Temperature. Power requirements. Weight. Dimensions

Similar documents
Installing the Tracer MP503 Input/Output Module Ordering number: ,

Hardware Installation. Tracer MP581 Programmable Controller CNT-SVN01C-EN

PowerLogic High Density Metering System 1-Meter Enclosure

ArmorPoint I/O Field Potential Distributor, Series A

PanelView Plus/VersaView CE Terminals and Display Modules

MicroTech II TM Remote I/O Panel Installation Manual

Avanti HP Series Centrifuges Preinstallation

GSM-X. Communication module. Quick installation guide. Full manual is available on Firmware version 1.02 gsm-x_sii_en 08/18

PDI Modular Compact Remote Power Panel

PXC Compact Unitary Equipment Controller (UEC)

Enclosed Power Supplies

PV Rapid Shutdown device

Installation Instructions

HUBBELL SPIKESHIELD Wired-In Branch Panels Surge Protective Device (SPD)

hp uninterruptible power system r12000 xr models installation instructions

See instructions to download and install the latest version of LinkBoxLON and the user's manual at

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

Installation Note for the Cisco ME 3800X and ME 3600X Switch Power Supply and Fan Modules

Series Amp Pad Mount Quick Connect Input and Output Power Panels

InView Marquee Message Display

ICS Entrance Management Sign Installation Guide. Version 1.0

INSTALLATION INSTRUCTIONS

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual

Digital ac/dc (24V) Input Module

Installation Instructions

TRC-190 User s Manual

Satellite INSTALLATION GUIDE

CompactBlock Guard I/O EtherNet/IP Safety Modules

MicroTech II Remote I/O Panel Installation Manual

Solar Combiner Enclosure

BCM2 Series Branch Circuit Monitors Quick Setup Guide

Junos WebApp Secure 5.0 Hardware Guide

Line reactors SINAMICS. SINAMICS G130 Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation

Installation Job Aid for Ethernet Routing Switch 3600 Series

Installation Instructions

Installation, Operation, and Service Manual SIEMENS HEALTHCARE INTEGRATED ELECTRICAL CABINET

Series Amp Quick Connect Input and Output Power Panels

Installation Notes TII Model 341 Protector

Installation. MGE Galaxy 3500 and Smart-UPS VT. Maintenance Bypass, Distribution and Transformer Cabinet

ORB TM 4-20 ma Input Box Installation & Operation Manual

QUICK SETUP GUIDE. BCM2 Series Branch Circuit Monitors. Safety Information. Equipment Maintenance and Service. Raritan DANGER!

Installation Instructions

*Approved by CSA for non-hazardous locations (Group Safety Publication IEC Third Edition).

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

ArmorPoint 24V dc Input Modules, Series A

INSTALLATION INSTRUCTIONS

EH-RIO IP67 Profibus-DP I/O modules

REDUNDANCY MODULE TSP-REM360 AND TSP-REM600

INSTRUCTION MANUAL RA 55 RACK ADAPTER RACK ADAPTER FOR MST SERIES POWER MODULES

ATS22D88S6U. ATS22D88S6U soft starter-ats22-control110v-power 208V(25hp)/230V(30hp)/460V(60hp)/575V(75hp) Product data sheet Characteristics.

TruPortal Dual Door Interface Module Quick Reference

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

iconverter 2-Module Power Chassis

Perle MCR200 Installation Guide

Installation and Operation Manual

PanelView 600 Terminals

Installation Instructions

Symmetra PX 160. Maintenance Bypass Enclosure. Installation 05/

300 WATT, PFC, OPEN FRAME POWER SUPPLIES TABLE 1. OUTPUT RATINGS AND SPECIFICATIONS, RMW 300W SERIES

User s Manual. ACS550-PD 3R Irrigation Packaged Drive Supplement to ACS550-U1 User s Manual

This Datasheet for the IC697CHS790. Rack, 9 Slots, Rear Mount.

