Original operating instructions. Fail-safe SmartPLC with Profinet slave interface AC402S /00 06/2016

Similar documents
Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

Operating instructions. Switching amplifier DN0210 DN / / 2015

Operating instructions RFID evaluation unit DTE / / 2016

Operating instructions. Speed monitor D / / 2014

Operating instructions IO-Link master CabinetLine AL19xx

Operating instructions. Standstill monitor A / / 2011

Original operating instructions Fail-safe inductive sensor GF711S / / 2013

Original operating instructions Fail-safe inductive sensor GI711S / / 2010

Original operating instructions Fail-safe inductive sensor GI712S

Original operating instructions Fail-safe inductive sensor GG711S

Original operating instructions Safety relay with relay outputs G1501S / / 2016

Original operating instructions Safety relay with relay outputs with and without delay G1502S / / 2016

Operating instructions Diagnostic electronics for vibration sensors VSE002 / VXE002 / VXE003 VYE001 / VYE002 / VYE003 / VYE /01 05/2015

Installation instructions Ethernet switch EC / / 2011

System manual AS-i safety monitor AC041S /00 05/2013

Original operating instructions Photoelectric safety sensors (safety light grid) with active / passive system OY90xS

Operating instructions Evaluation system for flow sensors VS / / 2013

Operating instructions. Monitor FD / / 2013

Operating instructions Optical distance sensor. OID20x / / 2014

Operating instructions Optical distance sensor. OID25x / / 2015

Operating instructions Optical distance sensor. OID25x / / 2014

Installation instructions RF-identification system with integrated AS-i slave DTSLF / / 2010

Operating instructions. Monitor FS-2 / FS-2N / / 2013

Operating instructions Optical distance sensor. OID20x / / 2015

Installation instructions Diagnostic electronics for vibration sensors VSE / / 2007

Operating instructions AC010S Compact AS-i E-STOP safety module

AS-i 3.0 Gateways, PROFIsafe via PROFIBUS or PROFINET

AS-i 3.0 Gateways, PROFIsafe via PROFIBUS or PROFINET

Installation instructions Inclination sensor EC2019 EC / / 2013

Operating instructions. Monitor FR-1 / FR-1N / / 2013

Fieldgate SFG500. Technical Information. Intelligent Ethernet/PROFIBUS gateway

AS-i 3.0 EtherNet/IP + Modbus TCP-Gateways with integrated Safety Monitor

AS-i 3.0 Gateways, PROFIsafe via PROFIBUS or PROFINET

AS-i 3.0 Sercos Gateways with integrated Safety Monitor

AS-i Safety Relay Output Module with Diagnostic Slave

AS-i 3.0 PROFINET-Gateways with integrated Safety Monitor

AS-i 3.0 PROFIBUS Gateways with integrated Safety Monitor

Operating instructions Optical distance sensor. O5D15x / / 2014

AS-i Safety Relay Output Module with Diagnostic Slave

Content. Sontheim Industrie Elektronik GmbH Page 2 of 15 07/2016 Installation instructions Version 1.2

AS-i 3.0 EtherNet/IP + Modbus TCP-Gateways with integrated Safety Monitor

Quick reference guide 3D sensor O3D3xx

AS-i Safety Relay Output Module with Diagnostic Slave and 1 EDM Input

AS-i 3.0 PROFIBUS Gateways with integrated Safety Monitor

AS-i 3.0 PROFIBUS Gateways with integrated Safety Monitor

User Manual Gateway component for EtherNet/IP

Operating instructions ClassicLine module AC5203 / AC5205 AC5208 / AC5211 AC5213 / AC5214 AC5215 / AC5233 AC /00 02/2015

Operating instructions. Monitor FS-1 / FS-1N / / 2013

User's Manual. english

MANUAL VAA-2E2A-G12-SAJ/EA2L Original Instructions Version 1.0

Operating instructions Safe AS-i input module ASIM-C-M About this document. Content

QXA2000 QXA2001. Condensation Monitor QXA2001 QXA2000 AQX2000

XPSMCMx Fieldbus Expansion Modules Instruction Sheet (Original Language)

