Securing your power supply

Similar documents
Protection Equipment

MEDIUM VOLTAGE PRODUCTS. UniSec Air-insulated medium voltage secondary distribution switchgear Informed choice for safety

3RA13, 3RA14 Contactor Assemblies

Approved Standards. Motor Protection Circuit Breaker (MPCB) J7MN. MPCB system (motor protection CLASS 10) Auxiliary contact modules.

7000 SERIES Power Switching Solutions. Closed Transition Transfer Switching. Delayed Transition Transfer Switching

RB60 RANGE. Miniature circuit breakers

Sentron 3VT circuit breakers Simply Smart: First choice for power distribution

Switch Disconnectors, Main and EMERGENCY-STOP Switches

QUICK REFERENCE PRICE GUIDE JUNE 2016

IDE Load break switches for machine control Remotely trippable switch from 32 to 160 A

Circuit Breakers, Type CTI 25M, CTI 45MB, CTI 100

Disconnect Switches. Safe Switching and Disconnecting

J7MN. Ordering Information. Motor Protection Circuit Breaker. Model Number Legend. MPCB system. Options. Motor Protection Circuit Breaker J7MN I-1

MOTOR PROTECTION CIRCUIT BREAKERS

Products and solutions for generating sets

AThink future. Switch to green. MCCB Panel Boards 400A / 630A / 800A.

Automatic Transfer Switch OTM_C_20D. Installation and Operation Instructions

Siemens AG KD Switch Disconnectors SENTRON. Edition December Answers for infrastructure and cities.

125A SPN, type A distribution boards Incoming devices Meterpack assemblies Surge protection devices... 34

ATS22D17Q soft starter-ats22-control 220V-power 230V (4kW)/ V(7.5kW)

Series 230 Automatic Transfer Switch

MULTI 9 System Catalog UL Recognized C60N Supplementary Protectors

ATS22D17Q soft starter-ats22-control 220V-power 230V(4kW)/ V(7.5kW)

Circuit Breakers Type CTI 25M, CTI 45MB

TP&N DISTRIBUTION BOARD TYPE B RANGE

Switches 6/1. 6/4 Introduction. 6/5 5TE8 control switches. 6/7 5TE4 8 pushbuttons. 6/9 5TE8 On/Off switches. 6/11 5TE1 switch disconnectors

3RV1 Circuit-Breakers

Approved Standards. Motor Protection Circuit Breaker (MPCB) J7MN. MPCB system (motor protection CLASS 10) Auxiliary contact modules.

ASCO SERIES 230 Automatic Transfer Switch

SECTION SOLID-STATE REDUCED VOLTAGE STARTERS

MULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors

PowerFlex 400 AC Drive Guide Specification

IMS Control & EPR, We keep your motors running ABB s new control & protection devices up to 18.5 kw / 20 hp

pointofsale available at your local trade outlet

OVERLOAD RELAYS POWER & ACTUATION PROVEN. series

IPS INTELLIGENT PUMP STARTER

1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Manual Motor Protectors. XT IEC Power Control

194E FA 32 E P11 P11 6

Automatic Transfer Switch OTM_C20D

Series 230 Automatic Transfer Switch

AThink future. Switch to green. Mini Panel Board. Cost-effective, space-saving board up to 400A.

ATV12P075M3 variable speed drive ATV kW - 1hp V - 3ph - on base plate

ATS22D75S6 soft starter-ats22-control 220V-power 230V(18.5kW)/ V(37kW)/500V(45kW)

Issued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog

LM10 to MM200 Retrofit

L.V. Systems & Solutions

63 to 125 A. Functions. Conformity standards. General characteristics. Changeover switches SIRCO VM1 changeover switches.

1S20. Arc Fault Monitor Relay. Features. Introduction. ARC Fault Protection

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

CI-TI Contactors and Motor Starters Circuit Breakers CTI 25M, CTI 45MB, CTI 100

SIGUARD Safety Combinations and Safe Load Feeders. safety INTEGRATED

4. CIRCUIT BREAKERS. Functional Emergency Switching

SENTRON 3VL Molded Case Circuit Breakers

SIRCO Load break switches for power distribution from 125 to 5000 A

Solid-State Contactors

Motor Control Products Selection Guide

ATS22D62Q soft starter-ats22-control 220V-power 230V(15kW)/ V(30kW)

SED2 Variable Frequency Drives

ATV12H075M3 variable speed drive ATV kW - 1hp V - 3ph - with heat sink

ATV12HU22M3 variable speed drive ATV12-2.2kW - 3hp V - 3ph - with heat sink

5.1. Motor Protection and Monitoring. Contents. Product Overview. Monitoring Relays. D64R Series Digital Ground Fault Relays...

