CB TEST CERTIFICATE. LCD monitor. Kuei Shan Hsiang, Tao Yuan Shien TAIWAN. Additional Information on page A V 50/60Hz Cl.

Similar documents
IEC SYSTEM FOR MUTUAL RECOGNITION OF TEST CERTIFICATES FOR ELECTRICAL EQUIPMENT (IECEE) CB SCHEME. Additional Information on page 2

DK UL. Ref. Certif. No. Date: Signature:

IEC SYSTEM FOR MUTUAL RECOGNITION OF TEST CERTIFICATES FOR ELECTRICAL EQUIPMENT (IECEE) CB SCHEME. Additional Information on page 2.

IEC SYSTEM FOR MUTUAL RECOGNITION OF TEST CERTIFICATES FOR ELECTRICAL EQUIPMENT (IECEE) CB SCHEME. Switching Power Supply for Building In

IEC SYSTEM FOR MUTUAL RECOGNITION OF TEST CERTIFICATES FOR ELECTRICAL EQUIPMENT (IECEE) CB SCHEME. Additional Information on page 2

Switching Power Supply DELTA ELECTRONICS INC 3 TUNGYUAN RD CHUNGLI INDUSTRIAL ZONE TAOYUAN COUNTY TAIWAN

CERTIFICAT D'ESSAI OC. Switching Power Supply XP POWER L L C RED HILL AVE, SUITE 100 TUSTIN CA 92780, USA

DECLARATIONS OF CONFORMITY, 3200L, 4200L, 4600L, 5500L, ELO- KIT-ESY, ELO-KIT-ECM3

Ref. Certificate No. KR-KTL-6008 IEC SYSTEM FOR MUTUAL RECOGNITION OF TEST CERTIFICATES FOR ELECTRICAL EQUIPMENT (IECEE) CB SCHEME

Power Supply SL POWER ELECTRONICS CORP BLDG A, 6050 KING DRIVE VENTURA CA 93003, USA

Switching Power Supply Series XP POWER L L C SUITE E DYER RD SANTA ANA CA 92705, USA

TEST REPORT IEC Safety requirements for electrical equipment for measurement, control, and laboratory use Part 1: General requirements

Certificate of Compliance

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

IEC60601_1K. Medical electrical equipment Part 1: General requirements for basic safety and essential performance

Power Supply XP POWER INC SUITE 150, 1241 E DYER RD SANTA ANA CA 92705, USA XP POWER LLC SUITE 150, 1241 E DYER RD SANTA ANA CA 92705, USA

Page 1 of 2. Power Supply SL POWER ELECTRONICS CORP 6050 KING DRIVE, BLDG A VENTURA CA 93003, USA

TEST REPORT IEC Safety of household and similar electrical appliances

Component Switching Power Supply XP POWER LLC SUITE E DYER RD SANTA ANA CA 92705, USA

Switching Power Supply Series XP POWER L L C RED HILL AVE, SUITE 100 TUSTIN CA UNITED STATES

TEST REPORT IEC or ISO Reference Number Title of the IEC or ISO Standard

Model PM01 L L C UNIT D BREA. request

UL TEST REPORT AND PROCEDURE

UL TEST REPORT AND PROCEDURE

UL TEST REPORT AND PROCEDURE

TEST REPORT EN Alarm systems Intrusion systems Part 6: Power supplies

File E Project 91SC COMPONENT POWER SUPPLIES INFORMATION TECHNOLOGY EQUIPMENT INCLUDING ELECTRICAL BUSINESS EQUIPMENT

UL TEST REPORT AND PROCEDURE

E A54-UL 2012-AUGUST-29 XP POWER L L C SUITE E DYER RD SANTA ANA CA 92705

UL TEST REPORT AND PROCEDURE

Test Report S

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

UL TEST REPORT AND PROCEDURE

UL TEST REPORT AND PROCEDURE

Underwriters Laboratories (UL LLC) Safety Certification Report

CB TEST CERTIFICATE CERTIFICAT D'ESSAI OC

Page 1 of 2. Component - Power Supply SL POWER ELECTRONICS CORP 6050 KING DR. BLDG A VENTURA, CA 93003, USA

UL TEST REPORT AND PROCEDURE

UL TEST REPORT AND PROCEDURE

TEST REPORT IEC Part 2: Particular requirements: Section Thirteen d.c. or a.c. supplied electronic controlgear for LED modules

UL TEST REPORT AND PROCEDURE

COVER PAGE FOR TEST REPORT

UL TEST REPORT AND PROCEDURE

CONTENTS 3 EN :2006

UL TEST REPORT AND PROCEDURE

UL TEST REPORT AND PROCEDURE

C E R T I F I C A T E O F C O M P L I A N C E

KUANTECH (SHEN ZHEN) COMPANY LIMITED KSAFD W1UK

UL TEST REPORT AND PROCEDURE

IEC Medical electrical equipment Part 1: General requirements for basic safety and essential performance

