Device Type Manager DTM for TF12, TF212

Similar documents
Temperature Transmitter head mounted TF02/TF02-Ex, field mounted TF202/TF202-Ex

Driver TF(2)12(-EX)-PB

Supplementary - Information 3KDE150021R3901 Rev. D. Content. Driver 2600T(261xx)-HART. Pressure and Level Transmitter

TEPI11 P/I signal converter

/8 DIN Universal Process Indicator

Operating Guide MODBUS (RTU) Communications Option IM/L150 MOD_2. Level Indicator L150 and L160

User Guide IM/C250 MOD_3. Modbus (RTU) Communications Option C250 and V250

/8 DIN Motorized Valve Controller

Thermal Mass Flowmeter

Inform IT Single Pen Circular Chart Recorder

FieldIT Multi Barrier NMB204/NMB204-EX (MB 204/MB 204-Ex)

DS 96/48 PK. Digital indicator. Manual 42/33-90 EN Rev. 00 DIM

100mm Process Indicator Recorder

ControlIT Process controller

User Guide Supplement Modbus TM Serial Data Communications Option IM/C100 MOD_6. /8 DIN Process Indicators and Controllers C100, C150, C160 and V100

Wall-/Pipe Mounted Universal Process Indicator

ABB Instrumentation. Specification DataFile COMMANDER 100. the-easy-to use 1. /8 DIN controller with extensive application capabilities

CMC III Temperature/Humidity Sensor

TORRIX-HART. Technical Documentation. The magnetostrictive level sensor with HART Protocol. Edition: Version: 5 Article no.

Indicomp 4 Bargraph Indicator

Configuration-, Parameterization Instruction 45/68-10-EN. Contrac actuators

Videographic Recorders

CMC III Universal Sensor

LME620-AI/-AN (Contrac) Electrical Linear Actuator

HART UNIVERSAL TEMPERATURE TRANSMITTER

HOME VENTILATION WITH HEAT RECOVERY. Ventilation units M-WRG-S/Z-S M-WRG-S/Z-24 M-WRG-S/Z-EIB M-WRG-S/Z-KNX (-F, -FC)

Control unit SG-EFS 104/4L. EN Operating instructions. Innovative by tradition. Version SG-EFS 104/4L AC/DC 24 V

Documentation ZB8610. Fan cartridge for EtherCAT and Bus Terminals. Version: Date:

English. Operating manual. Universal transmitter UT125. Save for later reference. Companies / brands of GHM

Device Type Manager for Contrac. Graphical User Interface for digital Communication with Contrac Actuators SW Release Manual EN Rev.

HART UNIVERSAL TEMPERATURE TRANSMITTER

Addendum to the Manual

Operating Instructions

Digital Indicator DS 48/24 E

PROCESS AUTOMATION MANUAL. Temperature Trip Amplifier. KFD2-GU-(Ex)1 ISO9001

SITOP UPS1600 under STEP 7 V13. SITOP UPS1600 under STEP 7 V13. Introduction. Safety notes. Description. Assigning the IP address

PSR-PC50. SIL 3 coupling relay for safety-related switch on. Data sheet. 1 Description

Universal Process Controller

MANUAL VAA-2E2A-G12-SAJ/EA2L Original Instructions Version 1.0

Line Coupler, MDRC LK/S 2.1, GH Q R0001

Polymer Electric. Operating Instructions. Control Unit SG-EFS 1X4 ZK2/1 8k2. Version 3

Type ME43. Quickstart

INSTALLATION, OPERATION, CONFIGURATION AND MAINTENANCE MANUAL September/2016 VTT10-PH. HART TEMPERATURE TRANSMITTER panel model

SITOP UPS1600 under STEP 7 V5. SITOP UPS1600 under STEP 7 V5. Introduction. Safety notes. Description 3. Assigning the IP address

Type Operating Instructions - Software. Bedienungsanleitung - Software Manuel d utilisation - Logiciel