C C CIRCUIT-BREAKERS Moulded-case (MCCB), general. 1. Introduction. 2. General description

SED2 Variable Frequency Drives Conventional Bypass (C-Bypass) Options

SENTRON ATC Automatic Transfer Control Device

PGR-6101 MANUAL GROUND-FAULT & INSULATION MONITOR

60103 Circuit Breaker

24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD

RCDs RCBOs MCBs Isolating Switches Switchboards

100% electricity. Automatic transfer switch controllers ATL series

LOW VOLTAGE BYPASS/ISOLATION BREAKER BASED AUTOMATIC TRANSFER SWITCHES SECTION 16496D

29 $ Manual Motor Starters FREESHIPPING. MOTOR CONTROLS 25. Features: MMS-32H Frame. MMS-63H Frame.

mcbs, EQUIPMENT NEW PRODUCTS 2014 Voltage surge protectors & other control and signalling devices Time & light sensitive switches

ISOMETER isoev425 with coupling device AGH420

Catalog. Arc Guard System TM TVOC-2

Spending too much to maintain aging switchgear? Circuit breaker solutions from Square D Services.

SACE Emax 2 Specification guide

Low voltage. NG to 160 A. Modular incoming circuit breakers and switch-disconnectors for DIN-panel installation.

Series 230 Automatic Transfer Switch

MG24434 Supplementary Protector SUPPLEMENTARY PROTECTOR, 240VAC, 16A, CIRCUIT BREAKER TYPE: STANDARD

SED2 Variable Frequency Drives with Electronic (E) Bypass Options

Allen-Bradley Bulletin 100 Contactors

AUTOMATIC TRANSFER SWITCH CONTROLLERS ATL SERIES

LOGIC CONTROLLER INSTALLATION MANUAL NTR 756 B /E

PanelFAST. Setting a new standard for immediate product availability with Square D Ready to Install (RTI) Panelboards

ATV12P037F1 variable speed drive ATV kW hp V - 1ph - on base plate

Substation Automation Products. Bay control REC670/650 Relion 670 and 650 series

Installation Manual for D244X Series 24-volt Power Supplies

Transfer Switches 5.1 Transfer Switch Equipment Product Selection Guide... Product Description... Application Description...

Features and Benefits of XeteX Controls. Other Unit Control Functions. Energy Recovery Functions

4-step Chiller and Heat Pump Controller

ATS22D75Q soft starter-ats22-control 220V-power 230V(18.5kW)/ V(37kW)

Havells Switchgear. Trade Price List. PowerSafe - Commercial Range

Section 4 Ground-Fault Protection Devices

ATS22D88S6U. ATS22D88S6U soft starter-ats22-control110v-power 208V(25hp)/230V(30hp)/460V(60hp)/575V(75hp) Product data sheet Characteristics.

FUSERBLOC UL Fusible disconnect switches UL and CSA from 30 to 800 A

ENERGY AND AUTOMATION

ATV12H018M2 variable speed drive ATV kW hp V - 1ph

Air-insulated medium-voltage secondary distribution switchgear

194E FA 32 E P11 P11 6

Rotary switches T and switchdisconnectors. reliable switching, disconnection, control and operation

Transcription:

Securing your power supply Change-over Enclosed automatic and transfer switches for for critical Critical power Power applications applications Power and productivity for a better world TM

Enclosed automatic transfer switches ABB low voltage component capabilities for critical power applications Critical power applications require a constant and reliable power supply to keep fundamental services running and prevent serious consequences arising due to interruption or absence of the electrical grid. This need is even stronger nowadays because of the increasing significance of the key role, capacity and features of these systems. Selection of a source of switching, control and protection components capable of sustaining the needs of a critical power application is paramount, ABB has a well proven track record within this environment. 2 Critical Power Automatic Transfer Switches

In today s world, electrical power plays a key role in almost every activity of our life. For some equipment a reliable, uninterruptible and free of disturbance power supply is an absolute essential. From this point of view, a fault in the power supply of communications systems, hospital apparatus, security systems, water and gas distribution devices, banking computers and many other crucial applications may bring about serious problems, with consequences that can be devastating. All these applications can be identified as Critical Power applications: ABB can offer a wide range of components for on board installation and complete power distribution systems. These products include:- automatic transfer switches (ATS) and automatic control units (ACU), manual and motorised change-over switches, isolators, switch-disconnectors air, moulded-case and miniature circuit breakers, protection devices against overvoltages, contactors, current sensors and many other devices. ABB products comply with the most important international standards - either European or North American - and with the requirements of the Navy Registry; they are also designed and built on the basis of the most modern and advanced environmental standards. ABB products are backed by a consolidated eperience in power and automation technologies. They are supported through a global assistance and service network which covers more than 100 countries all over the world. Critical Power Automatic Transfer Switches 3

