Control Unit KEH-P / Force-1.DIN

Similar documents
Compensation Unit in X-, Y-, and Z-Direction AGE-S-XYZ

Control unit IndraDrive Commissioning Linear axis LDx with IndraDrive control unit

Gripper Change Adapter GWA

Operating and Installation Manual. EASYLAB Expansion modules Type EM-TRF for 230 V AC mains voltage

Installation manual plugs and connectors with screw connection (16/32 A)

MDM 011-Z1 Regen Resistor

Operating Instructions (Translation) 3. Safety Information. 1. Description. 2. Explosion Protection. Supply module Type 17-21BB-170x

Operating instructions. Speed monitor D / / 2014

PTB 01 ATEX 2064 U, IECEx PTB U. Example / Beispiel / Exemple: Type Operating Instructions

Line reactors SINAMICS. SINAMICS G120P Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation 4

Operating instructions. Standstill monitor A / / 2011

Line reactors SINAMICS. SINAMICS G130 Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation

Operating instructions. Switching amplifier DN0210 DN / / 2015

FUE 10 FUE-M/S 85A FUE-M/S 86A

Operating Instructions

QUICK START GUIDE. vau4/3. Frequency converter. operating instructions /12

Instruction Manual FB-606 FB-606 TF. Infrared Manual Remote Control. LJU Automatisierungstechnik GmbH

Operating Instructions

English. Operating manual. Universal transmitter UT125. Save for later reference. Companies / brands of GHM

Symmetra PX 160. Maintenance Bypass Enclosure. Installation 05/

Explosion-Protected Arc-Fault Protection ExAFCI Arc-Fault Circuit Interrupter

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

PTB 01 ATEX Example / Beispiel / Exemple. Type Operating Instructions

Masterswitch 25kW 230V-125A Automatic AC transfer switch

Technical Manual Room temperature controller

dv/dt filter compact plus Voltage Peak Limiter SINAMICS SINAMICS G120P dv/dt filter compact plus Voltage Peak Limiter Safety information 1 General 2

Installation Guide. QBox-V6. Standalone/Spare V6 SDI QBox. Standalone/Spare V6 SDI QBox. Part No. A

Polymer Electric. Operating Instructions. Control Unit SG-RST 153. Version 0.3

D-Pack 6 Classic ORDERCODE 50315

Electrical Parallel Gripper MEG 40 EC

B63/ NS MS. EtherNet/IP LINK

H Series PLC. ! : Indicates Compulsion. EH-150 Analog input module EH-AXH8M Instruction manual. Safety precautions DANGER CAUTION COMPULSION

Line filter SINAMICS. SINAMICS G130 Line filter. Safety information 1. General 2. Mechanical installation 3. Electrical installation 4

POCKET MULTIMETER Model No: MM18

Sliding shutter control Aluminium shutters

SKIVING MACHINE MAINTENANCE & INSTRUCTIONS MANUAL ASSK2. Allswage UK. Roebuck Street, West Bromwich, B70 6RB

USER MANUAL. Uninterruptible Power Supply Line-interactive VCL Series UPS VA. GE Critical Power

Polymer Electric. Operating Instructions. Control Unit SG-EFS 1X4 ZK2/1 8k2. Version 3

Electrical Parallel Gripper MEG 64 EC

Operation Manual. Capacitor Boxes adjustable 80 A / 125 A Track, 2,04 μf to 8 μf. Order Number

HST -M2 Switching element with locking mechanism (Translation of Original Manual)

PNOZ m ES RS232. Configurable Control System PNOZmulti. Operating Manual EN-01

013559en. Operating Instruction Booklet. EC-Screwdriver, for stationary use MINIMAT-EC

VFI RTG PDU 6-10K. Installation and user manual. Service and support: Call your local service representative

Operating manual. Diagnostic adapter VAS Operating manual Diagnostic adapter VAS Client documentation Revision: 00 Version: 05/2018

Phase comparator. User manual Document version: 02i00 Update:

SINAMICS. SINAMICS G120P dv/dt filter plus Voltage Peak Limiter. Safety information 1. General. Mechanical installation. Electrical installation 4

/ 2CKA001473B Technical Reference Manual Compact combination 1/1gang with T13 SSA-F-1.1.

