ADJUSTMENTS & OPTIONAL SETTINGS (CONT.)

Similar documents
ITB a. ITCB-DV & HV a ITCB-TWIN HV

AK2100 PROGRAMMABLE CONTROLLER

3000 CONTROLLER TRAINING MANUAL. April 26, 2012 Software Version

Operations Manual. Covering Pitco P/N Single Vat Control With Set-Back and Lane Selection and Filter Data Functions

Service Manual for Pitco P/N s (Full Vat) and (Split Vat) I12+ Cooking Computer for ROV Fryers

Agency: 8oz cups/hr 236ml cups/hr. BUNN reserves the right to change specifications and product design without notice. Such revisions do not entitle

Dexter Washer Programing. Part # 8533-***-*** 03/14

INSTALLATION AND OPERATING MANUAL BUNN-O-MATIC CORPORATION POST OFFICE BOX 3227 SPRINGFIELD, ILLINOIS PHONE: (217) FAX:

Operations Manual. Solstice I12 Cooking Computer. Covering. Single Vat (P/N ) and Dual Vat (P/N )

ULTRASTAT23 Operating Instructions For the MEC-110 with ENHANCED SMS 10-Product Cooking Controller

FlexPak 3000 Drive Operator Interface Module (OIM) User s Guide

American Hakko Products, Inc.

pco 3 Controller User Manual ASPX Digital Scroll, Air Packaged Chiller For Version MCDSV_A02

ENGLISH. Chem-Trak System Programming Rev: REL (06/04) - ENMA_CHEMTRACK PROGRAMMING Page 1 of 20

ExBC software C5.7.X. User manual. Part no Issue no 04 Date 04/2018

SERIES CMT CARBON MONOXIDE GAS TRANSMITTER

BEP 600-ACSM AC SYSTEMS MONITOR. Installation and Operating Instructions. Page 1

Installation Instructions

Phase 8.3 and 8.4 Rev 2.2 and Rev 2.3 Microprocessor User s Manual

Installation Instructions

INSTRUCTION MANUAL STATION CONTROLLER SC1000 MOTOR PROTECTION ELECTRONICS, INC.

Installation Instructions

USER GUIDE. Salinity Meter Pen Style Water Quality Meter. Model EC170

MB 780 / MB790. Service Guide OkiData Americas, Inc.

BACVIEW MANUAL Software Version 3.06 INSTALLATION AND OPERATION MANUAL

AMBIFLEX MF626 - USER GUIDE

TS InteliSwitch Digital Time Switch 24VDC/VAC

Verifoam Conductivity Tester

OPERATOR'S MANUAL Generator Paralleling Controller, GPC-3 - Generator Protection Unit, GPU-3/GPU-3 Hydro - Paralleling and Protection Unit, PPU-3

Dryer. M720 Programming and Operation Manual. July 15, 2015 Revision 1.51

Fox Thermal Instruments, Inc.

GOLD SERIES DVD/CD Duplicator Manual

PROGRAMMING INSTRUCTIONS

BASIC OPERATION OF L&L KILNS WITH A DYNATROL

SilverLeaf RV-C Control System Training Manual

MultiLane Operations Manual

Using MDC Manager to Manage Power Settings

Owners Manual: G-Tel 525(Wire-line)

Data Grip Primary Button Functions

Instruction Manual. ROYTRONIC EXCEL Series AD9 Programming Guide Electronic Metering Pumps

Quick Start Installation and User Manual

VTR8300 User Interface Guide VTR8300 Room Controller Series

METERING/DISPLAY MANUAL

On-Premise Elite Programming Manual

MultiTherm Shaker. Operations Manual Item: H5000-H and H5000-HC

2009 Mercury Marine SmartCraft Monitor 5.0v

Sure Coat Application Controller


User's Guide. ExStik EC500. ph/conductivity / TDS / Salinity / Temperature Meter EC500

Industrial Weighing Systems

XRS 3000 Controller Reference Guide V-2

Blu-ray/DVD/CD Duplicator Control Manual. User s Manual

Owner s Manual. Digital Player Addendum. For Heat Siphon Swimming Pool Heat Pumps

Visit us at Back to the Extech DO600 Product Page

User Manual. ExStik EC500. ph/conductivity / TDS / Salinity / Temperature Meter EC500. Additional User Manual Translations available at

Instruction manual of the controller unit. PCS ph-redox-chlorine-temp PCS ph-oxygen-temp PCS ph-redox-temp

