Fieldbus Independent I/O Modules 8 DI DC 24 V 3.0 ms, Manual

Similar documents
Fieldbus Independent I/O Modules 2 DI DC 24 V 3.0 ms, High-Side Switching (/xxx-xxx) Manual

Fieldbus Independent I/O Modules 4 AI Pt100/ RTD , (/xxx-xxx) Manual

Fieldbus Independent I/O Modules Field Side Connection Manual

Fieldbus Independent I/O Modules 4 DO DC 24 V 0.5 A, High-Side Switching (/xxx-xxx)

Fieldbus Independent I/O Modules 4 AI DC 0-10 V, Single-Ended Manual

Fieldbus Independent I/O Modules 2 AI 4-20 ma, Single-Ended Manual

Fieldbus Independent I/O Modules End Module (/xxx-xxx) Manual

Fieldbus Independent I/O Modules 24 V DC Power Supply/Fuse/Diagn Manual

Fieldbus Independent I/O Modules SSI Transmitter Interface Manual

Fieldbus Independent I/O Modules 1 AI DMS Manual

Fieldbus Independent I/O Modules 2 AO 4-20 ma Manual

Fieldbus Independent I/O Modules Bluetooth RF Transceiver Quick Start

WAGO Remote IO with Fanuc Robot using EtherNet/IP Protocol Application note

Fieldbus Independent I/O Modules Serial Interface RS 232 C (/xxx-xxx) Manual

Redundant ethernet communication with WAGO Ethernet-Controller Application note

Using WAGO Series 750 DeviceNet IO with an A-B ControlLogix 1756-DNB Scanner Application note

Using WAGO Series 750 DeviceNet IO with an A-B SLC SDN Scanner Application note

Using the WAGO as Remote I/O with an Omron SYSMAC CJ2 Series PLC. Application note. A116700, English Version 1.1.0

Using the WAGO as Remote I/O with a ControlLogix Ethernet/IP Bridge Module Application note

Manual Version WAGO TO-PASS 761. Telecontrol Modules. 761-xxx. System Description

Using WAGO Series 750 EtherCAT coupler with CoDeSys SP Win V3 Application note

Configuring National Instruments Lab View with WAGO I/O Application note

Application Note. Building. Automation WAGO-I/O-PRO V2.3. openvpn with Linux based Devices A500880_en. Version 1.1.1

Application Note. WAGO-I/O-SYSTEM 750 Connecting energy meters with M-Bus interface to the WAGO-I/O-SYSTEM

Library for Building Automation. Module Descriptions for KNX IP Master

Application note. WAGO-I/O-SYSTEM 750 DALI Multi-Master Module Configuration of a DALI Lighting System via WAGO- I/O-PRO V2.

The HART Module on the WAGO ETHERNET Controller Application Note

Using the WagoAppEtherNetIP_Adapter library with a CompactLogix Controller A500930

Application Note. a HART Tool-routing with Emerson AMS HART over TH LINK PROFIBUS for Asset Management 1.0.0

Application Note. Connection of an WAGO ETHERNET Coupler/Controller to a S controller

Safety I/O Modules PROFIsafe 4FDO 0,5A/4FDI 24V DC PROFIsafe / Manual

WAGO-I/O-SYSTEM 750 CODESYS-2-Library WagoLibWakeOnLan.lib Wake on lan Remote wake up of network devices

Port 100Base-TX Industrial Eco Switch

Manual. WAGO-I/O-SYSTEM DI 24VDC 3.0ms Channel Digital Input Module 24 V DC, High-side switching. Version 1.1.0

Library Description. DALI_647_SpecialSensor_02.lib Specific Sensor Solutions. Version 1.0.1