Technical Information Fieldgate SFG500

PSR-MS60. Safety relay for emergency stop, safety door and light grid monitoring. Data sheet. 1 Description

Operating Manual FPGA-based High-Speed Micro-PLC

Operating instructions Monitor FD-2 DR2005 DR / / 2007

TM241CEC24R controller M IO relay Ethernet CAN master

AS-i 3.0 Gateways, PROFIsafe via PROFIBUS or PROFINET

Operating instructions RFID evaluation unit DTE / / 2011

AS-i 3.0 EtherCAT Gateways with integrated Safety Monitor

AS-i 3.0 Gateways, PROFIsafe via PROFIBUS or PROFINET

TM241CE24T controller M IO transistor PNP Ethernet

TM241CE40R controller M IO relay Ethernet

Operating Manual UMB ISO Converter ISOCON Order Number: 8160.UISO

TM241CE40T controller M IO transistor PNP Ethernet

TM241CE24T controller M IO transistor PNP Ethernet

Article no. BWU2045: AS-i Safety Relay Output Module with Diagnostic Slave and 1 EDM Input 1.23 NC

PSR-PC50. SIL 3 coupling relay for safety-related switch on. Data sheet. 1 Description

TM241CE40R controller M IO relay Ethernet

PSR-SCP- 24DC/SSM/2X1 PSR-SPP- 24DC/SSM/2X1

ATV930U30M3 variable speed drive - ATV930-3kW - 200/240Vwith braking unit - IP21

Supplementary device manual EtherCAT interface in the AS-i controllere A AC1391 AC1392

Original Programming Manual Fail-safe SmartPLC AC4S with fieldbus interfaces AC402S AC422S

Device manual Diagnostic electronics with PROFINET-IO interface for vibration sensors VSE150

Motor controllers CMMO-ST

TM241CE40R controller M IO relay Ethernet

Controller CMXH-ST2 Key features

BACnet/IP Web Interface

MC 11 EB-2 Power supply cabinet with external bus, AC version

Operating instructions (short version) Safety monitor AS-Interface Safety at Work ASM E1-R2 ASM E2-R2/R2. 1. About this document.

Part No. Description Product Life Cycle Phase *) unit, 24 VDC, spring terminals. unit, 24 VDC, spring terminals, XC version

XPSMF35. Product data sheet Characteristics. Preventa safety PLC compact - Profibus DP protocol. Main. Complementary. Safety module name

TM251MESC controller M251 Ethernet CAN

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

Modular controllers CECX

D6030S - D6030D INSTRUCTION MANUAL. D SIL 3 Switch/Proximity Detector Repeater Relay Output. Models D6030S, D6030D

Operating instructions Memory plug E /02 11/2011

Operating instructions for AX5801. TwinSAFE drive option card for the AX5000 servo drive. Version: Date:

XPSMCMCO0000EM Modbus TCPIP diagnostic expansion module with screw term

TM241CE24T controller M IO transistor PNP Ethernet

TM241C24T controller M IO transistor PNP

NX integrated safety System configuration. Integrated safety into machine automation

Assembly and Operating Instructions. M2 module for BDC-i440 control units

TM251MESC controller M251 Ethernet CAN

Drive Technology \ Drive Automation \ System Integration \ Services. Manual. Control Cabinet Inverter MOVITRAC B Functional Safety

General information Engineering with Programming package. Display with display. Supply voltage 24 V DC Yes. Input current

General information Engineering with Programming package. Display with display

Operating instructions Safety-monitoring module SE-304 C. 1. About this document. Content

TM241CE24U controller M IO transistor NPN Ethernet

Transcription:

Original operating instructions Fail-safe SmartPLC with Profinet slave interface AC402S UK 80237419/00 06/2016

