Control relays. K mini-control relays. Conforming to standards IEC/EN , , NF C , VDE 0660 UL, CSA, DEMKO, NEMKO, SEMKO

Similar documents
IEC Type Industrial Control Relays; TeSys D-Line, K-Line, and SK-Line K-Line Ordering Informaiton

Mini contactors. K 3-pole contactors for motor control, 6 and 9 A Utilisation category AC-3 Control circuit : a.c. a.c. control contactors (1)

7 - Control relays. Control relays. b k control relays

K-Line Mini - Contactors, Overload Relays and Accessories

TeSys D contactors. Selection guide. All types of control system. Rated operational voltage. Rated operational power in AC-3. Auxiliary contacts

Control relays and plug-in control relays

TeSys contactors From 115 to 2750 A

3 Pole Contactors with AC operating coils

ontrol and rotection omponents

TeSys SK, K, D. Technical Data for Designers. Contents

The technical guide TeSys D

RE7RB13MW adjustable off-delay timing relay s V AC DC - 2OC

RE7YA12BU time delay relay for star-delta starter s - 24 V AC DC - 2OC

Plug-in relays RH control relays Instantaneous (RHN) and latching (RHK)

RM4TA32 three-phase network control relay RM4-T - range V

RE8TA31BU industrial timing relay s - type A - 24 V AC/DC, V AC - 1 C/O

RE7YA12BU. Main. Contacts type and composition Component name Time delay type. 24 V AC/DC at 50/60 Hz V AC/DCat 50/60 Hz

RE8YG31BUTQ industrial timing relay s - type Qc - 24 V AC/DC, V AC - 1C/O

ABR1S102B. Main. Contacts type and composition [Uc] control circuit voltage Control circuit type

RE8YG31BUTQ industrial timing relay s - type Qc - 24 V AC/DC, V AC - 1C/O

RM4JA01F current measurement relay RM4-J - range ma V AC

TeSys IEC Contactors and Overload Relays

RM4TR31 three-phase network control relay RM4-T - range V

IEC Type Industrial Control Relays Control Relays CA2D and CA3D AC and DC Relays

RM4JA32MW current measurement relay RM4-J - range A V AC DC

RE7RM11BU off-delay timing relay with control contact s - 24 V AC DC - 1OC

NF44E-.. / NFZ44E-.. Contactor Relays AC / DC Operated - with Screw Terminals

RM4UA33M voltage measurement relay RM4-U - range V V AC

ABE7R16S210 sub-base - soldered electromechanical relays ABE7-16 channels - relay 10 mm

RM4JA31M current measurement relay RM4-J - range ma V AC

TeSys contactors Component parts for assembling reversing contactors for motor control or low speed - high speed starters

RM4LA32M liquid level control relay RM4-L V AC

ABE7R16S210 sub-base - soldered electromechanical relays ABE7-16 channels - relay 10 mm

TeSys protection components

RM35UB3. Product data sheet Characteristics. voltage control relay RM35-U - range V AC. Main. Complementary

Micro Contactor MA Series

RM17UB3. Product data sheet Characteristics. voltage control relay RM17-U - range V AC. Main. Complementary

Zelio Relay - plug-in relays

Motor protection relays

Zelio Control-modular measurement and control relays 1

02/11/2015

Solid-state relay (SSR) advantages. Solid-state relays

3 - Interfaces. Contents 0. Interfaces for discrete signals. Selection guide... page 3/2. # Electromechanical interface modules...

DB eps. See page opposite for mounting possibilities according to the contactor type EN 5/78. Version : 20.0

Zelio Relay - plug-in relays 6

K1C024B body for BCD encoded output switch - 1 pole A - for Ø 22 mm

RE9RA21MW7 off-delay timing relay s V AC -

XB4BW73731B5 green flush/red projecting illuminated double-headed pushbutton Ø22 1NO+1NC 24V

RM17UAS. Product datasheet Characteristics. voltage control relay RM17-U - range V DC. Main. Complementary. Price* : 70.

Mini Contactors. Mini Contactor Relays 4-pole 20 Auxiliary Contact Blocks. Interface Contactor Relays. Mini Contactors 22 Auxiliary Contact Blocks

RE17LAMW on-delay timing relay - 1 s..100 h V AC/ DC - solid state output

RM35TF V AC

1 - Control and signalling units

XB4BK123B5. Product data sheet Characteristics. Complete illuminated selector switch. position stay put 1NO+1NC 24V. Main.