Quick Install Manual BACnet /IP Controller

WAGO-I/O-SYSTEM 750 2DI 24V DC VDC,

Fieldbus Independent I/O Modules Incremental Encoder Interface Manual

Application Note. Enable port forwarding for PFC. A500840, English Version 1.0.0

Manual / Electronic Circuit Breaker DC 24 V, A. Version 1.0.0

Libraries for Building Automation. Function Blocks and Data Types for the BACnet Controller

Using PROFIsafe modules in combination with PROFIBUS-DP and PROFINET Application note

M-BUS MASTER OEM MODULE MBUS-M13

Fieldbus Independent I/O Modules DALI/DSI Master Module Manual

PROFIsafe modules V2 ipar 75x-66x/ WAGO Safety-Editor-75x Quickstart

Library for Building Automation. Function block descriptions for time- switching functions

Libraries for Building Automation. Module Descriptions for the WINSTA Sunblind Box /

Manual. WAGO-I/O-SYSTEM 750 CANopen ECO Fieldbus Coupler MCS kbaud... 1 MBaud; digital and analog signals 2.0.0

Documentation KM2042. Sixteen channel digital output module with D-Sub Connector. Version: Date:

Library for Building Automation

DeviceNet TM Fieldbus Coupler 125 Kbaud Kbaud; digital and analog signals

Libraries for Building Automation. Function Block Description for DALI Multi-Master Module

Documentation. KM2604 and KM2614. Four channel relay module. Version: Date:

WagoLib_CAN_Gateway_02.lib

Modular I/O System. DeviceNet

Library Description. MBUS_649_01.lib WAGO M-Bus Library. Version 1.0.1

Documentation. KM10xx. Terminal Modules with Digital Inputs. Version: Date:

Documentation EM2042. Sixteen Channel Digital Output Module with D-Sub Connector. Version: Date:

SINAMICS G130. Terminal Module 150 (TM150) Operating Instructions 03/2013 SINAMICS

Modular I/O-System ETHERNET TCP/IP

Modular I/O-System ETHERNET TCP/IP

Documentation ZB8610. Fan cartridge for EtherCAT and Bus Terminals. Version: Date:

Manual. WAGO-I/O-SYSTEM 750 Programmable Fieldbus Controller ETHERNET /100 Mbit/s; digital and analog signals. Version 1.1.

SINAMICS G130. Voltage Sensing Module 10 (VSM10) Operating Instructions 05/2010 SINAMICS

Library for Building Automation. Library Description for for the WAGO BACnet Library BACnet_02.lib

WAGO-I/O-SYSTEM 750 IO-Link Master

CPCI-PS24 24V-Power Supply

Modbus/TCP OPC Server

WAGO-I/O-SYSTEM 750 IO-Link Master

MINI MCR-SL-UI-2I(-SP)(-NC)

750 XTR Series TAKING IT TO THE EXTREME THE STANDARD FOR 750 XTR

SINAMICS G130. Voltage Sensing Module 10 (VSM10) Operating instructions 03/2011 SINAMICS

Operating instructions IO-Link master CabinetLine AL19xx

Modular I/O System. DeviceNet ,

Modular I/O System LONWORKS ,

Operating instructions. Standstill monitor A / / 2011

Using power measurement module with TIA A500671

TOPJOB S Sensor/Actuator Terminal Blocks Pluggable Signal Level with Push-in CAGE CLAMP Reliability

Documentation. CU20xx, CU22xx. Ethernet Switch. Version: Date:

AI561 Analog Input Module

Documentation KM2002, KM2004, KM2008. Terminal modules with digital outputs, 24 V, 0.5 A. Version: Date:

Operating instructions. Switching amplifier DN0210 DN / / 2015

Printview: End module for internal data bus extension - Item No.:

MINI MCR-SL-RPS-I-I. Repeater power supply, active. Data sheet. 1 Description

Redundancy unit CP-A RU

Documentation KL channel Digital Output Terminal, 24 V DC, 2 x 4 A/1 x 8 A. Version: Date:

DI561 Digital Input Module

BNI USB A501. User s Guide

Address. Supply 24 V 0 V Fieldbus connection RJ-45. Fieldbus connection RJ-45. Configuration and programming interface. Pack. System Data.

