Model 3750 Multifunction I/O Card

Similar documents
Model 3724 Dual 1x30 FET Multiplexer Card

Model 7705 Control Module

Series 3700 Screw Terminal Assemblies Installation Instructions

High Density Switch Mainframe and Cards

Series Watt DC Power Supplies

CVU-200-KIT. 200 V Bias Tee Kit. Description. Parts list / October 2014 *P A* 1

CVU-3K-KIT. 3 kv Bias Tee Kit. Description. Parts list / October 2014 *P * 1

IDEAL INDUSTRIES INC. TECHNICAL MANUAL MODEL:

User safety and equipment protection guidelines

Installation Instructions

USB-201-OEM. Analog and Digital I/O. User's Guide

Model 3706A Systems Switch/Multimeter Specifications SPEC-3706A Rev. C / June 2018 Page 1 of 6. Input Resistance or Open Circuit Voltage 2

This 4200-RM Rack Mount Kit is for installation in 4200-CAB series cabinets only.

Model Channel TTL I/O

LGR-5325 Specifications

Specifications USB-1616HS

Model 2440 Service Manual Rev. B / December 2004

Model Channel High Voltage Multiplexer Card

Installation Instructions

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL:

Model 2600B-PM V Protection Module with 1 A Clamp. Description / April 2015 *PPA * 1

High Voltage Power Supplies

Model 8020-KHV. Kelvin Keithley Triaxial Connector Card. Description / October 2014 *P * 1

P2-04DA Analog Output. Removable Terminal Block Specifications

Model 4200-CVU-PWR. Parts Package. Introduction. PA-977 Rev. C / September 2016 *PPA-977C* 1

Model 2657A-LIM-3 LO Interconnect Module

2260B-RMK-Series Rack Mount Kit

USB-201. Analog and Digital I/O. User's Guide. January Rev 7 Measurement Computing Corporation

V E2B Snap-in I/O Module

Model 2460-KIT. Screw Terminal Connector Kit. Description / September 2014 *P * 1

Autoranging True RMS Multimeter User Manual

Model 8020-STC. Kelvin Standard Triaxial Connector Card. Description / October 2014 *P * 1

Model 7026 (1x32) 2-wire Multiplexer

P2-04DAL-2 Analog Output. Removable Terminal Block Specifications

NUV300 Datasheet. Nuvation BMS Low-Voltage Battery Controller , Rev Copyright 2018, Nuvation Energy

LGR-5327 Specifications

USB-2527 Specifications

P2-04AD Analog Input. Removable Terminal Block Specifications

Automation Interface Requirements for System I/O Interface of a DPC I Welding System

V E1B Snap-in I/O Module

Model 707B / 708B Switching Matrix Mainframe Specifications Model 707B Six Slots with Fixed Rack Model 708B Single Slot with Fixed Rack

Installation Instructions

Model 7700 Multiplexer Module

Installation Instructions

USB 1608G Series USB Multifunction Devices

Chapter 1 Introducing the OM-USB Functional block diagram... 5

NI PXI-2567 Specifications

General Specifications. P2-8AD4DA-2 Analog Input/Output

HV-CS kv Edge Mount Triaxial Jack

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions

DM-918 OPERATIONS MANUAL AUTORANGING MULTIMETER

ACTIONI/Q Q498. DC Powered DC Input Field Configurable Isolator with Math Functions

Low Cost Multifunction I/O 100 ks/s, 12-Bit, 8 Analog Inputs

Temperature. Model 3706A Multimeter / Switch System SPEC-3706A Rev. B / February 2014 Page 1 of 6

Model 2380 Rack-Mount Kit

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS:

V E5B Snap-in I/O Module

E Series Multifunction I/O 1.25 MS/s, 12-Bit, 16 or 64 Analog Inputs

DBK48. Multipurpose Isolated Signal-Conditioning Module. Description. Supports up to Sixteen 8B Modules

Model 8010 High Power Device Test Fixture Interconnection Reference Guide

Errata. Agilent References in this manual. About this manual. Support for your product

General Specifications. P2-08THM Analog Input

Installation Instructions

A 40-pin connector provides access to 24 DIO connections.

User Guide CPSMP VAC Power Supply Module: PointSystem CPSMC Accessory CPSMC Accessory. Contents.

