LON bus communication devices 1MRS MBG Page 1 Issued: April 1999 Status: New Data subject to change without notice

Similar documents
SREDU Double Connection Option Card for Lon Star Coupler RER 111

SPA-ZC 200/SPA-ZC 202 IEC /SPA-gateway Modules. Installation Manual

Voltage regulator. SPAU 341 C 1MRS MBG Issued: July 1998 Status: Revised Version: C/ Data subject to change without notice

SPA-ZC 17. Bus connection module SPA-ZC 17. User s manual and Technical description. Tx SC Rx BB BM MB MM SPA / RS 485 POWER SLAVE 1 MASTER 0

Residual overvoltage relay

Synchro-check relay. Application

Earth-fault Relay SPAJ 110 C. Product Guide

Sensitive definite time or inverse time earth-fault stage for back-up residual earthfault

Sensitive Earth-fault Relay SPAJ 111 C. Product Guide

Feeder protection relay

Feeder protection relay SPAA 121 C. Product Guide

LON bus LonWorks Network in Protection and Control Systems. User s manual and Technical description

Data communication and reporting unit

High impedance protection relay

Data communication and reporting unit

RER 123 Bus Connection Module. Technical Description

Combined Overcurrent and Earth-fault Relay SPAJ 140 C. Product Guide

SPA-ZC 302. Profibus-DPV1/SPA Gateway. Product Guide. spa-zc302_rightco300

Combined Overcurrent and Earth-fault Relay SPAJ 141 C. Product Guide

Feeder protection relay SPAA 341 C. Product Guide

SMS 510, CAP 505 LON Gateways Configuration Configuration Guide

Arc protection relay. Features Three-phase overcurrent function. Application

Relay Product Engineering Tools

Communication Gateway COM 500. Product Guide

Communication Gateway COM 610. Product Guide

High Impedance Protection Relay SPAE010, SPAE011. Product Guide

Arc protection relay. Features Three-phase overcurrent function. Application

Relay configuration and setting tool package

Communicate IT Software module DR-COM. Buyer s Guide

Next Generation Intelligent Lon EIA/ANSI 709 Router Datasheet

Directional or Non-Directional Earth-Fault Relay REJ 527. Product Guide

SPAA 341 C Feeder protection relay

MicroSCADA Pro SYS Connecting LONWORKS Devices

Feeder Protection Relay REF 610. Product Guide

OHIO SEMITRONICS, INC. AC MULTIFUNCTION PROGRAMMABLE TRANSDUCERS & -1000L

ABB Drives. User s Manual. Digital I/O Extension Module RDIO-01

Power Products. Protection and Control IED Manager PCM600 Product Guide

Protection and Control IED Manager PCM600 Product Guide

Relay setting toolbox

Motor Protection Relay REM 610. Product Guide

ABB Drives. User s Manual Modbus Adapter Module FMBA-01

Relion 650 series. 650 series 2.1 IEC LON Communication protocol manual

Power Products. Station Automation COM600 Product Guide

CAP 505 Relay Product Engineering Tools Installation and Commissioning Guide

T M. IRDH375 Series. Digital Ground Fault Monitor / Ground Detector For Ungrounded (Floating) AC/DC Systems. Technical Bulletin NAE / 09.

Switching module for AC V and up to three load stages, with manual switching

MV Process Application Library LIB 510. Product Guide

Communication with EuroProt-IED Multifunctional intelligent devices

Protection and Control IED Manager PCM600 Product Guide

General characteristics of C-type relay modules

SPA-ZC 100/SPA-ZC 102 LON /SPA Gateway. Programming Manual

ABB Drives. User s Manual I/O Module Adapter AIMA-01

PCAN-Repeater DR CAN Repeater for the Decoupling of Bus Segments. User Manual. Document version ( )

ABB Drives. User s Manual. Analogue I/O Extension Module RAIO-01

Controller module. Brief description. Features. Block structure. Page 1/7. Data Sheet