IO-AO6X I/O Expansion Module 6 Isolated Analog Outputs

English. Operating Manual. Conductive point level switch MLR120. Retain for later reference. Companies / brands of GHM

OPERATING INSTRUCTIONS

The power behind competitiveness. Delta Infrasuite Power Management. Power Distribution Unit. User Manual.

Installation Instructions

EX-RC1 Remote I/O Adapter

IM /2016 REV01 LACI Production Monitoring Module

INSTRUCTION MANUAL TRIP CIRCUIT SUPERVISION RELAY GKAD1

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions

HST -S1 Switching element (Translation of Original Manual)

PRO-1250D CT MID DIN rail three phase four wire energy meter.

HST -TZ1 Guard-locking mechanism (Translation of Original Manual)

LXEM145 SERIES Lanx Australis single Phase KWh Meter 45Amp. User manual

USER MANUAL VIBRATION CONTROL RMA-POWER-BOX 107/230

Control unit SG-EFS 104/2W. EN Operating instructions. Innovative by tradition. Version SG-EFS 104/2W 24 V=/~

DIN Series MINIATURE CIRCUIT BREAKERS, RESIDUAL CURRENT CIRCUIT BREAKERS. Introducing the DIN Series High-quality, high-performance circuit breakers

Technical Manual Sensor / Switch actuator 1/1gang; 2/1gang; 2/2gang

User manual Technical parameters

Electronic Temperature Controller. Instruction Manual Version

Documentation. Mains filter AX2090-NF50. Version: Date:

SIMATIC. ET 200S distributed I/O Digital electronic module 4DO DC24V/0.5A ST (6ES7132-4BD02-0AA0) Preface. Properties 2. Diagnostics 3.

CS2 DMX Distribution Splitter

SUN2000P-375 W Smart PV Optimizer. User Manual. Issue 01. Date HUAWEI TECHNOLOGIES CO., LTD.

Obtaining Documentation and Submitting a Service Request, page xvii Safety Warnings, page xvii Safety Guidelines, page xx

SINAMICS G130. Terminal Module 150 (TM150) Operating Instructions 03/2013 SINAMICS

English. Operating manual. Limit switch GS125. Keep for future reference. Ventures / brands of GHM

ET 200S distributed I/O Digital electronic module 2DO AC V (6ES7132-4FB01-0AB0)

ET 200S distributed I/O system 4DO DC24V/2A ST digital electronic module (6ES7132-4BD32-0AA0)

SMS 3xxx/SMS 4xxx Safety switch with separate actuator

Operating instructions for AX5801. TwinSAFE drive option card for the AX5000 servo drive. Version: Date:

SIMATIC. ET 200S distributed I/O Digital electronic module 4DO DC24V/0.5 A ST (6ES7132-4BD01-0AA0) Preface. Properties 1. Diagnostics 2.

Display Panel BAT 100 LSN. en Operation Guide

Operating Manual Linear actuators MC55/24 MC55/230 MC55Y MC65/24 MC65/230 MC65Y. March 2011 / / EN

Manual Control Unit GFC 32

ATS-16 HV USER MANUAL. Automatic Transfer Switch 16A / 230Vac V090318

Control unit SG-EFS 104/4L. EN Operating instructions. Innovative by tradition. Version SG-EFS 104/4L AC/DC 24 V

Operation Manual Series W-500

Emerson Network Power provides customers with technical support. Users may contact the nearest Emerson local sales office or service center.

