Molded Case Circuit Breakers and Disconnect Switches Auxiliary Contacts for NZM(H)6(B)-...

Similar documents
Molded Case Circuit Breakers and Disconnect Switches Auxiliary Contacts for Type NZMH4-...

Molded Case Circuit Breakers and Disconnect Switches Auxiliary Contacts for NZM(H)9-...

FAZ Supplementary Protectors, FAZ Miniature Circuit Breakers, P2 Disconnect Switches Overview

Approved Standards. Motor Protection Circuit Breaker (MPCB) J7MN. MPCB system (motor protection CLASS 10) Auxiliary contact modules.

Go to:

SECTION DISCONNECT SWITCHES

MOTOR PROTECTION CIRCUIT BREAKERS

3RA13, 3RA14 Contactor Assemblies

Enclosed Non-Reversing Combination Controller, AC Operation - Type 1/12K/IP66 ➏➐. Non-Metallic Type 1/12K/IP66 Enclosure (KS7-C0C4R)

3RV1 Circuit-Breakers

Enclosed Non-Reversing Combination Controller, AC Operation - Type 1/12K/IP66 ➏➐ (KS7-C0C4R) Discount Schedule F-1

IDE Load break switches for machine control Remotely trippable switch from 32 to 160 A

Miniature Circuit Breakers and Supplementary Protectors. Contents

Switch Disconnectors, Main and EMERGENCY-STOP Switches

INSITE Features Notes

Load Feeders, Motor Starters and Soft Starters

References. References. Rating (A) Référence

Sentron 3VT circuit breakers Simply Smart: First choice for power distribution

Switches 6/1. 6/4 Introduction. 6/5 5TE8 control switches. 6/7 5TE4 8 pushbuttons. 6/9 5TE8 On/Off switches. 6/11 5TE1 switch disconnectors

Description. Installation. Power supply

194E FA 32 E P11 P11 6

MSRP Price list & order form

Wiring diagrams. Content. Information for reading and graphic symbols... 5/2. Wiring diagrams of the circuit-breakers... 5/3

1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Manual Motor Protectors. XT IEC Power Control

2. bizhub Remote Access Function Support List

Rotary switches T and switchdisconnectors. reliable switching, disconnection, control and operation

Discover TeSys U motor starters open version Starter-controller Non-reversing power bases

Close Protection from Moeller. miniature branch circuit breakers miniature supplementary protectors

29 $ Manual Motor Starters FREESHIPPING. MOTOR CONTROLS 25. Features: MMS-32H Frame. MMS-63H Frame.

Approved Standards. Motor Protection Circuit Breaker (MPCB) J7MN. MPCB system (motor protection CLASS 10) Auxiliary contact modules.

7 Parts and diagrams ENWW 313

DINO-LITE SOFTWARE FOTO SCHERM MET SOFTWARE DINO-LITE SOFTWARE

J7MN. Ordering Information. Motor Protection Circuit Breaker. Model Number Legend. MPCB system. Options. Motor Protection Circuit Breaker J7MN I-1

AThink future. Switch to green. Mini Panel Board. Cost-effective, space-saving board up to 400A.

Inkjet Printer UX Series PREMIUM CLASS. Coding Solutions by Hitachi

American Philatelic Society Translation Committee. Annual Report Prepared by Bobby Liao

Interlock Switches. Selection Guide. HS7A-DMC Magnetic Safety Switches

Complete UL/CSA Disconnect Switch Kits

Protection Equipment

Intelligent Operator Panel for SINAMICS G converters siemens.com/sinamics-accessories

Siemens AG RA6 Fuseless Compact Starters. Catalog News LV 1 N April 2008 SIRIUS.

MESP TECHNICAL SPECIFICATION FOR A RECTIFIER UNIT CONTROL & PROTECTION SYSTEM FOR USE IN THE 1500V DC TRACTION SYSTEM

Technical Guide. Safety Applications. For Immediate Delivery call KMParts.com at (866) Building Automation. Industrial Automation

MiCOM P123R. Overcurrent Relays P123R/EN AD/A11. Upgrade Documentation

AThink future. Switch to green. MCCB Panel Boards 400A / 630A / 800A.

