Model Number Structure

Similar documents
G3NE. Model Number Structure. Solid State Relays. Model Number Legend. Compact, Low-cost, SSR Switching 5 to 20 A

G3NE. Ordering Information. Solid State Relay. Compact, Low-cost, SSR Switching 5to20A J ACCESSORIES (ORDER SEPARATELY) Solid State Relay G3NE

Model Number Structure

Model Number Structure

(Applicable output load) to 264 (see note 2) (see note 1) (2Aat75to264VAC) G3R-202SLN-US PCB Yes 2 A at 100 to 120 VDC. (2 A at 75 to 132 VDC)

Model Number Structure

G3PC. Model Number Structure. Solid State Relays with Failure Detection Function. Model Number Legend

Model Number Structure

G3F/G3FD. Model Number Structure. Solid State Relays Model Number Legend

Solid State Relays with Failure Detection Function

G3B/G3BD. Model Number Structure. Ordering Information. Solid State Relays Model Number Legend. List of Models

G3H/G3HD. Model Number Structure. Solid State Relays Model Number Legend

Bulletin 700-SH Solid-State Relays. Overview/Product Selection. Bulletin 700-SH. Product Selection

Model Number Structure

Model Number Structure

(75 to 264 VAC) 12 VDC 24 VDC No 5 VDC G3MC-202PL 12 VDC 24 VDC

D2D. Door Interlock Switch. Ordering Information. Power Switch with Minimum Contact Gap of 3 mm. Model Number Legend.

Solid-state Timer. Ordering Information. Specifications. Miniature Timer Compatible with the MY Relay. Accessories. Time Ranges

G3FM. Model Number Structure. Ordering Information. Solid State Relays. Model Number Legend. List of Models

G3S4-A 5 VDC 12 VDC 24 VDC 0.6 A at 75 to 264 VAC (See note 1.) G3S4-A1 5 VDC 12 VDC 24 VDC Yes G3SD-Z01P-PD 1 A at 3 to 26 VDC (See note 2.

NEW Series SSH Output to 75A, 510 Vac with Diagnostics High Industrial Performance (HIPpak) Solid-State Relays

Solid-state Timer. Ordering Information. Miniature Timer with Multiple Time Ranges and Multiple Operating Modes H3YN- - Accessories (Order Separately)

Terminal Relay types. Common note. Terminal Relay/Terminal SSR Mounted relays. Compact Terminal Relays/Terminal SSRs with four outputs

Note: Each relay to be mounted must incorporate a coil that has proper specifications within the maximum rated voltage range.

Safety Relay Unit (I/O Unit Type)

S8VE (60/90/120/180/240-W Models)

Solid-state Timer H3YN

SRT2-ROC08, SRT2-ROC16

Main contacts Auxiliary contact Number of input channels Rated voltage Model Category 24 VAC/VDC 3PST-NO SPST-NC 1 channel or 2 channels possible

Voltage Current Front-mounting bracket

Ordering Information. I/O Relay G7T. Model Number Legend Slim-styled I/O Relay Saves Space in Panel

Conforms to VDE0435/2021 C/250, VDE0110, VDE0106/P100 Conforms to EN , pren

D2D. Door Interlock Switch. Ordering Information. Power Switch with Minimum Contact Gap of 3 mm. Model Number Legend.

Model Number Structure

Ordering Information. I/O Relay G7T. Model Number Legend Slim-styled I/O Relay Saves Space in Panel

Combine Relays and P7TF Block Bases to match your application requirements. Use the table below to configure Relay Blocks.

Model Number Structure

4 mm. 8 mm. Proximity Sensor. Sensing head Sensing distance Output configuration Part Number M18 Shielded 4 mm DC 3-wire PNP-NO E2EZ-X4B1 M30

Compact high capacity, (25A max) Slim heat sink combined type added

Thread length (overall length) material

Load current 10 to 25 A Small Tab Terminal SSR

Switching Power Supply S82J. Ordering Information. Open-Frame, Covered-Frame, or Enclosed-Frame Type with Capacity Up to 600 W

Switching Power Supply

16 g SS-01GL-FD SS-01GL-F SS-01GL-FT 50 g SS-01GLD SS-01GLD1 SS-01GLD2 SS-01GL SS-01GLT Simulated roller lever

Load current 10 to 25A Small Tab Terminal SSR

Functional configuration Rated input voltage Power ratings Output voltage Output current Part number Non-PFC