Diagnostic and verification software ScanMaster FZC500

Temperature Transmitter TF12, TF212

C160 Wall-/Pipe Mounted Universal Process Indicator

Analyze IT Analytical Instruments Two-Wire ph, ORP, plon Transmitters

Operating Instructions VEGAMET 381

ABB Instrumentation. Powerful Device Management A tool checks everything. Reference case study. Stadtwerke Kiel AG. Instrumentation Solutions

SEM310 SEM310X HART UNIVERSAL TEMPERATURE TRANSMITTER

HART adapters. Data Sheet. HART FSK/PC modem USB Ex(Haz.) and Non-Ex(Haz.) applications

S900 I/O DTM 6.x. System Version 6.0. Power and productivity for a better world TM

Tap Manager TM100. Operating Instructions

Primary Setup Tool (PST) SIMATIC NET. Industrial Ethernet / PROFINET Primary Setup Tool (PST) Preface. Description. Software installation 2

Documentation EM2042. Sixteen Channel Digital Output Module with D-Sub Connector. Version: Date:

Power Electronic Units for Field Installation EAN823, EBN853, EBN861 (Contrac)

General Information 1. Connection 2. User Interface 3 ATC5300. Menus 4. Automatic Transfer Controller. Remote Control Software Manual A5E

PROFIsafe SITRANS. Pressure transmitter SITRANS P, DS III PROFIsafe series. Product Information 7MF4*34 04/2008 A5E

5504 Thermocouple Analog Input Module

Siemens Automation Products

LineMaster 200. Continuous-line recorder. Parameter setting instructions 42/43-28 EN Rev. 03

Electronic Temperature Controller. Instruction Manual Version

MindSphere. Fleet Manager. Introduction to "Fleet Manager" 1. User interface for "Fleet Manager" 2. User rights in "Fleet Manager" 3.

PTB 01 ATEX 2064 U, IECEx PTB U. Example / Beispiel / Exemple: Type Operating Instructions

PROFIsafe modules V2 ipar 75x-66x/ WAGO Safety-Editor-75x Quickstart

INFORMATION. SM Series Videographic Recorders PC Emulator Quick Start Guide. 1 Emulation Tips. Manual IM/SM500F, IM/SM1000, IM/SM2000, IM/SM3000

Introduction. For more information. HART Protocol 7.0 Valid for software levels from 05.00

DALI Professional Controller-4. Control unit Operating instructions

Technical Documentation

PROCESS AUTOMATION MANUAL. Universal Temperature Converter KCD2-UT2-(Ex)1 ISO9001

IBIS-R+ Archiving. Control IT. Supplement to manual 42/ Z3 EN

PHOENIX CONTACT GmbH & Co. KG

DI 8x24VDC ST digital input module SIMATIC. ET 200SP DI 8x24VDC ST digital input module (6ES7131-6BF00-0BA0) Preface. Documentation guide

TZIDC, TZIDC-200 HART

Thermal Mass Flowmeter Sensyflow FMT200-D

TRACKER 220 SERIES. Digital Panel Indicators. A Complete Range of Universal Input Digital Panel Indicators for Temperature and Process Measurement

UNIVERSAL TEMPERATURE TRANSMITTER

Original operating instructions Safety relay with relay outputs G1501S / / 2016

SIMATIC NET. Industrial Ethernet / PROFINET Primary Setup Tool (PST) Preface. Functions 1. Software installation 2. Operation. Configuration Manual

Documentation KM2042. Sixteen channel digital output module with D-Sub Connector. Version: Date:

The Tracker 220 Series A Complete Range of Universal Input Digital Panel Indicators for Temperature and Process Measurement

SIMATIC. STEP 7 PLUS TIA Portal Teamcenter Gateway. Introduction to TIA Portal Teamcenter Gateway 1. System requirements 2

Electrical network protection Sepam series 20 Sepam series 40 Quick start

Electromagnetic Flowmeter ProcessMaster, HygienicMaster FEX300, FEX500

Operating Manual. English. Digital-Analog Converter DACON8-UMB.