Description Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA

RUC industrial relays of small dimensions

RUC industrial relays of small dimensions

RE17LCBM off-delay timing relay - control - 1 s..100 h V - solid state output

ABS2EC01EB input interface module mm - solid state - 24 V DC

For hoisting and mechanical handling, types XCR and XCK-MR For conveyor belt shift monitoring, type XCR-T

RM17TG. Main. Product or component type. Product specific application. Relay monitored parameters. Switching capacity in VA

02/11/2015

Square D General Purpose Relays

ZB5FG09 flush mounted selector switch head key pos stay put

RE17LAMW on-delay timing relay - 1 s..100 h V AC/DC - solid state output

Mini Contactors & Overloads

RUC industrial relays of small dimensions

29 $ Manual Motor Starters FREESHIPPING. MOTOR CONTROLS 25. Features: MMS-32H Frame. MMS-63H Frame.

K1D004ACH cam switch - 4-pole A - for Ø 22 mm

4 C/O. Contact material AgNi AgNi gold-plated Nominal contact current Inrush current

K1D011B body for BCD encoded output switch - 1 pole A - for Ø 22 mm

TeSys contactors. Pre-assembled. Pre-wired power connections. For connection by spring terminals. Instantaneous auxiliary contacts per contactor

RM35LM33MW liquid level control relay RM35-L V AC/DC

XCKP2145N12 limit switch XCKP - th.plastic roller lever var.length - 1NC+1NO - snap - 1/2NPT

XB4BW73731B5 green flush/red projecting illuminated doubleheaded pushbutton Ø22 1NO+1NC 24V

K1D012ULH cam changeover switch - 2-pole A - screw mounting

RM35LM33MW liquid level control relay RM35-L V AC/DC

RPM42P7 power plug-in relay - Zelio RPM - 4 C/O V AC - 15 A - with LED

Switching Power Supply S8E1. Ordering Information. Compact and Economical Switching Power Supply

Electronic timer CT-SDS.23 Star-delta change-over with 2 n/o contacts

RM17TG. Main. Product or component type. Product specific application. Relay monitored parameters. Switching capacity in VA 250 V AC

XCKJ10541H29 limit switch XCKJ - th.plastic roller lever var. length - 1NC+1NO - snap - M20

XB4BS542 red Ø40 Emergency switching off pushbutton Ø22 latching turn release 1NC

XB5AS8445 red Ø40 Emergency stop, switching off Ø22 trigger latching turn release 1NO+1NC

Model Number Structure

XB4BW33B5 green flush complete illum pushbutton Ø22 spring return 1NO+1NC 24V

RM35TF. Main. Product or component type. Product specific application. Relay monitored parameters 250 V AC 5 A AC

Electronic timer CT-ERS.21

G3PC. Model Number Structure. Solid State Relays with Failure Detection Function. Model Number Legend

08/07/2015

XCKS141H29 limit switch XCKS - th.plastic roller lever var. length - 1NC+1NO - snap - M20

XCKD3918P16EX limit switch XCKD - roller lever - 2NC + NO - ATEX/IECEx

XCKJ10559H7 limit switch XCKJ - thermoplastic round rod lever 6 mm - 1NC+1NO - snap - 1/2NPT

Safety automation system solutions 0

Electronic timer CT-ARS.11

RUC-M industrial relays for DC loads

K1B004TLH cam switch - 1 pole A - screw mounting

XB4BL Main. Device short name. Fixing collar material. Shape of signaling unit head. Contacts type and composition

XPSMP11123P module XPS-MP - 2 independent functions - 24 V DC

K1F037MCH cam voltmeter switch - 3L and 3L-N A - for Ø 22 mm

Transcription:

Characteristics Environment Conforming to standards IEC/EN 0947-1, 0947-5-1, NF C 3-140, VDE 00 Approvals UL, CSA, DEMKO, NEMKO, SEMKO Vertical axis Horizontal axis Operating position 180 Without derating Without derating Possible positions for CA2-K only, with derating, call our Customer information centre on 0870 08 8 08. Connection Min Max Max to IEC/EN 0947 Screw clamp connections Solid cable mm 2 1 x 1.5 2 x 4 1 x 4 + 1 x 2.5 Flexible cable without cable end mm 2 1 x 0.75 2 x 4 2 x 2.5 Flexible cable with cable end mm 2 1 x 0.34 1 x 1.5 + 1 x 2.5 1 x 1.5 + 1 x 2.5 Spring terminal connections Solid cable mm 2 1 x 0.75 1 x 1.5 2 x 1.5 Flexible cable without cable end mm 2 1 x 0.75 1 x 1.5 2 x 1.5 Faston connectors Clip mm 2 x 2.8 or 1 x.35 Solder pins for printed With locating device between circuit board power circuit and control circuit 4 mm x 35 microns Tightening torque Philips head n 2 and Ø N.m 0.8 1.3 Terminal referencing Conforming to standards EN 50005 and EN 50011 Up to 8 contacts Protective treatment Conforming to IEC/EN 008 (DIN 5001) TC (Klimafest, Climateproof) Degree of protection Conforming to VDE 010 Protection against direct finger contact (devices with screw clamp terminals or pins for printed circuit board) Ambient air temperature Storage C - 50...+ 80 around the device Operation C - 25...+ 50 Maximum operating altitude Without derating m 2000 Vibration resistance Control relay open 2 gn 5...300 Hz Control relay closed 4 gn Flame resistance Conforming to UL 94 Self-extinguishing material V1 Conforming to NF F 1-101 and 1-102 Conforming to requirement 2 Shock resistance Control relay open 10 gn (half sine wave, 11 ms) Control relay closed 15 gn.2 Safe circuit separation Conforming to VDE 010 and IEC/EN 053 VLSV (Very Low Safety Voltage), up to 400 V Control circuit characteristics Type of control relay CA2-K CA3-K CA4-K Rated control circuit voltage (Uc) V a 12...90 c 12...250 c 12...120 Control voltage limits For operation 0.8...1.15 Uc 0.8...1.15 Uc 0.7...1.3 Uc ( 50 C) single-voltage coil For drop-out 0.2 Uc 0.1 Uc 0.1 Uc Mechanical durability at Uc 50/0 Hz coil 10 In millions of operating cycles Standard c coil 20 Wide range, low consumption c coil 30 Maximum operating rate In operating cycles per hour 10,000 10,000 000 Average consumption Inrush 30 VA 3 W 1.8 W at 20 C and at Uc Sealed 4.5 VA 3 W 1.8 W Heat dissipation W 1.3 3 1.8 Between coil energisation and Operating time - opening of the N/C contacts ms 5...15 25...35 25...35 at 20 C and at Uc - closing of the N/O contacts ms 10...20 30...40 30...40 Between coil de-energisation and - opening of the N/O contacts ms 10...20 10 10...20 - closing of the N/C contacts ms 15...25 15 15...25 Maximum immunity to micro breaks ms 2 2 2 References: pages /10 and /11 page /14 page /15 /8 Schneider Electric