Installation- and Operating instructions for CU Port USB 2.0 Hub. Version: 1.3 Date:

External level devices for conductive point level switch

DANGER indicates that death or severe personal injury will result if proper precautions are not taken.

Keystone OM3 - EPI-2 Local Interface Module Installation and Maintenance Instructions

IRC 1100 Kalibrierstrahler / Calibration Source

LED Colour Flood 10W / 30W RGB LED floodlight. user manual

RTT2 ROOM TEMPERATURE SWITCH. Mounting and operating instructions

english S-5EC Potentiometer 5-step Operating Instructions Keep for reference! L-BAL-E265-GB 1608 Index 002

Model HM-535 Power Supply Installation and Service Instructions

SINAMICS G130. Voltage Sensing Module 10 (VSM10) Operating instructions 03/2011 SINAMICS

Technical Manual Sensor / Blind actuator, 1/1gang; 2/1gang

RТTH DUAL ROOM SWITCH

HST -M1 Switching element with locking mechanism (Translation of Original Manual)

Installation- and Operating instructions for CU Port USB 3.0 Hub. Version: 1.1 Date:

Transcription:

Translation of the Original Manual Control Unit KEH-P / Force-1.DIN Assembly and Operating Manual Superior Clamping and Gripping

Translation of the Original Manual Imprint: Copyright: This manual remains the copyrighted property of SCHUNK GmbH & Co. KG. It is solely supplied to our customers and operators of our products and forms part of the unit. This documentation may not be duplicated or made accessible to third parties, in particular competitive companies, without our prior permission. Technical changes: We reserve the right to make alterations for the purpose of technical improvement. Document number: Edition: 3.0 March 14, 2014 en SCHUNK GmbH & Co. KG, Lauffen/Neckar All rights reserved Dear customer, congratulation on choosing a SCHUNK product. By choosing SCHUNK, you have opted for the highest precision, top quality and best service. You are going to increase the process reliability of your production and achieve best machining results to the customer's complete satisfaction. SCHUNK products are inspiring. Our detailed assembly and operation manual will support you. Do you have further questions? You may contact us at any time even after purchase. Kindest Regards Yours SCHUNK GmbH & Co. KG Precision Workholding Systems Bahnhofstr. 106 134 D-74348 Lauffen/Neckar Tel. +49-7133-103-2503 Fax +49-7133-103-2189 automation@de.schunk.com www.schunk.com QM.UC.00002-R3.0 en

Table of contents Table of contents 1 About this manual... 4 1.1 Warnings... 4 1.1.1 Signal words... 4 1.1.2 Symbols... 4 2 Basic safety notes... 5 2.1 Intended use... 5 2.2 Environmental and operating conditions... 5 2.3 Product safety... 6 2.3.1 Protective equipment... 6 2.4 Personnel qualification... 6 2.5 Use of personal protective equipment... 7 2.6 Notes on particular risks... 7 3 Warranty... 8 4 Scope of delivery... 9 5 Technical Data... 10 5.1 Identification plate... 11 5.2 Dimensions... 12 6 Installation... 14 7 Initial commissioning and normal operation... 16 7.1 Initial commissioning... 16 7.2 Normal operation... 18 8 Troubleshooting... 20 9 Servicing and maintenance... 21 10 Storage... 22 11 Disposal... 23 12 Spare parts... 24 QM.UC.00002-R3.0 en 3

About this manual 1 1.1 About this manual This instruction is an integral part of the product and contains important information for a safe and proper installation, commissioning, operation, maintenance and helps for an easier trouble shooting. Before using the product, read and note the instruction, especially the chapter "Basic safety notes". Warnings The following signal words and symbols are used to highlight dangers. 1.1.1 Signal words DANGER WARNING CAUTION ATTENTION Dangers for persons. Non-compliance will inevitably cause irreversible injury or death. Dangers for persons. Non-compliance may cause irreversible injury or death. Dangers for persons. Non-observance may cause minor injuries. Information about avoiding material damage 1.1.2 Symbols Warning about a danger point Warning about dangerous electrical voltage Danger of magnetic field Danger of falling down workpieces General mandatory sign to prevent material damage 4 QM.UC.00002-R3.0 en

