Emotron Fieldbus HMS Gateway Anybus Communicator

Similar documents
HMS Anybus configuration setup

Emotron AC drive Master-follower functionality

Instruction manual. Siemens tiastar Gateway Unit.

Anybus X-gateway. PROFIBUS Master Interface NETWORK GUIDE SCM EN 1.0 ENGLISH

Version Action Author Date

Your choice for wall and panel mounted AC drives. Emotron FDU & VFX IP20/21 up to 132 kw

How to Configure DeviceNet with Anybus Configuration Manager (ACM) for DeviceNet APPLICATION NOTE DRAFT

Softstarters. Type PSTX Fieldbus communication, Anybus Modbus TCP. 1SFC132087M0201 March SFC132087M0201 1

Technical Catalogue Softstarters

How to configure a PROFIBUS network with NetTool for PROFIBUS

PTC 2.0 Option board. PTC/RTC Option board. Instruction Manual English. For Emotron VFX/FDU 2.0-IP2Y AC drive. For Emotron FlowDrive-IP2Y

VISY-Command. Technical Documentation. with Modbus Protocol. Edition: Version: 1 Art. no.:

E2 Modbus RTU Register Map Revision History Version Comments Author Date 1.02 Previous version PAE 11/06/ Revised to new format PAE 09/03/09

PTC/PT100 board 2.0 Option

User Manual AnyBus Communicator for Profibus

EN7000 & Anybus Communicator EIP/MODBUS-RTU user guide 1

DT7000 Communication I/O Gateway User s Guide Version 2.6

User Manual. Profibus DP Master to Crowcon Vortex 12 Ch. Generic. Formac Electronics Ltd. T:+44 (0) Oxford House F:+44 (0)

PTC/PT100 board 2.0 Option

VPGate Manual PROFIBUS to serial

4511 MODBUS RTU. Configuration Manual. HART transparent driver. No. 9107MCM102(1739) For 4511 devices from ser. no:

NEMO SX_SXI485_ModbusTable_IME_EN_v1.03.xlsx

Servo press kit YJKP - Host interface

E2 Modbus RTU Register Map

ENGLISH ENGLISH ENGLISH ENGLISH

Serial Connection of HC900 Hybrid Controller to 900CS Control Station

MPU-32 AND FPU-32 TIA-485 NETWORK

Application Note: 105U/905U-G-ET1 EtherNet IP & CompactLogix PLC

ENGLISH ENGLISH ENGLISH ENGLISH

Softstarters. Type PSTX Fieldbus communication, Fieldbus Plug Modbus RTU

User Manual version 1.04 TLM8 COMMUNICATION PROTOCOLS

TxA SoftControl - FnIO-S NA-9173 / NA-9473 Modbus RTU KI

Optidrive VTC Modbus RTU Register Map

RTC- Real time clock board Option

MODBUS TESTER SOFTWARE U S E R M A N U A L

Operator Manual for Profibus

Protocol Manual. Specifications and dimensions are subject to change without notice and do not constitute any liability whatsoever.

ENGLISH ENGLISH ENGLISH ENGLISH

Technical Documentation

Chapter 5: Communications 5 1 SR55 Communications Overview 5 2

T1 4-Channel Protocol Manual

How to configure DeviceNet with Anybus NetTool for DeviceNet.

Modbus ASCII Serial Device Driver Help 2009 Kepware Technologies

Anybus-CC CFW-11. User s Manual. Phone: Fax: Web: -

Fieldbus Option. Instruction manual English. Profibus DP, DeviceNet, CANopen, Modbus/TCP, EtherCAT, Profinet IO, EtherNet/IP

IQ Home Modbus-RTU Master

User Manual Revision English

PROFIBUS Slave. X-gateway Interface Addendum. Doc: HMSI , Rev: Connecting Devices TM

MODBUS APPLICATION PROTOCOL SPECIFICATION V1.1b3 CONTENTS

How to configure an Anybus Modbus-TCP slave module with Unity Pro L

SC168MBM 16x8 Characters MODBUS MASTER LCD

Rev 2.00 NA-9286 (EtherCAT) Page 1 of 31. FnIO S Series: NA EtherCAT Adapter

FnIO S-Series. FnIO MODBUS Adapter Specification Rev 1.00 NA-9473 (MODBUS/RS485) Page 1 of 30. NA-9473 (MODBUS/RS485) Adapter