MODEL SST3-MV INSTALLATION INSTRUCTIONS FOR FEDERAL MODEL SST3-MV SELECTABLE SIRENTONE-MULTI VOLT


Rhino Redundancy Module PSM24-REM360S. Operating Instructions

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

TraceTek Leak Detection Master Module Installation Instructions TOOLS REQUIRED STORAGE

CMSA-100 Manual. Cinema Media Server Automation

Installation RA5112-C-16A-C20. Basic Rack Power Distribution Unit

InnoMedia Business VoIP ATA Models

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

SECTION SWITCHBOARDS

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

Configurable Output Distribution. 120V / 208V / 240V 60Hz. User Manual English

SySTIUM TECHNOLOGIES. Assembly Guide. Model 133i

Installation and Operation Tracer. MP503 Input/Output Module CNT-SVX09A-E4

ATS22D62Q soft starter-ats22-control 220V-power 230V(15kW)/ V(30kW)

Output Voltage* (nom.)(adjustable)

Dell Storage Center. Getting Started Guide. SCv2000 and SCv2020 Storage System. Regulatory Model: E09J, E10J Regulatory Type: E09J001, E10J001

User s Manual. ACS550-PD Stock 3R Irrigation Packaged Drive Supplement to ACS550-U1 User s Manual

Replacing the Power Supply

Model Channel TTL I/O

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

Flat Panel Static Wall Mount MSP-SS (GSM-210)

TM7BDM16A expansion block - TM7 - IP67-16 DI/DO - 24V DC A - M12 connector

Power Supply Installation

ATS22D75S6 soft starter-ats22-control 220V-power 230V(18.5kW)/ V(37kW)/500V(45kW)

Output Voltage* (nom.)(adjustable)

TBX-1316 High-Voltage Attenuator Terminal Block

TU531, TU532 Terminal Unit

E-Series Site Preparation Guide

Hardened 10/100Base-TX IEEE802.3at PoE PSE Ethernet Extender

TN-5308 Quick Installation Guide

TM7BDI16B. Main. Enclosure material. Input/output number 16 Input/output number of splitter box

FLEX Ex Spring Clamp Terminal Base

TM3AI4 module TM3-4 analog inputs

Overview These instructions are presented as a guideline for installing and setting up the LX Series Breaker Control Panel.

HCS-3600 / 3602 / 3604 Laboratory Grade & High RFI Immunity Switching Mode Power Supply with Rotary Encoder Control

Free Energy Band RCC30U Room Temperature Controller for Four-pipe Fan Coil Unit

ATS22C11S6U soft starter-ats22-control110vpower208v(30hp)/230v(40hp)/460v(75hp)/575v(100h

ATS22C21S6U softstarter-ats22-control110vpower208v(60hp)/230v(75hp)/460v(150hp)/575v(200hp)

Transcription:

Installing the Tracer Summit BMTX Building Control Unit Ordering numbers: BMTX001AAB000, BMTX001AAB010, BMTX001AAB001, BMTX001AAB011, BMTX001BAB000, BMTX001BAB010, BMTX001BAB001, BMTX001BAB011, BMTX001DAB000 For more detailed installation instructions refer to the Tracer Summit Hardware and Software Installation guide (BMTX-SVN01C-EN). Note: BCU boards identified with assembly number #64002334 require BCU image 16.089 or higher for Version 16 sites or V17.033 and higher for Version 17 sites. The assembly number is located on the top left side of the BCU board. All other BMTX BCUs that are connected to the site must be upgraded to the new BCU image at the same time this board is installed. The new BCU images are available to download from the proprietary Trane intranet software downloads web site. Failure to follow this instruction will result in the BCU board not working. CAUTION Avoid Equipment Damage! Install and use the controllers as specified by the manufacturer. Failure to do so may result in equipment damage. Selecting a mounting location Make sure that the location meets the operating environment requirements and clearance requirements described in the following sections. (See Figure 1 on page 2 for enclosure dimensions and Figure 2 on page 3 for mounting clearances.) The controller must be installed indoors. Trane recommends locating the controller: Near the controlled equipment to reduce wiring Where service personnel have easy access Where it is easy to see the operator display Where public access is restricted to minimize the possibility of tampering or vandalism CAUTION Avoid Equipment Damage! Install the controller in a location that is out of direct sunlight. Failure to do so may cause the controller to overheat. Operating environment requirements Make sure that the operating environment conforms to the specifications listed in Table 1. Table 1. Specifications Temperature Humidity Power requirements Weight Dimensions From 32 F to 122 F (0 C to 50 C) 10 90% non-condensing 120 Vac or 230 Vac, 1 A maximum, 1 phase, 50 or 60 Hz Mounting surface must be able to support 60 lb (28 kg) 16 ½ in. 14 ¾ in. 5 ½ in. (418 mm 373 mm 140 mm) Altitude 6,500 ft (2,000 m) Installation Category 3 Pollution Degree 2 Verifying model number for local power requirements Before installing the controller, verify that you have the correct model for local power requirements (Table 2). The model number is on the shipping label and on the product label inside the enclosure. Table 2. BMTX BCU model numbers US (120 Vac) CE (230 Vac) Description BMTX001AAB000 BMTX001BAB000 BMTX BCU BMTX001AAB010 BMTX001BAB010 BMTX BCU with operator display BMTX001AAB001 BMTX001BAB001 BMTX BCU with modem BMTX001AAB011 BMTX001BAB011 BMTX BCU with modem and operator displady BMTX001DAB000 N/A BMTX BCU UL-864- UUKL Trane ABusiness of American Standard Companies www.trane.com 2007 American Standard All rights reserved. 3270 3383 E