Basic safety notes 2 2.1 Basic safety notes Intended use This control unit has exclusively been designed for the operation of SCHUNK electro-permanent magnetic chucks, during the use of which it is essential, that the time between two ON/OFF cycles is not less than 3 minutes. This control unit has furthermore been designed for the installation inside the electrical cabinet of machine tools for the clamping and machining of workpieces and must operate in dry interiors with a relative air humidity of 5-15 % (max. 50% at 40, without condensation) and an ambient temperature of 5-40 C. The requirements of the applicable standards must be observed. The control unit may only be used in the context of its defined application parameters. For its intended use it is also essential to observe the technical data, the installation and operation notes as well as the maintenance intervals indicated in the present manual. DANGER Danger to short circuit The control unit must be installed inside the electrical cabinet of the machine tool and must always be protected against water and/or operating fluids from the machine and protected against metal chips. NOTE This control unit must not be placed in service until the machine tool, for which the controller is provided, satisfies the requirements of the Machinery Directive 2006/42/EC!! 2.2 Environmental and operating conditions Use the control unit only within its defined application parameters. "Technical data" ( 5, Page 10). Make sure that the environment is clean and the ambient temperature corresponds to the specifications. QM.UC.00002-R3.0 en 5

Basic safety notes 2.3 Product safety Dangers arise from the control unit, if e.g.: the control unit is not used in accordance with its intended purpose. the control unit has not been installed or maintained properly. the safety and installation notes have not been observed. Avoid any manner of working that may interfere with the function and operational safety of the control unit. Wear protective equipment. NOTE More information is contained in the relevant chapters. 2.3.1 Protective equipment Provide safety devices according to the EC Machinery Directive. 2.4 Personnel qualification Installation, first commissioning, maintenance, and repair of the control unit may be performed by trained qualified personnel, only. Any person called upon by the operator to work on the control unit must have read and understood the complete installation and operating manual especially the chapter "Basic safety notes" ( 2, Page 5). This applies particularly to personnel used only occasionally, such as maintenance personnel. 6 QM.UC.00002-R3.0 en

Basic safety notes DANGER Danger due to a magnetic field. This control unit always uses a magnetic system. The following groups of persons must not come into contact with it: Persons with pacemakers. Persons with metal or electronic prostheses. Persons with insulin pumps. Persons with muscular stimulation systems. Pregnant women. These persons should always keep a safe distance of at least 2m to the unit. 2.5 Use of personal protective equipment When using this product, observe the relevant industrial safety regulations and use the personal protective equipment (PPE) required! Use protective gloves, safety shoes and safety goggles. Observe safe distances. Minimal safety requirements for the use of equipment. 2.6 Notes on particular risks Remove the energy supplies before installation, modification, maintenance, or adjustment work. Ensure that no residual energy remains inside the system. Perform maintenance, modifications, and additions outside the danger zone. For all work, secure the control unit against accidental operation. QM.UC.00002-R3.0 en 7

Warranty 3 Warranty The warranty is valid for 12 months from the delivery date to the production facility under the following conditions: Intended use in 1-shift operation Observe the mandatory maintenance intervals. Observe the environmental and operating conditions. Parts touching the work piece and wearing parts are not part of the warranty. Procedure in the event of warranty The buyer agrees to send a written detailed report on newly discovered defects of the control unit to SCHUNK within 10 days after identification. 8 QM.UC.00002-R3.0 en

Scope of delivery 4 Scope of delivery Power adjustment LED Power adjustment push buttons MAG-LED MAG-push button LED KEY KEY push button DEMAG push button DEMAG-LED Fig. 1 The scope of delivery includes: Control unit Remote control (supplied as standard on the KEH-P series, on request for all other types) QM.UC.00002-R3.0 en 9