Model 2450 Interactive SourceMeter Instrument

V E1B Snap-in I/O Module

Series 8000 RF Signal Switch Solution

Model 2700 Multimeter/Data Acquisition System Service Manual

CheckSum. FUNC-2B Functional Test Module. The FUNC-2B features:

Model GHz 50 Ohm RF Module

RAD-DI8-IFS. I/O extension module with 8 digital inputs or 2 pulse inputs. INTERFACE Data sheet. 1 Description

Chapter 1 Introducing the OM-USB-1608G Series...6 Functional block diagram...7

USB 1608G Series USB Multifunction Devices

Chapter 1 Introducing the OM-USB-1608FS-Plus... 6 Functional block diagram... 6

Installation Instructions

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

ADDJOG User Guide 7/30/10. Overview

IO-DI8-RO8, IO-DI8-RO8-L I/O Expansion Modules 8 Inputs, 8 Outputs

Model SPDT Switch Module

PCI-DIO. PCI Isolated Digital Input/Output Card. User Manual

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description

PC-CARD-DAS16/12 Specifications

Model 7701 Multiplexer Module

USER S MANUAL VER.1. C10D- PARALLEL PORT INTERFACE CARD BOARD Rev. 1

IO-DI8-TO8 I/O Expansion Module 8 Inputs, 8 Outputs

A variety of ECONseries modules provide economical yet flexible solutions. Waveform Generation

Model 2380 Rack-Mount Kit

Specifications

360W and 720W Programmable DC Power Supplies

Model 500 Series Laser Diode Driver User's Manual

REDUNDANCY MODULE TSP-REM360 AND TSP-REM600

Models 2601B, 2602B, and 2604B System SourceMeter Instruments Quick Start Guide

BMX DDM Mixed Relay Input/Output module

WARNING: Do not use the thermometer/data logger before you read the users manual and the following instructions.

V E62B Snap-in I/O Module

Model 2010 Multimeter Service Manual Rev. D / October 2003

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL:

CPCI - 6U - AC - 600W

PC-CARD-DAS16/16 Specifications

Transcription:

Keithley Instruments, Inc. 28775 Aurora Road Cleveland, Ohio 44139 1-888-KEITHLEY www.keithley.com Model 3750 Multifunction I/O Card Connection Instructions and Specifications Introduction This instruction sheet contains information about the Keithley Instruments Model Series 3700 Multifunction I/O Card connector pins, safety precautions, and product specifications. WARNING The following information is intended for qualified service personnel. Do not make module connections unless qualified to do so. To prevent electric shock that could result in serious injury or death, adhere to the following safety precautions: Before removing or installing a switch module in the mainframe, make sure the mainframe is turned off and disconnected from line power. Before making or breaking connections, make sure the power is removed from all external circuitry. Do not connect signals that may exceed the maximum specifications of the model or external wiring. Specifications for each circuit board are provided in the Series 3700 User's Manual. WARNING All wiring must be rated for the maximum voltage in the system. For example, if 300V is applied to the backplane connector, all module wiring must be rated for 300V. Information related to reading, writing, and controlling channels, as well as scanning, can be found in the Series 3700 System Switch/Multimeter User s Manual. Detailed information about controlling the Series 3700 from a remote interface can be found in the Series 3700 System Switch/Multimeter Reference Manual. PA-981 Rev. A / July 2008 1

Model 3750 Multifunction I/O Card The Model 3750 Multifunction I/O Card has 40 bidirectional digital I/O bits arranged in five banks of eight bits each. Each bank can be configured as either inputs or outputs. One bank of I/O is equivalent to one system channel. The two analog outputs of the Model 3750 can be individually configured as either voltage outputs (+/- 12 V) or as current outputs (0 ma to 20 ma or 4 ma to 20 ma). Four 32-bit counters are provided with a maximum input range of 1 MHz. Each counter has a gate input for control of event counting. Figure 1: Model 3750 Multifunction I/O Card 2 PA-981 Rev. A / July 2008

Connection information: Model 3750 Figure 2: Model 3750 connection information PA-981 Rev. A / July 2008 3

Specifications GENERAL Channels 1-5: Bidirectional, high current digital I/O (40 bits) Channels 6-9: 32-bit counter (4 counters) Channels 10-11: Isolated voltage and current analog outputs (2 each) DIGITAL I/O 1 Configuration: 40 bidirectional digital I/O bits arranged in 5 banks of 8 bits each. Each bank can be configured for either input or output capability. 1 bank of I/O is equivalent to 1 system channel. Digital Input specifications: An internal weak pull-up resistor of approximately 68 kω is provided on the card for each I/O. This pull-up resistor can be removed via onboard jumper on a channel (8 bit) basis. The pull-up voltage can either connect to the internally supplied 5V or an externally supplied voltage of up to 30V via onboard jumper. An internal 5V supply connection is separately available to run external logic circuits. Digital Input logic low voltage: 0.8V max Digital Input logic high voltage: 2V min. Digital Input logic low current: -600uA max @ 0V Digital Input logic high current: 50uA max @ 5V Logic: Positive True. System Input Minimum Read speed 2 : 1000 readings / second. Maximum externally supplied pull-up voltage: 30V 1 All channels power up configured as inputs. 2 All channels configured as inputs. 4 PA-981 Rev. A / July 2008

