File (19 inches) for RS3 FIC I/Os (AI/AO) migration toward a new system

Similar documents
Redundant System Redundant System P9-1-1

Submittal Data Sheet WAGO Node for itm

5B Series 16 Channel Backplane 5B01 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Cube67 - Modular I/O station

AMC 8 & IOC 8T. Analog Monitoring Card Type AMC 8 and Input / Output Card Type IOC 8T FEATURES

R1M-GH THERMOCOUPLE & DC INPUT MODULE MODEL. Remote I/O R1M Series. (16 points)

FIRELEC Migration Solution. PROVOX > DeltaV. PIA (PROVOX Interface Adapters) FMS-PVXCL-DV-2. Discrete Inputs

Specification for temperature sensor calibration setup

S-series Mass Connection Solutions

Analog Devices: 6B Series Backplanes : 6B Series : IOS Subsystems : Market Solutions

M-series Traditional I/O

MODEL: R1M-GH. PC Recorders R1M Series

S-series Electronic Marshalling

Prisma II Platform. Optoelectronics

DeltaV Electronic Marshalling

I-7520: RS-232 to RS-485. Input: RS-232 protocol Output:RS-485/RS-422 Speed: Self Tuner 'inside, auto switching baud rate, 300~ BPS

INTRINSICALLY SAFE INSTRUMENTATION FOR HAZARDOUS AREAS

M-series DeltaV Controller Interface for RS3 I/O

Isolated Process Current Input with Loop Power 7B35

S-series Electronic Marshalling

Isolated Process Current Input 7B32 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

SmartBlock I/O Module HE579MIX577/977 Isolated 4/8 Analog Inputs 2/4 Analog Outputs

NMEA Expander. Operation And. Installation Manual

XT-9100 Technical Bulletin

M-series Intrinsically Safe I/O

Isolated, Process Current Output 7B39 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

IST ULTRASTAB Power Supply for high precision transducers

Model 3724 Dual 1x30 FET Multiplexer Card

PCD3.C90. Date Modification Asked by: Version E/A Bus Connector PCD2.K106 change to PCD3.K106 Müller.R 1.1

Rack Mount 17 &19 Console User Manual

Temperature measurement board, optically isolated, 16/8/4 channels for thermocouples, Pt100, RTD, 18-bit

S800 I/O ABB Automation

Isolated Voltage Input 7B31 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

CONTROL TECHNOLOGY INC Middlebrook Pike, Knoxville, TN Phone FAX

Trident and Trident X2 Digital Process and Temperature Panel Meter

M-series DeltaV Controller Interface for PROVOX I/O

S-series Electronic Marshalling for Migrations

S-Series DeltaV Controller Interface for PROVOX I/O

S-series Electronic Marshalling

AMC8 and IOC8T Analog monitoring card and input / output card

DeltaV IS Electronic Marshalling

DeltaV Electronic Marshalling for Migrations

Isolated, Voltage or Current Input 7B30 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

XPSMF35. Product data sheet Characteristics. Preventa safety PLC compact - Profibus DP protocol. Main. Complementary. Safety module name

S-series IS Electronic Marshalling

AIO AH-PCI. Features. Packing List. 12-bits Analog I/O Board (High Gain) for PCI AIO AH-PCI 1. Ver.1.04

MODEL: R1M-P4. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)

F1000 User's Manual. (Version: V1.01)

8~14-Port Managed Ethernet Switch

LVX Control Unit. Features:

Time Counters mini "h", DC Version

PHOENIX CONTACT - 05/2007

SCM5B. SLX200 Data Acquisition System. isolynx. Data Acquisition Systems. Visit our website Features

MXIO. Compact I/O module. Summary. Application Compact I/O module for data acquisition and HVAC control systems. Function

DeltaV S-series Traditional I/O

UNT1100 Series. Binary Output Jumpers AO2 AO1 AO3 AO4 AOCM AOCM AOCM AOCM AO1. AI Switches Job Information N2 Address. Ref N2+ N2- ADDR 0 = ALL OPEN

Isolated, Voltage or Current Input 7B41 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

POINT I/O Family. Chapter. Overview

AIO UE3-PE. Features. 1MSPS 12-bit Analog I/O Board for PCI Express AIO UE3-PE 1. Ver.1.01