NodeBuilder 3.1 Development Tool Model 10020

SYS 500 Installation 1MRS MEN. Notice 1. Notice 2. Notice 3. Trademarks

Mounting kits for space-saving mounting in racks and cubicles and on walls IP54 protected mounting capability in cubicles

Relion 611 series. 611 series Type Test Certificate

DGBV-EP DIGITAL GENERATOR AND GENERATOR-TRANSFORMER UNIT PROTECTION. Field of application

LNT 505 Installation and Commissioning Manual

AC 800M for Compact Product Suite Outline of all modules

Power Products. Station Automation COM600 Product Guide

Accessories / 7XV5461

INDUSTRIAL 1000BASE-T TO 1000BASE-X MEDIA CONVERTERS. KCD-400 Series. Installation Guide

Relion 610 series. Voltage Protection REU610 Product Guide

ISOMETER isopv with coupling device AGH-PV

REM 543 Machine Terminal. User s Guide for Modbus Configurations

Decentralised operating and monitoring systems

AIDON PRODUCT CATALOG

ABB Drives. User s Manual. Modbus Adapter Module RMBA-01

Easylon Network Components

Impulse switching module

ekorrps MULTIFUNCTIONAL PROTECTION UNIT CONFIGURATION AND GENERAL CHARACTERISTICS LIB

Room unit with PPS2 interface

MCX08M2 Programmable controller

TAC Xenta 301. Controller, Freely Programmable

A2000 Multifunctional Power Meter

Operating and mounting instructions

MC 11 EB-2 Power supply cabinet with external bus, AC version

Relion 630 series. Load-shedding controller PML630 High performing load-shedding solution for industrial and utility power networks

Catalog. Arc Guard System TM TVOC-2

Accessories / 7XV5662

Ethernet Adapter. Modbus/TCP Brigde. Installation and Commissioning Manual

Product Details. Contents. Features and Mounting Options for SUNNY STRING-MONITOR SSM24-11

Protection Relay RE_ 610. Installation Manual

6 / 8 Port Gigabit Ethernet Switch with PoE+ optional with 2x SFP Slots

Du line. Dupline Field- and Installationbus Dupline Ethernet Modbus/TCP Gateway Type G G Type Selection

Relion 610 series. Feeder Protection REF610 Product Guide

3RA13, 3RA14 Contactor Assemblies

iswitch imotor Compact QR

SOLPLUS Inverters SOLPLUS 25 55

Wayside Control Systems Products

CFO100 Series. User Manual CRT141 & CRR141. CFO141 User Manual, , rev001

Easy Analog RNB130. Technical Information. Primary switched-mode power supply

IRI1-ES Sensitive Earth Fault Current Relay. Manual IRI1-ES (Revision A)

TOSHIBA CMOS Digital Integrated Circuit Silicon Monolithic TMPN3120FE3MG

Overview. Seen as an extension of the main HVAC controller when configuring, allowing you to save engineering time.

Overview. Seen as an extension of the main HVAC controller when configuring, allowing you to save engineering time.

Controller module. Brief description. Features. Block structure. Data Sheet Page 1/7

Transcription:

LON bus communication devices Page 1 Issued: April 1999 Status: New Data subject to change without notice Features The LonWorks Network is an open system adapted for various application areas Peer-to-peer protocol which allows all the networked devices to communicate with each other Powerful LonTalk protocol for substation information interchange in LonWorks networks Nodes identified by their own subnet and node number Max. 255 subnets and 127 nodes per subnet High immunity to electric and electromagnetic interference due to fibre-optic transfer media The protocol complies with the reference model for open system interconnection (OSI) by ISO Maximum network speed 1.25 Mbit/s in ABB substations with fibre-optic media Member of ABB s Distribution Automation system and ABB s Panorama concept Application Due to the increasing amount of data transferred within and from modern substations the communication feature of the protection and control equipment is being utilized more and more. This requires fast and reliable operation of the information transfer media to be used for communication. For this reason a new communication protocol, i.e. the LON protocol, has been added to our concept. Design The LonTalk protocol used in LonWorks networks, is designed to fulfill the requirements of a great variety of industrial applications. The protocol complies with the reference model for open systems interconnection (OSI) developed by the International Standard Organization (ISO). The speed of the network depends on the medium used and the transceiver design. The fibre-optic media used with our protection and control devices allow the maximum speed of 1.25 Mbit/s to be used. The protocol is a peer-to-peer protocol which allows all the devices connected to the network to communicate with each other. The