Technical Data 5 Technical Data Type Mains voltage Frequency Phases Rated current Rated short circuit current Breaking current of the fuse for the auxiliary cir-cuit IP rating FORCE-1.DIN / KEH.P / KEH.R 200 230 400 460 (VAC) 50Hz / 60Hz 2 + PE 32 A 6 ka 500 ma at 500 V AC IP20 regarding the control unit IP rating of the equipment in which it is installed: at customer s care Activation time >0.3s at cycle 3; < 8s at cycle 8 Activation change Weight Ambient temperature Ambient conditions 1 (de-) magnetization - max. every 3 min. ~ 2 kg 5-55 C Operation in dry interiors with a relative air humidity of approx. 5-15% Protect product from caustic vapors and excessive heat. 10 QM.UC.00002-R3.0 en

Technical Data 5.1 Identification plate The identification plate is placed on the control unit cover: Fig. 2 Information Id. No. Type Serial No. Work No. Voltage Frequency Channels Phases Current Lcm Year Weight Description Product code no. Model Product serial no. Product production no. Rated voltage (mains) Rated frequency (mains) Number of output channels Phases (mains) Rated current (mains) Rated short-circuit data Year of manufacture Weight The identification plate must never be removed! Please always have the serial no. at hand when contacting SCHUNK about technical matters. QM.UC.00002-R3.0 en 11

Technical Data 5.2 Dimensions KEH-P01 FORCE-1.DIN FORCE-1.DIN.1C KEH.R01 KEH.R02 KEH.R03 Fig. 3 Dimensions FORCE-1.DIN and KEH.R KEH-P02 FORCE-1.DIN.2 FORCE-1.DIN.2C Fig. 4 Dimensions FORCE-1.DIN.2 12 QM.UC.00002-R3.0 en

Technical Data KEH-P03-P08 FORCE-1.DIN.4 FORCE-1.DIN.3C FORCE-1.DIN.4C Fig. 5 Dimensions FORCE-1.DIN.3 and FORCE-1.DIN.4 FORCE-1.DIN.5, FORCE-1.DIN.6, FORCE-1.DIN.7 and FORCE-1.DIN.8 QM.UC.00002-R3.0 en 13

Installation 6 Installation PERICOLO Danger of electric shock! Touching live parts can cause death by electric shock. All the electrical connections must be carried out by an electrician who has all the relevant information for the job. Always observe laws, regulations and standards applicable at the site of installation and operation. 1 Check the packaging before accepting the control unit. 2 Open the packaging and take out the control unit. 3 Check the control unit for transport damage! 4 Compare the control unit with the specifications given in the order! DANGER Danger caused by short-circuit. Never start up the control unit if you have detected visual damage! Notify the freight carrier or SCHUNK GmbH & Co. KG immediately if you detect damage and/or missing components! (With all the relevant details.) 5 Compare the performance data on the identification plate of the control unit with the data of the electricity grid on site. 14 QM.UC.00002-R3.0 en

Installation 6 Position the control unit inside the electrical cabinet of the machine tool, making sure that the requirements of the IP protection class ( 5, Page 10) are met. We recommend installing the control unit and its power supply interrupting devices in an easily accessible place for maintenance and repairs, at a distance of approx. 0.6 to 1.7 m above the operating level. NOTICE Damage to the control unit due to a short-circuit. The control unit could be damaged by oil or water. The positioning of the control unit inside the machining area of the machine tool should be avoided during its installation and operation. Please install the control unit always and only on the inside of the machine tool s electrical cabinet. 7 Carry out all the electrical connections necessary for the use of the product according to the enclosed wiring diagram. The following devices must be installed upstream to the control unit in order to protect the unit, other devices and persons: 1 Protection device for overcurrent, i.e. fuse or circuit breakers. This device must comply with the specifications indicated on the manual of the magnetic chuck as well as with the relevant regulations and standards applicable in the country of installation and operation. These devices must be designed for amtype fuses or for type C circuit breakers. 2 Highly sensitive residual current device of 32mA, type A or B, in case of earth leakage. Automatic power off must be checked at the end of installation! NOTE Always connect the grounding conductor of the feeder cable, in order to avoid electric shocks and reduce interferences. The user is has to guarantee an efficient grounding, complying with the current regulations. QM.UC.00002-R3.0 en 15