Terminals Solder terminals Quick-connect. PCB terminals terminals (#110) 3 A Pin plunger SS-3GP SS-3GPT SS-3GPD SS-3GPB

Time-limit contact Time ranges Supply voltage Mounting s to 3 h 24, 100 to 120, 200 to 230 VAC (50/60 Hz); 12, 24, 48, 125, 100 to 110 VDC

Switching Power Supply S8E1. Ordering Information. Compact and Economical Switching Power Supply

Compact high capacity, (25A max) Slim heat sink combined type added

Special-purpose Basic Switch

Model Number Structure

DPST-NO None 2 channels Auto-reset Inverse (+/-) 24 VAC/VDC 4 G9SB-2002-A 1 channel or 2

G9SA. Ordering Information. Safety Relay Unit. The G9SA Series Offers a Complete Line of Compact Units. H Several types of 45-mm wide Units are

G9H. Ordering Information. Hybrid Power Relay. List of Model. Accessories (Order Separately) Connecting Socket Mounting Plate

Inductive Proximity Sensor

Ordering Information. Door Interlock Switch D2D. Power Switch with Minimum Contact Gap up to 3 mm. D2D - 0. Model Number Legend

Appearance Size (mm) Power supply voltage Model (W H D) 100 to 240 VAC K3SC to 240 VAC

With operation indicators **LY2N-CR **LY2ZN-CR

H3CR-H. Solid-state Power OFF-delay Timer. Ordering Information. DIN 48 x 48-mm Solid-state Power OFF-delay Timer

Model Number Structure

Model Number Structure. Ordering Information. Switch Mode Power Supply S82K (3/7.5/15/30/50/90/100-W Models) Model Number Legend.

Setting method Indication Control Output Model method mode Thermocouple (with sensor burnout detection circuit)

Number of input channels

Switching Power Supply

MOS FET Relay. Ordering Information. Application Examples G3VM- XN(F)/4N(F)

MODEL NUMBERS OUTPUT SPECIFICATIONS 1 Zero Voltage and Random Turn-On Switching Panel Mount 600V Transient Capability Internal Snubber 110 & 125A Mode

Installation Sensing distance Connection Output configuration Operation mode NO Operation mode NC

Inductive Proximity Sensor

Solid-state Timer. Ordering Information. Ultra-slim Timer for G2R Relay Socket. H3RN-jj. Accessories (Order Separately) Connecting Socket

Model Number Structure. Power Controllers G3PX. Single-phase Models. Model Number Legend

PRODUCT SPECIFICATION. PC Board Relays. Series.

Miniature Basic Switch

Relays & Sockets. RSC Series. RSC Series Solid State Relays. Part Number Selection Specifications

Ordering Information. Snap Action Switch V. Model Number Legend V General Purpose Snap Action Switch. Snap Action Switch V 121

Thread length. 27 (40) mm. 27 (44) mm. 27 (40) mm. 34 (50) mm. 34 (49) mm. 39 (60) mm. 39 (54) mm. 44 (65) mm. 44 (59) mm

S82S (3/7.5-W Models)

Self-Powered Counters H7EC

E2A. Ordering Information. Cylindrical Proximity Sensor. Safe Mounting with Greater Sensing Distance. E2A Cylindrical Proximity Sensor 1

SS Series Compatible Mounting with a Simple Construction and Easy-to-Use Design Concept

Model Number Structure

Model Number Structure

Conductive Level Controller

S82J (10/25/50/100/150/300/600-W Models) CSM_S82J_DS_E_3_1

D2VW. Sealed Miniature Basic Switch. Ordering Information Model Number Legend D2VW- -

Switch Mode Power Supply

Ex. H3Y-2-C 110 VAC 30 s Rated time Supply voltage 2. Sockets and Hold-down Clips are not included with the H3Y. They must be ordered separately.

Long-time range model (0.1 min to 10 h) 24 VAC; SPDT H3RN-1 H3RN-11 12, 24 VDC DPST-NO H3RN-2 H3RN-21

RUC industrial relays of small dimensions

Model Number Structure

Cylindrical Proximity Sensor

Contact form. Operating Force. SPDT 25g Unsealed Solder / 187 Quick Connect. SPDT 50g Unsealed Solder / 187 Quick Connect

D2SW-3L1HS D2SW-01L1HS

Time-limit operation/ self-resetting DPDT --- H3M H3M with Y92F-40 adapter SPDT SPDT H3M-H H3M-H with Y92F-40 adapter

A16. Separate Construction with Cylindrical 16-dia. Body. Pushbutton Switch (Detachable) (Lighted/Non-Lighted) (Cylindrical 16-dia.