Contents 1 Preliminary note...4 1.1 Notes on this document...4 1.2 Symbols used...4 2 Safety instructions...4 2.1 General...4 3 Items supplied...5 4 Functions and features...6 4.1 Electrical voltage supply...6 4.2 Configuration interface...6 4.3 AS-i interfaces...6 4.4 Local safe inputs and outputs...6 4.5 Fieldbus interface...7 5 Installation...7 6 Operating, connection and display elements...8 6.1 Operating and connection elements...8 6.2 LED indicators...9 6.2.1 Device LED H1...9 6.2.2 Profinet LEDs H2 and H4...9 6.2.3 Profinet LEDs H3 and H5...9 7 Electrical connection...9 7.1 Wiring...9 7.2 Connect the supply voltage...10 7.2.1 Standard configuration: 24 V power supply and AS-i power supply/ supplies...10 7.2.2 Device supply via a joint power supply.... 11 7.3 Connect sensors / actuators...12 8 Operation...13 8.1 Notes on the EMC-compliant operation...13 8.2 Settings...13 8.2.1 Language selection...13 8.3 Navigation...14 8.3.1 Navigation elements...14 8.3.2 Pictograms and main navigation...15 2

8.3.3 OSC (Online Support Center)...16 9 Diagnostics...17 10 Maintenance, repair and disposal...17 11 Approvals / tests...17 12 Additional documents...17 13 Technical data...18 13.1 Safety classification...19 14 Scale drawing...20uk 3

1 Preliminary note 1.1 Notes on this document This document applies to devices of the type "Fail-safe SmartPLC with Profinet slave interface" (art. no.: AC402S). It is part of the device and contains information about the correct handling of the product. This document is intended for qualified electricians. These specialists are people who are qualified by their training and their experience to see and to avoid possible hazards that may be caused during operation of the device. Installation and set-up must be carried out by staff qualified in functional safety. Read this document before using the device. Keep this document during the service life of the device. 1.2 Symbols used Instructions > Reaction, result [ ] Designation of keys, buttons or indications Cross-reference Important note Non-compliance may result in malfunction or interference. Information Supplementary note 2 Safety instructions 2.1 General Observe these operating instructions. Adhere to the warning notes on the product. In case of non-observance of notes or standards, especially when tampering with and/or modifying the unit, any liability and warranty is excluded. The safe operation of the device is only ensured when the specified requirements are complied with. The applicable technical standards for the corresponding application must be complied with. For installation, the requirements according to EN 60204 must be observed. 4

In case of malfunction of the device contact the manufacturer. Tampering with the unit is not allowed. Do not insert any objects into the device. Prevent metal foreign bodies from penetrating. After installation of the system perform a complete function check. Only use the unit under the specified operating conditions ( Technical data). In case of special operating conditions please contact the manufacturer. Use of the unit in the vicinity of chemical and biological media as well as ionising radiation is not permitted. In case of any questions please contact the safety authorities in your own country. UK WARNING In case of improper handling of the product, the safety and physical integrity of persons and machinery cannot be guaranteed. Death or serious irreversible injuries may result. Note all remarks on installation and handling given in these instructions. The device must only be used under the specified operating conditions and in accordance with use as prescribed below. 3 Items supplied 1 fail-safe SmartPLC AC402S 3 Combicon connection terminals 1 original operating instructions AC402S 1 EU declaration of conformity Service address list with ifm contacts If one of the above-mentioned components is missing or damaged, please contact one of the ifm branch offices. Device manual and programming manual are not supplied. These are available at www.ifm.com. 5

4 Functions and features The fail-safe SmartPLC AC402S integrates two AS-i masters, a safe PLC, a nonsafe PLC, a WEB server and a Profinet slave interface with 2-port switch. It controls the exchange of data to the sensor / actuator level. It can be used as a safe and a non-safe controller (PLC). It communicates with the higher-level control level via Profinet. It visualises sensor/actuator data on the integrated WEB server. It allows device configuration via the WEB server. 4.1 Electrical voltage supply Device supply from 24 V (AUX) 4.2 Configuration interface RJ45, twisted pair (10 Mbps and 100 Mbps) TCP/IP - Transport Control Protocol / Internet Protocol UDP/IP - User Datagram Protocol EtherCAT (master) Modbus TCP (master/slave) 3S network-global variables HTTP server CODESYS programming interface Secure network variables OPC UA CODESYS Web visualisation 4.3 AS-i interfaces 2 AS-i masters AS-i Power24 compatible Ground-fault detection 4.4 Local safe inputs and outputs In the following they are called Safe-IO. 8 connection terminals for 6