Page 2 Design (cont d) nodes are identified by their own subnet and node number (max. 255 subnets and 127 nodes per subnet). The LON bus is used in a similar way as ABB s original SPA bus, i.e. to link the different parts of the substation protection and control system to each other. Measured values, status data and event information are spontaneously sent to the higher-level devices. When required, these higher-level devices are able to read and write memorized values, setting values and other parameter data. In addition, the LON bus allows the bay level devices to communicate with each other and, thus, provide interlocking information between the bay controllers and blocking signals between the protection relays. The LonTalk protocol supports two types of application layer objects: network variables and explicit messages. The network variables are used to deliver short messages such as measured values, status information and interlocking/blocking signals, whereas explicit messages are used for longer messages, for instance, events and explicit read and write messages, to access device data. SPA-bus messages can also be sent transparently in the form of explicit messages, for the purpose of transferring parameter data to devices communicating over the SPA bus. Our protective relays and control units which are equipped with a SPA-bus interface can be connected to the LON bus using the LON/ SPA gateway module SPA-ZC 100. An SRIO 1000M unit connects to the LON bus through an SLTA (Serial LonTalk Adapter) card in the star coupler. The RE_ 500 series devices have built-in LON support. Lon Star-Coupler 111 The Lon Star-Coupler 111 is used to interconnect the nodes in a LonWorks network. It offers a variety of configuration options. As standard the 111 unit provides the following: Single or double auxiliary power supply units with input voltage ranges 80 265 V ac/dc or 18 80 V dc Input/Output (I/O) Card Mother Board 9 slot placements for option cards The following five option cards are available: The Fibre-Optic Option Card SFIBER MM provides three fibre-optic transceiver pairs for the interconnection of bay level devices, connection between two 111 modules equipped with Fibre-Optic Option Cards or between a 111 module and higher level devices e.g. MicroSCADA. The RS-485 Option Card SRS485 MM provides a means of connecting LON bus devices using the RS-485 interface to the LonWorks network. The card also comprises a fibre-optic transceiver pair. The SLTA Option Card SSLTA MM provides the interconnection between higher level devices (e.g. monitoring terminals, PC, etc.) and the LonWorks network. It can also provide the interconnection between 111 modules by using the fibre-optic transceiver pair. The Router Option Card, SROUT MM, provides connection to devices using twisted pair (TP/XF-78 or TP/XF-1250) and / or using fibre-optic transceiver pairs. It also provides a means by which an overall system can be divided into multiple subsystems. The Double Connection Option Card SREDU MM provides a means for connecting devices together by using double connections. This method enables the use of two fibre-optic transceiver pairs to connect to any device supporting double connection. In the event of a fault in one fibreoptic connection, this connection is still able to receive and transmit data to devices. Bus connection module 103 The 103 (104) is used for connecting REx 53x devices to the LON bus. The 103 is also used when the REx 53x devices are connected to the SPA bus. The 103 module comprises one 9-pin D type RS 485 connector for the connection to the device and one glass or plastic transceiver pair for the bus connection. The 103 is powered from the device to which it is connected.

