CABLETROLL 3 CABLETROLL CABLETROLL CABLETROLL CABLETROLL LED-2 5 CABLETROLL CABLETROLL REMOTE INDICATION 7

Similar documents
GENERAL INFORMATION. The time it takes to find the fault The time it takes to repair the fault.

IMPROVE CUSTOMER SATISFACTION 3 FUNCTIONAL DESCRIPTION 5 DETECTION PRINCIPLE 6 WHERE SHOULD INDICATORS BE INSTALLED AND WHAT MODEL SHOULD BE USED 7

Product Catalog. Cable Fault Indicators

CONTENTS... 2 COMTROLL SAS. SURVEILLANCE AND AUTOMATION SYSTEM...

LineTroll User Manual

EARTH-FAULT AND SHORT-CIRCUIT INDICATOR TYPE EKL8001 / EKL8002 surface mounted

INTEGRATION OF RECLOSERS INTO SCADA SYSTEMS

Products Portfolio. Pole mounted Vacuum Recloser

Overcurrent and Arc Protection by Reyrolle Alexander Erokhin. 21, 2017 I Berlin

Grid Automation packaged solutions Optimal automation of medium voltage grids

ECP NORTROLL CABLETROLL 2350 FPI INSTALLATION AND COMMISSIONING PROCEDURE

MiCOM P124 T&D. Self and Dual Powered Overcurrent Relays

OHL Fault Indicators Grid Monitoring Software

SIEMENS 8DJH 11/22 kv Ring Main Units

Substation monitoring and control

POWER GRID AUTOMATION. Pág.. n. RMU Automation

DGSZV-EP DIGITAL GALVANIC LONGITUDINAL DIFFERENTIAL PROTECTION. Application field

DC Substations / Supply Program

Sensitive and Selective Ground-Fault Protection in Ungrounded MV Networks Using the DPU-2000R with the Directional-Sensitive-Earth Fault Feature

SIGMA D++ / SIGMA D+ / SIGMA D Directional Fault Indicator

ComTroll 120 GLM GSM modem for sending SMS alarms from LineTroll fault Indicators

High-Reliability Fault-Clearing System solution. Application Guide. Outdoor Distribution (15.5 kv through 38 kv) S&C ELECTRIC COMPANY

Amsterdam 27 September 2017 David MacDonald

DTRV-EP. COMPLEX DIGITAL PROTECTION FOR 120 kv / MEDIUM VOLTAGE TRANSFORMERS. Application field

Collector System Design Considerations for Wind Farms. Sean Carr Ernst Camm S&C Electric Co.

1S20. Arc Fault Monitor Relay. Features. Introduction. ARC Fault Protection

MV Network Managment Fault tracking, monitoring and control. Easergy Range Merlin Gerin

LineTroll R110C GSM communication unit for LineTroll 110EµR phase-mounted fault indicator

Synchronous switching of distribution sub networks

Products for increased power system availability

ABB Data Center Forum 2017

ENhanced TEChnology. Solid insulated vacuum recloser for power distrbution system thru 15kV, 27kV, 38kV V 3.1

MiCOM P124. Self and Dual Powered Overcurrent Relays. Protection Relays

MiCOM P111. Three phase and earth fault overcurrent relays

Karl Iliev, San Diego Gas & Electric Company

VAMP 221. Table of Contents

Installation & Operation and Maintenance

ENhanced TEChnology. Solid insulated vacuum recloser for power distribution system thru 15kV, 27kV, 38kV. Ver.

2 ms arc-flash protection and feeder relay in one platform

Elastimold Molded Vacuum Recloser - MVR

IDS SAS. Station Automation System for Complex Applications

Solid insulated vacuum recloser for power distribution system thru 15kV, 27kV, 38kV Version 3.3

Source-Transfer Application Guide

Function permission: yes/no. Operating range: 0.10 to 30 xin (step 0.01) Operating time: 0.02 to 300 s (step 0.01 s) Activation level 100%

protection & control specialists

DEEP SEA ELECTRONICS PLC

Power System Protection Laboratory Electric Power and Energy Engineering

Small Generator Interconnection Facilities Study Report. Completed for. ( Interconnection Customer ) Proposed Interconnection Pavant substation

Catching Falling Conductors in Midair Detecting and Tripping Broken Distribution Circuit Conductors at Protection Speeds

NU-LEC. Loop Automation. Reclosers & Sectionalizers

THOR Battery Backed DC Power Supply Reference Manual

Advanced Monitoring Solutions for Critical Electric Power Transmission & Distribution Assets