Kuhnke Technical Data. Contact Details

Solid-state Timer. Mounting system contact t contact. t Surface mounting/ track mounting

Light ON 5m. * Light ON. 2.5m (3m) Light ON. (5m)

Ordering Information. Three-phase Input Switch Mode Power Supply S8VT S8VT. Model Number Legend

Model Number Structure

Transcription:

Solid State Relays CSM DS_E_3_1 Compact, Low-cost, SSR Switching 5 to 20 A Wide load voltage range: 75 to 264 VAC. Both 100-V and 200-V loads can be handled with the same model. Dedicated, compact aluminum PCB and power elements used. Built-in varistor effectively absorbs external surges. Quick-connect #110 input terminals and #250 output connections. (#187 input terminals and #250 output connections are available.) -US models certified by UL, CSA, and IEC/EN (TÜV). Refer to Safety Precautions for All Solid State Relays. Model Number Structure Model Number Legend -@@@@-@-@ 1 2 3 4 5 6 7 1. Basic Model Name : Solid State Relay 2. Rated Load Power Supply Voltage 2: 200 VAC 3. Rated Load Current 05: 5 A 10: 10 A 20: 20 A 4. Terminal Type T: Quick-connect terminals 5. Zero Cross Function Blank: Equipped with zero cross function L: Not equipped with zero cross function 6. Special Specifications Blank: Standard models 2: #187 input terminals 7. Certification US: Certified by UL, CSA, and TÜV Ordering Information List of Models Isolation Zero cross Indicator Rated output load Rated input voltage Model function (See note 1.) Phototriac Yes No 5 A at 100 to 240 VAC 5, 12, 24 VDC -205T-US -205T-2-US 10 A at 100 to 240 VAC -210T-US -210T-2-US 20 A at 100 to 240 VAC -220T-US -220T-2-US No 5 A at 100 to 240 VAC -205TL-US -205TL-2-US 10 A at 100 to 240 VAC -210TL-US -210TL-2-US 20 A at 100 to 240 VAC -220TL-US -220TL-2-US Note: 1. The rated input voltage depends on the ambient temperature. For details, refer to Load Current vs. Ambient Temperature in Engineering Data on page 3. 2. When ordering, specify the input voltage. 3. Refer to List of Certified Models for a list of products that comply with safety standards. When ordering a UL, CSA, and EN(TÜV) certified model, add -US to the model number. 1

Accessories (Order Separately) Heat Sinks The following heat sinks are thin and can be DIN-track mounted. See Dimensions for details. Model Y92B-N50 Y92B-N100 Applicable SSR -205T(L)(-2)-US/-210T(L)(-2)-US -220T(L)(-2)-US Specifications Ratings (at an Ambient Temperature of 25 C) Rated voltage Operating voltage Voltage level impedance Must operate Must release With zero cross function Without zero cross function 5 VDC 4 to 6 VDC 4 VDC max. 1 VDC min. 250 Ω±20% 300 Ω±20% 12 VDC 9.6 to 14.4 VDC 9.6 VDC max. 600 Ω±20% 800 Ω±20% 24 VDC 19.2 to 28.8 VDC 19.2 VDC max. 1.6 kω±20% Note: Each model has 5-VDC, 12-VDC, and 24-VDC input versions. Model Applicable load Rated load voltage Load voltage range Load current (See note 1.) Inrush current With heat sink -205T(L)(-2)-US 100 to 240 VAC 75 to 264 VAC 0.1 to 5 A at 40 C 0.1 to 5 A at 40 C 60 A (60 Hz, 1 cycle) -210T(L)(-2)-US 0.1 to 10 A at 40 C 0.1 to 5 A at 40 C 150 A (60 Hz, 1 cycle) -220T(L)(-2)-US 0.1 to 20 A at 40 C 0.1 to 5 A at 40 C 220 A (60 Hz, 1 cycle) Note: 1. The load current varies depending on the ambient temperature. Refer to Load Current vs. Ambient Temperature under Engineering Data for details on page 3. 2. These values apply when using a dedicated heat sink or a radiation plate of specified size. Characteristics Item -2@@T(-2)-US -2@@TL(-2)-US Operate time 1/2 of load power source cycle + 1 ms max. 1 ms max. Release time 1/2 of load power source cycle + 1 ms max. ON voltage drop 1.6 V (RMS) max. Leakage current 2 ma max. (at 100 VAC) 5 ma max. (at 200 VAC) Insulation resistance 100 MΩ min. (at 500 VDC) Dielectric strength 2,000 VAC, 50/60 Hz for 1 min Vibration resistance Destruction: 10 to 55 to 10 Hz, 0.75-mm single amplitude Shock resistance Destruction: 1,000 m/s 2 Ambient temperature Operating: 30 C to 80 C (with no icing or condensation) Storage: 30 C to 100 C (with no icing or condensation) Ambient humidity Operating: 45% to 85% Certified standards EMC Weight UL508 File No.E64562/CSA C22.2 (No.0, No.14) File No. LR35535 TÜV R9051064 (VDE0435) (EN60950) Emission: EN55011 Group 1 Class B Immunity: EN61000-6-2 Approx. 37 g 2