Control unit SG-EFS 104/2W. EN Operating instructions. Innovative by tradition. Version SG-EFS 104/2W 24 V=/~

ET 200S distributed I/O system 4DO DC24V/2A ST digital electronic module (6ES7132-4BD32-0AA0)

Technical Documentation

Modbus. Instructions 42/ EN

MU110-6U. Analog output module 6 channel. User guide

Operating instructions. Standstill monitor A / / 2011

Operating manual. GTL - Configuration tool. Please keep the manual for future use.

PTB 01 ATEX Example / Beispiel / Exemple. Type Operating Instructions

Getting Started - Startdrive. Startdrive SINAMICS. Introduction 1. Connecting the drive unit to the PC. Creating a project 3

SMVector Additional I/O Module Installation and Operation Manual

Machine Automation Controller NJ-series. EtherCAT. Connection Guide. OMRON Corporation. Digital Sensor Communication Unit (E3NW-ECT) P563-E1-01

Medium-Voltage Drive SINAMICS SM150. Type 6SL3845. Tests carried out on drives This documentation pertains to SM150 wassergekühlt G20 F03 F72 F79 F76

Pressure switch RE B/ Type HEDE10.../1/ Operating instructions

Transcription:

Manual 46/11-50 EN Device Type Manager DTM for TF12, TF212 PROFIBUS PA Communication for temperature transmitters TF12, TF212 P R O F I PROCESS FIELD BUS B U S

Device Type Manager DTM for TF12, TF212 PROFIBUS PA Communication for temperature transmitters TF12, TF212 Manual Document No. 46/11-50 EN Date of issue: 11.2005 Manufacturer: ABB Automation Products GmbH Borsigstr. 2 63755 Alzenau Germany Tel: +49 551 905-534 Fax: +49 551 905-555 CCC-Support.deapr@de.abb.com Copyright 2005 by ABB Automation Products GmbH We reserve the right to technical amendments. This document is protected by copyright. Information in this document is intended only to assist the user in the safe and efficient operation of the equipment. Its contents are not to be reproduced in full or part without prior approval of the legal owner. The software described in this document is licensed and may only be used, copied or disclosed in accordance with the license conditions. 2 Device Type Manager DTM for TF12, TF212 46/11-50 EN

Contents........................................................................ Page Important information................................................................. 4 1 Installation..................................................................... 5 2 Operation...................................................................... 5 2.1 Display options for the user interface............................................ 5 2.1.1 Intended use and functionality................................................. 5 2.1.2 Status indication in the input fields.............................................. 5 2.1.3 Window header and status bar................................................ 5 2.2 Communication............................................................ 6 2.2.1 Establishing a connection to the device.......................................... 6 2.2.2 Reading information from the device............................................ 6 2.2.3 Writing information to the device............................................... 6 2.2.4 Resetting to the default settings................................................ 6 Warm start................................................................ 6 Reset (bus address)......................................................... 7 Reset (standard settings)..................................................... 7 2.3 Description of the DTM user interface............................................ 7 2.3.1 Structure of the temperature transducer TF12/TF212............................... 7 2.3.2 Overview (UV)............................................................. 8 2.3.3 Configuration (UV).......................................................... 9 2.3.4 Transducer block (UV)...................................................... 10 Sensor type.............................................................. 11 Source of comparative temperature............................................ 11 Base resistance (resistive thermometers)....................................... 12 Connection type (resistive thermometers)....................................... 12 User defined characteristic curve.............................................. 13 Offset................................................................... 15 2.3.5 Calculation function........................................................ 16 Units.................................................................... 16 2.3.6 Function block (UV)........................................................ 17 Display.................................................................. 17 Units.................................................................... 17 Zoom function (magnifying glass)............................................. 18 Additional parameters...................................................... 18 Simulation............................................................... 19 Alarms (thresholds)........................................................ 19 Diagnosis (UV)............................................................ 20 46/11-50 EN Device Type Manager DTM for TF12, TF212 3

