Industrial SFP/SFP Multi-Power Mode Converter

Similar documents
Converts any fiber optics type interface to any other fiber optics type interface.

This simple chassis houses one media-converter module and features an external AC power supply and also a terminal block for DC power input.

Gigabit Miniature Media Converters. Connect Gigabit Ethernet copper ports to fiber optic cable.

Multi-Power Miniature Media Converter 10/100/1000

These tiny media converters are perfect for bringing fiber to the desktop.

Choose from four different ways to power these hardened media converters.

Multi-Power Miniature Media Converter 10/100/1000 JUNE 2007 LGC322A-NPS LGC320A-NPS, LGC321A-NPS,

Add 10/100 copper ports to a High Density Media Converter Chassis.

Giga-MiniMc TX & RX USER MANUAL

PC Media Converter, Switching (TP-TX/FX)

About the LAN Extenders Warranty Federal Communication Commission Radio Frequency Interference Statement Getting to Know the LAN Extenders The LEDs

10/100 Autosensing PC Media Converter

Connects 1000BASE-T twisted-pair to 1000BASE-SX/LX fiber.

MiniMc TP-TX/FX MiniMc TP-TX/SFP. Operation Manual

Giga-MiniMc TX/FX Giga-MiniMc TX/SFP. Operation Manual

Bridge Module. Installation Guide and Users Reference Manual

McPC/Giga-MediaLinX. (PCI and Low Profile PCI Version) 10/100/1000 Mbps. Operation Manual

IE-MediaChassis/1. Operation Manual

IE-Giga-MiniMc. Operation Manual. FCC Radio Frequency Interference Statement. Limited Lifetime Warranty

Giga-MiniMc with LFPT. Operation Manual

International Headquarters. European Headquarters

PoE Giga-McBasic PoE+ Giga-McBasic with LFPT. Operation Manual

International Headquarters

SySTIUM TECHNOLOGIES. Assembly Guide. Model 133i

FiberLinX Modules Hardware Installation Manual

IE-iMcV-2xLIM, TX/SFP. Operation Manual

About PoE Compact Media Converters

LVN5200A-R2, rev. 1, Hardware Installation Guide

5/8 Port Gigabit Ethernet Switch

Installation Guide. Wyse Rx0L Thin Client Flash and RAM Upgrade Option Kit. Issue: PN: L Rev. A

Industrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541 PoE Model: KSD-541-P. Installation Guide

HD40H(X) Performance Series Camera. User Guide

4 10/100/1000T Mini-GBIC with 4 IEEE 802.3at High Power PoE Industrial Wide Temperature Switch. User Manual SISTP LRT

SP-PoE Splitter User Manual

Lantech. IPES /100TX with 4 PoE Injectors 24~48VDC Industrial Switch. User Manual

G.SHDSL NTU with Fixed Serial Interfaces

Express All-Fiber DVI. User s Manual (For M1-1000)

Allworx Tx 92/24 Telephone Expander Installation Guide

16-SLOT IN-BAND MANAGEMENT CHASSIS

Quick Start Guide. C-100 Series Switches

G.SHDSL NTU DECEMBER 2006 LB510A

6 10/100/1000TX + 2G Fiber Industrial Ethernet Switch User Manual

Daily use. indicating that the loud speakers

User Guide CPSMP VAC Power Supply Module: PointSystem CPSMC Accessory CPSMC Accessory. Contents.

8 Port Gigabit Ethernet Switch User Manual (P/N: 41NE-G3800UD0-A00)

USER GUIDE. AXIS T8120 Midspan 15 W 1-port ENGLISH

Lantech IPGC-0101DSFP. User Manual. 10/100/1000T (PoE at) to 100/1000M SFP Industrial Switch Converter

imcv-ds3/e3/sts Repeater

CSM200 Expansion Tray

Express Ethernet Switch: LB8422A-US LB8421A-US LB8424A-US

Hypercable injecteur HPOE - Industrial IEEE 802.3at Gigabit PoE Injector. User Manual. v.1.0 Jun Mail :

DS-1H05 Ethernet-over-Coax Extender. User Manual

Installation Guide. QBox-V6. Standalone/Spare V6 SDI QBox. Standalone/Spare V6 SDI QBox. Part No. A

Lantech. IPGS-0204DSFP 4 10/100/1000T PoE at/af + 2 Dual Speed SFP Industrial Unmanaged Switch

AS1008-P AS1026-P AS2008-P AS2024-P User Manual

The following symbols are used to show dangerous operation or handling. Make sure you understand them before reading the guide.