8B SLX300 Data Acquisition System

Micro-DCI TM 53SL6000 Micro-Mite Single Loop Controllers

TM172PBG42R Modicon M172 Performance Blind 42 I/Os, Ethernet, Modbus

INTEGRATED SYSTEMS AND CONTROL, INC. User s Hardware Manual. PCMNET V 7. xx

PCIe-20AO8C500K. 20-Bit 8-Output 500KSPS Precision Wideband. PCI Express Short-Card Analog Output Module

iologik 4000 Series (M) Modules

Cisco Prisma II Platform

SmartBlock I/O Module HE579MIX102 Isolated 6 Relay, 12 DC Inputs, 4 Analog Inputs

V E6B Snap-in I/O Module

USER S MANUAL Power Supply for Backplane Vdc

Thermocouple Input Module Product Specifications and Installation Data

V E3XBW Snap-in I/O Module

USB VGA KVM Console Extender w/ Serial & Audio Over Cat5 UTP ft

OBSOLETE. Isolated, Linearized, Thermocouple Input 3B47 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Diagnostics (Logical) Diagnostics (Physical)

IST ULTRASTAB Power Supply for IT/ITN ULTRASTAB transducers

S-series IS Electronic Marshalling

DF PROFI II PCIe. Installation Instructions V Project No.: 5302 Doc-ID.: DF PROFI II PCIe KUNBUS

TCP A3. Description. Module with 3 thermocouple inputs. Datasheet

12-36 VDC/12-24 VAC Power Option 4-Digit Display, 0.56 (14.2 mm) or 1.20 (30.5 mm)

E1/T1 Rate Converters

SNAP Serial Communication Modules. SNAP Serial Communication Modules. Features. Description

16-Channel Digital Input Termination Card 24Vdc

IO-DI8-TO8 I/O Expansion Module 8 Inputs, 8 Outputs

iothinx 4500 Series (45MR) Modules

AD16-16(PCI)EV. Features. High-Resolution Analog Input Board for PCI AD16-16(PCI)EV 1. Ver.1.02

DIO-1616TB-PE. Features. Packing List. PCI Express-compliant High-Speed TTL level Opto-isolated Digital I/O DIO-1616TB-PE 1. Ver.1.

EH-RIO IP67 Profibus-DP I/O modules

VM600 modular CPU card and input /output card

FLEX Ex Spring Clamp Terminal Base

Signal Conditioning Modules and Terminal Boards

Safety Barriers. CEAG safety barriers can be used for all kinds of instrumentation applications.

AD12-16(PCI)EV. Features. Analog Input Board for PCI AD12-16(PCI)EV 1. Ver.1.02

SCB-68 User Guide. 68-Pin Shielded Desktop Connector Block

VL BPC MINI. A configurable industrial computer platform. Data sheet 2930_en_F. 1 Description. 2 Features

Fiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers

16-Channel Digital Input Termination Card 24Vdc

16-Channel 16-Bit PMC Analog I/O Board

smart meters... 6 panel meters... 7 field displays... 8 display types loop powered displays TRANSMITTERS & CONVERTERS...

About the FLEX I/O and FLEX Ex I/O Systems

/8 DIN Universal Process Indicator

Transcription:

BC-FIC-AIAO-01 File (19 inches) for RS3 FIC I/Os (AI/AO) migration toward a new system Bulletin Rev : 2016_01 Description : The file BC-FIC-AIAO-01-1 or BC-FIC-AIAO-01-2 can replace, in the same location, the RS3 MPC Analog Card Cage and provides the connection utilities toward a new DCS or PLC. I/O configuration is made for each channel using suitable jumpers. The existing analog card cage was structured with 8 slots for I/O cards, each card with 2 or 3 channels : AI (2/4 wires) / AO card : o Channel 1 and 2 > AI o Channel 3 > AI or AO RTD (3 wires) or Thermocouple card (2 wires) : Channel 1 and Channel 2 Pulse card : o Channel 1 and 2 > PCI or PCO o Channel 3 > AO The existing marshalling panels and their associated cables, are kept in place and listed as follow : European Analog Marshalling Panel : 10P5459-0001 (without fuse) - 10P5462-0001 (with fuses) Multistrategy Marshalling Panel : 1984-2415-0001 Multistrategy Marshalling Panel : 1984-2412-000X Analog Marshalling Panel : 1984-2448-000X The field wiring is kept in place without any disconnection. Page 1/10