Electrical auxiliaries for ic60, iid, idpn Vigi, isw-na, RCA and ARA

M-bus web server. Meters and Energy Cost Allocation WTV676-HB6035

Motors Automation Energy Transmission & Distribution Coatings. DWB Molded Case Circuit Breakers DWB

LV4000U LCD Pole Display

PORTABLE VIDEO BORESCOPE. User Manual

tapcon 230 user-friendly, FleXiBle and reliable. transformer control

8 Parts and diagrams. Chapter contents. Ordering parts and supplies. Accessories. Covers. Internal components. Tray 2 pickup assembly

Power consumption In operation At rest For wire sizing

QuickSpecs. HP Z inch 4K UHD Display. Technical Specifications. Front. 1. Power LED

Room Controllers. SER8300 Line Voltage Fan Coil Room Controller with SC3000 Relay Pack

Indicator, round, raised, full face with plastic matt chrome bezel, 22.5 mm mounting, lamp block included. Yellow Green

PERCENT OF RATED CURRENT

Time Delay Values (E-Series)

UX Twin Nozzle Series. Inkjet Printer SPEED & QUALITY. Hitachi Industrial Equipment Product Brochure

PowerFlex 400 AC Drive Guide Specification

Simple solutions for control technology

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

vacon 100 hvac for indoor climate control

60103 Circuit Breaker

K1K015NZ4 cam stepping switch - 2-pole A - screw mounting

Products :: Circuit Protection :: Hydraulic/Magnetic Circuit Breakers

Magnetic and Hydraulic-Magnetic Circuit Breaker

EN TECHNICAL MANUAL. Audio module Art and Art. 1622L

INSITE Features Notes

Motor protection circuit breakers

DECONTACTOR METAL 20 A/30 A/50 A/90 A

UL 489 Cable-In / Cable-Out Branch Circuit Breaker

Redline. Extensions. Display contacts. Function S. Display contact CA. Function. Add-on Devices T3.2

5 Parts List. Parts Lists 8570MFP Covers PL MFP Covers Covers PL Covers Imaging PL 2.0 Imaging...

MG24434 Supplementary Protector SUPPLEMENTARY PROTECTOR, 240VAC, 16A, CIRCUIT BREAKER TYPE: STANDARD

Thermal-Magnetic Circuit Breaker 2216-S

63 to 125 A. Functions. Conformity standards. General characteristics. Changeover switches SIRCO VM1 changeover switches.

Pressure and crowning control as standard

E-Series General Specifications

Compact Coded Magnetic Safety Interlock Switch and Control Units

K1F006ALH cam switch - 6-pole A - screw mounting

DINO-LITE ESD-SAFE PRODUCT RANGE FOR: THE ELECTRONICS INDUSTRY

Selection Guide. Control Circuit and Load Protection. Allen-Bradley 1489-M2C020

Product Guide. UL 1077 DIN Rail Supplementary Protectors

Issued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog

Industrial Controls Product Catalog RA64 / 3RA65 up to 32 A for mounting rail, surface,

GV-Hot Swap Recording Server System V5 (Rev.D) 4U, 20-Bay

K1F003MCH cam ammeter switch - 3 circuits A - for Ø 22 mm

IEC Contactors. Auxiliary Contact Blocks GENERAL

WMS SUPPLEMENTARY PROTECTORS

UL 489 DIN Rail Miniature Circuit Breakers

4 COMBINATION SIRIUS. SIRIUS 3RA6 Compact Starters 4/2. General data

1492-SP Supplementary Protectors

Microsoft Store badge guidelines. October 2017

Free-Stand Universal-Cutout Disconnects Type 12 Modular Free-Stand Disconnects and Accessories

1.3. Miniature Circuit Breakers and Supplementary Protectors. Contents. WMZS Circuit Breaker. UL 1077 DIN Rail Supplementary Protectors

3 LCD EXPLODED VIEWS. Screw's DISASSEMBLY. Note. Ver REAR SECTION. 2 5 (Note 2) 2(Hole) 6 (Note 2) 1 #156/#159 X 6

European Year 2012 for Active Ageing and Solidarity between Generations. Graphic guidelines

Section 4 Ground-Fault Protection Devices

UL 489 DIN Rail Miniature Circuit Breakers

Transcription:

Circuit Breakers, Disconnect Switches, Molded Case Switches 09/064 Moeller Electric Corporation Auxiliary Contacts for. Contacts Type Suffix Price N.O. = normally open N.C. = normally closed when ordering with basic N.O. N.C. device Standard auxiliary contacts 2 2 +NHI22-NZM4/6-NA 082860 Early-make auxiliary contacts 2 form C (change over) contacts +002-NZM6-NA 082861 Notes Combination possibilities of auxiliary contacts: NHI RHI Dots in each row represent the types which can be combined together. Dashes indicate incompatibility. Auxiliary contacts must be ordered with the device. Handle-operated early-make auxiliary contacts 2 form C (change over) contacts +002-NZM6-NA 082862 Trip-indicating auxiliary contacts 2 form C (change over) contacts +RHI002-NZM6-NA 082863 NHI RHI NHI standard auxiliary contacts operate simultaneously with the main contacts. Typically used for signalling or switching auxiliary circuits such as a control circuit. early make auxiliary contacts lead the main contacts when switching ON as well as switching OFF. Typically used for load shedding purposes or in conjunction with voltage trips in control circuits. Position of auxiliary contacts Same as main contacts Same contact position in both OFF and Tripped position of the device Main contacts U closed u open Switching ON k r I Switching OFF k R I NHI NHI handle operated auxiliary early-make contacts operate in advance of the main contacts, shortly after the handle has left the OFF position. Typically used to convert the manual actuation of the switch into a control function for circuit interlocking purposes. Same contact position in both ON and Tripped position of the device RHI trip-indicating auxiliary contacts work independently of the normal ON and OFF operations of the device, switching only when the device has tripped due to overloads, overcurrents or other tripping functions such as voltage trips. Operates only when device is tripped RHI RHI Tripped position + R I NHI RHI and -NZM6 operate in similar fashion during switching ON and OFF

Moeller Electric Corporation Voltage Trips for Shunt trips Short-time duty rating 53 Rated Control Voltage Type Suffix Price Notes to be ordered with device only V/Hz 51 Short time actuation can be achieved by using the NHI auxiliary contact ahead in series with the shunt trip coil Cannot be mounted together with undervoltage trips. AC 120V 60Hz +A-NZM4/6(120V60HZ) 082867 208V 60Hz +A-NZM4/6(208V60HZ) 082868 240V 60Hz +A-NZM4/6(240V60HZ) 082869 480V 60Hz +A-NZM4/6(480V60HZ) 082870 600V 60Hz +A-NZM4/6(600V60HZ) 082871 Shunt trips are typically used to electrically trip the device from a remote location 09/065 Circuit Breakers, Disconnect Switches, Molded Case DC 24V +A-NZM4/6(24VDC) 082228 Undervoltage trips, non-delayed Continuous duty rating U 52 < 51 Power can be applied to the undervoltage trip using early-make auxiliary contacts in series with the undervoltage trip coil. Cannot be mounted together with shunt trips. AC 120V 60Hz +U-NZM4/6(120V60HZ) 082872 208V 60Hz +U-NZM4/6(208V60HZ) 082873 240V 60Hz +U-NZM4/6(240V60HZ) 082874 480V 60Hz +U-NZM4/6(480V60HZ) 082875 600V 60Hz +U-NZM4/6(600V60HZ) 082876 Undervoltage trips will electrically trip the device open under power loss and can be used for control interlocking purposes, e.g. to disconnect the main switch in Emergency-Stop circuits. DC 24V +U-NZM4/6(24VDC) 082242 1) Voltage trips must be ordered with the device.

Circuit Breakers, Disconnect Switches, Molded Case Switches 09/066 Moeller Electric Corporation Accessories for Handle for open or panel mounted devices Fastens to shaft, not padlockable Handle for cover/door interlocking Color of handle for use with Type Suffix Type Price when ordering with basic device when ordering separately 1) gray black Degree of protection UL/NEMA 3R, 12; IEC IP 55 Door coupling rotary handle. For front mounting in doors and covers. Can be locked in the OFF position with up to 3 padlocks (hasp thickness 6-8mm). Door/cover interlocking supplied standard set in OFF position. Can be field modified for setting in ON position. 3 distinct handle positions: OFF - + (tripped) - ON +H6U 060765 +H6U-SW 064370 H6U 093191 H6U-SW 034176 gray NZMH4-...,, black NZMH4-...,, for Emergency-Stop function red-yellow NZMH4-...,, Extension shaft Mounting depth 150 400 mm, extends shaft length by 266 mm. Only one extension shaft possible. Can also be used with mechanical interlock. NZMH4-... +H6-NA 005346 +H6-SW-NA 106023 +RH6-NA 094994 +A-NZM6 058392 H6-NA 088445 H6-SW-NA 088865 RH6-NA 026874 A-NZM6 026643 Padlocking accessory Enables the device to be padlocked OFF when the panel door is open. Accommodates up to 3 padlocks (hasp thickness 6-8 mm). A limit switch (Type AT0) can also be installed for signalling or electrical interlocking purposes. +SVB-NZM6 051238 SVB-NZM6 048253 Switch position indicator indicates position of switch when panel door is open Maintenance handle To actuate the device when the panel door is open NZMH4-...,, +SA-NZM6 056019 +H6UZ 065883 SA-NZM6 045867 H6UZ 065884 Mechanical interlock For mechanical interlocking of two devices. Requires two handles, one for each switch. Order separately +KV-2NZM6 052566 KV-2NZM6 071864 1) Accessories are field installable.