ALTAI C1N SUPER WIFI CPE INSTALLATION GUIDE. Version 1.0 Date: September, Altai Technologies Ltd. All rights reserved

High Density Media Converter System II 20-Slot Rackmount Chassis

10/100/1000T to Mini-GBIC Industrial Switch Converter 10/100/1000T to 1000SX/LX Industrial Switch Converter. AMG9011G-H (-40 to 75C) User Manual

Optical DVI Daisy-chain Extender

USB USB Data Transfer

FIBER OPTIC A/B/C/D SWITCH (LATCHING)

FIBER OPTIC A/B/C/D SWITCH (NON-LATCHING)

4. 4 x Foot Pads 5. Rack-Mount Kit

imediachassis Series imediachassis/20 imediachassis/6 imediachassis/3 Operation Manual

Installation Job Aid for Ethernet Routing Switch 5900 Series

IEC-0101FT Industrial 10/100TX to 100M-FX Slim Type Converter User Manual

Quick Start Guide. Cisco Compatible 10Gbase-LR SFP+ Transceiver with DDM, SMF, 1310 nm, 10 km, LC. Model: N286-10GLR-SLC PROTECT YOUR INVESTMENT!

KSD-800 Series. Installation Guide. Industrial 8-Port Fast Ethernet Switches with Fiber Connectivity DOC A -1-

4-port 10/100TX + 1 or 2-port 100FX Industrial Switch. User Manual

FCC Regulatory Information

FEMTOCELL MULTI-BAND SOHO B2/B4 (SS2FII)

9362 Enterprise Cell V2.2 WCDMA B2/B5. Getting Started Guide

IFS MCR-R15 Media Converter Rack User Manual

Installation Job Aid for Ethernet Routing Switch 3600 Series

FRG-3105 Series Residential Gateway

HES-3109 SERIES 9 PORTS 10/100/1000BASE-T MANAGEMENT ETHERNET SWITCH

Lightspeed Advanced Reporting Bottle Rocket Hardware Installation Guide

Modular Media Converter Installation Guide (includes 10 Mbps Ethernet, 100 Mbps Fast Ethernet and Protocol-Independent Fiber Mode Conversion Modules)

IAD18000/18001 Hardware User Manual

TruVision IP Thermal Camera Installation Guide

Quick Installation Guide

Quick Installation Guide

Lantech. IPGS-0005T /100/1000T PoE at T Industrial Unmanaged Switch. User Manual

SANnet II Family Safety, Regulatory, and Compliance Manual

TRC-190 User s Manual

AM4000D Outdoor CPE User Manual

Handset Charging Rack OpenStage WL 3 / OpenStage WL3 Plus. Installation Guide A31003-M2000-J

XBR V4 INSTALLATION AND USER GUIDE

Aruba 3000 Multi-Service Mobility Controller Series. Installation Guide

BTK-A21 Bluetooth Headset User Manual

FZ-VEBG11x. Cradle. Model No. FZ-VEBG11 1. Model No. U Universal R China 1: Area U: Universal R: China

See instructions to download and install the latest version of LinkBoxLON and the user's manual at

HES-3106-PLUS SERIES

Quick Installation Guide

TRC-190 User s Manual

Industrial 5-Port Fast Ethernet Switches. with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541. PoE Model: KSD-541-HP. Installation Guide

RS-232/RS-422 Optical Isolator

D-Link Switch User Manual. Table of Contents

SOHO Access TM Module. User Guide. SAM-SW5U: 5-port 10/100 Ethernet Switch

Transcription:

MARCH 2008 LGC300A Industrial SFP/SFP Multi-Power Mode Converter Copyright 2008. Black Box Corporation. All rights reserved 55 80619BB 00 A1 1000 Park Drive Lawrence, PA 35055 1018 724 746 5500 Fax 724 746 0746 CUSTOMER SUPPORT INFORMATION Order toll-free in the U.S.: 877-877-BBOX (outside U.S. call 724-746-5500) FREE technical support, 24 hours a day, 7 days a week: Call 724-746-5500 or fax 724-746-0746 Mail order: Black Box Corporation, 1000 Park Drive, Lawrence, PA 15055-1018 Web site: www.blackbox.com E-mail: info@blackbox.com

FCC and Industry Canada RF Interference Statements Class B Digital Device. This equipment has been tested and found to comply with the limits for a Class B computing device pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. However, there is no guarantee that interference will not occur in a particular installation. This equipment generates, uses, and can radiate radio frequency energy, and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. If this equipment does cause harmful interference to radio or telephone reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult an experienced radio/tv technician for help. CAUTION Changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment. To meet FCC requirements, shielded cables and power cords are required to connect this device to a personal computer or other Class B certified device. This digital apparatus does not exceed the Class B limits for radio noise emission from digital apparatus set out in the Radio Interference Regulation of Industry Canada. Safety Certifications UL/CUL: Listed to Safety of Information Technology Equipment, including Electrical Business Equipment. Class 1 Laser product, Luokan 1 Laserlaite, Laser Klasse 1, Appareil A Laser de Classe 1 European Directive 2002/96/EC (WEEE) requires that any equipment that bears this symbol on product or packaging must not be disposed of with unsorted municipal waste. This symbol indicates that the equipment should be disposed of separately from regular household waste. It is the consumer s responsibility to dispose of this and all equipment so marked through designated collection facilities appointed by government or local authorities. Following these steps through proper disposal and recycling will help prevent potential negative consequences to the environment and human health. For more detailed information about proper disposal, please contact local authorities, waste disposal services, or the point of purchase for this equipment. ii 9

