Passive UTP Transceiver Hub with Integral Camera Power Installation Guide

Similar documents
Active UTP Transceiver Hub with Integral Camera Power Installation Guide

Transceiver Hub with Integral Camera Power

Passive UTP Transceiver Hub with Integral Isolated Camera Power Installation Guide

Active UTP Transceiver Hub with Integral Camera Power Installation Guide

Active UTP Transceiver Hub with Integral Isolated Camera Power Installation Guide

Active UTP Transceiver Hub with Integral Isolated Camera Power

Passive UTP Transceiver Hub Installation Guide

Rack Mount Power Supplies

AL168 Series Multi-Output Power Supplies

PoE Managed Midspan Solution for Standard Network Infrastructure

DC Outdoor Power Supply/Chargers

OWNER S MANUAL SINGLE CAT5E/6 3D EXTENDER B-320-1CAT-HDIR

OWNER S MANUAL SINGLE CAT5E/6 3D EXTENDER B-200-1CAT-HDIR. Receiver

E-ACLM-V E-ACLM-P12/8/18 AC LINE MONITORS Installation and Operation Manual

INSTRUCTION MANUAL DISTRIBUTION UNIT. Please read this manual thoroughly before use, and keep it handy for future reference.

Cantata m100 Amplifier

1 Overview. 2 Specifications. Product Installation Document

CLFE(X)UTP INSTALLATION AND OPERATION MANUAL

CLFE(X)COAX INSTALLATION AND OPERATION MANUAL

VE8012A/VE8012AR DUAL NETWORKED STATION PORT

Installation and Operation Manual CX452 with CHM22/CXM22

HDBaseT EXTENDER B-520-TX-230-IR B-520-TX-330-IR INSTALLATION MANUAL

4K HDR HDBaseT Extender B-560-EXT INSTALLATION MANUAL

Installation Manual. 12 Volt Power Supplies. 18-Port. 9-Port RET18PT RET9PT

TVA2.1 2-Channel Digital Amplifier Installation Manual

Installation Guide. Rev

TOT Series Manual. North American and International Models - without optional faceplate. Receptacle Panel of International Models, CE model shown

Expandable Power Systems

Installation Instructions CX254 Card Cage Power Injector

Passive CCTV Hub Plus (500134) Installation Guide

Owner s Manual. Isolate. Restore. Inspire! Power Conditioners Audio / Video Power Isolation Units Rack Mount / Consumer Series

TOT Series Manual. North American CE and UK Models. CE Models. UK Models. North American Models

MPF-1, Mains Power Filter User Manual

U-150 Integrated Amplifier User s guide

Accessory Packages for the Allegiant

5 B&W Rear View System Camera

Model 160. Model 186. Model 247. Surge Protective Devices. Installation & Operation Manual. Model 160. Model 186. Model 247 (EDCO RM-CX06-16R)

VIP-804 QUAD ENHANCED NETWORK AUDIO PORT

OWNER S MANUAL CD-2 V 1.3

Roth BAR 2LX High-Power Soundbar with Wireless Subwoofer. Turn it up. Roth BAR2 LX Manual UK VJ.indd 1 19/06/ :07

OWNER S MANUAL GEQ 131/ 131LF GEQ 215/ 215LF GEQ 231. Single Channel 31 Band Graphic Equalizer. 2 Channel 15 Band Graphic Equalizer

Basketball Shot Clock Set LX2180 Manual

VMI. Technical Documentation. 600 Industrial Drive, New Bern, N.C (tel / fax /

INSTRUCTION MANUAL. Security Camera. Indoor/Outdoor Color Camera w/ Night Vision. Version 1.0. now you can see. Model# VU5

Neets Switching Relay - 2. Installation manual

ebridge200b - Managed Two Port Transceiver Board

OWNER S MANUAL >> BINARY HD MATRIX SWITCHER B-100-HDMATRIX-4X4 / B-100-HDMATRIX-8X8

HDBaseT EXTENDER B-520-EXT-230-RS-W INSTALLATION MANUAL

iconverter 2-Module Power Chassis

Outdoor Housing PIH-5063/5064/5067 INSTRUCTION MANUAL

This 4200-RM Rack Mount Kit is for installation in 4200-CAB series cabinets only.