The connections with the new input or output cards are made using SUBD connectors as follow : Analog Input signals : o One SUBD37 pin male connector for 16 Analog inputs. o One SUBD25 pin male connector for 8 Analog inputs. Analog Output signals : o One SUBD25 pin male connector for 8 Analog outputs. Bulletin Rev : 2016_01 RTD Analog Input signals : o Two SUBD25 pin male connectors for 16 RTD Analog inputs (8 channels per connector). Pulse Count Input signals : o Four SUBD9 pin male connectors for 16 PCI (4 channels per connector). Pulse Output signals : o One SUBD25 pin male connector for 16 PCO. The power supply of the existing RS3 Analog Card Cage is kept in order to supply Pulse Inputs with free contacts. Product options : Option -1 : BC-FIC-AIAO-01-1 : Without power supply for Pulse Count Inputs Option -2 : BC-FIC-AIAO-01-2 : With redundant power supply for Pulse Count Inputs Page 2/10

Technical specifications : Dimensions : Power supply : Wide: 482,6 mm (19 inches) Redundant Power Supply 18 36 Vdc (used only for PCI free contact) Depth: 211.50 mm Consumption : 240mA@24,0Vdc Height : 177.50mm (compatible with 4U) Redundant DC/DC converters (outputs 12Vdc) protected by 1A fuses Weight : Each output of DC/DC converter is indicated by a green Led. 2,0Kg DC/DC converter integrity is monitored using a free voltage contact Mounting : available on a screw terminal In place of the existing RS3 legacy card cage Temperature range : Configuration of input/output : Operating: 0 C to 60 C Configuration of I/Os is done using jumpers located on the main PCB Storage: -20 C to 70 C See view1 for configuration Humidity : Up to 90% (no condensation) Connection to the DCS or to the PLC : Analog Inputs : Channel specifications toward the DCS or PLC : By two SUBD (37 and 25 pin) male connectors UNC 4-40 Analog Inputs : 4-20mA (2/4 wires) protected by fuse 250mA female lock and shielded suitable cables Analog Outputs : 4-20mA protected by fuse 250mA Connector P1 (37 pin) : 16 Channels > 101/102 to 801/802 RTD Analog Inputs : 3 wires Connector P2 (25 pin) : 8 Channels > 103 to 803 Thermocouple Analog Inputs : 2 wires Analog Outputs : Remark : For thermocouples, the cold junction compensation (CJC) was By one SUBD25 pin male connector UNC 4-40 female lock managed in the existing RS3 marshalling panel using an RTD and shielded suitable cable compensator using one channel among the 16 available. Connector P3 : 8 Channels > 103 to 803 With the BC-FIC-AIAO-01-1, the DCS or PLC I/O structure must be in RTD and Thermocouple Analog Input signals : Accordance with such I/O functionality (mix of RTDs and TH) By two SUBD25 pin male connector UNC 4-40 female lock Pulse Outputs : DCs or PLC card has to be in accordance with the and shielded suitable cable existing connected field device Connector P4 : 8 channels > 101/102 to 401/402 Remark : The existing RS3 card had the following capabilities : Connector P5 : 8 channels > 501/502 to 801/802 Output range : 0 1KHz Pulse Output signals : Output voltage : 21 to 24Vdc By one SUBD25 pin male connector UNC 4-40 female lock Max current : 20mA and shielded suitable cable Pulse Count Inputs : Free contact or voltage input Connector P6 : 16 Channels > 101/102 to 801/802 1 ) Free contact : Supplied by internal power supply 12Vdc Pulse Count Input signals : (see section Power supply here above) By four SUBD9 pin male connector UNC 4-40 female lock 2 ) Voltage input : DCs or PLC card has to be in accordance with the and shielded suitable cable existing connected field device Connector P7 : 4 Channels > 101/102, 201/202 Connector P8 : 4 Channels > 301/302, 401/402 Connector P9 : 4 Channels > 501/502, 601/602 Connector P10 : 4 Channels > 701/702, 801/802 FIRELEC provides cables with suitable connectors or free labelled wires in accordance with DCS or PLC I/O cards used. Page 3/10