Characteristics Contact characteristics of mini-control relays and instantaneous contact blocks Number of contacts On CAp-K 4 On LA1-K 2 or 4 for CA2-K and CA3-K: 2 for CA4-K Rated operational voltage (Ue) Up to V 90 Rated insulation voltage (Ui) Conforming to IEC/EN 0947-1, IEC/EN 0947-5-1 V 90 Conforming to VDE 0110 group C V 750 Conforming to CSA C 22-2 n 14 V 00 Conventional thermal current (Ith) For ambient temperature 50 C A 10 Operational current frequency Hz Up to 400 Minimum switching capacity U min (DIN 19 240) V 17 I min ma 5 Short-circuit protection Conforming to IEC/EN 0947-1 & VDE 00, gg fuse A 10 Rated making capacity Conforming to IEC/EN 0947-1 I rms A 110 Overload current Permissible for 1 s A 80 500 ms A 90 100 ms A 110 Insulation resistance MΩ > 10 Make before break distance CAp-K and LA1-K: linked contacts mm 0.5 (see schemes, page /15) as per INRS, BIA and CNA specifications Operational power of contacts Conforming to IEC/EN 0947-5-1 a.c. supply, category AC-15 Electrical durability (valid up to 300 operating cycles per hour) on an inductive load such as the coil of an electromagnet: making current (cos ϕ 0.7) = 10 times breaking current (cos ϕ 0.4). 110/ 220/ 380/ 00/ V 24 48 127 230 400 440 90 1 million operating cycles VA 48 9 240 440 800 880 1200 3 million operating cycles VA 17 34 8 1 288 317 500 10 million operating cycles VA 7 14 3 120 132 200 Occasional making capacity VA 1000 2050 5000 10,000 14,000 13,000 9000 d.c. supply, category DC-13 Electrical durability (valid up to 1200 operating cycles per hour) on an inductive load such as the coil of an electromagnet, without economy resistor, the time constant increasing with the load. V 24 48 110 220 440 00 W 120 80 0 52 51 50 W 55 38 30 28 2 25 W 15 11 9 8 7 W 720 00 400 300 230 200 1 Breaking limit of contacts valid for: Power broken in VA - maximum of 50 operating cycles at 10 s intervals 1 000 (breaking current = making current 10 000 x cos ϕ 0.7). 8000 2 Electrical durability of contacts 000 5000 for: 4000-1 million operating cycles (2a), 3000-3 million operating cycles (2b), - 10 million operating cycles (2c). 2000 3 Breaking limit of contacts valid for: - maximum of 20 operating cycles at 10 s intervals with current passing for 0.5 s per operating cycle. 4 Thermal limit. 1000 800 00 500 400 300 200 100 80 0 40 2b 24 48 110 220 1 4 2a 120 2c 380 500 440 90 V Time constant in ms 250 200 140 100 50 20 Power broken in W 1000 700 500 300 200 100 80 0 50 40 30 20 10 8 4 3 2a 2b 2c 12 24 48 110 220 440 00 V.2 References: page /12 page /14 page /15 Schneider Electric /9

References For control circuit: a.c. or d.c. a or c Mini-control relays for a.c. control circuit - Mounted on 35 mm 7 rail or Ø 4 screw fixing. - Screws in open ready-to-tighten position. Control circuit Auxiliary Basic reference. Weignt contacts Complete with code indicating control circuit voltage (1) Consumption CA2-KN40pp Screw clamp connections 4.5 VA 4 CA2-KN40pp 0.180 3 1 CA2-KN31pp 0.180 2 2 CA2-KN22pp 0.180 Spring terminal connections 4.5 VA 4 CA2-KN403pp 0.180 3 1 CA2-KN313pp 0.180 2 2 CA2-KN223pp 0.180 Faston connectors, 1 x.35 or 2 x 2.8 CA2-KN403pp 4.5 VA 4 CA2-KN407pp 0.180 3 1 CA2-KN317pp 0.180 2 2 CA2-KN227pp 0.180 Solder pins for printed circuit boards 4.5 VA 4 CA2-KN405pp 0.210 3 1 CA2-KN315pp 0.210 2 2 CA2-KN225pp 0.210 Mini-control relays for d.c. control circuit.2 CA3-KN407pp pages /8 and /9 page /14 - Mounted on 35 mm 7 rails or Ø 4 screw connections. - Screws in open ready-to-tighten position. Screw clamp connections 3 W 4 CA3-KN40pp 0.225 3 1 CA3-KN31pp 0.225 2 2 CA3-KN22pp 0.225 Spring terminal connections 3 W 4 CA3-KN403pp 0.225 3 1 CA3-KN313pp 0.225 2 2 CA3-KN223pp 0.225 Faston connectors, 1 x.35 or 2 x 2.8 3 W 4 CA3-KN407pp 0.225 3 1 CA3-KN317pp 0.225 2 2 CA3-KN227pp 0.225 Solder pins for printed circuit boards 3 W 4 CA3-KN405pp 0.255 3 1 CA3-KN315pp 0.255 2 2 CA3-KN225pp 0.255 (1) Standard control circuit voltages (for other voltages, please call our Customer information centre on 0870 08 8 08). CA2-K (0.8...1.15 Uc) (0.85...1.1 Uc) Volts a 12 20 24(2) 3 42 48 110 115 127 220/ 230 230/ 380/ 400 400/ 440 500 0/ 50/0 Hz 230 240 400 415 90 Code J7 Z7 B7 C7 D7 E7 F7 FE7 FC7 M7 P7 U7 Q7 V7 N7 R7 S7 Y7 Up to and including 240 V, coil with integral suppression device available: add 2 to the code required. Example: J72 CA3-K (0.8...1.15 Uc) Volts c 12 20 24(2) 3 48 0 72 100 110 125 200 220 230 240 250 Code JD ZD BD CD ED ND SD KD FD GD LD MD MPD MUD UD Coil with integral suppression device available: add 3 to the code required. Example: JD3. (2) When connecting an electronic sensor or timer in series with the coil of the control relay, select a 20 V coil (a control voltage code Z7, c control circuit voltage code ZD) so as to compensate for the incurred voltage drop. page /15 /10 Schneider Electric