Other Aspects: The completed test report includes the following documents: (total page 14)

UL TEST REPORT AND PROCEDURE

UL TEST REPORT AND PROCEDURE

TEST REPORT IEC Self-Ballasted LED-Lamp for general lighting services by voltage > 50V Safety specifications

UL TEST REPORT AND PROCEDURE

UL TEST REPORT AND PROCEDURE

DEMKO CERTIFICATE. Certificate No Page 1/3 Date of Issue Certificate Holder. Manufacturer. Production site

CERTIFICATE OF COMPLIANCE

C E R T I F I C A T E O F C O M P L I A N C E

C E R T I F I C A T E O F C O M P L I A N C E

UL TEST REPORT AND PROCEDURE

Application Switchgear for industrial and advanced commercial applications. U e V AC 240/ (per pole) I cs 7,5 ka

IEC60601_1K. Medical electrical equipment Part 1: General requirements for basic safety and essential performance

C E R T I F I C A T E O F C O M P L I A N C E

SPECIFICATION FOR APPROVAL AC/DC ADAPTOR

AB MSAI Research Labs Pvt. Ltd., 201, IInd Floor, Aggarwal Cyber Plaza, Netaji Subhash Place, Pitampura, Delhi

INSTITUTE OF TESTING AND CERTIFICATION (INDIA) PVT. LTD.

TEST REPORT IEC Information technology equipment - Safety - Part 1: General requirements

CUS150M1 Instruction Manual

Standards Update Notice (SUN) Issued: August 11, 2017

IEC60601_1K. Medical electrical equipment Part 1: General requirements for basic safety and essential performance

C E R T I F I C A T E O F C O M P L I A N C E

Application Switchgear for industrial and advanced commercial applications. U e V AC 240/ (per pole)

ISOMETER isoev425 with coupling device AGH420

SLI 15 Inverter Series Data Sheet 1500 Watt, 1U Compact Inverters

CUSTOMER SPECIFICATION FOR APPROVAL AC/DC ADAPTOR

UL TEST REPORT AND PROCEDURE

REVISION HISTORY REV DESCRIPTION SALES RFS DATE A INITIAL RELEASE MS /20/2011 B UPDATE LABEL: CHANGE CQC PSE NAME TO COGNEX K.K.

PMC. Model Number: Model Number Input Voltage Range Output Voltage Output Current PMC-12V060W1NA Vac ( Vdc) 12Vdc 5.

SPST-NO SPDT DPST-NO DPDT

UL TEST REPORT AND PROCEDURE

UL TEST REPORT AND PROCEDURE

PMC. PMC Panel Mount Power Supply 24V 50W 1 Phase / PMC-24V050W1A. Highlights & Features. Safety Standards. Model Number: General Description

Datasheet. ACF-10 Series AC/DC Power Module 10W

Efficiency (typ.) Load VDC VDC ma ma(typ.) ma(typ.) μf %

ORDERING INFORMATION SEE PAGE 6

MVAD040 Series 40W 2" x 4" AC-DC Power Supply Converter

Electrical Specifications VAC/390 VDC, Universal (Derate from 100% at 100V AC to 77% at 80V AC)

TEK360M series is a fan-less 300W, U-frame, switching power supply with active PFC function for medical application. Rated Output Power.

Electrical Specifications VAC/390 VDC, Universal (Derate from 100% at 100V AC to 95% at 85V AC)

Conveyor Belt Alignment Switches from IDEM

Safety Standards. Model Number:

Model Number Structure

LFMWLP225 SERIES 225 Watt Open Frame Power Supply Measures: 4.00 x 2.00 x 1.00

Electrical Specifications VAC/390 VDC, Universal (Derate from 100% at 100V AC to 77% at 80V AC)

RM22LA32MR Level control relay RM22-L V AC/DC - 2 C/O

IEC Information technology equipment Safety Part 1: General requirements

SLI 15 INVERTER SERIES, 1500 W

TeSys contactors From 115 to 2750 A

Low Voltage Directive (2014/35/EU) Verification No.: T Ratings: I/P: Vac, 50-60Hz, 0.93A

Transcription:

Ref. Certif. No. NO36727/A1/M2 IEC SYSTEM FOR MUTUAL RECOGNITION OF TEST CERTIFICATES FOR ELECTRICAL EQUIMENT (IECEE) CB SCHEME SYSTEME CEI D ACCETATION MUTUELLE DE CERTIFICATS D ESSAIS DES EQUIEMENTS ELECTRIQUES (IECEE) METHODE OC CB TEST CERTIFICATE roduct roduit Name and address of the applicant Nom et adresse du demandeur Name and address of the manufacturer Nom et adresse du fabricant Name and address of the factory Nom et adresse de l usine Note: When more than one factory, please report on page 2 Note: Lorsque il y plus d'une usine, veuillez utiliser la 2 ème page LCD monitor Techview International Technology Inc. 2F, No. 188 Wen Hwa 2 nd Road Kuei Shan Hsiang, Tao Yuan Shien TAIWAN Techview International Technology Inc. 2F, No. 188 Wen Hwa 2 nd Road Kuei Shan Hsiang, Tao Yuan Shien TAIWAN Dong Guan Techview Technology Electronics Limited Yue Yuen Industrial Estate, Huang Jiang Zhen Dong Guan City, Guang Dong rovince.r. CHINA Additional Information on page 2 Ratings and principal characteristics Valeurs nominales et caractéristiques principales Trademark (if any) Marque de fabrique (si elle existe) Model / Type Ref. Ref. De type Additional information (if necessary may also be reported on page 2) Les informations complémentaires (si nécessaire,, peuvent être indiqués sur la 2 ème page A sample of the product was tested and found to be in conformity with Un échantillon de ce produit a été essayé et a été considéré conforme à la As shown in the Test Report Ref. No. which forms part of this Certificate Comme indiqué dans le Rapport d essais numéro de référence qui constitue partie de ce Certificat 1.0A 100-240V 50/60Hz Cl. I, 19" acer AL1923... The dots "." in the model name can be 0 to 9, A to Z, or blank for marketing purpose only. Additional Information on page 2 UBLICATION IEC 60950-1(ed.1) 78144 This certificate replaces certificate NO36727/A1/M1, due to technical modifications. This CB Test Certificate is issued by the National Certification Body Ce Certificat d essai OC est établi par l Organisme National de Certification.O. BOX 73, BLINDERN N-0314 OSLO, NORWAY Date: 2006-12-18 Signature: Hanne Yndestad Certification Department Issued 2003-05 1/1

Ref. Certif. No. NO41501/M1 IEC SYSTEM FOR MUTUAL RECOGNITION OF TEST CERTIFICATES FOR ELECTRICAL EQUIMENT (IECEE) CB SCHEME SYSTEME CEI D ACCETATION MUTUELLE DE CERTIFICATS D ESSAIS DES EQUIEMENTS ELECTRIQUES (IECEE) METHODE OC CB TEST CERTIFICATE roduct roduit Name and address of the applicant Nom et adresse du demandeur Name and address of the manufacturer Nom et adresse du fabricant Name and address of the factory Nom et adresse de l usine Note: When more than one factory, please report on page 2 Note: Lorsque il y plus d'une usine, veuillez utiliser la 2 ème page LCD monitor Techview International Technology Inc. 2F, No. 188 Wen Hwa 2 nd Road Kuei Shan Hsiang, Tao Yuan Shien TAIWAN Techview International Technology Inc. 2F, No. 188 Wen Hwa 2 nd Road Kuei Shan Hsiang, Tao Yuan Shien TAIWAN Dong Guan Techview Technology Electronics Limited Yue Yuen Industrial Estate, Huang Jiang Zhen Dong Guan City, Guang Dong rovince.r. CHINA Additional Information on page 2 Ratings and principal characteristics Valeurs nominales et caractéristiques principales Trademark (if any) Marque de fabrique (si elle existe) Model / Type Ref. Ref. De type Additional information (if necessary may also be reported on page 2) Les informations complémentaires (si nécessaire,, peuvent être indiqués sur la 2 ème page A sample of the product was tested and found to be in conformity with Un échantillon de ce produit a été essayé et a été considéré conforme à la As shown in the Test Report Ref. No. which forms part of this Certificate Comme indiqué dans le Rapport d essais numéro de référence qui constitue partie de ce Certificat 1.0A 100-240V 50/60Hz Cl. I, 19" acer X191. The dots "." in the model name can be 0 to 9, A to Z, or blank for marketing purpose only. Additional Information on page 2 UBLICATION IEC 60950-1(ed.1) 78144 This certificate replaces certificate NO41501, due to technical modifications. This CB Test Certificate is issued by the National Certification Body Ce Certificat d essai OC est établi par l Organisme National de Certification.O. BOX 73, BLINDERN N-0314 OSLO, NORWAY Date: 2006-12-18 Signature: Hanne Yndestad Certification Department Issued 2003-05 1/1

