Contents 1. Summary

The 8-fold switch actuator is a DIN rail mounted device for insertion in the distribution board. It is connected to the EIB via a bus terminal.

EAE KNX IP Router Product Manual IPR100 (sayfa düzeni ve foto düzenlemesi gerekli)

ABB i-bus EIB / KNX Telephone Gateway TG/S 3.1

instabus KNX / EIB product documentation

ABB i-bus KNX IP Router, MDRC IPR/S 3.1.1, 2CDG110175R0011

Connections, displays and operating elements C D

ABB i-bus KNX Application Unit Time ABZ/S 2.1 Product Manual

ABB i-bus KNX Logic Controller ABA/S 1.2.1, 2CDG110192R0011

IP/ KNX Convertor K-BUS R. User manual-ver.1 BTIC-01/00.1. KNX/EIB Intelligent Installation Systems

Power Supply System KNX PS640-IP

KNX/EIB Intelligent Installation Systems

Operating and mounting instructions

ABB i-bus EIB / KNX Shutter Actuator with Manual Operation, 4-fold, SMI, MDRC JA/S 4.SMI.1M. Product Manual. Intelligent Installation Systems ABB

SK CU4-EIP-C Part number:

DOCUMENTATION UIMip TECHNICAL AND APPLICATION DESCRIPTION. Last modification: 8 September 2017

ABB i-bus KNX AC/S Application Controller

Linienkoppler S KNX. Line coupler S KNX. Line coupler S KNX Status: March 16 (Subject to change) Page 1 of 29

K-BUS Shutter Actuator. User manual-ver. 1

ABB i-bus KNX Weather Unit, 1-fold, MDRC WZ/S , 2CDG110184R0011

DOCUMENTATION UIMip. Authors: Manouchehr Ghahramanian Golzar, Peter Hauner. Last Modification:

USER MANUAL CU-DIN IPRT KNX EC MA

PRODUCT MANUAL. ABB i-bus KNX SV/S KNX-Power Supplies

Technical Manual MDT IP Router

RS485/ KNX Bidirectional Converter K-BUS R. User manual-ver.1.3 BTPT-02/ KNX/EIB Intelligent Installation System

Product and Applications Description

Power Supply System KNX PS640+IP

Use of the application program. 1. Functional description. instabus EIB Application Program Description. August 2016.

ABB GPG Building Automation, November 2016 ABB i-bus KNX Logic Controller ABA/S ABB Group November 10, 2016 Slide 1

K -B U S R. R S232/ K N X C ontroller. U ser m anual-v er.1 BTCC-02/ KNX/EIB Intelligent Installation Systems

IP Router KNX Product manual

Product Manual V ABB i-bus EIB / KNX DALI-Gateway DG/S 1.1. Intelligent Installation Systems ABB

The output variables can be force-controlled from a coordinating control system.

Product and Application Description

Fieldgate SFG500. Technical Information. Intelligent Ethernet/PROFIBUS gateway

ABB i-bus KNX DALI Gateway Emergency Lighting DGN/S Product Manual

ABB i-bus KNX Analogue Input, 4-fold, MDRC AE/S , 2CDG110190R0011

SK CU4-PNT-C Part number:

Use of the application program

Operation and installation manual KNX IP LineMaster 762 (Art. # 5212) KNX Power supply with integrated KNX IP Router and diagnosis functions

Operating voltage Maximum

Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011

SK TU4-PBR Part number:

ABB i-bus EIB / KNX Blower/Fan Coil-Aktuator LFA/S 1.1, LFA/S 2.1. Product Manual. Intelligent Installation Systems ABB

Sauter Systems

Product and functional description

ABB i-bus KNX DALI Light Controller, 8-fold, MDRC DLR/S M, 2CDG110101R0011

Technical Manual MDT IP Router

SK TU4-CAO-C Part number:

connecdim Gateway G1 Ethernet TCP/IP to DALI

Technical Information Fieldgate SFG500

Datasheet RCUXXYY EAE KNX Room Control Unit RCUXXYY DT R1.0. General Description. EAE Technology Page 1/10

K-BUS R. Dimming Actuators. User manual-ver. 4 KA/D KA/D KA/D KA/D 04.T1.1 ADTV-04/16.1 KA/D 04.L1.1 ADLD-04/

ABB i-bus KNX Analogue Actuator, 4-fold, MDRC, 0-10 V, 0-20 ma AA/S 4.1.2, 2CDG110202R0011