Installation RA5112-C-16A-C20. Basic Rack Power Distribution Unit

Installing the Cisco 2524 and Cisco 2525 Routers

ST-C5VRS-600 VIDEO AND RS232 EXTENDER Installation and Operation Manual

Monochrome Camera. Features. User manual

8-Port Ethernet over Fiber PoE Hardened Switches Installation Manual

ITEM NO: SP-001, SP-001P, SP-001VP, SP-001VPD, SP-002, SP-002VP, SP-002VPD, SP-003, SP-004, SP-004VPD, SP-005, SP-006, SP-016C, SP-016T

VIP-812A DUAL NETWORKED STATION PORT

INSTALLATION INSTRUCTIONS FOR THE BV10-100/1000

DVAA Series Disk Array for DVR1 Series Digital Video Recorder

Industrial 1-Port Coax/UTP Long Reach PoE+ 4-Port. 10/100TX PoE Extender LRP-104CET. User s Manual

VE8014A/VE8014AR QUAD NETWORKED STATION PORT

Installation and Operation Manual

4-Port Ethernet over Fiber PoE+ Hardened Switches Installation Guide

Quick Start Guide. C-100 Series Switches

Low Profile Hub. User Manual

Installation/ Operation Manual

AVR Manual. Isolate. Restore. Inspire! Audio / Video Power Isolation Units with Automatic Voltage Regulation. 19 Pro Series Rack Mount (RM) Faceplate

Installing and Configuring Rialto Analytic Appliances

Installation & Operation Guide

DLHD2100 Owners Manual

PS8 - II. Professional Power Sequencer. User s Manual

DRP16 Series. User Guide. DVR Surge Protector & UPS. DITEK Corporation One DITEK Center 1720 Starkey Road Largo, FL

Installation Job Aid for VSP 4850GTS

M-1264 M-1212E STEREO MIXERS. TOA Corporation OPERATING INSTRUCTIONS. TOA 1000 series CAUTION

LBC-H/V-T-WP LINK BRIDGE TM HDMI/VGA WALL PLATE TRANSMITTER SYSTEM

Installation Job Aid for VSP 4450GTX-HT- PWR+

Model 7705 Control Module

Network Power Distribution Module

ETH-4X1-G / 2X1-G / 2X1

3-Port Ethernet over Fiber PoE+ Hardened Switches Installation Guide

Installation Job Aid for Ethernet Routing Switch 3600 Series

7 LCD CCTV Test monitor. Quick guide

Ethernet Test Access Panel (ETAP) User Manual

Roth BAR 2LX High-Power Soundbar with Wireless Subwoofer. Turn it up.

60W Power over Ethernet Waterproof Adapter PoE IEEE BT Single Port Injector for Outdoor Application

Kogan Bluetooth Karaoke System with Dual Microphones KAKAR2MICA

FC-29W 9 UN-UNIVERSAL Dome Housing. Installation Instructions

YST-SW20 SUBWOOFER SYSTEM OWNER S MANUAL. Active Servo Technology

PRIMUX Series. PRIMUX-RDSW PRIMUX Redundancy Switch Installation and Operation Manual

USB-C5 USB-C5-CE USB EXTENDER Installation and User Guide

High Power over Ethernet Midspans PD Port Model PD Port Model

ELECTRO-MECH SCOREBOARD CO.

INSTALLATION INSTRUCTIONS

The power behind competitiveness. Delta Infrasuite Power Management. Power Distribution Unit. User Manual.

16 way 19 1½U enclosure with rear cable management tray NPGZM-16-NJ. ½U high front mounting cable management tray

INSTALLATION MANUAL. HDMI 1x4 Splitter B-230-HDSPLTR-1x4. B-230-HDSPLTR-1x4 HDMI OUT 4 HDMI OUT 3 HDMI OUT 2 HDMI OUT 1 HDMI OUT 4 HDMI IN

Surge Protection for Surveillance Systems

INSTALLATION MANUAL. HDMI 1x8 Splitter B-230-HDSPLTR-1x8 B-230-HDSPLTR-1X8

SW-UNM-24FE2GC-24POE 24 Fast Ethernet Ports PoE + 2 Giga Combo User Manual Ver 1.1

Transcription:

Passive UTP Transceiver Hub with Integral Installation Guide Models Include: HubWay8D HubWay16D - Eight (8) Channels - Sixteen (16) Channels HubWay82D HubWay162D - HubWay8 w/eight (8) HubWayAv - HubWay16 w/sixteen (16) HubWayAv Balun/s for s Balun/s for s HubWay83D HubWay163D - HubWay8 w/eight (8) - HubWay16 w/sixteen (16) Balun/s for 12VDC s Balun/s for 12VDC s Rev. 032108 More than just power. TM