- age 1 of 18 - Test Report issued under the responsibility of: www.nemko.com Amendment to Test Report This Amendment is valid only together with the main Test Report Report Reference No....: 78144 Main Report Reference No....: 57110 Tested by (printed name and signature)...: Andy Lee Approved by (printed name and signature)...: Wilson Wang Date of issue...: December 18, 2006 Testing Laboratory Name...: Nemko Taiwan hone: (+886) 2 8797 8790 Address...: 5Fl, No. 409, Section 2, Tiding Blvd., Neihu, Taipei 114, Taiwan Testing location...: CBTL CCATL SMT TM Address...: Same as above Applicant's Name...: Techview International Technology Inc. Address...: 2F, No. 188 Wen Hwa 2 nd Rd., Kuei Shan Hsiang, Tao Yuan Shien Taiwan Test specification Standard...: IEC 60950-1:2001 and/or EN 60950-1:2001, A11:2004 First Edition Test procedure...: CB/CCA scheme Non-standard test method...: N/A Test Report Form No....: IECEN60950_1B TRF originator... : SGS Fimko Ltd Master TRF... : dated 2003-03 Copyright 2002 IEC System for Conformity Testing and Certification of Electrical Equipment (IECEE), Geneva, Switzerland. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the IECEE is acknowledged as copyright owner and source of the material. IECEE takes no responsibility for and will not assume liability for damages resulting from the reader s interpretation of the reproduced material due to its placement and context. Test item description...: LCD monitor Trademark...: 1) Techview 2) acer Manufacturer...: Same as applicant Model and/or type reference...: 1) L9TB 2) AL1923... ; X191. (The dots. in the model name can be 0 to 9, A to Z or blank for marketing purpose only.) Serial number...: Test sample without serial numbers Rating(s)...: 1.0A 100-240V 50/60Hz Rev. 2006-03 KS This Amendment to Test Report, when bearing the Nemko name and logo is only valid when issued by a Nemko laboratory, or by a laboratory having special agreement with Nemko.

- age 2 of 18 - Name and address of production-sites (Factories): Dong Guan Techview Technology Electronics Limited Yue Yuen Industrial Estate, Huang Jiang Zhen, Dong Guan City, Guang Dong rovince,. R. China List of attachments: 1. hotos (2 pages). 2. ower supply unit (SU) CB test report: Hipro Electronics Co., Ltd., model H-LC043K..., Nemko CB certificate No. NO40213, CB test report ref. No.: 71150. TDK Xiamen Co., Ltd., model XAD376ARyy, TUV CB certificate No. JTUV-016141, CB test report ref. No.: 11008185 001. Delta Electronics, Inc., model EAD-45AF B, TUV CB certificate No. JTUV-017020, CB test report ref. No.: 11008908 001. roject history: Nemko Report/ Order No.: Modification to the appliances: 57110 Main test report. 72100 - Change model name from AL1923 to AL1923... - Added alternative panel source. - Change applicant and manufacture address. 76478 - Added alternative model designation X191. and color of enclsoure. 76832 Issue GS certificates for models L9TB, AL1923... and X191. 78144 - Added power board sources, panel source and mylar sheet. - Alternate internal shielding. - Alternate color (Silver and Black) of enclsoure. - DVI and Audio function will be optional. Changes/ Modifications in clause(s): 1.5 and 1.7 1.7 1.5, 1.6, 2.4, 2.5, 2.6, 2.9, 2.10, 4.2, 4.5, 4.6, 5.1, 5.2 and 5.3

- age 3 of 18 - Test case verdicts Test case does not apply to the test object : Test item does meet the requirement... : Test item does not meet the requirement.. : Testing N(/A) (ass) F(ail) Date of receipt of test item... : December, 2006 Date(s) of performance of test... : December, 2006 General remarks This report is not valid as a CB Test Report unless appended by an approved CB Testing Laboratory and appended to a CB Test Certificate issued by an NCB in accordance with IECEE 02. The test result presented in this report relate only to the object(s) tested. This report shall not be reproduced, except in full, without the written approval of the Issuing testing laboratory. (see attachment #)" refers to additional information appended to the report. "(see appended table)" refers to a table appended to the report. Throughout this report a comma (point) is used as the decimal separator. General product information: This Amendment shall always be enclosed with main Test Report, report/order no. 57110 and its amendments, report/order no. 72100, 76478 and 76832. The changes of concern: - Added power board sources, panel sources and mylar sheet, refer to table 1.5.1 for details. - Alternate internal shielding, refer to photos for details. - Alternate color (Silver and Black) of enclosure, refer to photos for details. - DVI and Audio function will be optional. Load condition: Full white display with max. brightness and contrast, horizontal and vertical deflection, picture provided from a signal generator. Audio function operated at maximum volume output.

- age 4 of 18 - IEC 60950-1 / EN 60950-1 Clause Requirement Test Result Remark Verdict 1.5 Components 1.5.1 General Comply with IEC 60950 or relevant component standard (See appended table 1.5.1.) 1.5.2 Evaluation and testing of components Certified components are used in accordance with their ratings, certifications and they comply with applicable parts of this standard. Components not certified are used in accordance with their ratings and they comply with applicable parts of IEC 60950-1 and the relevant component standard. Components, for which no relevant IEC-standard exists, have been tested under the conditions occurring in the equipment, using applicable parts of IEC 60950-1. 1.6 ower interface 1.6.2 Input current (see appended table 1.6.2) 2.4 Limited current circuits 2.4.1 General requirements Refer to separated SU report. 2.4.2 Limit values Frequency (Hz)... : Measured current (ma)... : Measured voltage (V)... : Measured capacitance (μf)... : 2.4.3 Connection of limited current circuits to other circuits Refer to separated SU report. 2.5 Limited power sources Inherently limited output N Impedance limited output N Overcurrent protective device limited output Refer to separated SU report.