Important information Symbols In order that you can make the best use of this document and to ensure safety during commissioning, operation and maintenance of the equipment, please note the following explanation of the symbols used. Explanation of the symbols used. Symbol Signal Word Definitions DANGER DANGER indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury. (High level of risk.) WARNING CAUTION NOTICE WARNING indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury. (Medium level of risk.) CAUTION indicates a potentially hazardous situation which, if not avoided, could result in minor or moderate injury. (Low level of risk.) NOTICE indicates a potentially harmful situation which, if not avoided, may result in damage of the product itself or of adjacent objects. (Damage to property) IMPORTANT IMPORTANT indicates useful hints or other special information which, if not observed, could lead to a decline in operating convenience or affect the functionality. (Does not indicate a dangerous or harmful situation.) As well as the instructions in this document, you must also follow the generally applicable accident prevention and safety regulations. If the information in this document is insufficient in any situation, please contact our service department, who will be happy to help you. Please read this document carefully before installation and commissioning. CE marking The product complies with the specifications in the EMC Directive 89/336/EEC and the Low-Voltage Directive 73/23/EEC. 4 Device Type Manager DTM for TF12, TF212 46/11-50 EN

1 Installation Installation The DTM TF12/TF212 is installed as part of the setup for DSV401 (SMART VISION). For information on setup and licensing of DSV401 (SMART VISION) please see the operating instructions for the DSV401 (SMART VISION), 42/63-11. 2 Operation 2.1 Display options for the user interface 2.1.1 Intended use and functionality DTM TF12/TF212 is an application with which the TF12/TF212 transducers, can be configured and diagnosed via an acyclical (DPV1) PROFIBUS link, from a controlling application. The user interface of the DTM TF12/TF212 offers the following functionality: Online / offline configuration of the TF12/TF212 temperature transducers Uploading parameters = reading parameters from the device Downloading parameters = writing stored parameters back to the device Online display of measurements and status information Online diagnosis with display of fault sources 2.1.2 Status indication in the input fields Fields with a yellow background show information read from a particular transducer, which can't be changed. Fields with a grey background (tab: Configuration (UV)) show a summary of the current device configuration, which can only be displayed here and not changed. Fields with a white background containing black lettering show configuration parameters which have just been read from a transducer. These parameters can be changed and written back to the transducer. Parameters which have been changed, or parameters stored offline, are displayed in blue and are underlined. This shows that the information displayed in DTM might be different from that stored in the transducer. After a successful download, the parameters will be displayed in black letters. 2.1.3 Window header and status bar The window header shows the type of transducer as well as its bus address and its TAG name. Bus address TAG name Transducer Fig. 2-1 Window header and status bar 46/11-50 EN Device Type Manager DTM for TF12, TF212 5

The bottom of the device window is a status bar. It shows the status of the communications connection to the device (connected / not connected), whether data uploaded from a device is being shown (data loaded / no data loaded) and the status of the device (OK / fault). Also, for certain procedures (e.g. when loading or storing the data to / from the transducer), a bar shows the progress made. Indication of the status Fig. 2-2 Status display 2.2 Communication 2.2.1 Establishing a connection to the device To be able to exchange information with the transducer, a connection must first be established between the DTM and the transducer. Establish a connection between DTM and the device via Device Connect. 2.2.2 Reading information from the device Information is read from the device to the DTM via Device Load from device. This command must always be manually executed if information is to be read from the transducer as the data is not read automatically when the DTM is opened. Acknowledge warnings with OK 2.2.3 Writing information to the device Any changes to the configuration are only valid when they are transmitted to the transducer. To transmit data, use Device Save to the device. Acknowledge warnings with OK 2.2.4 Resetting to the default settings Via the menu Device Defaults the following commands can be called up, with which the temperature transducer can be reset to its default settings: Warm start A warm start restarts the device as far as the PROFIBUS communication is concerned. WARNING During a warm start the device interrupts both the cyclical and the acyclical PROFIBUS communication. This means that, during the restart phase, error messages will be produced, reporting that contact has been lost with the transducer. You should thus ensure that no important or critical process is relying on having contact with the transducer before you do a warm start. 6 Device Type Manager DTM for TF12, TF212 46/11-50 EN