User Manual Anybus Communicator CAN Modbus RTU

IQ SENSOR NET MIQ/(A-)MOD

MODBUS APPLICATION PROTOCOL SPECIFICATION V1.1b3 CONTENTS

MODBUS APPLICATION PROTOCOL SPECIFICATION V1.1a CONTENTS

Optidrive Applications Support Library

NXIO S Series: NXIO-MNA232, MNA485. MODBUS Adapter

User Manual Anybus Communicator for DeviceNet

How to set-up and read MOBBUS

M3-61B DeviceNet Slave Module. M3-61B DeviceNet Slave Module CONTROL TECHNOLOGY CORPORATION

3GV M Modbus RTU Register Map

FIP IO Slave. X-gateway Interface Addendum. Doc: HMSI Rev: Connecting DevicesTM

Getting Started with your D3000M Series Module

4511 MODBUS RTU. Configuration Manual. Solenoid / alarm driver. No. 9203MCM100(1328)

Fieldbus slave modules w/o I/Os

ATK3 I/O Module (Modbus Slave)

X-gateway Interface Addendum DeviceNet Scanner Interface

Softstarters. Type PSTX Fieldbus communication, Fieldbus Plug Modbus RTU. 1SFC132092M0201 June SFC132092M0201 1

User Manual Anybus Communicator for CC-Link IE Field

Danfoss FCD 300 AS-i and Siemens DP/AS-i Link 20E

4511 MODBUS RTU. Configuration Manual. Pulse isolator. No. 9202MCM101(1707) For 4511 devices from ser. no:

3G3FV SI-P Option Card for Profibus-DP Instructions 02/16/00

Host Controller Systems. Instruction Manual

Model 3000 Fieldbus Transmitter

Table of Contents 1 ABOUT THIS DOCUMENT GENERAL COPYRIGHT INFORMATION TERMS ABOUT THE GATEWAY PRODUCT FUNCTIO

NA-9171 / 9173 (RS-232) (RS-485) User Manual. MODBUS Adapter CREVIS Co.,Ltd. Version FnIO MODBUS Adapter NA-9171, NA-9173 FnIO S-Series

X-gateway Interface Addendum CC-Link Slave Interface

Additional instructions Memograph M, RSG45 Advanced Data Manager

EM23-DIN COMMUNICATION PROTOCOL. Version 0 Revision 0

Fox Thermal Instruments, Inc.

Anybus X-gateway EtherNet/IP

FNL Modbus TCP Interface

1. Overview Technical Specifications Applications Pin Description Connection Diagram of RS 485 / 422 Converter...

Gateways. Industrial networking made easy

WRC Modbus to DeviceNet Gateway for GPD 506/P5

Gateways. Industrial networking made easy

TR600 with RS485 Appendix 1

Document Name: User Manual for SC10MK, Modbus RTU to Modbus TCP Converter

Interface design document MODBUS Protocol. Ab s t r a c t Description of the MODBUS implementation for the Modbus I/O board

Appendix to the Operating Instructions RMx621 with ModBus Interface V Connection to ModBus-IDA System

Mapping Modbus Registers to BACnet Objects

FC 300 DeviceNet and Allen Bradley Control logix 5550

Golander Peristaltic Pump MODBUS Communication Instruction

PROFIBUS-DP MASTER MANUAL. HMS FIELDBUS SYSTEMS AB Pilefeltsgatan S Halmstad SWEDEN. Doc. No. PDP-M-0.993

Universal Serial/PROFIBUS DP Gateway GT200-DP-RS User Manual V6.1 SST Automation

ETOR-4. Ethernet/Serial Gateway USER MANUAL

Power Xpert C445 Motor Management Relay Cheat Sheets

This application note provides clarification of a PowerFlex40 (PF40) used in multi-drive mode, and the advantages and dis-advantages of its usage.

Transcription:

Emotron Fieldbus HMS Gateway Anybus Communicator Quick Start Guide English

Quick start to HMS Gateway Anybus Communicator This document provides a short example on how to configure the Anybus Communicator Gateway from HMS with Emotron MSF 2.0 and Emotron VFX/FDU 2.0. NOTE: All support/questions regarding configuration/ installation of the gateway are handled by HMS Industrial Networks, http://www.hms.se/ Questions regarding the Softstarter or Variable Speed Drive, VSD, are handled by CG Drives & Automation. The following examples show how to configure the telegrams on the sub network side where the gateway works as a modbus-rtu master. Examples of configuration files for the HMS gateway are found under FDU/VFX and MSF at: http://www.emotron.com/services-support/file-archive. The files can be downloaded and reconfigured to your specific application/needs. Hint! Keep the following manuals nearby before continuing: For VSD: Emotron VFX/FDU 2.0 Instruction manual Emotron I/O board 2.0 Option (describes process data mapping) Emotron Isolated RS232/485 2.0 Option (describes modbus rtu protocol) For Softstarters: Emotron MSF 2.0 Instruction manual Emotron MSF 2.0 Fieldbus Option (describes process data mapping) Emotron MSF 2.0 Serial Communication Option (describes modbus protocol) In the following examples the modbus registers for the 4 bytes process data (described in each corresponding fieldbus manual) are mapped to the double port memory of the gateway. This enables access (read/write) of selected modbus registers from the fieldbus side. General configuration Gateway NOTE: Please refer to the Anybus Communicator manual on www.hms.se for detailed information. The following text describes step by step how to configure the gateway and sub network. NOTE: Preconfigured examples both for MSF 2.0 and VSD 2.0 may be downloaded from www.emotron.com under File archive. 1. Start ABC Config Tool program. 2. Choose Blank Configuration and press OK. NOTE: The wizard does not allow byte swapping, therefore the manual configuration mode is recommended. Fig. 1 CG Drives & Automation 01-5971-01r1 1

3. Click on Fieldbus to the left and choose Fieldbus type to the right. Fig. 2 4. Click on Sub-Network to the left 5. Make appropriate settings for baudrate, data bits (8), parity (none), physical interface and stop bits (2) matching the settings in MSF/FDU/VFX. Fig. 3 2 CG Drives & Automation 01-5971-01r1

6. Expand Sub-Network structure (with +) to the left and add the number of slave nodes you want on the sub network. Click on the Sub-Network and select Add node to add a new node. You may rename the name of the New Node to something more appropriate, e.g. like Inverter2. 7. For each node you add you must select a unique address, matching the address setting in the product (MSF, FDU or VFX). To do this, click on the Node name and select Slave address to the right. Fig. 4 8. Right click on the node name again and select Add transactions. 9. Continue to chapter Setup sub network for your specific product. CG Drives & Automation 01-5971-01r1 3

Setup sub network for MSF 2.0 First setup the MSF menus: For detailed menu information, please check manuals listed above. Setup the following menus: [200] Selection of control sources set to 3 = Serial communication control [270] Serial comm unit address [271] Serial comm baudrate [272] Serial comm parity set to 0 = No parity [273] Serial comm contact broken NOTE: The exact same address, baudrate etc. should be configured for the gateway. We will now continue our configuration of the gateway to setup a modbus rtu message that will read and write modbus registers containing the 4 byte fieldbus process data. Fig. 5 Under transactions you can now fill in the following data (right click on the Query or Response field and add Byte constant/word constant or according to the table below). 4 CG Drives & Automation 01-5971-01r1

Query msg MSF Table 1 Field name Query Set to Right click on query and add as Slave Address Same as in MSF Byte constant Function Set to 0x41 for MSF (Emotron specific function code for process data registers only) Byte constant Read Starting Address (Hi,Lo) 0x26F1 Word constant Quantity to Read (Hi,Lo) 0x0003 Word constant Write Starting Address (Hi,Lo) 0x26F1 Word constant Quantity to Write (Hi,Lo) 0x0003 Word constant Write byte count 0x06 Byte constant 1 2 3 location 0x0400 (This status reg must be read but is not mapped to process data area) Byte swap: Don t care location 0x0202 (optional) location 0x0200 (optional) Checksum Use default values Checksum Response msg MSF Table 2 Field name Response Set to Right click on response and add as Slave Address Same as in MSF Byte constant Function Set to 0x41 for MSF (Emotron specific function code for process data registers only) Byte constant Byte Count 0x06 Byte constant 1 Read Register Value 1 Read Register Value 2 location 0x0400 (This status reg must be read but is not mapped to process data area) Byte swap: Don t care location 0x0002 (optional) location 0x0000 (optional) Checksum Use default values Checksum CG Drives & Automation 01-5971-01r1 5

Setup sub network for FDU/VFX 2.0 First setup the VSD menus: For detailed menu information, please check manuals listed above. Setup the following menus: [214] Reference control [215] Run/Stp control [216] Reset control [261] Com type Set to RS232/485 [2621] Baud rate [2622] Address NOTE: The exact same address, baud rate etc. should be configured for the gateway. We will now continue our configuration of the gateway to setup a modbus rtu message that will read and write modbus registers containing the 4 byte field bus process data. Fig. 6 Under transactions you can now fill in the following data (right click on Query or Response field and add Byte constant/word constant or according to table below). 6 CG Drives & Automation 01-5971-01r1