COMTRAXX COM465IP. Condition Monitor with integrated gateway for the connection of Bender devices to Ethernet TCP/IP networks

KNX IP router Order No

Nuvo KNX InterfacePoint Integration Guide

Operating Instructions. DALI-Gateway

COMTRAXX COM465DP. Condition Monitor with integrated gateway for the connection of Bender devices to PROFIBUS DP and Ethernet TCP/IP networks

Product and functional description. Application Program. instabus EIB Technical product information. April (6 x AC 230 V / 0,05 A)

ABB i-bus KNX Binary Inputs BE/S Product Manual

Application description for the KNXnet/IP Interface Web

Product and functional description

IntesisBox KNX - BACnet/IP Client

IntesisBox KNX SAMSUNG NASA Air Conditioners

ABB i-bus KNX Switch Actuator, x-fold, 6 A, MDRC SA/S x.6.1.1, 2CDG x R0011

SK CU4-ECT-C Part number:

SK CU4-PBR-C Part number:

Technical Description

VEO. V2ZS V AC/DC Art.Nr.: V2ZS20P V AC/DC Art.Nr.: TECHNICAL DATA

Application program usage. Functional description

COMTRAXX COM465IP. Condition Monitor with integrated gateway for the connection of Bender devices to Ethernet TCP/IP networks

modunet292: novanet-ethernet interface

1 Safety instructions. 2 Device components. 3 Function. IC00P01DAL - DALI gateway. DALI gateway. Operating instructions

KNX USB INTERFACE UIMtp

Installer Manual Line/Field coupler KNX standard, installation on DIN rail (60715 TH35)

IntesisBox KNX - AIRZONE

EAE KNX Switch Actuator

Belimo Gateway MP to Modbus RTU - UK24MOD

GS Dupline Profinet Gateway. Benefits. Description

IntesisBox Modbus Server Panasonic

Operation and installation manual KNX IP Router. Application. Coupler function (KNXnet/IP Routing)

Gateway configuration manual IP - KNX EK-BE1-TP

Control elements. Fine adjustment. Status indication. 24 V DC typ. 0,25 W / 0,25 VA. 24 V DC typ. 0,03 W / 0,09 VA. 0,15 3 s. 0,5 10 h.

Product and Applications Description. Example of Operation. Installation Instructions WARNING. Note. Application Programs

Nuvo KNX InterfacePoint. Integration Guide

Product and functional description

Manual and application description KNX/EIB LED driver V2.0

Product and Applications Description. Application Programs. Note. instabus EIB Technical Product Information. June 2005

ABB i-bus KNX Switch Actuator, x-fold, 16 A, MDRC SA/S x , 2TAZ710xx1R2161

Interface AP 146 5WG AB01 for Ethernet-UDP/IP. EIB Device. EIB Device. EIB Device

COMTRAXX COM460IP. BMS-Ethernet-Gateway

SK CU4-CAO Part number:

Product and Applications Description. Note. Example of Operation. Installation Instructions. Application Programs WARNING

Transcription:

, GH Q631 0067 R0001 The IP gateway IG/S is the interface The IP address of the IG/S can be between EIB / KNX installations and IP fixed or received from a DHCP server. CDC 071 130 F0003 networks. Data can thus be exchanged between EIB devices and devices on the IP network. The IP gateway can also be used as a line or backbone coupler and thereby use the LAN (10 Mbit) for the rapid exchange of telegrams between the lines/areas. Together with the iets Software, EIB / KNX devices can be programmed from the LAN side via the IG/S. The power supply can be carried out via 30 V AC and/or 1 V DC. The IP gateway is a DIN rail mounted device for insertion in the distribution board. The connection to the ABB i-bus is established via the bus connection terminal. Technical data Power supply Operating voltage 30 V AC + 10 %/ 15 %, 45 65 Hz or 1 V DC (10 30 V DC) Power consumption ca. ma at 30 V, ca. 130 ma at 1 V Power consumption via EIB < 50 mw Operating and display elements Red LED and push button (5) for entering the physical address ON LED (7) Lights up green, if the power supply is available and the device is ready for operation (max. after 140s); Flashes green, if the device starts up (after connecting the power supply) the network connection must exist LAN/Link LED (8) Lights up yellow, if the connection is available with an Ethernet network Flashes yellow, in the event of data traffic Connections LAN RJ45 socket for connection to an Ethernet network (10 BASE-T, IEEE 80.3) 30 V AC 1 screw terminal for L 1 screw terminal for N 1 screw terminal for PE Wire range: finely stranded: 0..5 mm single-core: 0. 4.0 mm 1 V DC 1 screw terminal for + 1 V 1 screw terminal for 0 V Wire range: finely stranded: 0..5 mm single-core: 0. 4.0 mm EIB Bus connection terminal (black/red) Type of protection IP 0, EN 60 59 Ambient temperature range Operation 0 C + 50 C Storage 5 C + 55 C Transport 5 C + 70 C Design Modular installation device, prom Housing, colour Plastic housing, grey Installation on 35 mm mounting rail, DIN EN 60715 Dimensions 90 x 108 x 64 mm (H x W x D) Mounting depth/width 68 mm/6 modules at 18 mm Weight 0.4 kg Mounting position as required Certification EIB- and KNX-certified CE norm in accordance with EMC guideline and low voltage guideline Page 1 of 8 IGS_11_TD_EN_V-0 CDC 50 03 D0101

