un-install. Using the Software Before connecting your computer turn on the instrument. Connect the instrument to the computer with the USB cable and open the software on the icon. The meter should connect automatically, showing the current readings in the meter image on the left hand side of the software and the software should start recording automatically on the Real-time Graph. If there is no connection the software will display OFF LINE in the instrument image. Check the connections are correct and plugged in. If the software still does not connect please look at 'Meter will not connect' in the Troubleshooting section.

General Recording with the Software The software will start recording as soon as the meter is connected and the software is opened. It will take a recording every couple of seconds and shows the results as a line graph. It is very easy to use allowing you to save results quick and easy. The results can be saved as a text file when you press SAVE AS at the top of the software window, or as a graph file that can only be opened through the software if you click on EXPORT. Trouble Shooting Meter will not connect First make sure when you are using the meter with the software that the USB cable is connected correctly and the battery in the meter is at the voltage required. If the hardware has been installed correctly you will be able to find out what COM port your meter will work with. To do this please follow the following instructions, but please note that these instructions were done using XP so if you are running a different version of windows it may be in a different place. Go to START on the tool bar at the bottom of your laptop. Go to Control Panel and find a computer icon with the word SYSTEM Double click on this icon and at the top of the System Properties window click on the HARDWARE tab, then Device Manager. This will open a window called Device Manager (this window can be seen below):

In the Device Manager list look for Ports (COM & LPT) and click on the + sign next to it to drop down a list of the hardware in your computer and next to each one there will be a COM or LPT number, this tells you which port or LPT it will work with. The name of the hardware you are looking for is Silicon Labs CP210x USB to UART Bridge (COM3) and next to this there will be a COM port number. For example on my computer this hardware will work when COM port 3 is selected on the software. If the hardware is not listed, this means that the hardware was not installed correctly. Uninstall the software and see if you can find the hardware listed in the add/remove programs (see below) If you can see it remove it so you can re-install everything again. UK Distributor ATP Instrumentation Ltd Tournament Way Ivanhoe Industrial Estate Ashby-De-La-Zouch Leicestershire LE65 2UU Tel: 01530 566800 Sales 01530 566804 Technical Fax: 01530 560373 www.atp-instrumentation.co.uk