References For control circuit: a.c. or d.c. a or c Low consumption mini-control relays (a.c. control circuit) - Mounted on 35 mm 7 rail or Ø 4 screw fixing. - Screws in open ready-to-tighten position. Control circuit Auxililary Basic reference. Weight contacts Complete with code indicating control circuit voltage (1) CA4-KN40ppp Consumption Screw clamp connections 1.8 W 4 CA4-KN40pp 0.235 3 1 CA4-KN31pp 0.235 2 2 CA4-KN22pp 0.235 Spring terminal connections 1.8 W 4 CA4-KN403pp 0.235 3 1 CA4-KN313pp 0.235 2 2 CA4-KN223pp 0.235 Faston connectors, 1 x.35 or 2 x 2.8 1.8 W 4 CA4-KN407pp 0.235 3 1 CA4-KN317pp 0.235 2 2 CA4-KN227pp 0.235 Solder pins for printed circuit boards 1.8 W 4 CA4-KN405pp 0.25 3 1 CA4-KN315pp 0.25 2 2 CA4-KN225pp 0.25 (1) Standard control circuit voltages (for other voltages, please call our Customer information centre on 0870 08 8 08). CA4-K (Wide range coil: 0.7...1.3 Uc) Volts c 12 20 24 48 72 110 120 Code JW3 ZW3 BW3 EW3 SW3 FW3 GW3.2 pages /8 and /9 page /14 page /15 Schneider Electric /11

References Instantaneous and time delay auxiliary contact blocks Instantaneous auxiliary contact blocks Clip-on front mounting, 1 block per control relay Type of connection Composition Reference Weight LA1-KN20 Screw clamp 2 LA1-KN20 0.045 2 LA1-KN02 0.045 1 1 LA1-KN11 0.045 4 LA1-KN40 (1) 0.045 3 1 LA1-KN31 (1) 0.045 2 2 LA1-KN22 (1) 0.045 1 3 LA1-KN13 (1) 0.045 4 LA1-KN04 (1) 0.045 LA1-KN40 Spring terminal 2 LA1-KN203 0.045 2 LA1-KN023 0.045 1 1 LA1-KN113 0.045 4 LA1-KN403 (1) 0.045 3 1 LA1-KN313 (1) 0.045 2 2 LA1-KN223 (1) 0.045 1 3 LA1-KN133 (1) 0.045 4 LA1-KN043 (1) 0.045 Faston connectors 2 LA1-KN207 0.045 1 x.35 2 LA1-KN027 0.045 or 2 x 2.8 1 1 LA1-KN117 0.045 4 LA1-KN407 (1) 0.045 3 1 LA1-KN317 (1) 0.045 2 2 LA1-KN227 (1) 0.045 1 3 LA1-KN137 (1) 0.045 4 LA1-KN047 (1) 0.045 Electronic time delay contact blocks LA2-KT2p - Relay output with common point changeover contact, a or c 240 V, 2 A maximum - Control voltage: 0.85...1.1 Uc - Maximum switching capacity: 250 VA or 150 W - Operating temperature: - 10...+ 0 C - Reset time: 1.5 s during the time delay period, 0.5 s after the time delay period Clip-on front mounting, 1 block per control relay Voltage Type Timing Composition Reference Weight range.2 V s a or c 24...48 On-delay 1...30 1 LA2-KT2E 0.040 a 110...240 On-delay 1...30 1 LA2-KT2U 0.040 For other electronic timers type RE7, see pages /2 to /34. (1) Block of 4 contacts for use only on CA2-K and CA3-K page /9 page /14 page /15 /12 Schneider Electric