View 1 : BC-FIC-AIAO-01-1 without power supply for Pulse Count Inputs 1 x SUBD 25 pin connector for Analog Inputs : P2 : 8 Channels 103 to 803 Jumpers T101 to T803 for 2W / 4W analog input configuration. 2W (2 wires) : The DCS or PLC card supply the transmitter 4W (4 wires) : The transmitter is supplied externally See Page 7 1 x SUBD 25 pin connector for Analog Inputs : P3 : 8 Channels 103 to 803 2 x SUBD 25 pin connector for RTD Inputs : P4 : 8 Channels 101/102 to 401/402 P5 : 8 Channels 501/502 to 801/802 1 x SUBD 25 pin connector for Pulse Outputs : P6 : 16 Channels 101/102 to 801/802 HE1050 I/O connector used for the connection of the existing I/O cable (from the field) AI Fuses AO Fuses AI / AO / PCI / PCO / RTD configuration area AI Fuses 4 x SUBD 9 pin connector for Pulse Count Inputs : P7 : Channels 1 to 4 / 101/102/201/202 P8 : Channels 5 to 8 / 301/302/401/402 P9 : Channels 9 to 12 / 501/502/601/602 P10 : Channels 13 to 16 / 701/702/801/802 Not used for option -1 of the BC-FIC-AIAO-01-1 Power supply area not used for option -1 of the BC-FIC-AIAO-01-1 PCI Configuration jumpers for Dry Contact or Voltage Inputs 1 x SUBD 37 pin connector for Analog Inputs : P1 : 16 Channels 101/102 to 801/802 Page 4/10

View 2 : BC-FIC-AIAO-01-2 with power supply for Pulse Count Inputs 1 x SUBD 25 pin connector for Analog Inputs : P2 : 8 Channels 103 to 803 Jumpers T101 to T803 for 2W / 4W analog input configuration. 2W (2 wires) : The DCS or PLC card supply the transmitter 4W (4 wires) : The transmitter is supplied externally See Page 7 1 x SUBD 25 pin connector for Analog Inputs : P3 : 8 Channels 103 to 803 2 x SUBD 25 pin connector for RTD Inputs : P4 : 8 Channels 101/102 to 401/402 P5 : 8 Channels 501/502 to 801/802 1 x SUBD 25 pin connector for Pulse Outputs : P6 : 16 Channels 101/102 to 801/802 HE1050 I/O connector used for the connection of the existing I/O cable (from the field) AI Fuses AO Fuses AI / AO / PCI / PCO / RTD configuration area AI Fuses PCI Configuration jumpers for Dry Contact or Voltage Inputs 4 x SUBD 9 pin connector for Pulse Count Inputs : P7 : Channels 1 to 4 / 101/102/201/202 P8 : Channels 5 to 8 / 301/302/401/402 P9 : Channels 9 to 12 / 501/502/601/602 P10 : Channels 13 to 16 / 701/702/801/802 Power supply used for option -2 of the BC-FIC- AIAO-01-2 Redundant Power Supplies are to be installed in order to supply Pulse Count Inputs in Dry Contact versions. A : Primary PS (18 to 36Vdc) B : Secondary PS (18 to 36Vdc) RTN : Return / Signal Common J2 : Connector for new PS, if J949 / J950 not used. J949 / J950 : Connector for existing PS RS3 connector J1 : Free voltage contact for PS monitoring Note : PS has to be applied either on J2 or on J949/J950 (never on both of them) 1 x SUBD 37 pin connector for Analog Inputs : P1 : 16 Channels 101/102 to 801/802 Page 5/10

1. CONFIGURATION PROCEDURE OF : Bulletin Rev : 2016_01 1.1. INPUT/OUTPUT TYPE CONFIGURATION USING DOUBLE-JUMPERS According to the existing RS3 MPC Analog Card Cage, each channel has to be configured using suitable jumpers. As indicated here below, the hardware configuration is divided into 8 groups of I/Os matching with 8 I/O cards of the existing RS3 MPC Analog Card Cage. The jumpers are clearly indicated by screen printing on the PCB. As default, the BC-FIC-AIAO-01-1 is provided with all I/Os configured in AI mode. It user has to take care of the right/wrong way of jumpers. Refer to the indications here below for I/O configuration : 1.2. ANALOG INPUT TYPE CONFIGURATION USING SINGLE-JUMPERS Each analog input channel has to be defined as a 2W or 4W transmitter. 2W (Two wire transmitter) : Transmitter is supplied by the input card of the DCS or PLC 4W (Four wire transmitter) : Transmitter is supplied by an external source located at the field or in the marshalling cabinets Refer to the indications here at the right for configuration using the jumpers T101 to T803. Page 6/10