Initial commissioning and normal operation 7 7.1 Initial commissioning and normal operation Initial commissioning After having installed the control unit ( 6, Page 14) as well as the electro-permanent magnetic chucks connected to the same, the following proper functioning must be checked: 1 Ensure that the magnetic chuck is not magnetized, by means of the steel tip of a screw driver. NOTE There may be slight remanent magnetization upon delivery, e.g. due to the handling of the chucks with lifting magnets. DANGER Danger of electric shock due to a faulty connection. Touching live parts can cause death by electric shock. The following step may only be taken after a correct installation and inspection of the protection devices ( 6, Page 14). 2 Apply voltage to the control unit. 3 Place the workpiece onto the magnetic chuck. WARNING Danger due to suspended loads. If this work requires the use of lifting equipment, cranes etc., please keep the respective safe distances! 4 Carry out a magnetization test. REMARK For a proper connection of the external control signals, please refer to the specific wiring diagram the control unit is supplied with. 5 Make sure that the workpiece remains clamped onto the magnetic chuck. 16 QM.UC.00002-R3.0 en

Initial commissioning and normal operation CAUTION Risk of injury due to workpieces coming undone due to a faulty display of the magnetic system. Ensure that the workpiece is properly clamped on the magnetic chuck (for example with the steel tip of a screwdriver), by taking the suitable safety precautions! 6 Carry out a demagnetization cycle. REMARK For a proper connection of the external control signals, please refer to the specific wiring diagram the control unit is supplied with. 7 Make sure that the workpiece has been released from the magnetic chuck. 8 Remove the workpiece from the magnetic chuck. 9 Please contact SCHUNK if the expected results are not achieved even after having strictly followed the a.m. steps. PLEASE NOTE Please always have the serial no. at hand when contacting SCHUNK about technical matters! QM.UC.00002-R3.0 en 17

Initial commissioning and normal operation 7.2 Normal operation To guarantee a proper functioning of the control unit, please carry out the following steps: 1 Ensure that the magnetic chuck is not magnetized, by means of the steel tip of a screw driver. 2 Apply voltage to the control unit. 3 Place the workpiece onto the magnetic chuck. WARNING Danger due to suspended loads. If this work requires the use of lifting equipment, cranes etc., please keep the respective safe distances! 4 Carry out a magnetization cycle on the chuck. REMARK For a proper connection of the external control signals, please refer to the specific wiring diagram the control unit is supplied with. 5 Make sure that the workpiece remains clamped onto the magnetic chuck. CAUTION Risk of injury due to workpieces coming undone due to a faulty display of the magnetic clamping system. Ensure that the workpiece is properly clamped on the magnetic chuck (for example with the steel tip of a screwdriver), by taking the suitable safety precautions! 6 The workpiece is now ready to be machined. 7 Carry out the demagnetization of the chuck. REMARK For a proper connection of the external control signals, please refer to the specific wiring diagram the control unit is supplied with. 18 QM.UC.00002-R3.0 en

Initial commissioning and normal operation 8 Make sure that the workpiece has been released from the magnetic chuck. 9 Remove the workpiece from the magnetic chuck. 10 Please contact SCHUNK if the expected results are not achieved even after having strictly followed the a.m. steps. NOTICE Damage to the magnetic chuck due to overheating The control unit has been designed for cycle times (magnetization and demagnetization) of at least 3 minutes to avoid overheating of the magnetic chuck ( 5, Page 10). Non-observance of these instructions may cause irreversible damage to the magnetic chucks and render the warranty void! QM.UC.00002-R3.0 en 19