Overview: Altronix HubWay8D/16D Passive UTP Transceiver Hub w/integral transmits UTP video, RS422/RS485 data and power over a single CAT-5 or higher structured cable. Unit provides 8 or 16 camera channels in a space saving 1U EIA 19 rack mount chassis which may be rack, wall or shelf mounted. transmission range is up to 750 ft. max. per channel. Units are compatible with AC and/or DC fixed or PTZ cameras when utilizing Altronix HubWayAv or Balun/s. In addition, the unit features individually selectable or PTC protected outputs with surge suppression. An optional HubSat4D Passive UTP Transceiver Hub with Integral can be used as an accessory module to transmit video from up to 4 cameras over a single CAT-5 or higher structured cable back to the HubWay8D/16D. In addition, the HubSat4D provides power to these cameras locally to eliminate the possibility of voltage drop associated with long cable runs. HubWay8D/82D/83D Input: 115VAC 50/60Hz, 2 amp or 230VAC 50/60Hz, 1.25 amp. Primary fuse (internal) is rated at 5 amp/250v. : Eight (8) channels of video over twisted pair up to a distance of 750 ft. per channel. Eight (8) 75 ohm video outputs. : Unit provides up to 1 amp max. per channel not to exceed a total of 5 amp (150VA) maximum current. : RS422/RS485 data inputs. : Individually selectable or power outputs with position. PTC protected outputs. PTCs are rated @ 1 amp per channel. Surge suppression. Visual Indicators: AC input power indicator. Additional Models: HubWay82D HubWay8D includes eight (8) HubWayAv Balun/s for s. HubWay83D HubWay8D includes eight (8) Balun/s for 12VDC s. HubWay Specifications: Common Specifications: HubWay16D/162D/163D Input: 115VAC 50/60Hz, 4 amp or 230VAC 50/60Hz, 2.5 amp. Primary fuse (internal) is rated at 5 amp/250v. : Sixteen (16) channels of video over twisted pair up to a distance of 750 ft. per channel. Sixteen (16) 75 ohm video outputs. : Unit provides up to 1 amp max. per channel not to exceed a total of 10 amp (300VA) maximum current. Features: Illuminated master power disconnect circuit breaker with manual reset. IEC 320-3-wire grounded line cord (detachable). Unit can be rack, wall or shelf mounted. 1U rack mount chassis for use in standard EIA 19 rack. Accessories: Balun/s: - HubWayAv - for use with cameras. - - for use with 12VDC cameras. Optional HubSat4D allows transmission of up to four (4) video signals over a single CAT-5 or higher structured cable. HubWay162D HubWay16D includes sixteen (16) HubWayAv Balun/s for s. HubWay163D HubWay16D includes sixteen (16) Balun/s for 12VDC s. Installation Instructions: 1. Set the input voltage selector switch located on the left side of the HubWay8D/16D unit (facing front panel) for 115VAC or 230VAC operation (Fig. 1h, pg. 4). 2. Attach mounting brackets to HubWay unit for rack or wall mount installation (Figs. 6-7, pg. 8). Affix rubber pads to HubWay for shelf installation (Fig. 8, pg. 8). 3. Secure the unit in a rack, mount unit to a wall or place unit on a shelf as desired (unit should be spaced at least 3 from any video monitors). 4. Set illuminated master power disconnect circuit breaker to the () position (Fig. 5, pg. 7). - 2 - HubWay Passive Unit