Figure 1. Enclosure dimensions 3270 3383 E 2

Figure 2. Minimum mounting clearances 12 in. (30 cm) 24 in. (60 cm) 12 in. minimum clearance 36 in. (90 cm) 12 in. (30 cm) minimum clearance 50 in. (130 cm) recommended from floor Note: Six of the twelve knockouts are dual-sized knockouts for 1-inch (25 mm) and ¾-inch (19 mm) conduit. 3 3270 3383 E

Mounting the back of the enclosure The back of the enclosure is shipped with the termination board installed inside it. The enclosure door is shipped separately. If the door has already been attached to the enclosure back, remove it. To mount the back of the enclosure: 1. Using the enclosure back as a template, mark the location of the four mounting holes on the mounting surface. Figure 3. Enclosure mounting holes Mounting hole (four locations) 2. Set the enclosure aside and drill holes for the screws at the marked locations. Drill holes for #10 (5 mm) screws or #10 wall anchors. Use wall anchors if the mounting surface is dry wall or masonry. 3. Insert wall anchors if needed. 4. Secure the enclosure to the mounting surface with the enclosed #10 (5 mm) screws. Wiring high-voltage ac power IMPORTANT Make sure that you have the correct controller model for 120 Vac or 230 Vac (see Table 2 on page 1). To ensure proper operation of the controller, install the power supply circuit in accordance with the following guidelines: The controller must receive power from a dedicated power circuit. Failure to comply may cause control malfunctions. A disconnect switch for the dedicated power circuit must be near the controller, within easy reach of the operator, and marked as the disconnecting device for the controller. High-voltage power-wire conduits or wire bundles must not contain input/output wires. Failure to comply may cause the controller to malfunction due to electrical noise. High-voltage power wiring must comply with the National Electrical Code (NEC) and applicable local electrical codes. High-voltage wiring requires three-wire 120/230 Vac service (line, neutral, ground). Note: The transformer voltage utilization range is 98 132 Vac (120 Vac nominal) or 196 264 Vac (230 Vac nominal). The panel automatically detects whether the current is 50 or 60 cycle. To connect high-voltage power wires: WARNING Hazardous Voltage! Disconnect all electric power, including remote disconnects, before servicing. Follow proper lockout/tagout procedures to ensure the power cannot be inadvertently energized. Failure to disconnect power before servicing could result in death or serious injury. CAUTION Use Copper Conductors Only! Unit terminals are designed to accept copper conductors only. Other conductors may cause equipment damage. 1. Lock open the supply-power disconnect switch. 2. At the top-right corner of the enclosure, remove the knockout for ½-inch (13 mm) conduit. 3. Open or remove the enclosure door if it is already installed. 3270 3383 E 4