References Suppressor modules Mounting and marking accessories Suppressor modules incorporating LED indicator Mounting Type For voltages Sold Unit Weight and connection in reference lots of Clips onto front Varistor (1) a and c 5 LA4-KE1B 0.010 of relay with 12...24 V locating device. No tools a and c 5 LA4-KE1E 0.010 required for 32...48 V connection. a and c 5 LA4-KE1FC 0.010 50...129 V a and c 5 LA4-KE1UG 0.010 130...250 V LA4-Kppp Diode c 5 LA4-KC1B 0.010 + Zener diode (2) 12...24 V LA9-D973 Mounting accessories c 5 LA4-KC1E 0.010 32...48 V RC (3) a 5 LA4-KA1U 0.010 220...250 V Description Application Sold Unit Weight in reference lots of Mounting On 1 Clip-on fixing 1 LA9-D973 0.025 plates 4 rail Marking accessories On 2 110/120 mm 10 DX1-AP25 0.05 4 rails fixing centres Description Application Sold Unit Weight in reference lots of Marker Clip-on 100 LA9-D90 0.001 holder fixing on front face Clip-in 4 maximum Strips of 25 AB1-Rp (4) 0.002 markers per relay 10 identical numbers 0 to 9.2 Strips of 25 AB1-Gp (4) 0.002 10 identical capital letters A to Z (1) Protection by limitation of the transient voltage to 2 Uc max. Maximum reduction of transient voltage peaks. Slight time delay on drop-out (1.1 to 1.5 times the normal time). (2) No overvoltage or oscillation frequency. Polarised component. Slight time delay on drop-out (1.1 to 1.5 times the normal time). (3) Protection by limitation of the transient voltage to 3 Uc max and limitation of the oscillation frequency. Slight time delay on drop-out (1.2 to 2 times the normal time). (4) Complete the reference by replacing the p with the required character. page /14 Schneider Electric /13

Dimensions, mounting Mini-control relays CA2-K, CA3-K, CA4-K On panel LA1-K On printed circuit board 8,5 === A1 35 = 50 = = 35 = 45 50 53 45 A2 Contactor pins Ø 1.55 On mounting rail AM1-DP200 or AM1-DE200 (7 35 mm).2 27 38 38 LA2-KT 45 On asymmetrical rail with clip-on mounting plates LA9-D973 DX1-AP25 DZ5-ME5 50 5 120 110 21 = 35 = 45 5 27 25 45 Electronic time delay contact blocks LA2-KT Suppressor modules LA4-K 22 On mini-control relay On mini-control relay LA4-K 38 22 pages /8 and /9 References: pages /10 to /13 page /15 /14 Schneider Electric

Schemes Mini-control relays CA2-K, CA3-K, CA4-K With integral suppression device CA4-K 4 N/O 3 N/O + 1 N/C 2 N/O + 2 N/C 2 72 82 52 2 72 82 1/NC 71/NC 81/NC 51/NC 1/NC 71/NC 81/NC 4 52 2 2 A2 14 24 34 44 A2 14 22 34 44 A2 14 22 32 44 A1 13/NO 23/NO 33/NO 43/NO A1 13/NO 21/NC 33/NO 43/NO A1 13/NO 21/NC 31/NC 43/NO +A1 4 74 84 2 74 84 2 72 84 A1 3/NO 51/NC 1/NC 1/NC 3/NO 73/NO 83/NO 1/NC 73/NO 83/NO 1/NC 71/NC 83/NO A2 Instantaneous auxiliary contact blocks LA1-K for CA2-K, CA3-K, CA4-K for CA2-K, CA3-K 2 N/O 2 N/C 1 N/O + 1 N/C 4 N/O 3 N/O + 1 N/C 2 N/O + 2 N/C LA1-KN20 LA1-KN02 LA1-KN11 LA1-KN40 LA1-KN31 LA1-KN22 LA1-KN207 LA1-KN027 LA1-KN117 LA1-KN407 LA1-KN317 LA1-KN227 1 N/O + 3 N/C 4 N/C LA1-KN13 LA1-KN04 LA1-KN137 LA1-KN047 Electronic time delay contact blocks LA2-KT Suppressor modules for CA2-K, CA3-K, CA4-K LA4-KC LA4-KE 1 C/O LA2-KT2 1 A2 15 18 + _.2 pages /8 and /9 References: pages /10 to /13 page /14 Schneider Electric /15