Reset (bus address) Reset sets the PROFIBUS address back to 126. The stored parameters will not be changed by that. WARNING The bus address will be changed to 126 immediately. The transducer will thus be removed from the cyclical and acyclical bus communication immediately after the Reset (bus address) command. You should thus ensure that no important or critical process is relying on having contact with the transducer before you do a reset (bus address). Reset (standard settings) Reset sets the parameters back to the factory default settings. The standard settings are: 2 Pt 100 3-wire, 0...100 C, etc. WARNING When resetting the parameters, the bus address is not changed. The transducer thus remains accessible via cyclical and acyclical bus communication. It is possible that error messages will be produced, reporting that the measurements are no longer reliable. You should thus ensure that no important or critical process is relying on having contact with the transducer before you do a reset (standard settings). 2.3 Description of the DTM user interface 2.3.1 Structure of the temperature transducer TF12/TF212 The TF12/TF212 temperature transducers are structured to correspond to the Profibus PA profile definition version 3.0 as specified by the PROFIBUS user organization (abbrev. PUO). For the transducer, the following block diagram thus results. This block diagram can be used to illustrate the workings of the DTM program user interface, which is closely modeled on this scheme. Offset Sensor 1; (T1) Secondary_Value_1 / SV 1 Function Block 2 FB2 Temperature 1 + Status Transducer Block TB PV=SV1: Secondary Value 1 PV=SV2: Secondary Value 2 PV=SV1 - SV2: Difference PV=SV2 - SV1: Difference PV=1/2 x (SV1+SV2): Average PV=1/2 x (SV1+SV2): Average / Redundance Primary_Value / PV Function Block 1 FB1 Calculated Temperature + Status Sensor 2; (T2) Secondary_Value_2 / SV2 Function Block 3 FB3 Temperature 2 + Status Offset Fig. 2-3 Structure of the temperature transducer TF12/TF212 The TF12/TF212 temperature transducer offers the option of connecting one or two sensors independently from one another. In the transducer block the input signal will be linearized corresponding to the selected type of sensor. The type of sensor connected is thus also set in the transducer block. In addition, up to 4 user-defined characteristic curves can be programmed. Arithmetic functions are then connected to the transducer block with which, to start off with, a configured offset for every measured sensor value can be separately produced. Afterwards, using these same sensor measurements, a third, calculated measurement value can be produced as a difference or as an average. After this, the measurement values are checked in the 3 function blocks to see whether the configured upper or lower process limits have been reached or if an alarm threshold has been reached, so as to transmit a corresponding status message. 46/11-50 EN Device Type Manager DTM for TF12, TF212 7

2.3.2 Overview (UV) Operation Normally the DTM display in the User View. This is shown by (UV) at the end of the tab title. As all relevant parameters can be changed with this setting, it should not be changed. The engineering view (expert level) is only for internal service purposes and is protected by a password. Fig. 2-4 Overview Device type Hardware version Software version Serial number Identity number (PUO) Certification Bus address TAG name of the device Installation date Notes Shows the type of the transducer (belonging to the bus address). Displays the internal hardware version. Displays the version of the software installed in the transducer. Displays the serial number of the device concerned. Displays the PROFIBUS identity number. Displays the PROFIBUS certification. Displays the bus address of the transducer. Option to enter a TAG name (name of measurement location). Option to enter the date. Option for additional notes. 8 Device Type Manager DTM for TF12, TF212 46/11-50 EN