- age 5 of 18 - IEC 60950-1 / EN 60950-1 Clause Requirement Test Result Remark Verdict Regulating network limited output under normal operating and single fault condition Regulating network limited output under normal operating conditions and overcurrent protective device limited output under single fault condition Output voltage (V), output current (A), apparent power (VA)...: Current rating of overcurrent protective device (A) Refer to separated SU report. Refer to separated SU report. Refer to separated SU report. N 2.6 rovisions for earthing and bonding 2.6.3.4 Resistance (Ω) of earthing conductors and their From the appliance inlet to terminations, test current (A)... : - Chassis: U = 0.3V 12mΩ (for 25A/1 min.) U = 0.48V 12mΩ (for 40A/2 min.) 2.9 Electrical insulation 2.9.1 roperties of insulating materials Neither natural rubber, materials N containing asbestos nor hygroscopic materials are used as insulation. No driving belts or couplings used. 2.9.2 Humidity conditioning Humidity treatment performed at 40 C for 120 hrs and 25 C for 48 hrs. Humidity (%)... : 91-95% Temperature ( C)... : 25 and 40 C 2.9.3 Grade of insulation Insulation is considered to be functional, basic, supplementary, reinforced or double insulation. 2.10 Clearances, creepage distances and distances through insulation 2.10.1 General Considered, see the following clauses: 2.10.2 Determination of working voltage Considered. 2.10.3 Clearances Ref. to separated SU report and table 2.10.3 & 2.10.4. 2.10.3.1 General Refer below:

- age 6 of 18 - IEC 60950-1 / EN 60950-1 Clause Requirement Test Result Remark Verdict 2.10.3.2 Clearances in primary circuit Ref. to separated SU report and table 2.10.3 & 2.10.4 2.10.3.3 Clearances in secondary circuits Refer to separated SU report. 2.10.3.4 Measurement of transient voltage levels Measurement not relevant. N 2.10.4 Creepage distances Ref. to separated SU report and table 2.10.3 & 2.10.4. CTI tests... : CTI rating for all material of minimum 100. 2.10.5 Solid insulation Refer below: 2.10.5.1 Minimum distance through insulation Ref. to separated SU report. 2.10.5.2 Thin sheet material see appended table 2.10.5 Number of layers (pcs)... : Electric strength test 4.2 Mechanical strength 4.2.1 General Complies with the requirement also after tests described below are applied. 4.2.3 Steady force test, 30 N No hazard. Test is performed at enclosure of power supply. 4.5 Thermal requirements 4.5.1 Maximum temperatures (see appended table 4.5) Normal load condition per Annex L... : Rated load with continuous operation. N 4.6 Openings in enclosures

- age 7 of 18 - IEC 60950-1 / EN 60950-1 Clause Requirement Test Result Remark Verdict 4.6.1 Top and side openings Fire enclosure (metal): Top: A. 1.5 mm in diameter. B. rovided one opening, measures 21.9 x 1.4mm (baffled by mylar sheet, min. V-1) C. rovided one opening, measures 79.9 x 15.1 mm (secondary control board under this opening, which is supplied by L..S.) D. rovided one opening, measures 250 x 6.3 mm (power supply part baffled by mylar sheet; Inverter under this openings, which is supplied by L..S.) Left side: A. 2.4 mm in diameter. B. rovided one opening (DC/AC connector used), measures 20.3 x 7.6 mm. (which is supplied by L..S.) C. rovided one opening (DC/AC connector used), measures 21 x 7.6 mm. (which is supplied by L..S.) Right side: rovided one opening (control board connector used), measures 46.5 x 11 mm. (which is supplied by L..S.) Rear: A. 2.9mm in diameter. B. Max. 29.5 x 11.9 mm (located on control board, which is supplied by L..S.). Hazardous parts are not located within 5 vertical projection of openings. Dimensions (mm)... :