1.3. PCI TYPE CONFIGURATION USING DOUBLE-JUMPERS To manage existing PCI, the option -2 (with redundant power supply) of the BC-FIC-AIAO-01-2 is required. Each Pulse Count Input channel has to be defined as a Dry Contact Input or Voltage Input. Dry Contact Input : Field Dry Contact is powered by the input of the redundant PS of the BC-FIC-AIAO-01-2 Voltage Input : Input is directly applied to the DCS or PLC input card of through the BC-FIC-AIAO-01-2 Refer to the indications here below for configuration using the jumpers K101 to K802. 2. INSTALLATION PROCEDURE : 2.1. REMOVING OF THE EXISTING CABLES : Disconnect the I/O cable from its connector J453. Disconnect all communication cables and remove them, as there are not to be used anymore in the new architecture. Power cables connected on the existing J949 and J950 have to be managed as follow : The existing RS3 MPC analog card cage had no Pulse Count Input cards : Power cables connected on the existing J949 and J950 have to be removed. In that case, the BC-FIC-AIAO-01-1 doesn t require any power supply. The existing RS3 MPC analog card cage had Pulse Count Input cards : Power cables connected on the existing J949 and J950 have to be kept and reconnected on same connectors similarly labelled of the BC- FIC-AIAO-01-2 2.2. MECHANICAL OPERATIONS : Remove the fixing screws and remove the existing RS3 analog card cage. Install in the same location the and secure it. 2.3. ELECTRICAL AND WIRING OPERATIONS : In accordance with the input / output configuration, install the required I/O cables. Route and connect them to the DCS or PLC I/O cards. Connect the power cable in connector J949 and J950 if necessary. Page 7/10

Description of Analog Input Configuration with 2W transmitter supplied by PLC or DCS card. Description of Analog Input Configuration with 2W transmitter powered from PS connected on the Marshalling panel. Description of Analog Input Configuration with 3W/4W transmitter with external Power Supply (self powered transmitter). Page 8/10

3. CONFIGURATION EXAMPLES : 3.1. EXAMPLE 1 - ONLY HIGH LEVEL (4-20MA) AI AND AO : Analog Inputs Analog Outputs Group of 3 I/Os Existing RS3 - Address 101-102-103 Yes : 101-102 Yes : 103 1 Existing RS3 - Address 201-202-203 Yes : 201-202 Yes : 203 2 Existing RS3 - Address 301-302-303 Yes : 301-302 Yes : 303 3 Existing RS3 - Address 401-402-403 Yes : 401-402 Yes : 403 4 Existing RS3 - Address 501-502-503 Yes : 501-502 Yes : 503 5 Existing RS3 - Address 601-602-603 Yes : 601-602 Yes : 603 6 Existing RS3 - Address 701-702-703 Yes : 701-702 Yes : 703 7 Existing RS3 - Address 801-802-803 Yes : 801-802 Yes : 803 8 PLC or DCS Analog Input Card 16 channels No card required on connector P2 PLC or DCS Analog Output Card 8 channels Page 9/10

3.2. EXAMPLE 2 - ONLY HIGH LEVEL (4-20MA) AI AND AO : Analog Inputs Analog Outputs Group of 3 I/Os Existing RS3 - Address 101-102-103 Yes : 101-102-103 No 1 Existing RS3 - Address 201-202-203 Yes : 201-202-203 No 2 Existing RS3 - Address 301-302-303 Yes : 301-302 Yes : 303 3 Existing RS3 - Address 401-402-403 Yes : 401-402-403 No 4 Existing RS3 - Address 501-502-503 Yes : 501-502 Yes : 503 5 Existing RS3 - Address 601-602-603 Yes : 601-602-603 No 6 Existing RS3 - Address 701-702-703 Yes : 701-702 Yes : 703 7 Existing RS3 - Address 801-802-803 Yes : 801-802 Yes : 803 8 PLC or DCS Analog Input Card 16 channels PLC or DCS Analog Input Card 8 channels PLC or DCS Analog Output Card 8 channels Page 10/10