R ABB i-bus EIB / KNX, GH Q631 0067 R0001 Application program Number of Max. number of Max. number of communication objects group addresses associations IP Gateway /1 9 0 0 Circuit diagram L N 1 1 3 L N ABB i-bus EIB Us 1 V DC ABB i-bus EIB EIB LAN LINK/ACT Ethernet 10 MBit/s 4 5 LAN 1 VDC 3 ON 8 7 6 5 4 CDC 07 196 F0003 1 30 V AC connection 5 Programming LED 1 V DC connection with programming button 3 Ethernet connection (LAN) 6 Nameplate 4 EIB connection 7 Operating LED (On) 8 Display LINK/Act Note The programming is carried out with ETS from version ETS V1.a onwards. The IP gateway is supplied with a downloaded application program. Only the group addresses and parameters therefore need to be loaded during commissioning. If required, the complete application program can be loaded however. When programming several devices, please note the programming sequence (see page 8). Page of 8 IGS_11_TD_EN_V-0 CDC 50 03 D0101

, GH Q631 0067 R0001 IP-Gateway /1 General tab If no group telegrams should be sent from the LAN to the EIB, the option Physically addressed telegrams route (default setting) block block must be selected. All the group telegrams from the LAN to the EIB are then blocked without taking the filter table into account. Selection in ETS ABB System components Coupler In the setting route, all the telegrams from the EIB to the LAN and from the LAN to the EIB which are indicated in the line of the IG/S or should exit the line of the IG/S to the LAN are transmitted. If physically addressed telegrams should not be processed by the IG/S, the option block can be selected. In this setting, it is not possible to send physically addressed telegrams (e.g. during programming) from the line below the IG/S to another line. In the same way, it is possible via the IG/S to prevent any devices being programmed in the line of the IG/S from the LAN (iets). The IG/S itself can still be programmed in this setting. Group telegrams from LAN to EIB filter route (default setting) block The parameter Group telegrams from LAN to EIB defines whether telegrams with group addresses should be filtered, routed or blocked. if the setting filter is selected, the telegrams with group addresses from the LAN to the EIB are filtered in accordance with the filter table. Note: The filter table must be generated by clicking on the button in the Project Design module prior to programming the IG/S. In the setting route, all group telegrams are routed without taking the filter table into account. This setting is only advisable for commissioning and diagnostics purposes. The option route should not be used during normal operation. Group telegrams from EIB to LAN filter route (default setting) block The parameter Group telegrams from EIB to LAN defines whether telegrams with group addresses should be filtered, routed or blocked. If the setting filter is selected, the telegrams with group addresses from the EIB to the LAN are filtered in accordance with the filter table. Note: The filter table must be generated by clicking on the button in the Project Design module prior to programming the IG/S. In the setting route, all group telegrams are routed without taking the filter table into account. This setting is only advisable for commissioning and diagnostics purposes. The option route should not be used during normal operation. If no group telegams should be sent from the EIB to the LAN, the option block must be selected. All the group telegrams from the EIB to the LAN are then blocked without taking the filter table into account. Route telegrams according to priority (default setting) order of receipt If a large number of telegrams are transmitted from the EIB to the LAN or from the LAN to the EIB, telegrams may have to be stored temporarily in the IG/S due to a high bus load. Page 3 of 8 IGS_11_TD_EN_V1-0 CDC 50 03 D0101