TECHNICAL DESCRIPTION

Davicom Cortex Series*

ECP SECONDARY SUBSTATION COMMISSIONING PROCEDURE

Rapier GX Gas Enclosed Load Break Switch and Sectionaliser up to 38kV with automation or remote control options ENGINEERING BRILLIANT SOLUTIONS

Product Sheet ECO. Types ECG, AMF Technical data. product sheet eco ecg-amf - technical data gb v1.0.docx

Common Departures Interconnecting Facilities Requirements

APIC FortisAlberta s SCADA FAULT INDICATOR Project

TENGIZ PROJECT - FIELD SUBSTATION REPLACEMENT

Microgrids: Building Blocks of the Smart Grid Adaptive Protection Schemes for Microgrids

SIA-C. Overcurrent and Earth Fault Protection Relay for Secondary Distribution. Dual & Self Powered. Main characteristics

LE ELECTRONICS Pvt. Ltd.

FAULT INDICATOR Type EFI/P

EOS SCHNEIDER RINGMASTER 'C' RANGE SWITCHGEAR

Traction Power Systems / Program

PRC Coordination of Protection Systems for Performance During Faults

Efficient Fault Management using Remote Fault Indicators

IntelliTeam II Automatic Restoration System

Advanced Fuse-Saving Techniques. T. ROUSAN Ameren Illinois USA. J. JERMAKOWICZ S&C Electric Company USA

Protection relay for secondary distribution

Type SDR reclosers plus controllers and type B-2 recloser bypass switch assembly usa.siemens.com/mediumvoltage

InteliPro. Protection Relay for Parallel Applications. Technical Specification

Benefits, offering and references

TRACKER 240 SERIES. Load Cell and Weighing Indicators. A Precision Measurement Instrument with Outstanding Features

PD-Series. Emergency Standby. General Description. Available Modes of Operation. Standard Features. User Interface. Communication and Controls

LineScope. Smart Power Monitor. Bulletin DB50C18. US Patent Nos , , and B2

EATON 5S 850/1200/1600

Alexandre Oudalov, ABB Corporate Research, Santiago 2013 Symposium on Microgrids. New Technologies for Microgrid Protection

Lecture 6 Substation Automation Systems

SMS TEXT DIALLER INSTALLATION AND OPERATION MANUAL

Lightweight and flexible recloser control for single-phase applications

SDR recloser. A PH Fault B PH Fault C PH Fault. Ground Fault. SGF Lockout Aux Power OK. Recloser OK

MiCOM P122C Time-Overcurrent Protection

BREAKER FAILURE PROTECTION

OHL Fault Indicators Range

x x 60 mm, 700 gm. Wall mounted enclosure, 1 Kg. Weatherproof, high impact GF ABS. Remote control and monitoring with debug features

MV NETWORK AUTOMATION IN THE TOWN OF MILLION - ZAGREB (CROATIA)

MV NETWORK AUTOMATION IN THE TOWN OF MILLION - ZAGREB (CROATIA)

Recloser Controller for feeder protection and automation siemens.com/distribution-automation

SM100. On-Line Switchgear Condition Monitoring

Netcon 100. Smart Platform for Distribution Automation. Control and monitoring solution for intelligent electricity distribution networks

Sensitive Earth-fault Relay SPAJ 111 C. Product Guide

VIP 40/45 VIP 400/410

Tap Manager TM100. Operating Instructions

iswitch imotor Compact QR

SIPROTEC 7SC80 Feeder Protection and Automation Answers for infrastructure and cities.

Feeder/ Motor Protection Relay VAMP 40

Arc protection relay. Features Three-phase overcurrent function. Application

How smart can the grid really be?

Transcription:

CABLETROLL 3 CABLETROLL 2310 4 CABLETROLL 2320 4 CABLETROLL 2330 5 CABLETROLL 2350 5 LED-2 5 CABLETROLL 2410 6 CABLETROLL 2440 6 REMOTE INDICATION 7