MINI MCR-SL-UI-REL(-SP)

CU port USB 2.0 hub. Version: 1.1 Date:

Operating Manual -ENGLISH- Page 1 KWG-ISO

MINI MCR-SL-MUX-V8-FLK 16

DI572 Digital Input Module

MINI MCR-SL-CVS NC

MINI MCR-SL-PT100-UI(-SP)(-NC)

Siemens Industrial s

Mod. TCxP PROFIBUS FIELDBUS MODULE FOR PNEUMATIC MANIFOLD VALVES I/O SIGNAL. Pg. 1 di 23

CU Compact-Flash card adapter for USB. Version: 1.0 Date:

TU531, TU532 Terminal Unit

Transcription:

Fieldbus Independent 8 DI DC 24 V 3.0 ms, 750-436 Manual Version 1.0.1

ii Important Comments Copyright 2006 by WAGO Kontakttechnik GmbH & Co. KG All rights reserved. WAGO Kontakttechnik GmbH & Co. KG Hansastraße 27 D-32423 Minden Phone: +49 (0) 571/8 87 0 Fax: +49 (0) 571/8 87 1 69 E-Mail: info@wago.com Web: http://www.wago.com Technical Support Phone: +49 (0) 571/8 87 5 55 Fax: +49 (0) 571/8 87 85 55 E-Mail: support@wago.com Every conceivable measure has been taken to ensure the correctness and completeness of this documentation. However, as errors can never be fully excluded, we would appreciate any information or ideas at any time. E-Mail: documentation@wago.com We wish to point out that the software and hardware terms as well as the trademarks of companies used and/or mentioned in the present manual are generally trademark or patent protected.

Content iii CONTENT 1 Important Comments...4 1.1 Legal Principles...4 1.1.1 Copyright...4 1.1.2 Personnel Qualification...4 1.1.3 Intended Use...4 1.2 Symbols...5 1.3 Number Notation...5 1.4 Safety Notes...6 1.5 Scope...6 2...7 2.1 Digital Input Modules...7 2.1.1 750-436 [8 DI DC 24 V 3.0 ms, Low-Side Switching]... 7 2.1.1.1 View...7 2.1.1.2 Description...8 2.1.1.3 Display Elements...9 2.1.1.4 Schematic Diagram...9 2.1.1.5 Technical Data...10 2.1.1.6 Process Image...11

4 Copyright View 1 Important Comments 1.1 Legal Principles 1.1.1 Copyright To ensure fast installation and start-up of the units described in this manual, we strongly recommend that the following information and explanations are carefully read and abided by. This manual is copyrighted, together with all figures and illustrations contained therein. Any use of this manual which infringes the copyright provisions stipulated herein, is not permitted. Reproduction, translation and electronic and photo-technical archiving and amendments require the written consent of WAGO Kontakttechnik GmbH & Co. KG. Non-observance will entail the right of claims for damages. WAGO Kontakttechnik GmbH & Co. KG reserves the right to perform modifications allowed by technical progress. In case of grant of a patent or legal protection of utility patents all rights are reserved by WAGO Kontakttechnik GmbH & Co. KG. Products of other manufacturers are always named without referring to patent rights. The existence of such rights can therefore not be ruled out. 1.1.2 Personnel Qualification 1.1.3 Intended Use The use of the product detailed in this manual is exclusively geared to specialists having qualifications in PLC programming, electrical specialists or persons instructed by electrical specialists who are also familiar with the valid standards. WAGO Kontakttechnik GmbH & Co. KG declines all liability resulting from improper action and damage to WAGO products and third party products due to non-observance of the information contained in this manual. For each individual application, the components supplied are to work with a dedicated hardware and software configuration. Modifications are only permitted within the framework of the possibilities documented in the manuals. All other changes to the hardware and/or software and the nonconforming use of the components entail the exclusion of liability on part of WAGO Kontakttechnik GmbH & Co. KG. Please direct any requirements pertaining to a modified and/or new hardware or software configuration directly to WAGO Kontakttechnik GmbH & Co. KG.