2.3.3 Configuration (UV) By activating the tab Device TF12 View Configuration (UV) the following window will appear: Operation Fig. 2-5 Configuration In this window the current device configuration is shown as well as a selection as to whether the transducer is to be used with one or with two sensors. Channel 1: Channel 2: Linking the channels Difference signal Temperature sensor 1 (Status: always on) Temperature sensor 2 (Status: on or off) Status: always on Status: for 2 sensors always on, for 1 sensor always off The only selectable option in this window is the status of sensor 2. This can be switched on or off via the selection menu. This directly affects the options selectable on the tab Transducer block (UV). IMPORTANT If channel 2 is switched from off to on then, afterwards, a sensor must be selected in the transducer block for this change to become effective. If this is not the case, channel 2 will not be activated! IMPORTANT If a resistive thermometer with 4-wire connection is selected for channel 1, then sensor 2 will automatically be set to off and the selectable option for sensor 2 in the above window will be disabled. 46/11-50 EN Device Type Manager DTM for TF12, TF212 9

2.3.4 Transducer block (UV) By activating the tab Device TF12 View Transducer block (UV), the following window will appear: Operation Fig. 2-6 Transducer block (UV) The input signals for channel 1 and channel 2 as well as the calculation function are set in this window. The display and data entry options depend on the type of sensor configured. IMPORTANT If the status for channel 2 is set to off in the configuration window, the input options for sensor 2 in the above window will be disabled. IMPORTANT To activate the changes made, the data has to be saved to the device and then reloaded from the device! 10 Device Type Manager DTM for TF12, TF212 46/11-50 EN

Sensor type Setting the type of sensor determines the input signal for channel 1 and channel 2. The input options / connection options are as follows: Standard IEC 584-1 Input element Sensor Thermocouple type B Thermocouple type E Thermocouple type J Thermocouple type J Thermocouple type R Thermocouple type S Thermocouple type T Thermocouple type N W3, ASTME 998 Thermocouple type C Thermocouple type D DIN 43710 Thermocouple type L Thermocouple type U IEC 751 1) Pt 100 resistance thermometer Pt 1000 resistance thermometer Pt 100/Pt1000 resistance thermometer The selection is made via the corresponding list (sensor 1 or sensor 2). Measurement range 400...+1820 C (+752...+3308 F) 100...+1000 C ( 148...+1832 F) 100...+1200 C ( 148...+2192 F) 180...+1370 C ( 292...+2498 F) 50...+1760 C ( 58...+3200 F) 50...+1760 C ( 58...+3200 F) 200...+ 400 C ( 328...+ 752 F) 180...+1300 C ( 292...+2372 F) 0...+2300 C (+ 32...+4172 F) 0...+2300 C (+ 32...+4172 F) 100...+ 900 C ( 148...+1652 F) 200...+ 600 C ( 328...+1112 F) 200...+ 850 C ( 328...+1562 F) 200...+ 850 C ( 328...+1562 F) 100...+ 250 C ( 148...+ 482 F) DIN 43760 2) Ni 100 resistance thermometer 60...+ 250 C ( 76...+ 482 F) Resistance 2-, 3-, 4-wire 0...400 Ω/0...4000 Ω Voltage 15 mv...+115 mv User defined characteristic curve Voltage or resistance (2-, 3-, 4-wire) IMPORTANT In this window, the sensor limits (measurement range) will only be shown automatically (depending on the type of sensor as in the above table) if the data is transmitted to the transducer and then read back again. Source of comparative temperature The optional comparative temperature serves to reduce measurement errors and is included in each value measured. A selection list is used to set whether none at all, an internal or an external comparative temperature is used to be included in the calculation. Fig. 2-7 Source of comparative temperature No reference of for linear voltage Internal External No display / inclusion in the calculation of comparative temperature Display / use in the calculation of a current, constantly measured comparative temperature. Option to enter / include a constant comparative temperature in the calculation. 46/11-50 EN Device Type Manager DTM for TF12, TF212 11