Query msg Inverter Table 3 Field name Query Set to Right click on query and add as Slave Address Same as in Inverter Byte constant Function Set to 0x17 Read/Write Multiple registers Byte constant Read Starting Address (Hi,Lo) 0x26F2 Word constant Quantity to Read (Hi,Lo) 0x0002 Word constant Write Starting Address (Hi,Lo) 0x26F2 Word constant Quantity to Write (Hi,Lo) 0x0002 Word constant Write byte count 0x04 Byte constant 1 2 location 0x0202 (optional) location 0x0200 (optional) Checksum Use default values Checksum Response msg Inverter Table 4 Field name Response Set to Right click on response and add as Slave Address Same as in Inverter Byte constant Function Set to 0x17 Read/Write Multiple registers Byte constant Byte Count 0x04 Byte constant Read Register Value 1 Read Register Value 2 location 0x0002 (optional) location 0x0000 (optional) Checksum Use default values Checksum CG Drives & Automation 01-5971-01r1 7

General hints Speeding up the sub network The speed on the sub network depends on several issues: Baud rate Telegram length/amount of data Number of slave nodes on the RS485 sub network (sharing bandwidth to master) Update time (i.e. minimum time between two transactions) In general it is preferred to achieve a fast response. Try to keep the time between two transactions of a kind as short as possible. This can be altered by marking the Query to the left and altering the Update time (10 ms) value to the right, see Fig. 7. Fig. 7 location & byte swapping PLC s of different brands may use different data formats (little endian or big endian). Depending on this you may have to perform byte swapping, either in the PLC or in the Gateway. NOTE: The length value must be set to 0x0002 before you can alter the Byte swap setting. You may also swap registers (words) if necessary by altering the location in the DP memory. Example for Profibus: The Anybus communicator gateway (Profibus DP) has been configured for a VSD FDU/VFX 2.0 exactly as in the example above. This means that the process data mapping will be exactly the same with the gateway as for the Fieldbus I/O board 2.0 option (standard Profibus option). 8 CG Drives & Automation 01-5971-01r1

Fig. 8 Using a profibus DP Master simulator with 4 bytes of process data in/out. The first output data Byte 1: is set to 0x03=Run and Run to the right Byte 2: Drive mode = speed, and parameter set A Byte 3 and 4: Reference Signal. According to Fig. 8, the first output data: Byte 1: is set to 0x03=Run and Run to the right Byte 2: is set to 0x00 which corresponds to Drive mode=speed, and parameter set A Byte 3 and 4: Reference Signal. Input data: Byte 1: is 0x8B=1000 1011b=Running, run right, Relay 1 on, Run Ctrl=run/stp by com. Byte 2: is 0x00=Drive mode speed, no warning/error status. Byte 3: AnOut1 value Byte 4: AnOut2 value. Input data Byte 1: is 0x8B = 1000 1011b = Running, run left, Relay1 on, Run Ctrl=1=run/stp by com. Byte 2: is 0x00 = Drive mode speed, no warning/error status. Byte 3: AnOut1 value Byte 4: AnOut2 value. The mapping is 1:1 compared to the Fieldbus I/O board 2.0 Option manual, i.e. same byte order. In the same manner the MSF example above will give a 1:1 mapping according to the process data in the Emotron MSF 2.0 Fieldbus Option manual. Network comparison chart The example above is a configuration for a Profibus network. Profibus uses the Big endian format, which means that the most significant byte (MSB) comes first (on the lowest memory address). If you use another network which uses the little endian format, you may change the byte swapping in the example above, either in the gateway or in your PLC. Table 5 Profibus Ethernet/IP CC-Link DeviceNet CANopen Modbus RTU Modbus/TCP Example data format network comparison list Network MSB first LSB first LSB first LSB first LSB first LSB first LSB first format CG Drives & Automation 01-5971-01r1 9

CG Drives & Automation Sweden AB Mörsaregatan 12 Box 222 25 SE-250 24 Helsingborg Sweden T +46 42 16 99 00 F +46 42 16 99 49 www.emotron.com / www.cgglobal.com CG Drives & Automation, 01-5971-01r1 2015-04-20