-- up to 4 safe inputs according to SIL3 / PL e / category 4 -- up to 8 non-safe inputs Use safe inputs always with two channels. 4 connection terminals for -- up to 2 safe semiconductor outputs according to SIL3 / PL e / category 4 -- up to 4 non-safe outputs 4.5 Fieldbus interface Profinet RT device class B 100 Mbps UK 5 Installation The device must only be installed, connected and put into operation by a qualified electrician as the safe function of the device and machinery is only guaranteed when installation is correctly carried out. The installation and connection must comply with the applicable national and international standards. Responsibility lies with the person installing the unit. Fix the device onto a 35 mm raised rail. Vertical installation (upright). Adhere to a minimum distance of 30 mm between the ventilation holes (perforated sheet) and other parts. Maximum operating altitude: 2000 m above sea level The protection rating of the device is IP 20. The installation must take place in a control cabinet with at least IP 54 protection. Lay the cables in a cable duct. Keep the installation space of the device free from electrically-conductive particles. Ensure a condensation-free environment. Avoid excessive dust, vibration and shock. The air circulation through the vents must not be impeded. Avoid installation in direct vicinity of frequency inverters or other interfering sources. 7

6 Operating, connection and display elements 6.1 Operating and connection elements 13 12 11 0 1: Device LED H1 green / yellow / red 2: Softkeys 3: Navigation buttons 4: AS-i bus und FE connection X1 5: 24V device voltage supply X2 6: Connection for 24V Safe-IO voltage supply and local inputs/outputs X4 7: Front flap 8: Slot for SD card 9: Configuration interface X3 (RJ45) 10: Profinet interface 1 X7 (RJ45) 11: Device LED H4 / H5 12: Profinet interface 2 X6 (RJ45) 13: Device LED H2 / H3 8

6.2 LED indicators 6.2.1 Device LED H1 The LED on the front panel signals the state of the device and the connected systems. LED status Description Green LED lit: > > Device has been started. > > There is no warning message. > > There is no error message Yellow LED flashes slowly (0.5 Hz): > > There is a warning message. > > There is no error message. Red LED flashes quickly (2 Hz): > > There is an error message. UK 6.2.2 Profinet LEDs H2 and H4 LED status Description Yellow LED flashing: > > Reception of data 6.2.3 Profinet LEDs H3 and H5 LED status Description Green LED lit: > > Physical connection OK 7 Electrical connection The unit must be connected by a qualified electrician. Disconnect the plant from the mains supply before installation. Observe the national and international regulations for the installation of electrical equipment. Connect the device as indicated on the terminals. Ensure an electrical connection between the fail-safe SmartPLC AC402S (X1, terminal X1, pin 5 FE) and the ground of the installation. 7.1 Wiring Terminal X1 Pin Description 9

AS-i 2 + 1 AS-i + for AS-i line 2 AS-i 2-2 AS-i - for AS-i line 2 AS-i 1 + 3 AS-i + for AS-i line 1 AS-i 1-4 AS-i - for AS-i line 1 FE 5 Functional earth 6 not used Terminal X2 Pin Description 24 V 1 +24 V device supply GND 2 GND Terminal X4 Pin Description 1...8 IN1...8 9...12 OUT1...4 13,14 GND 15,16 +24 V power supply Safe-IO module A fixed terminal assignment is mandatory for the safe inputs (IN 1...8) Device manual Installation Connect devices to a local I/O interface. Socket X3 Configuration interface Socket X6 Profinet interface 2 Socket X7 Profinet interface 1 7.2 Connect the supply voltage Supply the device with one of the following versions. 7.2.1 Standard configuration: 24 V power supply and AS-i power supply/ supplies Connect the supply voltage inputs of the device to the power supply intended for this purpose. 10