- age 8 of 18 - IEC 60950-1 / EN 60950-1 Clause Requirement Test Result Remark Verdict 4.6.2 Bottoms of fire enclosures Fire enclosure construction is considered to comply with the requirements. Fire enclosure (metal): A. 1.5 mm in diameter and spacing of holes centre to centre is 5.5 mm which complies with requirement of table 4C. B. rovided one opening, measures 279 x 6.3 mm (power supply part baffled by mylar sheet; Inverter under these openings, which is supplied by L..S.) Construction of the bottom... : 5 ELECTRICAL REQUIREMENTS AND SIMULATED ABNORMAL CONDITIONS 5.1 Touch current and protective conductor current 5.1.1 General Test conducted in accordance with 5.1.2 to 5.1.7. 5.1.2 Equipment under test (EUT) No interconnected equipment or multiple power sources. 5.1.3 Test circuit Tested for connection to IT power distribution system (also relevant for TN or TT power distribution system). 5.1.4 Application of measuring instrument Measuring instrument D1 is used. 5.1.5 Test procedure Considered 5.1.6 Test measurements Measuring instrument D1 is used. Test voltage (V)...: 264V Measured touch current (ma)...: See appended table 5.1. Max. allowed touch current (ma)...: 0.25 and 3.5 Measured protective conductor current (ma)...: Max. allowed protective conductor current (ma) : N N 5.2 Electric strength 5.2.1 General (see appended table 5.2) 5.2.2 Test procedure (see appended table 5.2)

- age 9 of 18 - IEC 60950-1 / EN 60950-1 Clause Requirement Test Result Remark Verdict 5.3 Abnormal operating and fault conditions 5.3.1 rotection against overload and abnormal operation 5.3.8 Compliance criteria for abnormal operating and fault conditions (see appended table 5.3) No fire or molten metal occurred and no deformation of enclosure during the tests. No reduction of clearance and creepage distances. Electric strength test is made on basic, supplementary and reinforced insulation.

- age 10 of 18-1.5.1 TABLE: list of critical components object/part No. External decorative enclosure ower supply (SU) manufacturer/ trademark type/model technical data standard mark(s) of conformity 1 ) Various HB minimum. UL94 UL Delta EAD-45AF B Class I, I/: 1500mA, 100-240V, 50-60Hz. O/: 3.0A max. /+5.2V, 0.4A max. /+12.0V, CN201-CN204: 720Vrms/8mA max. (each of the four outputs of the DC/AC inverter) Hipro TDK H-LC043K... (The dots. in the model name can be 0 to 9, A to Z, or blank for marketing purpose only.) XAD376ARyy (y can be any alphanumeric character or blank) Class I, I/: 1.1A, 100-240V, 50-60Hz. DC output: 3.0A max. /+5.0V, 0.4A max. /+12.0V, AC output: 8.0mA max., 720Vac (CN1, CN2, CN3, CN4) Class I, I/: 1.2A, 100-240V, 50-60Hz. O/: DC 3.0A max. /+5V, 0.4A max. /+12.7V, AC 720Vac, 8.0mA (CN102-CN105) LCD anel LG LM190E03 19 TFT, glass is min. 0.4 mm thickness Mylar (between power board and bottom chassis) 1) AUO M190EN04 19 TFT, glass is min. 0.4 mm thickness Various supplementary information: Min. V-1, 77.2mm by 140.2mm, 0.4mm thickness IEC60950-1:2001 IEC60950-1 (ed.1) IEC60950-1:2001 UL94 CB (by TUV, refer certificate No. JTUV- 017020) CB (by Nemko, refer certificate No. NO 40213) CB (by TUV, refer certificate No. NO. JTUV- 016141) Test in equip. Test in equip. 1 ) an asterisk indicates a mark which assures the agreed level of surveillance 1) Only used together with power supply of Delta, type EAD-45AF B or Hipro, type H-LC043K... or TDK, type XAD376ARyy. UL

- age 11 of 18-1.6.2 TABLE: electrical data (in normal conditions) fuse # Irated (A) U (V) (W) I (A) Ifuse (A) condition/status For power supply Delta, type EAD-45AF B F101 -- 90/50Hz 38.9 0.686 0.686 Max. normal load F101 -- 90/60Hz 38.6 0.689 0.689 Max. normal load F101 1 100/50Hz 38.1 0.629 0.629 Max. normal load F101 1 100/60Hz 38.0 0.628 0.628 Max. normal load F101 1 240/50Hz 38.7 0.299 0.299 Max. normal load F101 1 240/60Hz 38.4 0.296 0.296 Max. normal load F101 -- 254/50Hz 38.4 0.285 0.285 Max. normal load F101 -- 254/60Hz 38.5 0.284 0.284 Max. normal load F101 -- 264/50Hz 38.4 0.276 0.276 Max. normal load F101 -- 264/60Hz 38.2 0.275 0.275 Max. normal load For power supply Hipro, type H-LC043K... F1 -- 90/50Hz 37.6 0.655 0.655 Max. normal load F1 -- 90/60Hz 37.3 0.657 0.657 Max. normal load F1 1 100/50Hz 36.9 0.60 0.60 Max. normal load F1 1 100/60Hz 36.9 0.604 0.604 Max. normal load F1 1 240/50Hz 37.5 0.290 0.290 Max. normal load F1 1 240/60Hz 37.3 0.286 0.286 Max. normal load F1 -- 254/50Hz 37.5 0.276 0.276 Max. normal load F1 -- 254/60Hz 37.3 0.275 0.275 Max. normal load F1 -- 264/50Hz 37.4 0.269 0.269 Max. normal load F1 -- 264/60Hz 37.3 0.267 0.267 Max. normal load For power supply TDK, type XAD376ARyy F1 -- 90/50Hz 37.8 0.666 0.666 Max. normal load F1 -- 90/60Hz 37.7 0.665 0.665 Max. normal load F1 1 100/50Hz 37.3 0.609 0.609 Max. normal load F1 1 100/60Hz 37.3 0.614 0.614 Max. normal load F1 1 240/50Hz 37.3 0.298 0.298 Max. normal load F1 1 240/60Hz 37.1 0.296 0.296 Max. normal load F1 -- 254/50Hz 37.1 0.285 0.285 Max. normal load F1 -- 254/60Hz 37.0 0.284 0.284 Max. normal load