SC2000 MOTOR PROTECTION ELECTRONICS, INC. INSTRUCTION MANUAL. (407) Phone: Website:

MULTISPENSE 2000 W/TOUCHSCREEN CONTROLLER MODULE Page 3-1. Table Of Contents. Section Description Page #

CardMaster Programming Guide Rev CardMaster Operators Guide. CardMaster Installation Manual. CardMaster Service Guide

Knight-Trak II Tunnel-Relay Programming Manual

Stage Fog Machine User Manual

MCA 1400 Documentation

1. Operating Conditions

C600 2-wire Conductivity Transmitter

DDS-12DW Benchtop Conductivity Meter. Instruction Manual BANTE INSTRUMENTS CO., LTD

Connecting to your Caravan or Motorhome

SC2000 MOTOR PROTECTION ELECTRONICS, INC. INSTRUCTION MANUAL. Phone: (407) Fax: (407) Vulcan Road Apopka, Florida 32703

MEDALLION INSTRUMENTATION SYSTEMS MasterCraft Viper system

CL-8. ADVANTECH Commercial Laundry Products Software User s Manual SOFTWARE MANUAL PART A

Trident & Trident X2 PD765

ADDENDUM WCFX. Vision 2020i Touch Screen Controller. - a1 - Vision 2020i Controller

System Controller Programming Manual

CONTENTS I. DEVICE SETUP II. INSTALLATION III. UNINSTALL RETAIL MODE

Service Bulletin SB685. Date: 8/18/2017 TriPac EVOLUTION Communications Update Bulletin Location: TSA Info Central\Service Bulletins

PowerView Model PV780. Operations Manual Section 78

Section EE - 1. Service Console. - Service Console Map - Navigating the Service Console

Operating manual. Washer extractors W465H, W475H/M/S, W485M/S, W4105H/M/S, W4130H/M/S, W4180H/M/S, W4240H, W4250M/S, W4300H, W4330M/S, W4280X, W4350X

Operating the meter 13. j h g. 4.1 Backside layout Pin assignments RS232 connection

R7284 Series. Electronic Oil Primary

PROCESS ANALYSERS. SERVOTOUGH OxyExact (2200) Operator Manual. Part Number: 02210/001A Revision: 4 Language: UK English

2012 Mercury Marine MercMonitor Version M eng i

FilterQuick/OCF Statistics Check and Error Log

Programming and Installation Manual

SGT-600 SAFETY GROUND TESTER

774 Oven Sample Processor

Service Manual. I8 Water Cooker Computer. Covering (P/N PP11375)

Bluelab ph Meter TM Instruction Manual

ECLIPSE. Online and Downloadable Product Manuals and Quick Start Guides are available at

User Manual Version

NetMaster. Programming. Washer-Extractors Cabinet Hardmount Basic Programming Guide Refer to Page 7 for Model Numbers

Temperature control unit

N IO T C N U F S M S EN ENGLISH LB EDITION JULY 2011

Robe X1 FT PRO USER MANUAL. Version: 1.1. ROBE Lighting s.r.o. Czech Republic

Bluelab Combo Meter TM Instruction Manual. combo metertm.

Advanced User s Guide

ProLogic L02 Operating Instructions

Instruction Manual Mi 160 Bench Meter

MRC-NT Microprocessor Rapper Control Operating Manual

121000TP227S USER'S MANUAL

High Motor Current Shutdown High Motor Current Warning Low Motor Current Shutdown Compressor Auxiliary Shutdown

Transcription:

ENABLE ADS? DONE NEW AD? TE: The available characters are: A through Z 0 through 9! " # $ % & ' ( ) * +, -. / : ; < = >? @ 2 LINES 16 CHARS AVAILABLE SCROL THRU ALPHA NEXT NEXT LETTER WRITE TOP LINE? WRITE BTM LINE? A SCROLL DONE NEXT ENTER SERVICE #? SAVE? EDIT ADVERTISEMENT T SAVED! ADVERTISEMENT SETUP COMPLETE ENTER SERVICE #? Page 7