AS-i bus 1 Connect the pins AS-i 1+ and AS-i 1- of terminal X1 to the AS-i power supply (e.g. AC1236) of the first AS-i bus. AS-i bus 2 Connect the pins AS-i 2+ and AS-i 2- of terminal X1 to the AS-i power supply (e.g. AC1236) of the second AS-i bus. 24V device supply Connect the pins 24 V and 0 V of terminal X2 to a 24 V DC power supply (18...32 V SELV/PELV) 24 V Safe-IO power supply Connect the pins 24 V and GND of terminal X4 to a 24 V DC power supply (18...32 V SELV/PELV) Ensure a low-resistance connection of the symmetry point of the device (terminal X1, pin 5 FE) to the ground of the installation. For the 24 V power supply (device, Safe-IO), select a power supply which supplies an output current of at least 3 A. Power must be applied simultaneously to the Safe-IO module and to the device. The cable length of the DC supply between power supply and AC402S is to be limited to max. 3 m. The power supplies used must meet the standard DIN EN 60950-1 for SELV/ PELV. 7.2.2 Device supply via a joint power supply. If necessary, remove inserted connectors from terminals X1 and X2. Plug the data decoupling module AC1250 (not supplied) in the terminals X1 and X2. Connect the first AS-i bus to the pins AS-i 1+ and AS-i 1- of the data decoupling module. Connect the second AS-i bus to the pins AS-i 2+ and AS-i 2- of the data decoupling module. Connect the DC power supply (21.5...31.6 V SELV/PELV) to the pins 24 V and 0 V of the data decoupling module. UK 11

Connect the pins 24 V and GND of terminal X4 of the AC402S to the abovementioned power supply, or, if required, to another 24 V DC power supply (18...32 V SELV/PELV). Ensure a low-resistance connection of the symmetry point of the device (terminal X1, pin 5 FE) to the ground of the installation. Select a power supply which supplies an output current of at least 3 A. Power must be applied simultaneously to the Safe-IO module and to the device. The cable length of the DC supply between power supply and AC402S is to be limited to max. 3 m. The power supplies used must meet the standard DIN EN 60950-1 for SELV/ PELV. Supply the device and both AS-i lines with the passive data decoupling module AC1250 and a DC power supply (SELV/PELV 21.5 V...31.6 V). The output voltage which is adjusted on the power supply then also corresponds to the voltage level of both generated AS-i bus voltages. The output voltage of the power supply used is therefore to be selected in accordance with the requirements of the application within the permitted limits from 21.5...31.6 V. 7.3 Connect sensors / actuators The sensors and actuators are connected to all local (safe) inputs and outputs via terminal X4. Connect the switching signals of sensors to the pins IN1...IN8 of terminal X4. Connect actuators to the pins OUT1...OUT4 of terminal X4. When external sensors / actuators are connected, their supply voltage and/or reference potential of terminal X4 (Safe-IO module supply) must be tapped. When external sensors are connected, observe the max. permitted supply voltage of the sensor and select the Safe-IO module supply accordingly. The signal cable length for external devices (sensors, actuators) is to be limited to max. 10 m. Do not exceed the maximum output current of 0.5 A per output Do not exceed a switching frequency of 25 Hz when connecting the inductive loads (DC-13). 12

8 Operation 8.1 Notes on the EMC-compliant operation Use voltage supplies for the device that are not simultaneously used for the supply of known interfering sources (e.g. large inductive loads, motor starters, frequency converters, etc.). If the switching outputs of the device are used to control inductive loads (relays, contactors etc.), additional means of suppression have to be provided directly on those loads. Lay the cables of the digital inputs and outputs to be connected via the front UK connector in separated cable ducts. There should be no other cables in these ducts that are control or supply cables of known interfering sources. This is a class A product which is intended for use in industrial applications. The unit may cause radio interference in domestic areas. In this case it can be necessary for the user to take appropriate measures. 8.2 Settings During operation the display is switched off after 10 minutes without operation. Activate the display by pressing any desired button. 8.2.1 Language selection Change the user language of the device by pressing the button and the button or button simultaneously. 13

8.3 Navigation 8.3.1 Navigation elements xxx # xxx xxx 1: User level 2: Selection 3: Operating area 4: Softkey labelling (e.g. menu, OSC) 5: Navigation compass 6: Navigation status bar 7: Main navigation bar 8: Info bar 14