Fiber Optic Cleaning Guidelines Fiber Optic transmitters and receivers are extremely susceptible to contamination by particles of dirt or dust, which can obstruct the optic path and cause performance degradation. Good system performance requires clean optics and connector ferrules. 1. Use fiber patch cords (or connectors, if you terminate your own fiber) only from a reputable supplier; low-quality components can cause many hard-to-diagnose problems in an installation. 2. Dust caps are installed at Black Box to ensure factory-clean optical devices. These protective caps should not be removed until the moment of connecting the fiber cable to the device. Should it be necessary to disconnect the fiber device, reinstall the protective dust caps. 3. Store spare caps in a dust-free environment such as a sealed plastic bag or box so that when reinstalled they do not introduce any contamination to the optics. 4. If you suspect that the optics have been contaminated, alternate between blasting with clean, dry, compressed air and flushing with methanol to remove particles of dirt. Electrostatic Discharge Precautions Electrostatic discharge (ESD) can cause damage to your add-in modules. Always observe the following precautions when installing or handling an add-in module or any board assembly. 1. Do not remove unit from its protective packaging until you re ready to install it. 2. Wear an ESD wrist grounding strap before handling any module or component. If you do not have a wrist strap, maintain grounded contact with the system unit throughout any procedure requiring ESD protection. 3. Hold boards by the edges only; do not touch the electronic components or gold connectors. 4. After removal, always place the boards on a grounded, static-free surface, ESD pad or in a proper ESD bag. Do not slide the board over any surface. Table of Contents FCC and Industry Canada RF Interference Statements... ii About the Industrial SFP/SFP...2 Part Number...2 Included Accessories...2 Installing the Industrial SFP/SFP...3 SFP Port Requirements...3 DIN Rail Mounting...3 Powering the Industrial SFP/SFP...4 DC Terminal Block Option...4 Cascading DC Power...4 LED Operation...5 DC Power Supply Precautions...6 Specifications...7 Standards/Compliance...7 Black Box Customer Service...7 Fiber Optic Cleaning Guidelines...8 Electrostatic Discharge Precautions...8 Safety Certifications...9 WARNING! Integrated circuits and fiber optic components are extremely susceptible to electrostatic discharge damage. Do not handle these components directly unless you are a qualified service technician and use tools and techniques that conform to accepted industry practices. 8 iii

About the Industrial SFP/SFP The Industrial SFP/SFP is a pure mode converter that converts any fiber optics type to any other fiber optics type. This product is a Protocol independent converter and is not intended for applications that require retiming or any Layer 2 functions. The Industrial SFP/SFP supports extended temperature operation. This product is applicable to Ethernet, SONET, and Fiber Channel applications. The Industrial SFP/SFP requires two small form-factor (SFP) modules (sold separately), which provide greater fiber flexibility in the network environment. The hot-swappable nature of the SFPs and the numerous fiber modes and types available in SFPs allow for easy configuration and future upgrading as network demands evolve. The SFP modules must be MSA compliant and support the same speed range, i.e. part numbers LFP100, LFP200, etc. The Industrial SFP/SFP operates as a mode converter only and not as a rate converter. The Industrial SFP/SFP does not provide support for copper (TX) SFPs. The key features of the Industrial SFP/SFP are Uses Miniature Media Converter Form Factor Rack Mountable with IE-PowerTray/18 available in AC or DC Supports a 7VDC to 50VDC terminal block option with cascading power Supports an external 5VDC power option (not extended temperature) Allows extended temperature range from -31 to 158 F (-35 to 70 C) Uses all standard MSA-complaint SFP devices (excluding copper SFPs) Provides extensive diagnostic LED functions Supports LinkLoss functionality Supports DIN Rail mounting Part Number Part Number LGC300A Included Accessories Description MultiPower SFP to SFP Mode Converter (SFPs sold separately) 1 AC Power Adapter 2 Clips for AC Power Adapter (1 US, 1 EU) 1 DIN-35 Rail clip & 2 screws 1 Operational Manual 1 Velcro with adhesive backing kit Integrated DC Terminal Block Specifications Operating Temperature: -31 to 158 F (-35 to 70 C) Storage Temperature: -49 to 185 F (-45 to 85 C) Shipping Weight: 0.25 lbs (0.11 kg) Dimensions: 0.83 H x 1.80 W x 3.35 D (2.11 x 4.57 x 8.51 cm) AC Wall Adapter: 100/240 ±10% VAC input, 5 VDC output @ 10 watts DC Input Voltage: +7VDC to +50VDC @ 2.5 watts. Actual current consumption may vary depending on the type of SFP modules installed. When not using the supplied AC/DC converter the externally supplied DC power must be provided from a LPS source. Standards/Compliance SFP-MSA SFP standard (September 14, 2000) SFF-8472 DDMI standard (Revision 1.0) All SFPs used in this product should be certified to IEC 60825-1. Black Box Customer Service Order toll-free in the U.S.: Call 877-877-BBOX (outside U.S. call 724-746-5500) Free technical support, 24 hours a day, 7 days a week. Call: 724-746-5500 or Fax: 724-746-0746 Mail order: Black Box Corporation 1000 Park Drive, Lawrence, PA 15055-1018 Web site: www.blackbox.com E-mail: info@blackbox.com 2 7