- age 12 of 18 - fuse # Irated (A) U (V) (W) I (A) Ifuse (A) condition/status F1 -- 264/50Hz 37.0 0.277 0.277 Max. normal load F1 -- 264/60Hz 36.9 0.276 0.276 Max. normal load supplementary information: 2.5 TABLE: limited power sources I sc (A) VA Meas. Limit Meas. Limit supplementary information: S-c=Short circuit, O-c=Open circuit Refer to separated SU report. 2.10.3 and 2.10.4 TABLE: clearance and creepage distance measurements clearance cl and creepage distance dcr at/of: Basic: rimary components (SU) case (GND) supplementary information: Refer to separated SU test report. Up U r.m.s. required cl cl required dcr (V) (V) (mm) (mm) dcr (mm) (mm) 339 240 2.0 3.4 2.5 3.4 2.10.5 TABLE: distance through insulation measurements distance through insulation di at/of: Basic: Mylar sheet between SU board (cover primary trace and primary component side) and case supplementary information: Up (V) test voltage (V) required di (mm) di (mm) 544Vp 1834V ac 1 layer 1 layer

- age 13 of 18-4.5 TABLE: maximum temperatures test voltage (V) : 90V 264V maximum temperature T of part/at:: T ( C) allowed T max ( C) For power supply Delta, type EAD-45AF B T101 coil (power & inverter) 93.1 94.6 110 T101 core (power & inverter) 88.7 90.3 110 Body of IC102 (power & inverter) 82.1 82.2 100 Body of CY101 (power & inverter) 79.8 81.0 125 FL102 coil (power & inverter) 69.3 64.5 120 FL101 coil (power & inverter) 68.0 63.5 110 Body of C101 (power & inverter) 75.3 71.6 105 CB near BD101 (power & inverter) 75.3 70.2 130 CB near Q101 (power & inverter) 82.6 81.9 130 CB near CR151 (power & inverter) 96.6 97.2 130 T201 coil (power & inverter) 112.3 111.5 120 T201 core (power & inverter) 101.4 101.2 120 Body of C224 (power & inverter) 83.5 83.1 -- Inlet near L 53.5 52.6 70 CB near U4 (main board) 73.0 73.3 105 Internal enclosure near power 55.1 55.6 -- External enclosure near power 48.7 48.4 95 anel 56.3 55.9 95 Stand by switch 42.9 42.4 95 Ambient 40.0 40.0 --

- age 14 of 18-4.5 TABLE: maximum temperatures (Continued) test voltage (V) : 90V 264V maximum temperature T of part/at:: T ( C) allowed T max ( C) For power supply Hipro, type H-LC043K... T1 coil (power & inverter) 98.0 99.6 110 T1 core (power & inverter) 93.3 94.7 110 Body of C1 (power & inverter) 86.8 83.6 100 Body of CY1 (power & inverter) 83.5 82.6 85 CB near BD1 (power & inverter) 85.9 73.4 130 NF1 coil(power & inverter) 82.7 66.3 120 Body of C1 (power & inverter) 82.4 75.9 85 CB near Q1 (power & inverter) 90.1 81.9 130 CB near D101 & D102 (power & inverter) 102.7 103.3 130 Inlet near L (power & inverter) 54.3 53.0 70 T31 coil (power & inverter) 119.4 119.1 120 T31 core (power & inverter) 97.8 96.7 120 CB near IC31 (power & inverter) 81.4 80.4 130 CB near U4 (main board) 73.2 73.7 105 Internal enclosure near power 55.1 55.3 -- External enclosure near power 48.1 48.3 95 anel 56.6 57.1 95 Standby switch 41.3 41.0 95 Ambient 40.0 40.0 --