Base resistance (resistive thermometers) IMPORTANT A base resistance can only be entered if a resistive thermometer has been selected. Connection type (resistive thermometers) In addition, a selection list is used here to choose the type of connection (2-, 3- or 4-wire connection). Fig. 2-8 Connection type (resistive thermometers) For 2-wire connections and option to enter the resistance of the wire in Ohms will appear (resistance of the wire between the sensor and the transducer). If a 4-wire connection is selected, the following warning message will appear: Fig. 2-9 Warning message for connection type If you confirm this with Yes, sensor 2 will automatically be set to off and the selection options for sensor 2 will be disabled in the Configuration window. 12 Device Type Manager DTM for TF12, TF212 46/11-50 EN

User defined characteristic curve The polynomial coefficients for the linearizing of voltage and resistance measurements are stored in each transducer. NOTICE The User defined characteristic curve setting is for customer specific programming of this linearization curve and should only be done by suitably trained specialists. When a user defined characteristic curve is selected, an additional tab appears User curve channel X (UV) per channel. When the User curve channel X (UV) tab is activated, the following window will appear: Fig. 2-10 User curve channel X (UV) Sensor signal Connection type Wiring resistance Description Resistance (0..400 Ohm) Resistance (0..400 Ohm) Voltage (-15...+115 mv) 2-wire 3-wire 4-wire Option to enter the resistance of the wiring in Ohms (only for 2-wire). Here you can enter a unique description of the user defined characteristic curve. A tool is included with the transducer, which calculates the necessary polynomial coefficients from the specified user specific table. To do this, the type of linearization in the selection list has to be changed from Polynomial to Table (see Fig. 2-11 Page 14). 46/11-50 EN Device Type Manager DTM for TF12, TF212 13

Fig. 2-11 Changing the type of linearization User defined characteristic curves are always saved as files with names ending *.crv. The Load... button can be used to load previously stored characteristic curves. Press the Save... button to store new or changed characteristic curves. Use the New button to enter new user defined characteristic curves. Press the Change... button to alter the currently displayed characteristic curve. A window will appear, which looks something like the following: Fig. 2-12 Changing the characteristic curve, linearizing table Click on the OK button to accept the characteristic curve entered. 14 Device Type Manager DTM for TF12, TF212 46/11-50 EN

Press the Cancel button to cancel the process; the data entered will not be accepted. Use the Delete... button to delete coordinate pairs which are no longer required. Press the New... button to insert a new pair of coordinates. Press the Change... button to change the pair of coordinates currently marked. A window will appear, which looks something like the following: You now have the option of entering coordinate pairs X and Y. The entries made are written to the table when you press the Accept button. Pushing the Cancel button finishes the data entry without accepting the input/ changes. Fig. 2-13 Entering coordinate pairs Offset Here, an offset can be entered for every sensor (channel), separately. Fig. 2-14 Offset 46/11-50 EN Device Type Manager DTM for TF12, TF212 15

2.3.5 Calculation function At this point you decide which signal is to be displayed or calculated in the Function block window for the Primary value (PV, AI Function block 1). Fig. 2-15 Calculation function SV_1 Display: the value measured by sensor 1 SV_2 Display: the value measured by sensor 2 SV_1 - SV_2 Difference Calculation and display: value measured by sensor 1 minus value measured by sensor 2 SV_2 - SV_1 Difference Calculation and display: value measured by sensor 2 minus value measured by sensor 1 ½ x (SC_1 + SV_2) Average Calculation and display: Average of values measured by sensor 1 and sensor 2 ½ x (SV_1 + SV_2) Average but SV_1 or SV_2 if the other is wrong Calculation and display: Average of values measured by sensor 1 and sensor 2 (but display of value measured by only one sensor (channel), if one of the sensors is faulty) IMPORTANT The option of making a selection is subject to a plausibility check: If the status for channel 2 is set to off in the Configuration window, then all options for sensor 2 (SV_2) will be disabled. Units Here, you can set the units that the measurements should be displayed in. If a unit is selected here, this selection is valid for all displays in the Function block window. If none is selected then the units can be selected separately for each of the 3 displays in the Function block window. IMPORTANT The option of making a selection is subject to a plausibility check: The possible units depend on the type of sensor selected. 16 Device Type Manager DTM for TF12, TF212 46/11-50 EN