DC Power Supply Precautions The following precautions must be observed when installing the chassis model with an internal DC power supply. 1. Check nameplate ratings to ensure there is no overloading of supply circuits that could effect overcurrent protection and supply wiring. 2. In addition, the following must be observed: a. Connect the equipment to a 35 to 50 VDC power source that is electrically isolated from the alternating current source. The 35 to 50 VDC power source is connected to a SELV DC source. b. Route input wiring to terminal block and secure in such a manner that it is protected from damage and stress. Do not route wiring past sharp edges or moving parts. c. Incorporate a readily accessible disconnect device, with a 3mm minimum contact gap in the fixed wiring. 3. Reliable Earthing of this equipment must be maintained. Particular attention should be given to supply connections when connecting to power strips, rather than direct connections to the branch circuit. Installing the Industrial SFP/SFP The Industrial SFP/SFP installs anywhere as a standalone, table-top device or on a DIN rail. As a standalone device, install it in locations with limited space. If multiple connections are required, use an IE-PowerTray/18 enclosure (sold separately). The tray allows for 18 conversions in a 1.5 rack unit of space. The units can also be powered by daisy-chaining DC power (refer to Cascading DC Power on page 5). SFP Port Requirements NOTE Both SFPs must operate at the same rate. The Industrial SFP/SFP requires two SFP Modules of the same speed, either two Fast Ethernet (100Mbps) modules or two Gigabit Ethernet (1000Mbps) modules. DIN Rail Mounting The Industrial SFP/SFP ships from the factory with DIN clips, allowing installation on a DIN rail. It mounts perpendicular to the DIN rail (as shown). Use the supplied screws to attach the DIN clips to the Industrial SFP/SFP, and then snap the converter to the DIN rail. NOTE The DIN clips are designed for use on a DIN-35 rail. 6 3

Powering the Industrial SFP/SFP LED Operation The Industrial SFP/SFP requires an external DC power source and has three options for powering as options: Universal AC power adapter with country specific clip (not included with module version). User supplied LPS DC power via a four-position DC power block. Power from an IE-PowerTray/18 For extended temperature operation the DC terminal block must be used because the supplied AC to DC converter is not rated for extended temperature operation. The power source used with the DC terminal block should be a Limited Power Source (LPS). DC Terminal Block Option The Industrial SFP/SFP DC power option includes a 7VDC to 50VDC terminal block and a standard +5VDC mini-jack. The DC terminal block has multiple DC inputs intended for cascading DC power to an adjacent unit. Connect the power source to any one positive and one negative terminal on the Industrial SFP/SFP. NOTE When using stranded wire, the leads must be tinned. The chassis is not protected against mis-wiring; if mis-wired the chassis will not function. The chassis is internally connected to the negative power terminal. Cascading DC Power If installing multiple Industrial SFP/SFPs on a DIN rail, you can use one DC input source and then cascade from one DC terminal block to the next, until reaching the maximum electrical current available. LED PWR SD I SD 2 MSA LEDs The Industrial SFP/SFP contains four status LED indicators. Each LED is dual color and has three states: off, red, or green. A loss of signal on one SFP causes the TX of the other SFP to turn off. This action does not activate the red TX Fault LED. Color or State Red OFF Green Card does not pass the self-test. LED transmitter has an active fault. One or both SFPs are not installed or not detected. The TX inhibit must not be active if a SFP is missing. Or, both SFPs are installed, but their speed settings are different. This condition disables both SFPs. Unit does not have power. No active fault on transmitter. LOS indication on receiver. One or both SFPs are not Black Box's devices. The may still function but Black Box cannot warrant functionality or performance using non Black Box SFPs. Power is applied to the card. All internal self-test functions must pass before the PWR LED is green. Valid signal is detected by the SFP and LED transmitter is not in fault. Both SFPs are installed with Black Box's devices at the same speed setting. 4 5