Page 3 Interface card 109 The 109 is the PCLTA card which is used to interface a PC/ISA bus to a LonWorks Network. The 109 is an ISA card which fits into any empty full length ISA slot in a PC. The 109 can host one or two SMX needed for the physical connecting to the LON Works Network. The SMX transceiver can be of different types, e.g. TP - transceiver etc. For ABB Substation Automation Systems the 107 Fibre-Optic SMX transceiver is most commonly used. Fibre-optic SMX transceiver 107 The 107 is a fibre-optic SMX transceiver used together with the 109, PCLTA card, as fibre-optic LonWorks interface for a PC, e.g. a MicroSCADA system. The 107 is mounted on the PCLTA card and provides the card with one or two (two 107 required) fibre-optic channels to the LonWorks Network. The fibre-optic connection is made of plastic or glass fibre cables. SRIO 1000M LON interface A LON interface is included in SRIO 1000M provided with program version 8.31 or later. The SRIO 1000M with LON interface is a remote control gateway used to connect LON to a higher-level system that has an ANSI X3.28 or a SACO 100M protocol. Connection module SPA-ZC 100 and SPA-ZC 102 The connection modules SPA-ZC 100 and SPA-ZC 102 are used to connect SPACOM products, or other devices provided with the SPA bus interface, to the LON bus. The module polls the SPA-bus device for data and if data have changed the module spontaneously sends new information on the LON bus. Transparent SPA-bus messages received by the module from the LON network are forwarded as standard SPA-bus messages to the SPA-bus device. The module connects to the SPA-bus device by means of a TTL (SPA), RS 485 or RS 232 interface and to the LON network is by means of glass or plastic fibre-optic cables. The SPA-ZC 100 Gateway is powered from the host device to which it is connected, while the SPA-ZC 102 is powered from an external power supply. Bus connection module SPA-ZC 101 and SPA-ZC 103 The SPA-ZC 101/SPA-ZC 103 modules or the IEC 870-5-103/SPA gateways are used to connect SPACOM products, or other devices using the SPA-bus interface, to the VDEW interface 6 bus. The gateway polls the SPA-bus device for data and if data have changed, it sends the messages spontaneously to the VDEW6 interface. Transparent SPA-bus messages are received by the IEC 870-5-103/SPA gateway from the VDEW6 network and are forwarded as standard SPA-bus messages to the SPA-bus device. The IEC 870-5-103/SPA Gateway connects to the SPA-bus devices by means of a TTL (SPA), RS 485 or RS 232 interface and to the VDEW6 bus is by means of glass or plastic fibre-optic cables. The SPA-ZC 101 Gateway is powered from the host device to which it is connected, while the SPA-ZC 103 is powered from an external power supply. SPA-ZC_ The SPA-ZC 17, 20, 21,22 are used for connecting SPACOM devices to the SPA bus. The opto-modules are available with (SPA- ZC 17) or without (SPA-ZC 21) external power supply. Versions with more than one fibre-optic pair output are also available, i.e. SPA-ZC 22 with five outputs/inputs and SPA- ZC 20 with 15 outputs/inputs.

Page 4 Technical data Table 1: IEC 870-5-103/SPA gateway 111 Power supply SPGU 240A1 rated voltage U n = 110/120/230/240 V ac U n = 110/125/220 V dc operative range U = 80 265 V ac/dc SPGU 48B2 rated voltage U n = 24/48/60 V dc operative range U = 18 80 V dc Power consumption when all option cards installed <16 W Output relays Terminal numbers X2/1-2, 3-2, 4-2, 5-2 Rated voltage 250 V ac/dc Continuous current carrying capacity 5 A Make and carry for 0.5 s 10 A Make and carry for 3 s 8 A Breaking capacity for dc when the control circuit time constant L/R < 40 ms, at 48/110/220 V dc 1 A/0.25 A/0.15 A Enclosure Contact material AgCdO 2 Degree of protection by enclosure of the device IP 20 case according to IEC 529 Ordering Order numbers for 103 103 BB Plastic Plastic 1MRS 090701-BB 103 BM Plastic Glass 1MRS 090701-BM 103 MB Glass Plastic 1MRS 090701-MB 103 MM Glass Glass 1MRS 090701-MM Order numbers for 107 Type designation Item Order No. 107-MM Fibre-optic SMX transceiver, glass 1MRS 090702-MM 107-BB Fibre-optic SMX transceiver, plastic 1MRS 090702-BB Snap-in type connectors 107-SS Fibre-optic SMX transceiver, plastic SMA type connectors 1MRS 090702-SS Order numbers for 109 Type designation Item Order No. 109 PCLTA card 1MRS 090703