8.3.2 Pictograms and main navigation Quick set-up (summary of the menu points required for a basic configuration) Config all Projection adaptation for AS-i master 1 and AS-i master 2 Operating mode Selection of the operating modes for --AS-i master 1, --AS-i master 2, --Control of the outputs (gateway, manual, PLC) QR code Fieldbus Profinet --Display / modify the parameters of the Profinet interface --IP address --Subnet mask --Gateway address Configuration interface --Display / modify the parameters of the Ethernet configuration interface --DHCP --IP address --Subnet mask --Gateway address Addressing AS-i 1 --Slave overview AS-i line 1 (with the option to change AS-i addresses) Addressing AS-i 2 --Slave overview AS-i line 2 (with the option to change AS-i addresses) UK AS-i 1 AS-i master settings AS-i diagnostics AS-i slaves AS-i 2 AS-i master settings AS-i diagnostics AS-i slaves 15

System PLC --Information --Settings --Diagnostics Information Settings Diagnostics Interfaces Settings and information of the configuration interface Settings and information of the Profinet interface Safety Settings, information and diagnostics of the safe controller Safety Safety functions not available Further details device manual 8.3.3 OSC (Online Support Center) It is accessed via the softkey [OSC] on the start screen. Events, warning and error messages with a time stamp are displayed in plain text. Current version History 16

9 Diagnostics Any information, warning or error messages are indicated in the display on the device. The pictogram of the function unit concerned is superposed by an information, warning or error symbol. If for one function unit a warning and an error message exist at the same time, only the error symbol is displayed. Warning message Information message UK Error message All messages are displayed in plain text in the Online Support Center (OSC). 10 Maintenance, repair and disposal Replace the buffer battery of the real-time clock as required, type CR2032. Dispose of the device in accordance with the national environmental regulations. 11 Approvals / tests EMC Functional safety / TÜV-Rheinland AS-Interface / AS-i Safety at Work UL (culus) Profinet 12 Additional documents Data sheets, device manual, programming manual and registration documents www.ifm.com 17

13 Technical data AC402S Use as an AS-i Profinet gateway with safe preprocessing 4 safe local inputs (two-channel) and 2 safe local semiconductor outputs Electrical data Number of AS-i masters 2 Operating voltage [V] Current consumption from 24 V DC and AS-i [ma] Electrical separation Inputs 18 18...32 DC (AUX) < 750 (24 V) / < 10 from AS-i 1 / < 10 from AS-i 2 Circuits DC PNP (type 2 to IEC 61131-2) Sensor supply Voltage range [V] yes to SELV/PELV 24 DC (18...32 DC) Input current [ma] 7 Outputs Output function Transistor PNP (according to IEC 61131-2) Voltage range [V] External supply 24 DC (18...32 DC) to SELV/PELV Max. current load per output [ma] 500 Max. inductance [mh] 400 Max. switching frequency [Hz] 25 Utilisation category DC-13 (according to IEC 60947-5-1) Electrically isolated Short-circuit protection Interfaces Programming interface Data interface Environmental conditions yes yes Ethernet Profinet RT device class B, 100 Mbaud Ambient temperature [ C] 0...50, for UL application: max. 45 Storage temperature [ C] -20...70 Max. perm. relative air humidity [%] 95, non-condensing Height above sea level [m] < 2000

Protection IP 20 AS-i classification AS-i version 3.0 AS-i profile AS-i certificate 125301 Mechanical data Housing materials M4 Aluminium powder-coated; steel sheet galvanised; Makrolon UK Displays / operating elements Display LED function display Full graphic LCD display 1 x combined LED (red / green) 13.1 Safety classification Meets the requirements of EN ISO 13849-1: 2015 category 4 PL e IEC 61508: 2010 SIL 3 Mission Time (TM) 20 years Safety-related reliability PFHd [1/h] 1.21*10-08 PFD 1.04*10-04 19

14 Scale drawing 93 106,2 128,2 135,5 20

21 UK