4. Inside of the enclosure at the top-right corner, remove the high-voltage area cover plate. 5. Feed the high-voltage power wire into the enclosure. 6. Connect the line wire to the L terminal as shown in Figure 4. Figure 4. AC wiring Ground screw L terminal N terminal Connecting the main circuit board The main circuit board is attached to a plastic frame. It is shipped separately. The board can be kept in the office and programmed while the back of the enclosure is mounted and the termination board, which is attached to the back of the enclosure, is wired. After programming has been completed, connect the circuit board to the termination board as shown in the following procedure. To connect the circuit board: 1. Verify that the 24 Vac power cable is not connected to the termination board. 2. Hold the circuit board frame at a 90 angle to the back of the enclosure, as shown in Figure 5. Figure 5. Connecting the circuit board ribbon cable 7. Connect the neutral wire to the N terminal. 8. Connect the green ground wire to the chassis ground screw. The ground wire should be continuous back to the circuit breaker panel. 9. Replace the cover plate. WARNING Hazardous Voltage! The cover plate must be in place when the controller is operating. Failure to replace the cover plate could result in death or serious injury. 10. On a label, record the location of the circuit breaker panel and the electrical circuit. Attach the label to the cover plate. Wiring binary inputs For binary input wiring, see Chapter 5, BCU binary inputs in the Tracer Summit Hardware and Software Installation guide (BMTX-SVN01A-EN). UCM wiring For UCM wiring, see Chapter 6, UCM communication link wiring and topology in the Tracer Summit Hardware and Software Installation guide (BMTX-SVN01A-EN). 3. Connect the circuit board s 60-pin cable to the termination board s 60-pin slot. The connector is keyed to the slot. If you have difficulty connecting it, make sure that the key is lined up with the slot. 4. Align the snaps on the circuit board frame with the mounting locks at opposite ends of the enclosure back, as shown in Figure 6 on page 6. 5. Using the tabs that are at both ends of the top frame, push the two frames together. You will hear a click when the frames connect. 5 3270 3383 E

Figure 6. Connecting the frames 6. For controllers with an operator display, connect the operator-display cable to the circuit board (see Figure 7). 7. Connect the 24 Vac power cable to the termination board. The seven-segment LED display should light up. 8. Connect the Ethernet cable to the Ethernet connector on the circuit board. 9. Connect the telephone cable to the modem connector on the circuit board. Installing the door To install the enclosure door: 1. Unpack the door and check for missing or damaged parts. Check to make sure that the magnetic latches and touch screen (if ordered) are installed. Check for any cracks in the plastic. 2. Hold the door at a 90 angle from the enclosure back as shown in Figure 8 on page 7. 3. Align the hinge pegs on the door with the hinge holes on the enclosure. 4. Gently lower the door until it rests securely in the hinge holes. 5. Verify that the door swings freely on the hinges and that the magnetic latches hold the door securely when it is closed. 6. For doors with an operator display, connect the operator-display cable to the operator-display connector on the door (see Figure 8 on page 7). Figure 7. Cable connector and LED display locations 24 Vac power connector Seven-segment LED display Modem card (optional) Modem, phone line connector Operator-display connector Ethernet connector 3270 3383 E 6

Figure 8. Aligning the door Operator-display connectors Note: The operator-display cable passes beneath the termination board on enclosures with factory-installed operator displays. 7 3270 3383 E

Tracer Summit BMTX Declaration of CE Conformity Manufacturer name: Manufacturer address: Trane 4833 White Bear Parkway St. Paul MN 55110, USA The manufacturer hereby declares that the product: Product name: Model numbers: Tracer Summit BMTX building control unit BMTX001BAB000, BMTX001BAB001, BMTX001BAB010, BMTX001BAB011 Conforms to the following standards or other normative documents: Electromagnetic emission: (by Council directive 89/336/EEC) Electromagnetic immunity: (by Council directive 89/336/EEC) EN61326-1 Radiated EN55022: Conducted EN55022: EN61326-1 EN61000-4-2 EN61000-4-3:1996 Amendment A1:1998 EN61000-4-4 EN61000-4-5 EN61000-4-6 EN61000-4-8 EN61000-4-11 1998 Class B limit 1998 Class B limit ±4.0 kv by contact ±8.0 kv by air 10.0 V/m 80.. 1000 MHz ±2.0 kv ac power lines ±1.0 kv signal lines ±2.0 kv 0.15.. 80 MHz 30 A/m 1/2 cycle When and Where Issued Electromagnetic Emission: 4/5/2004 Electromagnetic Immunity: 4/19/2004 Mark of compliance John Olson Design/Compliance Engineer European contact Societe Trane (Epinal, France) 1, rue des Ameriques, B.P. 6 F-88191 Golbey Cedex, France Phone: (33) 329.31.73.00 Fax: (33) 329.81.24.98 This document validates CE conformity of the Tracer Summit BMTX building control unit. 3270 3383 E 8