Troubleshooting 8 Troubleshooting Problem Possible cause Corrective action The workpiece shifts on the magnetic chuck because it is not properly clamped The residual current device disconnects the circuit The magnetization cycle has not been performed correctly. The magnetization power adjusted on the remote control is not sufficient. Current leaks out of the intended circuit. Check the electric connections between the control unit and the magnetic chuck. If the remote control with adjustable power is used, increase the power and repeat the magnetization cycle. Disconnect the discharge cable of the magnetic chuck and make sure there is no earth leakage After having turned on the power supply, the control unit remains switched off. The feeder cable is not correctly connected. Switch off the electrical cabinet and check the connection to the electricity grid The demagnetization cycle is not carried out correctly Interferences affect the regular functioning of the control unit. PLEASE NOTE Install a mains filter upstream to the control unit. Please always have the serial no. at hand when contacting SCHUNK about technical matters! 20 QM.UC.00002-R3.0 en

Servicing and maintenance 9 Servicing and maintenance Excellent and careful maintenance is a decisive factor for optimum safety, functioning and performance and a longer service life of the product. DANGER Maintenance work must always be performed by an electrician. The maintenance personnel must read this operating manual carefully. Work inside the control unit must be done by SCHUNK Service personnel only. This type of control unit has exclusively been designed to be installed inside the electrical cabinet of the machine tool and doesn t therefore require any specific maintenance. However, we recommend checking the conditions of the connection cables to the mains and to the magnetic chucks on a monthly basis. Furthermore, the proper operation of the residual current device upstream of the control unit has to be checked regularly, according to the manufacturer s recommended intervals and methods. Please follow the a.m. instructions and maintenance intervals so as to avoid repairs and resulting down-times, failures and inconvenience. Defective electrical and electromechanical components must always be replaced by SCHUNK Service personnel. If components are replaced by the operator, this automatically renders the warranty void. After maintenance and before reconnecting and restarting the control unit, all protection devices must be reinstalled. QM.UC.00002-R3.0 en 21

Storage 10 Storage When storing the control unit for a longer period of time (max. 8 months), observe the following instructions to ensure its functionality up to the time of installation: Ensure correct packaging! Recommendation: store the product in its original packaging. The control unit and the packaging should be inspected at regular intervals. Inspect packaging for outer damage and effects due to impacts or weather. Make sure that the ambient temperature and humidity inside the warehouse correspond to the specifications indicated in the present user s and maintenance manual. 22 QM.UC.00002-R3.0 en

Disposal 11 Disposal This product is made of plastic, electrical, and electronic components. If it is taken out of operation, it has to be disposed of in compliance with the applicable regulations. As soon as the end of the lifecycle has been reached, the control unit has to be decommissioned, i.e. put into a state in which it can no longer be used for its original intended use and in which it is still possible to recycle the raw materials contained. NOTE SCHUNK GmbH & Co. KG assumes no liability for material damage or personal injury that may result from reusing individual components of the control unit for purposes other than the original intended use! SCHUNK GmbH & Co. KG provides neither implicit nor explicit declarations about possible usability of recycled components after decommissioning the control unit. Procedure for final decommissioning and disposal of the control unit: CAUTION Risk of injury. Decommissioning, disassembly and disposal of the control unit must be performed by qualified persons using suitable tools. 1 Ensure that the machine tool has safely come to a halt. Disconnect all the electrical, hydraulic and pneumatic connections that could cause unexpected movements of the machine or its components. 2 Disconnect the product from all devices. Have the control unit disposed of by a company specialized in the disposal of electrical equipment. QM.UC.00002-R3.0 en 23

Spare parts 12 Spare parts Please contact the SCHUNK service department for any spare parts request. 24 QM.UC.00002-R3.0 en