Maximum externally supplied voltage to any digital I/O line: Pull-up voltage (5V internal or up to 30V external) Digital Output specifications: Each output has an internal fly-back diode for driving inductive loads. Each output is protected against continuous short circuits and over temperature. An internal 5V supply connection is separately available to run external logic circuits. Digital Output logic high voltage: 2.4V minimum @ Iout = 10mA. sourcing only. Digital Output logic low voltage: 0.5V maximum @ Iout = -300mA sinking only. Maximum output sink current: 300mA per output, 3.0 A total per card. Logic: Positive True. System Output Minimum Write speed 3 : 1000 readings / second. Maximum externally supplied voltage to any digital I/O line: Pull-up voltage (5V internal or up to 30V external) Alarm: Trigger generation is supported for a maskable pattern match or state change on any of channels 1 through 5. Protection: Optional disconnect (set to inputs) during output fault conditions. Internal 5V logic supply: The internal logic supply is designed for powering external logic circuits of up to 50mA maximum. The logic supply is internally protected with a self-resetting fuse. Fuse reset time < 1 hour. 3 All channels configured as outputs. PA-981 Rev. A / July 2008 5

COUNTER / TOTALIZER INPUT Maximum Count: 2 32-1 Maximum Input Rate: 1 MHz, rising or falling edge, programmable. Minimum Input pulse width: 500 ns Input Signal Level: 200 mvp-p (minimum), 42V Peak (maximum) Threshold: AC (0V) or TTL Logic Level Gate Input: TTL-HI (Gate+), TTL-LO (Gate-) or NONE. Minimum Gate input setup time: 1us Count Reset: Manual or Read + Reset System Input Minimum Read speed: 1000 readings / second. Alarm: Trigger generation is supported for a count match or counter overflow on any of channels 6 though 9 ANALOG VOLTAGE OUTPUT The isolated analog voltage output is designed for general purpose, low power applications. Output Amplitude 4 ± 12V up to 10mA Overload Current: 21mA minimum. Resolution: 1mV. Full Scale Settling Time 5 : 1ms to 0.1% of output. DC Accuracy 6 : ± (% of output + mv) 1 year 23 ± 5 C: 0.15% + 16mV 90 day 23 ± 5 C: 0.1% + 16mV 24 hour 23 ± 5 C: 0.04% + 16mV Temperature Coefficient: ± (0.02% + 1.2mV) / C 10mV Maximum Update Rate: 350us to 1% accuracy. System limited. Output Fault Detection: System fault detection is available for short circuit output / current compliance. Isolation: 300 V Peak Channel to Channel or Channel to Chassis. Protection: Optional disconnect during output fault conditions. 4 Programming up to 1% over full scale range is supported 5 Measured with standard load shown in Figure 1 6 Measured with > 10MΩ input DMM (DCV, filter, 1 PLC rate). Warm-up time is 1 hour @ 10mA load with 3750-ST 6 PA-981 Rev. A / July 2008

Maximum guaranteed stable capacitive load: 10 nf ANALOG CURRENT OUTPUT The isolated analog current output is designed for 0-20 ma or 4-20 ma unipolar modes of operation. Output Amplitude: 0 to 20mA or 4 to 20mA Compliance Voltage: 11V minimum. Maximum Open Circuit Voltage: 16V Resolution: 1 ua. Full Scale Settling Time 5 : 1ms to 0.1% of output. DC Accuracy 7 : ± (% of output + ua) 1 year 23 ± 5 C: 0.15% + 18uA 90 day 23 ± 5 C: 0.1% + 18uA 24 hour 23 ± 5 C: 0.04% + 18uA Temperature Coefficient: ± (0.02% + 1.6uA) / C Output Fault Detection: System fault detection is available for open circuit output / voltage compliance. Isolation: 300 V Peak Channel to Channel or Channel to Chassis. Protection: Optional disconnect during output fault conditions. CONNECTOR TYPE: Two 50 pin male D-shells. OPERATING ENVIRONMENT: Specified for 0ºC to 50ºC. Specified to 70% R.H. at 35ºC STORAGE ENVIRONMENT: -25ºC to 65ºC WEIGHT: 1.27 kg (2.80 lb) FIRMWARE: Requires main revision to be 1.20 or above (Applies to all 3706 series mainframes) SAFETY: Conforms to European Union Directive 73/23/EEC, EN61010-1 EMC: Conforms to European Union Directive 2004/108/EC, EN61326-1 Power Budget Information: Quiescent Power: 3300 mw Digital Outputs each channel (1 through 5): 325 mw Analog Channel each (10 & 11): 820 mw 7 Measured with < 2Ω shunt DMM (DCI, filter, 1 PLC rate). Warm-up time is 1 hour with 3750-ST PA-981 Rev. A / July 2008 7

Totalizer Channel all (6 through 9): 730 mw Analog channels and counter channels may optionally be turned off to conserve system power. See Chapter 8 of the series 3700 user s manual for more detailed information. ACCESSORIES AVAILABLE: 3750-ST screw terminal block 3790-KIT50-R 50 pin female D-sub connector kit (contains 2 female D-sub connectors and 100 solder-cups) 3721-MTC-3 50 pin D-sub female to male cable, 3m 3721-MTC-1.5 50 pin D-sub female to male cable, 1.5m 8 PA-981 Rev. A / July 2008