Page 5 Order numbers for 111 The basic version of the 111 module includes the case, the I/O card, the power supply card(s) and the wall mounting bracket. Explanation of the order number: 1MRS 090700-[A/C][A/C/0], where A = auxiliary power supply voltage 80 265 V ac/dc, f = 50/60 Hz C = auxiliary power supply voltage 18 80 V dc 0 = the module includes only one power supply card Example orders of a basic version of 111 Example 1: 1MRS 090700-AC, 111 with auxiliary supply 1: 80 265 V ac/dc, supply 2: 18 80 V dc Example 2: 1MRS 090700-C0, 111 with only one auxiliary supply: 18 80 V dc Item Order No. Mounting accessories Pair of panel mounting brackets 1MRS 050200 Pair of rack mounting brackets 1MRS 050201 Router option card ST type glass fibre-optic SROUT MM 1MRS 050027 SROUT BB 1MRS 050028 SROUT SS 1MRS 050029 SLTA option card ST type glass fibre-optic SSLTA MM 1MRS 050030 SSLTA BB 1MRS 050031 SSLTA SS 1MRS 050032 Double connection option card RS-485 option card Fibre-optic option card Blank plate ST type glass fibre-optic SREDU MM 1MRS 050033 SREDU BB 1MRS 050034 SREDU SS 1MRS 050035 ST type glass fibre-optic SRS485 MM 1MRS 050036 SRS485 BB 1MRS 050037 SRS485 SS 1MRS 050038 ST type glass fibre-optic SFIBER MM 1MRS 050039 SFIBER BB 1MRS 050040 SFIBER SS 1MRS 050041 Blank plates are normally included in the module 1MRS 060023 delivery. Additional blank plates can be ordered separately Order numbers for SPA-ZC 100 and SPA-ZC 102 SPA-ZC 100 BB Plastic Plastic 1MRS 090704-AA SPA-ZC 100 MM Plastic Glass 1MRS 090704-DA SPA-ZC 102 BB Plastic Plastic 1MRS 090705-AA SPA-ZC 102 MM Plastic Glass 1MRS 090705-DA

Page 6 Order numbers for SPA-ZC 100 for voltage regulator SPAU 341 C SPA-ZC 100 BB for Plastic Plastic 1MRS 090704-AB SPAU 341 C, no. 1 SPA-ZC 100 BB for Plastic Plastic 1MRS 090704-AC SPAU 341 C, no. 2 SPA-ZC 100 BB for Plastic Plastic 1MRS 090704-AD SPAU 341 C, no. 3 SPA-ZC 100 MM for Glass Glass 1MRS 090704-DB SPAU 341 C, no. 1 SPA-ZC 100 MM for Glass Glass 1MRS 090704-DC SPAU 341 C, no. 2 SPA-ZC 100 MM for SPAU 341 C, no. 3 Glass Glass 1MRS 090704-DD Order numbers for SPA-ZC 101 and SPA-ZC 103 SPA-ZC 101 BB Plastic Plastic SPA-ZC 101 MM Plastic Glass SPA-ZC 103 BB Plastic Plastic SPA-ZC 103 MM Plastic Glass References Additional information Brochure Substation Communication LONWORKS for Substation Automation 1MRS 750029-MDS EN 1MRS 750714-MEG Echelon, LON and LonTalk are registered trademarks of Echelon Corporation. LONWORKS is a trademark of Echelon Corporation. All other product names are trademarks, registered trademarks, or service marks of their respective owners. ABB Substation Automation Oy P.O. Box 699 FIN-65101 Vaasa Finland Telephone: +358 10 224 000 Fax: +358 10 224 1094