- age 15 of 18-4.5 TABLE: maximum temperatures (Continued) test voltage (V) : 90V 264V maximum temperature T of part/at:: T ( C) allowed T max ( C) For power supply TDK, type XAD376ARyy T1 coil (power & inverter) 99.5 101.7 110 T1 core (power & inverter) 96.3 99.0 110 Body of IC2 (power & inverter) 89.7 90.1 100 CB near CR1 (power & inverter) 76.9 65.2 105 L1 (power & inverter) 80.6 66.3 120 Body of C4 (power & inverter) 79.5 72.5 105 CB near Q1 (power & inverter) 96.4 97.4 105 Inlet near L (power & inverter) 56.6 54.0 70 T101 coil (power & inverter) 111.7 110.5 120 T101 core (power & inverter) 91.4 90.2 120 CB near IC101 (power & inverter) 100.7 99.4 105 CB near U4 (main board) 73.6 72.8 105 Internal enclosure near power 56.8 56.1 -- External enclosure near power 49.4 48.8 95 anel 56.7 55.8 95 Stand by switch 41.4 42.0 95 Ambient 40.0 40.0 -- supplementary information: Having a specified maximum ambient temperature of 40 C. Temperature limits include less 10K for thermocouple measurement method. Testing conducted according to 1.4.12. Tested with standard base.

- age 16 of 18-5.1.6 5.1.8 TABLE: touch current measurement Measured between: Measured (ma) For power supply Delta, type EAD-45AF B Line (hase 1) rotective Earthing (signal connector) Neutral (hase 2) rotective Earthing (signal connector) Limit (ma) 0.17 3.5 Fuse in 0.17 3.5 Fuse in Line Enclosure (foil) 0.01 0.25 Fuse in Neutral Enclosure (foil) 0.01 0.25 Fuse in Line Secondary connector 0.15 0.25 Fuse in Neutral Secondary connector 0.15 0.25 Fuse in For power supply Hipro, type H-LC043K... Line (hase 1) rotective Earthing (signal connector) Neutral (hase 2) rotective Earthing (signal connector) 0.54 3.5 Fuse in 0.54 3.5 Fuse in Line Enclosure (foil) 0.01 0.25 Fuse in Neutral Enclosure (foil) 0.01 0.25 Fuse in Line Secondary connector 0.13 0.25 Fuse in Neutral Secondary connector 0.13 0.25 Fuse in For power supply TDK, type XAD376ARyy Line (hase 1) rotective Earthing (signal connector) Neutral (hase 2) rotective Earthing (signal connector) 0.572 3.5 Fuse in 0.568 3.5 Fuse in Line Enclosure (foil) 0.01 0.25 Fuse in Neutral Enclosure (foil) 0.01 0.25 Fuse in Line Secondary connector 0.18 0.25 Fuse in Neutral Secondary connector 0.18 0.25 Fuse in supplementary information: Comments/conditions

- age 17 of 18-5.2 TABLE: electric strength tests, impulse tests and voltage surge tests test voltage applied between: For power supply Delta, type EAD-45AF B test voltage (V) a.c. / d.c. breakdown Yes / No Reinforced: rimary - Secondary 4242 Vdc / 60s No Basic: rimary - rotective Earth 2505 Vdc / 60s No Reinforced: rimary Enclosure with foil 4242 Vdc / 60s No For power supply Hipro, type H-LC043K... Reinforced: rimary - Secondary 4242 Vdc / 60s No Basic: rimary - rotective Earth 2461 Vdc / 60s No Reinforced: rimary Enclosure with foil 4242 Vdc / 60s No For power supply TDK, type XAD376ARyy Reinforced: rimary - Secondary 4242 Vdc / 60s No Basic: rimary - rotective Earth 2505 Vdc / 60s No Reinforced: rimary Enclosure with foil 4242 Vdc / 60s No supplementary information

- age 18 of 18-5.3 TABLE: fault condition tests component No. Ventilation openings (for power supply Delta, type EAD- 45AF B) Ventilation openings (for power supply Hipro, type H- LC043K...) Ventilation openings (for power supply TDK, type XAD376A Ryy) ambient temperature ( C)...: See below: model/type of power supply...: manufacturer of power supply...: rated markings of power supply...: fault test voltage (V) test time fuse No. fuse current (A) result Blocked 240 2.5 hrs -- 0.299 Max. temp. measured on T101 coil = 81.1 C, ambient 21.9 C, no hazards. Blocked 240 2.5 hrs -- 0.290 Max. temp. measured on T1 coil = 86.4 C, ambient 22.2 C, no hazards. Blocked 240 4.5 hrs -- 0.298 Max. temp. measured on T1 coil = 91.0 C, ambient 24.0 C, no hazards. s-c=short circuit, o-c=open circuit, o-l=overload

- age 1 of 2 - hotos www.nemko.com Order No. 78144

- age 2 of 2 - hotos www.nemko.com Order No. 78144