, GH Q631 0067 R0001 If telegrams are written to a temporary storage device, it can be defined with this parameter whether the telegrams should be routed in the order they arrived ( order of receipt ) or whether telegrams with a higher priority should be sent ( priority ). IP Address tab The IP Address tab is used to set the IP parameters of the IG/S. Assign IP Address automatically (default setting) manually Project ID Input: 0...55 (default value = 0) The project ID is used to combine several IG/S devices into a group. In addition to the filter table for the telegrams, the IG/S devices evaluate this parameter in telegrams to establish whether the telegrams are intended for them or not. Several different EIB installations can thus be operated on one network without any interaction. If only one EIB installation is operated on the network, the default setting can be retained. Status tab In the default setting ( automatically ), the IG/S expects to be assigned an IP address by a DHCP (dynamic host configuration protocol) server. This server assigns a free IP address to the device on request. If there is no DHCP server available in the network or if the IP address should always be identical, it can also be assigned manually. If the IG/S is set to receive an IP address automatically, the device waits for 30 seconds to be assigned an IP address. If there is no allocation during this period, the IG/S assigns itself an IP address in the range 169.54.xxx.yyy via AutoIP. The settings for the status signals of the IG/S are located in this tab. Send telegram on EIB fault If this parameter is set to, the communication object EIB fault also appears in the object window of the ETS program. If a group address has been assigned to this communication object, the IG/S sends an ON telegram as soon as the connection to the EIB is disrupted. Send telegram on LAN fault IP Address, Subnet Mask, Default Gateway If the option manually is selected for the parameter Assign IP Address, the IP Address, Subnet Mask and Default Gateway are activated and can be permanently assigned. The Subnet Mask defines the class of the network. The Subnet Mask must be set according to the number and structure of the subnetworks. In the simplest case of a small LAN, the Subnet Mask must be set to 55.55.55.0. The parameter Default Gateway indicates the connection point (e.g. the IP address of a router) between networks through which the IP telegrams should be transferred. These gateways are only available in large networks. The setting 0.0.0.0 can be retained for small networks. If this parameter is set to, the communication object LAN fault also appears in the object window of the ETS program. If a group address has been assigned to this communication object, the IG/S sends an ON telegram as soon as the connection to the LAN is disrupted. Page 4 of 8 IGS_11_TD_EN_V1-0 CDC 50 03 D0101

, GH Q631 0067 R0001 Send telegram on 30 V AC fault Bit in Value Error status on If this parameter is set to, the communication object 30 V AC fault also appears in the object window of the ETS program. If a group address has been assigned to this communication object, the IG/S sends an ON telegram as soon as the 30 V AC power supply is disrupted. Send telegram on 1 V DC fault If this parameter is set to, the communication object 1 V DC fault also appears in the object window of the ETS program. If a group address has been assigned to this communication object, the IG/S sends an ON telegram as soon as the 1 V DC power supply is disrupted. Acknowledge faults If this parameter is set to, the communication object Fault acknowledgement also appears in the object window of the ETS program. All fault messages that occur (see above) only remain active until the IG/S receives an ON telegram at the Fault acknowledgement object. The fault messages that are no longer active are then reset. Send status byte on error byte error 0 1 30 V fault 1 1 V fault 4 LAN fault 3 8 EIB fault 4 16 DHCP set but no IP address received from the server 5 3 NTP activated but no time telegrams received from the NTP server 6 64 Queue overflow in IP direction 7 18 Queue overflow in EIB direction Send Status IP Gateway telegram cyclically In the default setting (no), the status of the IP gateway is not sent cyclically. If the option is selected, an additional object Status IP Gateway appears in the object view of the ETS program. The additional parameter Send interval is also visible in the parameter window (see below). Telegram value: 0 : = Status OK, no fault 1 : = one (or several) fault(s) If cyclical sending has been selected, a 0 is sent cyclially when the status is OK. If a fault occurs, a 1 (=fault) is sent once and the cyclical sending is interrupted. A 0 is only sent cyclically again once the fault has been rectified. If this parameter is set to, the IG/S sends the status byte via the communication object Status IP Gateway as soon as an error has occurred. This error can be one of the following errors or a combination of several errors: If the following faults occur, the status is set to 1 : LAN fault EIB fault Page 5 of 8 IGS_11_TD_EN_V-0 CDC 50 03 D0101