Intended Use 5 View 1.2 Symbols Danger Always abide by this information to protect persons from injury. Warning Always abide by this information to prevent damage to the device. Attention Marginal conditions must always be observed to ensure smooth operation. ESD (Electrostatic Discharge) Warning of damage to the components by electrostatic discharge. Observe the precautionary measure for handling components at risk. Note Routines or advice for efficient use of the device and software optimization. More information References on additional literature, manuals, data sheets and INTERNET pages 1.3 Number Notation Number Code Example Note Decimal 100 normal notation Hexadecimal 0x64 C notation Binary '100' '0110.0100' Within ', Nibble separated with dots

6 Intended Use View 1.4 Safety Notes Attention Switch off the system prior to working on bus modules! In the event of deformed contacts, the module in question is to be replaced, as its functionality can no longer be ensured on a long-term basis. The components are not resistant against materials having seeping and insulating properties. Belonging to this group of materials is: e.g. aerosols, silicones, triglycerides (found in some hand creams). If it cannot be ruled out that these materials appear in the component environment, then additional measures are to be taken: - installation of the components into an appropriate enclosure - handling of the components only with clean tools and materials. Attention Cleaning of soiled contacts may only be done with ethyl alcohol and leather cloths. Thereby, the ESD information is to be regarded. Do not use any contact spray. The spray may impair the functioning of the contact area. The and its components are an open system. It must only be assembled in housings, cabinets or in electrical operation rooms. Access must only be given via a key or tool to authorized qualified personnel. The relevant valid and applicable standards and guidelines concerning the installation of switch boxes are to be observed. ESD (Electrostatic Discharge) The modules are equipped with electronic components that may be destroyed by electrostatic discharge. When handling the modules, ensure that the environment (persons, workplace and packing) is well grounded. Avoid touching conductive components, e.g. gold contacts. 1.5 Scope This manual describes the Digital Input Module 750-436 8 DI DC 24 V 3.0 ms, of the modular. Handling, assembly and start-up are described in the manual of the Fieldbus Coupler. Therefore this documentation is valid only in the connection with the appropriate manual.

750-436 [8 DI DC 24 V 3.0 ms, Low-Side Switching] 7 View 2 2.1 Digital Input Modules 2.1.1 750-436 [8 DI DC 24 V 3.0 ms, Low-Side Switching] 2.1.1.1 View 8- Digital Input Module DC 24 V 3.0 ms, 1-conductor connection; low-side switching DI1 DI8 13 14 E1 E2 Data contacts DI 1 DI 2 E3 E4 DI 3 DI 4 E5 E6 DI 5 DI 6 E7 E8 DI 7 Fig. 2.1.1-1: View 750-436 DI 8 Power jumper contacts g043600e

8 750-436 [8 DI DC 24 V 3.0 ms, Low-Side Switching] Description 2.1.1.2 Description The digital input module 750-436 receives control signals from digital field devices (sensors, switches, etc.). The module is a 1-conductor device and has eight input channels. Eight 1-conductor sensors may be directly connected to signal input DI 1,... DI 8. The module is negative switching. This means that the status of the input channels is "high" if the 0V potential is at the input channels. Each input module has an RC noise rejection filter with a time constant of 3.0 ms. All input channels are potential free. The status of the input channels is indicated via status LEDs. An optocoupler is used for electrical isolation between the bus and the field side. Any configuration of the input modules is possible when designing the fieldbus node. Grouping of module types is not necessary. Note The module possesses power jumper contacts to pass through supply voltage for the field side to the following modules. The field side supply voltage of 24 V for the input module is derived from adjacent I/O modules or from a supply module. The supply voltage for the field side is made automatically through the individual I/O modules by means of power jumper contacts. Warning The maximum current of the internal power jumper contacts is 10 A. When configuring the system it is important not to exceed the maximum/sum current. However, if such a case should occur, another supply module must be added. The module can be used with all couplers/controllers of the.