5. Plug the grounded AC line cord (included) into the IEC 320 connector of the HubWay8D/HubWay16D unit (Fig. 1g, pg. 4). Insert the plug end of the line cord into a grounded AC receptacle. 6. Select or power output for Channels 1-8 (Channels 1-16) with the corresponding voltage adjustment switches (Fig. 1d, pg. 4). 7. Connect the BNC video outputs for HubWay8D/16D Channels 1-8 (Channels 1-16) to the corresponding video inputs on the head end equipment (DVR) (Fig. 1f, pg. 4). 8. Connect the RS422/RS485 output of the head end equipment (DVR) to the one (1) or both data input terminal blocks of the HubWay8D or HubWay16D unit (polarity must be observed) (Fig. 1e, pg. 4). Note: The input terminals of the HubWay8D or HubWay16D must be wired in parallel for proper operation. When using fixed cameras disregard this step. 9. Connect Balun/ at camera 1 to the HubWay8D or HubWay16D unit utilizing CAT-5 or higher structured cable. Plug the RJ45 connector at one end of the structured cable into the RJ45 jack marked [Channel 1] of the HubWay8D/16D (Fig. 1a, pg. 4). Plug the RJ45 connector at the opposite end of the structured cable into the RJ45 jack of the Balun/ located at camera 1. For cameras use Altronix model HubWayAv Balun/ (Figs. 2a, 2b, pg. 5). For 12VDC cameras use Altronix model Balun/ (Figs. 2c, 2d, pg. 5). Repeat steps 6-9 for each additional camera (Channels 2-8 or Channels 2-16). Note: When a particular camera exceeds the maximum distance for power transmission, a local external power source is required. Optionally, an Altronix HubSat4D Passive UTP Transceiver Hub with Integral may be utilized (Fig. 4a, pg. 6). The combined total cable distance must not exceed 750 ft. for video transmission between the HubWay8/16 and each camera routed through the HubSat4D. 10. Set illuminated master power disconnect circuit breaker to the RESET (ON) position (Fig. 5, pg. 7) and measure the output voltage at the power output of each Balun/ (Figs. 2b, 2d, pg. 5) before powering each camera to insure proper operation and avoid possible damage. HubWayAv - Terminals marked [AC POWER] (Figs. 2a, 2b, pg. 5). - Terminals marked [ 12VDC +] (Figs. 2c, 2d, pg. 5). 11. Set illuminated master power disconnect circuit breaker to the () position to make the final connections (Fig. 5, pg. 7). 12. Connect the power outputs of the HubWayAv or Balun/s to the power inputs of the cameras (Figs. 2a-2d, pg. 5). Polarity must be observed. 13. Connect the terminals marked [+ DATA --] of the HubWayAv or Balun/s to the data terminals of the cameras for PTZ control (Figs. 2a-2d, pg. 5). Polarity must be observed. When using fixed cameras disregard this step. 14. Connect the BNC connector of the HubWayAv or Balun/s to the BNC video outputs of the cameras (Figs. 2a-2d, pg. 5). 15. Upon completion of wiring set illuminated master power disconnect circuit breaker to the RESET (ON) position (Fig. 5, pg. 7). 16. AC LED (Green) of the HubWayAv or DC LED (Red) of the Balun/s will illuminate indicating power is present at the cameras (Fig. 2b, 2d, pg. 5). 17. The power LEDs (Red) located on the front of the HubWay8D/16D for Channels 1-8 (Channels 1-16) will illuminate when AC power is present (Fig. 1c, pg. 4). If all of the LEDs are there may be a complete loss of supply power to the HubWay unit or the illuminated master power disconnect circuit breaker is in the position. To restore the power output for HubWay8D/16D: The PTC for that particular output is tripped. 1- Switch output voltage switch to the position (Fig. 1d, pg. 4) to reset the PTC allowing approximately 1 minute before switching back to or. 2- Eliminate the trouble condition. 3- Switch output voltage switch back to the or position (Fig. 1d, pg. 4). HubWay Passiive Unit - 3 -

Fig. 1 1e - : Removable terminal blocks for RS422/ RS485 input from head end 1b - Channels 1-4, Channels 5-8, Channels 9-12 & Channels 13-16: equipment (DVR) for PTZ control. CAT-5 or higher structured cable from optional HubSat4S enables video transmission from up to four (4) cameras. Top View input from Head End Equipment (DVR). + -- 1d - Output voltage switches: Selects // for each output. 1c - LED(s) 1-16: indicators. 1a - Channels 1-8 (HubWay8D) or Channels 1-16 (HubWay16D): CAT-5 or higher structured cable to /Balun s at cameras 1-8 or 1-16. When using the optional HubSat4D any of the outputs can be utilized for the data transmission from the HubSat4D. RESET 13 14 15 16 CH 13-16 1 2 3 4 CH 1-4 5 6 7 8 CH 5-8 9 10 11 12 CH 9-12 + DATA - 9-16 + DATA - 1-8 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 AC POWER 1g - IEC 320 Connector: 115VAC/230VAC 50/60Hz (grounded line cord included). 1f - BNC Connector: outputs to head end equipment (DVR). 115VAC 220VAC 1h - Input Voltage Switch: Selects 115VAC/230VAC 50/60Hz (switch is located on the left side of the unit). - 4 - HubWay Passive Unit