The CableTroll indicators are fault current detectors for the underground medium voltage distribution network (6-36kV). They are used to detect short circuit and earth faults, and can be installed on most types of cable terminations. Some units will give separate indication for short circuit and earth faults, locally by flashing diodes and remotely through separate relay contacts or additional ComTroll communication modules. SLEEPING INDICATORS 22kV/220V 22kV/220V FLASHING INDICATORS 132kV/22kV 22kV/220V All indicators between the feeding transformer and the fault location activate. CABLETROLL fault indicators provide fast fault localisation enabling reduction in outage times. This represents enhanced service to the customers thereby improving the utilities image and significant reduction in the cost related to faults and outages. Another important aspect of using fault indicators is that unnecessary operations of circuitbreakers and sectionalizers to locate faults are avoided. This way the indicators help to reduce wear and tear as reclosing cycles causes stress to the switchgear. Fault currents in cable network The short circuit current magnitude is mainly given by voltage level, type of transformer, primary feeding network and the distance from the feeding transformer to the fault location. A cable short circuit will normally cause a fault current in the ka-range. When short circuit appears near the end of a long line, the fault current is most likely to be of a significantly lesser value. In networks with directly earthed neutral an earth fault is equivalent to a phase-to-earth short circuit. The current magnitude will in this case be almost equal to the fault current of a phase-tophase short circuit. For networks that do not have a directly earthed neutral, the magnitude of the earth fault current is determined by the size of the galvanic interconnected network, the voltage level, type of cable and the neutral equipment. The magnitude of a fault current during a dual earth fault will be almost equal to a short circuit in networks that do not have a directly earthed neutral. As the sensor principle is of the threshold type, correct use of the indicator is subject to calculations of earth fault currents and capacitive discharge currents through the sensor element (seen from the feeder). The capacitive discharge current from behind the earth fault element must not exceed the trip level setting of the indicator. The capacitive discharge current will vary between the different types of cable, and the cable supplier should be consulted about the data for your specific type in order to make the correct calculations.

CableTroll 2310 is an indicator for detection of earth faults (PtG) on multi-core and single core cable terminations. The unit uses NorTroll type current sensor (CT) Programmable: Trip level PTG: Dipswitches 5-240A fixed & adjustable levels Manual, timer, automatic and remotely PtG and Battery monitoring PTG (NO & NC) Lithium Battery or 9-48Vdc with battery backup Mains option available CableTroll 2320 is an indicator for detection of Earth faults (PtG) and short circuit (PtP) faults on multi-core and single core cable terminations. The unit uses NorTroll type current sensors. Trip level PtG: 5-240A, fixed & adjustable levels Trip level PtP: 300-1000A Manual, timer, automatic and remotely Separate PtP and PtG and Battery monitoring Separate PtP & PtG Lithium Battery or 9-48Vdc with battery backup Mains option available

CableTroll 2330 is an indicator for detection of earth faults (PtG) and short circuit (PtP) faults on multi and single core cable terminations. The unit uses NorTroll type current sensors Trip level PtG: 5-240A, fixed & adjustable levels Trip level PtP: 250-1000A Manual, timer, automatic and remotely Separate PtG and PtP and Battery monitoring Separate PtG & PtP Lithium Battery or 9-48Vdc with battery backup Mains option available CableTroll 2350 is an indicator for detection of PtG and PtP faults on multi and single core cables. The unit uses standard type current transformers. (40:1, 60:1 or 3x500:1) Trip level PtG: 50A Trip level PtP: 250-1000A Manual, automatic by timer and remotely Separate PtG & PtP Common PtG & PtP Power Supply Lithium Battery LED-2 is a flashing unit which can be mounted outside a kiosk etc. It provides a strong flash in a rugged design and does not require additional power source

CableTroll 2410 is an eart fault indicator for detection of PtG faults on single and multi-core cables. The unit uses NorTroll type current sensors. The housing is suitable for panel mounting in RMU s. Trip level PTG: 6-340A fixed & variable levels Manual, timer and remotely PtG and Battery monitoring PtG Lithium Battery CableTroll 2440 is an indicator for detection of PtG and PtP faults on single and multi-core cable terminations. The unit uses NorTroll type current sensors. The housing is suitable for panel mounting in RMU s. Trip level PTG: 20-160A Trip level PTP: 250-1000A Manual, timer, remotely and automatic by return of Voltage or Current PtG/ PtP and VPI/CPI (Volt/Current Present Indication) Common PtG- & PtP-fault and Low battery Lithium battery

All of our CableTroll fault indicators have a relay output for interfacing with equipment that can forward the alarms to a control center, SCADA system or cell-phone. Nortroll offers a wide range of communication modules and RTUs with various communication options such as radio, GSM, fibre, Ethernet etc. NORTROLL AS Havneveien 17 7601 Levanger, Norway Tel: +4774 085500 Fax: +4774 085501 nortroll@nortroll.no