Enclosed automatic transfer switches functionality & features As industrial processes and IT applications diversify, a secure power supply is becoming an increasingly important asset in the drive to cut production and maintenance costs. In emergency situations, the system logic of power distribution can become comple with mechanical devices looking after making, breaking, conducting and isolating power. Loads may sometimes need to be transferred from one supply to another this will be the case when energy use is restricted or when the supply source is overloaded. High performance level In change-over applications where the loaded switch may need to be operated remotely, adequate durability has been ensured by testing against the IEC 60947-6-1 standard in the specification of endurance requirements. Utilisation categories: AC-31 for non-inductive or slightly inductive load AC-33 for motor loads or mied loads including motors ABB change-over switches are rated according to IEC 60947-6-1 standard. 4 Critical Power Automatic Transfer Switches

Functionality Includes automatic control unit OMD300_ OMD800_ Manual operation with handle Local operation with front panel keypad Measurements Three phase voltage measurement on LINE 1 & 2 Single phase voltage measurement on LINE 1 & 2 Frequency on LINE 1 & 2 Source failure detections No voltage Undervoltage Overvoltage Phase missing Voltage unbalance Invalid frequency Incorrect phase sequence Configuration By DIP switches By rotary switches By keypad and LCD Voltage threshold setting Voltage hysteresis setting Frequency threshold setting Frequency hysteresis setting Time delays Switching delay 1) Delay on transfer 2) Dead band time I-II (stop switching to position O) Back-switching delay 3) Dead band time II-I (stop switching to position O) Generator stop delay 4) Status of time delays on the LCD Features Includes automatic control unit OMD300_ OMD800_ Generator start and stop Off-load test sequence On-load test sequence Source status via front panel Source status via digital outputs Switch position via front panel Modbus interface Event/alarm log Counter for number of operations Auiliary voltage supply Programmable digital inputs (eight) and digital outputs (si) Secondary load control (load shedding) Digital input - Allow transfer to secondary Digital input - Generator alarm Digital input - Remote control to positions I, O and II Operating mode Line priority 5) 6) Manual back-switching Automatic operation to position O, in case ofsource failure 1) Four options: 0, 5, 10 or 30 seconds 2) Delaying the switching sequence before transferring to generator, guaranteeing that in cold locations the generator is properly warmed up 3) Two options: the duration of back-switching delay is the same as switching delay, i.e. the time delay is same for I - II and II - I, or the back-switching delay is fied 300 seconds 4) Two options: the duration of generator stop delay is the same as Switching delay or fied 5 min 5) Two options: No line priority, or Source 1 is the priority source 6) Three options: No line priority, Source 1 or Source 2 is the priority source = included as standard Critical Power Automatic Transfer Switches 5