Altronix Model Number Fig. 2 HubWayAv and Balun/s: Input Voltage from HubWay unit Output Voltage to camera HubWayAv */ */ cameras Green */ 12VDC 12VDC cameras Red *Based on camera load and structured cable length. Type LED Fig. 2a VIDEO Fig. 2c VIDEO HubWayAv VIDEO BALUN/COMBINER VIDEO BALUN/COMBINER CAT5 AC + DATA-- POWER CAT5 + DATA-- -- 12VDC+ RJ45 Jack Wire Connectors RJ45 Jack Wire Connectors Fig. 2b Fig. 2d To BNC Connector of Structured Cable from HubWay8D or HubWay16D Green LED AC to -- to + To BNC Connector of Structured Cable from HubWay8D or HubWay16D Red LED + 12VDC -- to -- to + HubWayAv passes AC voltage from pins 4, 5, 7, 8 to terminals marked [AC ] (Fig. 3, pg. 5). converts AC voltage to DC voltage from pins 4, 5, 7, 8 to terminals marked [--12VDC +] (Fig. 3, pg. 5). Fig. 3 - CAT-5 Structured Cable Wiring Color Codes and PIN Configurations 1 - White/Orange [VIDEO +] 2 - Orange [VIDEO -- ] 3 - White/Green [DATA +] 4 - Blue [AC 1] 5 - White/Blue [AC 2] 6 - Green [DATA -- ] 7 - White/Brown [AC 2] 8 - Brown [AC 1] HubWay Passiive Unit - 5 -

Typical Applications: Fig. 4 Head End Equipment (DVR) RS485 Monitor Rear 8 7 6 5 4 3 2 1 AC POWER 1 2 3 4 CH 1-4 5 6 7 8 CH 5-8 + DATA - 1-8 Front CAT-5 CAT-5 Four (4) signals on a single CAT-5 (CAT-5) CAT-5 Max. video 750 ft. Fixed HubWayAv Balun Fixed Balun PTZ Balun HubWayAv Balun PTZ PTZ HubWayAv Balun Outdoor PTZ Outdoor NEMA Rated Supply HubWayAv or Balun Fixed CAT-5 Balun / Provided by HubSat4D 115VAC Input, 50/60Hz Fig. 4a - Optional hookup utilizing HubSat4D. (Coax) Fixed 115VAC Input, 50/60Hz - 6 - HubWay Passive Unit

1U EIA 19 Rack Mount Chassis Mechanical Drawing & Dimensions: 1.625 H x 19.125 W x 8.5 D REAR 1.625" 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 AC POWER TOP & BOTTOM 17.625" 8.5" FRONT 1 2 3 4 CH 1-4 CH 5-8 5 6 7 8 9 10 11 12 CH 9-12 13 14 15 16 CH 13-16 + DATA -- 1-8 + DATA -- 9-16 19.125".75" (ON) Fig. 5 Illuminated master power disconnect circuit breaker: position Circuit breaker tripped Switch not illuminated. RESET (ON) position Switch illuminated. The lightning flash with arrow head symbol within an equilateral triangle is intended to alert the user to the presence of an insulated DANGEROUS VOLTAGE within the products enclosure that may be of sufficient magnitude to constitute an electric shock. The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the appliance. CAUTION: To reduce the risk of electric shock do not open enclosure. There are no user serviceable parts inside. Refer servicing to qualified service personnel. HubWay Passiive Unit - 7 -

Mounting Options: Rack Mount Installation 1- Remove and discard factory installed screws from both sides of rack chassis (Fig. 6a). 2- Install mounting brackets (A) on the left and right side of rack chassis using the four (4) flat head screws (B) (included) (Fig. 6b). 3- Place unit into desired EIA 19 rack position and secure with mounting screws (not included) (Fig. 6c). Fig. 6 Fig. 6a Fig. 6b Fig. 6c Top Top Top Front Left B Front Left Front Left Remove A Wall Mount Installation 1- Install mounting brackets (A) on the left and right side of rack chassis using four (4) flat head screws (B) (included) (Fig. 7a). 2- Place unit at desired location and secure with mounting screws (not included) (Fig. 7b). Fig. 7 Caution: It is necessary to Fig. 7a Fig. 7b make sure mounting screws are securely fastened to a beam when installing the unit vertically. B A Dotted lines indicate studs behind sheetrock. Shelf Installation 1- Position and affix rubber pads (C) (included) at each corner on the bottom of the unit (Fig. 8). 2- Place unit in desired location. Fig. 8 Altronix is not responsible for any typographical errors. C Left Side Rubber Pad Mounting Hardware (Included): A B C Two (2) mounting brackets Six (6) flat head screws for mounting brackets. Four (4) rubber pads. 140 58th Street, Brooklyn, New York 11220 USA, 718-567-8181, fax: 718-567-9056 website: www.altronix.com, e-mail: info@altronix.com, Lifetime Warranty, Made in U.S.A. IIHubWay8D/HubWay16D I11H MEMBER - 8 - HubWay Passive Unit