SERVICE NUMBER This function allows the operator to enter in the telephone number to call if service is needed. The service number will be displayed anytime there is a fault message displayed. Procedure to enter the service number: 1. Press and hold the right hidden switch until the display reads "BrewWIZARD" then release. Press and release the right hidden switch until the display reads: "ENTER SERVICE #?" 2. Press and release "" switch. The display will now read "SCROL THRU #'S NEXT - > NEXT NUMBER", followed by "SCROLL DONE NEXT". 3. Press the "SCROLL" switch to increment the number. When the desired number is shown, press and release the "NEXT" switch to move to the next digit in the phone number. 4. Repeat Step 3 until the entire number is entered. 5. Press and release the "DONE" switch. The display will now read "EXITING BrewWIZARD" and then "ENTER PASSWORD". ENTER SERVICE #? SCROL THRU #'s NEXT NEXT NUMBER SCROLL DONE NEXT PROGRAMMING FUNCTIONS - LEVEL 2 ENTER PASSWORD This function allows the operator to enter a 3 digit number to access LEVEL 2. If no number has been pre programmed (0 0 0), then access is allowed by pressing and releasing the right hidden switch. Procedure to enter the "PASSWORD": 1. Press and release the "Digital" switch to increment the first digit. 2. Press and release the "Brewer" switch to increment the second digit. 3. Press and release the "Control" switch to increment the third digit. 4. Press and release the right hidden switch. If the correct password was entered, the display will now read "SET PASSWORD". If the wrong password was entered, the unit will revert back to the main screen. EXITING BrewWIZARD ENTER PASSWORD 0 0 0 Page 8

PROGRAMMING FUNCTIONS - LEVEL 2 (cont.) TE: Access to the remaining functions in LEVEL 2 is intended for trained service personnel only. More in depth information can be found in the Axiom Service Manual 39132.0000 SET PASSWORD 0 0 0 Any 3 digit number may be programmed to prevent unauthorized access of LEVEL 2. BE CAREFUL TO USE A CODE YOU WILL REMEMBER! SET LANGUAGE Choose between English or Spanish. After selecting "", press either ( + ) or ( - ) to select, then choose "" again when asked, "ARE YOU SURE?" UNITS METRIC DONE ENG Choose between English or Metric units. Display will read: "CHANGING UNITS WILL CAUSE" "ALL SETUP INFO TO BE LOST" "ARE YOU SURE?" " ". TE: If the brewer is set for Metric Units, displays will be different. (ex: Brew oz will become Brew Liters, F will be C). SET TEMP: 200 Adjusts brew tank temperature. RANGE: (185 to 205 F) or (85 to 96 C) SET READY: 195 This function sets the minimum temperature allowable to start a brew cycle. Range: (2 to 20 F) or (2 to 10 C) below the set temperature. The water must be at the "READY" temperature or higher for the display to indicate "READY TO BREW". ENTER ASSET #? This function allows the you to enter in an optional asset number. This can be useful for tracking the usage or service of an individual machine within a group. Page 9

PROGRAMMING FUNCTIONS - LEVEL 2 (cont.) SET PULSE BREW? ADJUSTMENTS & OPTIONAL SETTINGS (CONT.) DRIP TIME 0:30 "EASY PULSE BREW" times: Min: Base brew time + 40 seconds Max: Base brew time + 3:00 minutes This function allows the sprayhead to pulse on and off during a brew cycle. These times can be set two different ways. The first is by setting the total brew time in the "EASY PULSE BREW" screen. The other option allows the actual times to be entered in the "MANUAL PULSE BREW" screen. TE: This will overwrite settings in "BREW METER". Adjusts the DRIP TIME (time from end of sprayhead flow to when liquid stops dripping from the funnel). When the brew cycle is complete, the display will show "DRIPPING" and will countdown the time until the funnel empties. RANGE: "OFF" or 0:05 to 4:00 minutes ENABLE CLEAN DONE Set the time before a cleaning alert will be displayed. RANGE: 1 to 30 days Enabl EnergySavr DONE Enables the mode function and sets the idle time. Then choose to have the tank heater(s) turn off, or reduce the tank temp to (140 F) or (60 C) once the set idle time has expired. Range: 0.5 to 24.0 hrs EnableFreshTimer DONE ENABL WARMER OFF DONE 0 REFILL 155 Enables the "FRESHNESS ALERT!" message and sets the expiration time. The expiration time is the amount of time the product is allowed to sit in the server before an alert message is displayed. Range: 0.5 to 4.0 hrs Sets the amount of time a warmer will remain on after being turned on. Each warmer has an independent timer and is affected by its corresponding switch. TE: The lower "Brew" warmer timer is restarted when brew switch is pressed. Range: 15mins to 6.0 hrs in 15 min increments. Adjusts the sensitivity of the refill circuit. Water in different geographical locations can have different conductivities. Make sure the water in the tank is touching the refill probe. TE: Always make sure that the # on the right is larger than the # on the left when water is contacting the tank refill probe. Page 10