Enclosed automatic transfer switches selection Enclosed automatic transfer switches, I-O-II operation, open transition ATS 4 pole with OMD300 & OMD800 controller, blank door, wall mountable Description Rated Current (A) Enclosure Size (mm) Controller OMD300 Controller OMD800 H W D Type Order No Type Order No ATS 40A 40 600 600 250 1TVC004014S3000 OTA40E4C3SR 1TVC004014S8000 OTA40E4C8SR ATS 63A 63 600 600 250 1TVC006314S3000 OTA63E4C3SR 1TVC006314S8000 OTA63E4C8SR ATS 125A 125 600 600 250 1TVC012514S3000 OTA125E4C3SR 1TVC012514S8000 OTA125E4C8SR ATS 160A 160 600 600 250 1TVC016014S3000 OTA160E4C3SR 1TVC016014S8000 OTA160E4C8SR ATS 250A 250 600 600 250 1TVC025014S3000 OTA250E4C3SR 1TVC025014S8000 OTA250E4C8SR ATS 400A 400 800 600 300 1TVC040014S3000 OTA400E4C3SR 1TVC040014S8000 OTA400E4C8SR ATS 630A* 630 1000 800 400 1TVC063024S3000 OTA630E4C3AM 1TVC063024S8000 OTA630E4C8AM ATS 800A* 800 1000 800 400 1TVC080024S3000 OTA800E4C3AM 1TVC080024S8000 OTA800E4C8AM ATS 1000A* 1000 1400 800 500 1TVC100024S3000 OTA1000E4C3AM 1TVC100024S8000 OTA1000E4C8AM ATS 1250A* 1250 1400 800 500 1TVC125024S3000 OTA1250E4C3AM 1TVC125024S8000 OTA1250E4C8AM ATS 1600A* 1600 1400 800 500 1TVC160024S3000 OTA1600E4C3AM 1TVC160024S8000 OTA1600E4C8AM * Floor standing plinths from accessories below. Bypass options are available on request. Other wall mounting and floor standing versions available on request. Optional etras Description Type Order No 2 pilot lights 1TVC151800S2311 ATS2PL Door mounted controller complete with IP54 cover plate 1TVC151800S2312 ATSDMC Energy meter 1TVC151800S2313 ATSEM Aniti-condensation heater with thermostat 1TVC151800S2314 ATSHT Accessories Enclosed Automatic Transfer Switch with ATS2PL & ATSDMC optional etras Description Suitable switch Type Order No N/O auilliary for on right hand side of switch OTA40-1600 1SCA022673R1140 OA1G10 N/O auilliary for on left hand side of switch 1SCA022744R2240 OA7G10 N/C auilliary for on right hand side of switch OTA40-125 1SCA022353R4890 OA8G01 N/C auilliary for on left hand side of switch 1SCA022456R1710 OA1G01 N/C auilliary for on right hand side of switch OTA160-1600 1SCA022456R7410 OA3G01 OTA40-125 1SCA022870R9430 OHB65D6CM Direct mounting handle, padlockable with 3 OTA160-250 1SCA022804R0570 OTV250ECMK padlocks in 0 position. Includes shaft and OTA400 1SCA022843R2900 OTV400ECMK mech cover OTA630-800 1SCA022804R3410 OTV800ECMK OTA1000-1600 1SCA111301R1001 OTV1000ECMK OTA40-125 1SCA117524R1001 OVTS0 Handle and spare fuse storage clip OTA160-250 1SCA111413R1001 OVTS1 OTA400-1600 1SCA111414R1001 OVTS2 IP54 cover plate for door mounting ATS controller All 1SCA101001R1001 OMZC2 Yale type key, 19mm dia bo with security insert OTA40-400 AA8002 AA8002 Unique coded Yale insert lock OTA630-1600 EV1036 EV1036 A4 Document pocket All EV1075K EV1075K Blind plinth flanges (pair) H100 W800mm OTA630-1600 ZN8000 ZN8000 Blind plinth flanges (pair) H100 W400mm OTA630-800 ZN4011 ZN4011 Blind plinth flanges (pair) H100 W500mm OTA1000-1600 ZN5011 ZN5011 Wall mounting brackets (4 off) OTA40-400 ZN0008 ZN0008 Anti tilting brackets (pair) OTA630-1600 AA1206 AA1206 6 Critical Power Automatic Transfer Switches

Critical Power other ABB products Moulded case & Air Circuit Breakers The moulded case circuit breakers of Tma XT series cover low voltage applications up to 250A, while the Tma T familiy offer current ratings up to 3200A. The Ema air circuit breakers up to 6300A and it ensures short circuit perfomances up to 150kA. Residual current devices ABB range of modular and front panel residual current devices includes F200 RCCB, DS200 RCBO and RD residual current relays. Arc Monitor TVOC-2 is ABB s state-of-the-art solution for arc fault protection in all applications, providing functional safety. Electronic products and relays (EPR) The versatile range of electronic products and relays offers a maimum of security, economic efficiency and capacity. The range covers products from analog signal converter up to measuring and monitoring relays and time relays. Block Contactors - AF series three poles contactors from 9A to 2050A (AC1, 40 C), with electronic interface coil - A and AF series four poles contactors up to 125A (AC1, 40 C) - EK series four poles contactors from 110A to 1000A (AC1, 40 C) ABB offers a range of installation contactors up to 63A for DIN Rail enclosures. Residual current devices ABB range of modular and front panel residual current devices includes F200 RCCB, DS200 RCBO and RD residual current relays. Manual Motor Starter Manual Motor Starter covers a range up to 100 A for motors protection up to 45 kw / 400 V. Critical Power Automatic Transfer Switches 7

Contact us ABB Ltd Tower Court Foleshill Enterprise Park Courtaulds Way Coventry CV6 5NX Tel: 02476 368500 Fa: 02476 364499 www.abb.co.uk/lowvoltage email: LV.Enquiries@gb.abb.com Twitter follow us @ABBUKLVP Publication Number: 9AKK105713A8079 Power and productivity for a better world TM