750-436 [8 DI DC 24 V 3.0 ms, Low-Side Switching] 9 Display Elements 2.1.1.3 Display Elements DI1 DI8 13 14 Fig. 2.1.1-2: Display Elements g043002x LED Designation Function green 1 green 2 green 3 green 4 green 5 green 6 green 7 green 8 DI 1 DI 2 DI 3 DI 4 DI 5 DI 6 DI 7 DI 8 off Input DI 1: voltage (0) on Input DI 1: voltage (1) off Input DI 2: voltage (0) on Input DI 2: voltage (1) off Input DI 3: voltage (0) on Input DI 3: voltage (1) off Input DI 4: voltage (0) on Input DI 4: voltage (1) off Input DI 5: voltage (0) on Input DI 5: voltage (1) off Input DI 6: voltage (0) on Input DI 6: voltage (1) off Input DI 7: voltage (0) on Input DI 7: voltage (1) off Input DI 8: voltage (0) on Input DI 8: voltage (1) 2.1.1.4 Schematic Diagram DI 1 1 5 DI 2 DI DI 3 24 V 2 6 DI 4 24 V DI DI 5 0V 3 7 DI 6 0V 10nF 10nF 10nF DI 7 4 750-436 8 DI 8 Fig. 2.1.1-3: Schematic Diagram g043601e

10 750-436 [8 DI DC 24 V 3.0 ms, Low-Side Switching] Technical Data 2.1.1.5 Technical Data Inputs Number of inputs 8 Input voltage voltage (0) -3 V... U V DC (U V - 5 V)... U V voltage (1) DC -3 V... (U V - 15 V) Input current typ. (per channel) Input filter Deceleration time with the transition from 1 to 0 typ. Deceleration time with the transition from 0 to 1 typ. Module Specific Data Power supply Current consumption (internal) max. 2.8 ma 3.0 ms 3.0 ms 4.0 ms via system voltage internal bus (5 V) and power jumper contacts field side power supply (24 V) 13 ma Voltage via power jumper contacts U V DC 24 V (-25 %... +30 %) Isolation Internal bit width Dimensions W x H* x L * from upper edge of 35 DIN rail Weight 500 V (System / Field) 8 bit 12 mm x 64 mm x 100 mm ca. 50 g Standards and Regulations (cf. Chapter 2.2 of the Coupler/Controller Manual) EMC-Immunity to interference (CE) acc. to EN 61000-6-2 (01) EMC-Emission of interference (CE) acc. to EN 61000-6-3 (01) Approvals (cf. Chapter 2.2 of the Coupler/Controller Manual) CUL US (UL508) Conformity Marking More Information Detailed references to the approvals are listed in the document "Overview Approvals ", which You can find on the CD ROM ELECTRONICC Tools and Docs (Item-No.: 0888-0412-0001-0101) or in the Internet under: www.wago.com -> Service /Downloads /Documentation //System Description/.

750-436 [8 DI DC 24 V 3.0 ms, Low-Side Switching] 11 Process Image 2.1.1.6 Process Image Input bit B7 B6 B5 B4 B3 B2 B1 B0 Meaning DI 8 8 DI 7 7 DI 6 6 DI 5 5 DI 4 4 DI 3 3 DI 2 2 DI 1 1

WAGO Kontakttechnik GmbH & Co. KG Postfach 2880 D-32385 Minden Hansastraße 27 D-32423 Minden Phone: 05 71/8 87 0 Fax: 05 71/8 87 1 69 E-Mail: info@wago.com Internet: http://www.wago.com