Moeller Electric Corporation 09/067 Accessories for. Rear operation shafts For side panel mounting where device is only accessible from the rear (e.g. sides of enclosure panels). Must be combined with H...R-NA rear operation handle. Factory installed only. Order with device Operating handle for rear operation Color of handle for use with Type Suffix Type Price when ordered with basic device when ordered separately 1) Used with rear operation shaft. Degree of protection UL/NEMA 3R, 12; IEC IP 55 Can be locked in the OFF position with up to 3 padlocks (hasp thickness 6-8mm). No cover/door interlocking provisions. 3 distinct handle positions: OFF - + (tripped) - ON +R-NZM6 002964 - Circuit Breakers, Disconnect Switches, Molded Case gray NZMH4-... black NZMH4-... for Emergency-Stop functions red-yellow NZMH4-... Legend plate (for mounting with operating handle) Silver-colored +H6-R-NA 005347 +H6-R-SW-NA 106022 +RH6-R-NA 095224 H6-R-NA 059551 H6-R-SW-NA 201665 RH6-R-NA 069043 Specify desired text. Black lettering; height of letters 3.5, 5 and 7mm NZMH4-...,, +ZSSOND-NZM6 075003 ZSSOND-NZM6 064984 Blank for engraving or printing NZMH4-...,, +ZS60-NZM6 077376 ZS60-NZM6 064913 Main disconnect warning plate Silver-colored, black lettering. English inscription: Main Switch - Open only in OFF Position English NZMH4-...,, +ZS62-NZM6 053654 ZS62-NZM6 044161 French +ZS63-NZM6 056027 ZS63-NZM6 046534 For other languages, see below 2) +ZS...-NZM6 952552 ZS...-NZM6 915218 1) Accessories shown in this column are field installable 2) Engraved main disconnect warning plates are available in the following languages: 61 German 64 Bulgarian 65 Danish 66 Finnish 67 Dutch 68 Italian 69 Greek 70 Norwegian 71 Polish 72 Portuguese 73 Romanian 74 Russian 75 Swedish 76 Serbo-Croatian 77 Spanish 78 Czech 79 Turkish 80 Hungarian 81 Afrikaans Insert language key number into type number Example: Warning plate in Italian language: ZS 68-NZM 6

Circuit Breakers, Disconnect Switches, Molded Case Switches 09/068 Moeller Electric Corporation Accessories for Main disconnect switch assembly kits for CE marked control panels per IEC/EN 60 204-1 switches with dual UL/CSA and IEC/EN ratings are suitable for use as main disconnect switches in control panels that must be CE marked and designed to comply with the Machinery Directive Standard EN 60 204-1. The kits shown below, ordered with the device or separately, will provide the necessary accessories to fulfill the main disconnect switch function for these applications. Note: in cases where the main disconnect switch also fulfills the Emergency-Stop function, please specify kits containing red handle and yellow backing plate assemblies. Main disconnect handle with door/cover interlock for front mounting, Red color handle with yellow backing plate for Emergency-Stop function, Terminal cover Main switch marking plate Type Suffix Type Price when ordered with basic device when ordered separately 1) +V-NZM6 070257 V-NZM6 086257 Main disconnect handle for rear operated switches, red in color with yellow backing plate for Emergency-Stop function, supplied with steel plate for panel side mounting, Terminal cover Main switch marking plate +EA-NZM6 072630 EA-NZM6 043322 Main disconnect switch assembly kit, black For front mounting Same as V-NZM6, except that the main disconnect handle is black in color with silver backing plate for standard, non-emergency-stop function +V-NZM6-SW 054136 V-NZM6-SW 054148 For rear operated switches Same as EA-NZM6, except that the main disconnect handle is black in color with silver backing plate for standard, non-emergency-stop function +EA-NZM6-SW 054144 EA-NZM6-SW 054156 1) Kits are field-installable

Moeller Electric Corporation Accessories for Control circuit tap-off terminals Supplementary terminals attached to main terminals. 3 connections top and bottom. Factory addition only, must be ordered with device Terminal cover Provides shock hazard protection in the area of the field wiring power terminals. Can be used at top or bottom, one cover per side. Mandatory requirement on the supply side of main disconnect switches to provide protection against accidental contact with line side feed. Type Suffix Type Price when ordering with basic device when ordering separately 1) +ST-NA 092761 +H-NZM6 098733 H-NZM6 093188 09/069 Circuit Breakers, Disconnect Switches, Molded Case 1) Accessories are field installable