, GH Q631 0067 R0001 Send interval 5 s, 10 s, 30 s, 1 min, 5 min, 10 min, 30 min, 1 h, 6 h 1 h, 4 h The parameter Send interval is only visible if the parameter Send Status IP Gateway telegram cyclically has been set to. The most suitable option for the application can be selected from the list of possible intervals. Send time telegram every 1 min, 10 min, 30 min, 1h, 8 h, 1 h, 4 h This parameter indicates at which interval the IG/S should send the time telegram on the EIB if it is operating as a time generator. The entry field is only activated if the parameter IP Gateway is Time Master is set to. Send date telegram every Time tab Parameters for setting the time response of the IG/S on the EIB are located in the Time tab. IP Gateway is Time Master 8 h, 1 h, 4 h This parameter indicates at which interval the IG/S should send the date telegram on the EIB if it is operating as a time generator. The entry field is only activated if the parameter IP Gateway is Time Master is set to. If the option is selected, the IG/S is a time generator on the EIB and sends time and date telegrams itself. Further parameters are activated in this setting. If is selected, the IP address of the LAN time generator must be entered. IP Address LAN Time Master Input: IP address in the format aaa.bbb.ccc.ddd Time zone 1 International Date Line (Western)... + 1 NZST New Zealand Standard Time The time zone can be selected here according to the location of the IP gateway. The default setting + 01: (default value) CEWT Central European Wintertime is suitable for European states. Daylight saving time If the IP gateway has been parameterised as a time generator on the EIB, the IP address of a time generator from which the IP gateway can obtain the time must be entered in the LAN. This time generator must support the NTP (network time protocol) and send the time accordingly. The IG/S then reads the time from the LAN time generator and routes it as a telegram on the EIB. After entering the IP address of the LAN time generator, the communication objects Time and Date are also displayed in the object window of ETS. automatically manually none With this parameter, you can select whether the daylight saving time should be converted automatically (recommended) or entered manually. If you select manually, the following parameters are available. Begin (day, month, time) (of daylight saving time) Select the day, month and time for converting to summertime). Page 6 of 8 IGS_11_TD_EN_V-0 CDC 50 03 D0101

, GH Q631 0067 R0001 End (day, month, time) The IG/S can function as an iets server. The data between the EIB and the (of daylight saving time) Select the day, month and time for reverting back to wintertime. Delta (hours) (of daylight saving time) LAN is exchanged as before. In addition, the programming services are made available for an iets client which is running on a PC on the network. The devices must then be linked as follows. Select here the time difference in hours between wintertime and summertime. Programming with the iets In addition to the standard version of the Engineering Tool Software ETS, there is the so-called Internet ETS (iets). The iets enables the programming of EIB devices from a PC which is only connected to the LAN network. This PC then operates as a client of a server (service provider). To be able to program an EIB device, the iets must be used on the client. The server makes the interface connection to the EIB available. The iets client software is included in the standard ETS program from ETS version 1.3 onwards. A demo licence is also provided with a set time limit. The licence for the iets client must be purchased from the EIBA/Konnex association once the demo version has expired (see www.eiba.com). A more detailed description of programming with the iets and the IG/S can be found in the IG/S product manual. You can also download this manual from the Internet at www.abb.de/eib. LAN IG/S IG/S 1.1.0 1..0 1.1.1 1..1 PC mit iets 1.1. 1.. Programming sequence for several IP gateways EIB/KNX During the initial assignment or modification of the physical address of the IP gateway, the following sequence should be observed during programming: 1. Match the physical address of the RS 3 interface to the topology of the line of the IG/S. (e.g. RS3: 1.1.55, IG/S as line coupler: 1.1.0). Assign the physical address of IG/S no. 1 in the line of the RS 3 interface (e.g. here 1.1.0). 3. Program the physical address of the remote IG/S device (linked with IG/S no. 1 via the LAN). 4. Program the parameters (or application) of the remote IG/S. 5. Program the EIB devices in the line of the remote IG/S. 6. Finally program the parameters (or application) of IG/S no. 1. When modifying the parameters of the IG/S, it is possible to start with step 4. Page 7 of 8 IGS_11_TD_EN_V-0 CDC 50 03 D0101

, GH Q631 0067 R0001 Communication objects No. Type Object name Function 0 1 bit, EIS1 EIB fault Send telegram 1 1 bit, EIS1 LAN fault Send telegram 1 bit, EIS1 30 V AC fault Send telegram 3 1 bit, EIS1 1 V DC fault Send telegram 4 1 bit, EIS1 Fault acknowledge. Receive telegram 5 1 bit, EIS1 Status IP Gateway Send telegram 6 1 byte, EIS6 Status byte IP Gateway Send telegram 7 3 byte, EIS3 Time Send telegram 8 3 byte, EIS4 Date Send telegram Page 8 of 8 IGS_11_TD_EN_V-0 CDC 50 03 D0101