PROGRAMMING FUNCTIONS - LEVEL 2 (cont.) ENABLE BrewLOGIC DONE Go to SPRAY OZ/M: PLACE BREWER IN FINAL LOCATION The BrewLogic system allows the brewer to be calibrated to high mineral locations and compensate as deposits build up internally. Press, then press DONE. Follow the prompts. Pertains only to software version 1.07 & above! Select a sturdy, level location. Brewer must not be bumped during calibration! CALIBRATE W? Select for calibration. Selecting warns of accuracy risk ACCURACY RISK!!! OK CAL. Select CAL. to start calibration procedure. Selecting OK will skip to level probe calibration screen. Go to CAL LP1-LP2 TOO HOT-WILL COOL TANK W Automatically checks to see if tank temperature is between 130-170 F (54-76 C) PRESS BREW WHEN CONTAINER READY Verify brew funnel and decanter/airpot/thermal server (depending on which model you have) are in place. Then press the "BREW START" button. COOLING TANK PLEASE WAIT Message will be displayed while dispense is being performed. Tank heaters are turned off and the unit will dispense for ~1 minute to cool tank temperature. (CONT.) Page 11

PROGRAMMING FUNCTIONS - LEVEL 2 (cont.) CONTAINER READY? QUIT Go to CAL LP1-LP2 CALIBRATE SPRAY PRESS BREW START When the dispensing finishes, empty the decanter/server and place back under brew funnel. Select for calibration. Selecting QUIT will skip to level probe calibration screen. Press the "BREW START" button. Will perform the sprayhead flow-rate calibration as well as the level probe calibration. Brewer must not be bumped during calibration! WaitingTilCycle 4 CYCLE x COMPLETE Machine will dispense volume between upper probe and lower probe 4 times. (The total dispense will be about half of a decanter) Brewer must not be bumped during calibration! ENTER OZ XX.X Enter volume dispensed into container. Use the (+) to increase the numeric value or (-) to decrease. SPRAY OZ/M: LP1-LP2 OZ XX.X XX.X Displays sprayhead flow-rate and volume of water between the upper and lower level probes. CALIBRATE LP1-LP2 Allows you to perform calibration again if you want to verify results. Go to BREW COUNTERS Go to CAL LP1-LP2 Page 12

PROGRAMMING FUNCTIONS - LEVEL 2 (cont.) SPRAY OZ/M: 25.0 CALIBRATE FLOW? BREW COUNTERS? View or enter the actual flow rate coming out of the sprayhead. This is used to tell the internal controller how fast the water is flowing. Use the "CALIBRATE FLOW" screen to obtain the most current flow rate. Range: (3.0 to 75.0 oz) or (100 to 2200ml) This function provides a 60 second test mode to capture water from the sprayhead. This measurement will then give you the numbers to enter into the "SPRAY OZ/M: xx" screen above.te: Should be performed after deliming and/or changing sprayhead. (Will not display when "BrewLogic" is enabled) Tracks the total number of brew cycles completed. There is one reset-able counter, and one life counter that is not reset-able SERVICE TOOLS? Allows the testing of individual components and the ability to check the membrane switches for proper function. (Diagnostic tool for troubleshooting purposes only) FACTORY DEFAULTS Reset ALL of the previously entered brew settings, ad message, calibrations, etc. Factory-set default values will replace ALL previous settings. TE: Items not affected; Service #, Password, Language, Units, Asset #, Counters and Serial Number. INITIAL FACTORY DEFAULT VALUES Brew Lockout ENABLE ENERGY SAVER - BREW 64 OZ (2.0L) ENABLE FRESH TIMER - BREW METER 1 ENABLE WARMER OFF - ENABLE ADS REFILL - 155 PASSWORD 0 SPRAY 25.0 oz/m (739ml/M) Language English Software Version 1.07 & above Units English BrewLogic OFF SET TEMP 200 F (93 C) SET READY 195 F (90 C) ENTER ASSET # - 0 PULSE BREW - DISABLED DRIP TIME - 0:30 ENABLE CLEAN - Page 13