2.3.6 Function block (UV) By activating the tab Device TF12 View Function block (UV) the following window will appear: Operation Fig. 2-16 Display of values measured by sensors 1 and 2 In this window the values measured by sensor 1 and sensor 2 as well as the value according to the function selected in the Transducer block window will be displayed. Display The values measured will be shown as text as well as in a bar diagram. The color of the bar provides information about each alarm state. The limits of the bar diagram display (displayed section of measurement range) are set under Additional parameters. IMPORTANT The percentages specified under the bars relate to the display limits set under Additional parameters. Units The units can be set in the associated selection list as long as the units have not already been set in the Transducer block window. 46/11-50 EN Device Type Manager DTM for TF12, TF212 17

Zoom function (magnifying glass) In addition to the limits set under Additional parameters the bar diagram can also be modified. The Display limits field will appear. Use the mouse to press the Magnifying glass. The display limits can now be entered in the units selected for display. Click on OK to confirm Fig. 2-17 Zoom function (magnifying glass) The activation of the zoom function will be shown by the display of the <<<Zoom active>>> line. To switch the zoom function off, click on the magnifying glass again. Additional parameters Additional parameters can be set for each of the 3 displays (value measured, sensor 1, sensor 2). After pressing each Additional parameters button, the adjacent window will open. Fig. 2-18 Data entry window for Additional parameters IMPORTANT The upper and lower limits to the measuring range show the permissible measurement range of the associated sensor. This display does not appear in All function block 1: value measured. lower process limit (EU 0 %) To enter the lower display limit of the bar diagram (corresponds to 0 % of the display range) upper process limit (EU 100 %) To enter the upper display limit of the bar diagram (corresponds to 100 % of the display range) Hysteresis (Alarm) To enter the hysteresis for the threshold value (alarms) in % Damping To enter the signal damping in seconds (s) Simulation Switching the simulation on/off (see below) 18 Device Type Manager DTM for TF12, TF212 46/11-50 EN

Simulation Via a selection list (inactive or inactive) a simulation of measurements can be switched on/off. To enter the values for the simulation and to set the units via a selection list. Press the Close button to close the window. Fig. 2-19 Simulation Alarms (thresholds) 4 alarms (thresholds) can be set for each of the 3 displays (value measured, sensor 1, sensor 2). Entries are made underneath the bar diagrams in the corresponding fields. The alarm points set are also shown above the bar diagrams as tabs, as long as they lie within the selected display range. Fig. 2-20 Alarms LO_LO_LIM LO_LIM HI_HI_LIM HI_LIM lower main alarm lower provisional alarm upper provisional alarm upper main alarm The color of the bar provides information about the associated alarm state: green yellow red no alarm lower or upper provisional alarm lower or upper main alarm 46/11-50 EN Device Type Manager DTM for TF12, TF212 19

Diagnosis (UV) By activating the tab Device TF12 View Diagnosis (UV) the following window will appear: Fig. 2-21 Diagnosis In this window the various current states of the transducer as well as of the maximum of 2 sensors will be displayed. NO / green Yes / red no fault, everything is OK fault If there's a fault, the status will be displayed in the bar at the foot of the window. The Industrial IT wordmark is a registered or pending trademark of ABB. ABB has Sales & Customer Support expertise in over 100 countries worldwide. www.abb.com The Company s policy is one of continuous product improvement and the right is reserved to modify the information contained herein without notice. Printed in the Fed. Rep. of Germany (11.2005) ABB 2005 46/11-50 EN ABB Ltd. Salterbeck Trading Estate Workington, Cumbria CA14 5DS UK Tel: +44 (0) 1946 830 611 Fax: +44 (0) 1946 832 661 ABB Inc. 125 E. County Line Road Warminster, PA 18974 USA Tel: +1 215 674 6000 Fax: +1 215 674 7183 ABB Automation Products GmbH Borsigstr. 2 63755 Alzenau Germany Tel: +49 551 905-534 Fax: +49 551 905-555 CCC-Support.deapr@de.abb.com