Engineering Data Load Current vs. Ambient Temperature -205T(L)(-2)-US -210T(L)(-2)-US -220T(L)(-2)-US With standard heat sink (Y92B-N50) or aluminum plate measuring 100 mm x 100 mm x t2 mm (W x H x D) With standard heat sink (Y92B-N100) or aluminum plate measuring 300 mm x 300 mm x t3 mm (W x H x D) Ambient temperature ( C) Ambient temperature ( C) Ambient temperature ( C) One Cycle Surge Current: Non-repetitive Note: Keep the inrush current to half the rated value if it occurs repetitively. -205T(L)(-2)-US -210T(L)(-2)-US -220T(L)(-2)-US 3

Dimensions Note: All units are in millimeters unless otherwise indicated. -205T(L)/210T(L)/220T(L)(-2)-US 3.5 dia. hole 47.5 max. Terminal Arrangement/ Internal Connections (Top View) 37.5 max. 30+0.5 14.5 Two #110 (t = 0.5) (Faston tab or equivalent)* 7.1 2.9 6 6.5 Two #250 (t = 0.8) (Faston tab or equivalent) 3 7.95 11.5 max. voltage 3 + 4 1 2 Load Load power supply Heat Sink Y92B-N50 * -2@@T(L)-2-US: Two, #187 (t=0.5) (Faston tab or equivalent) 4.6 dia. hole Two, M3 holes Two, M4 holes Two, 3.2-dia. holes 30±0.2 Two, 3.5-dia. or M3 holes Y92B-N100 35 30.5±0.3 44 max. 30 47 max. 4.6 dia. hole 47.6 77 max. 90±0.3 Two, M3 holes 5.6 Two, M4 holes 5 6 4.5 51 max. Two, 3.2-dia. holes Two, 4.4-dia. or M4 holes 35±0.2 90±0.4 Weight: approx. 200 g 35 30.5±0.3 71 max. 30 75 max. 90±0.4 47.6 77 max. 90±0.3 5.6 5 4.5 28 13 Two, 4.4-dia. or M4 holes 35±0.2 Weight: approx. 400 g Safety Precautions Refer to Safety Precautions for All Solid State Relays. Precautions for Correct Use Please observe the following precautions to prevent failure to operate, malfunction, or undesirable effect on product performance. Do not apply excessive force to the terminals. Be careful when pulling or inserting the terminal clips for the Quick Connector (QC). When attaching a heat sink to the, in order to facilitate heat dissipation, apply heat-conductive grease on the heat sink. For DIN Track mounting, use a separately sold Heat Sink. Refer to information on the G3NA. -210T(L): Y92B-N50-220T(L): Y92B-N100 Tighten the mounting screws of the heat sink with a torque of 0.59 to 0.98 N m. Thermal Resistance Rth (Back of Junction SSR) Model Thermal resistance ( C/W) -205T (L) 2.72-210T (L) 2.12-220T (L) 2.22 EMC Directive Compliance The complies with EMC Directives under the following conditions ("-US" models only). 10 m max. -US Load Film capacitor: 1 µf, 250 VAC Connect a film capacitor to the load power supply. The input cable must be less than 10 m. 4

ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. In the interest of product improvement, specifications are subject to change without notice. 5