ABB i-bus KNX Thermoelectric Valve Drive, 230 V TSA/K 230.2, 2CDG R0011

Similar documents
ABB i-bus KNX HCC/S Heating/cooling circuit controller

ABB i-bus KNX BCI/S Boiler/Chiller Interface

ABB i-bus KNX AC/S Application Controller

ABB i-bus KNX Analogue Actuator, 4-fold, MDRC, 0-10 V, 0-20 ma AA/S 4.1.2, 2CDG110202R0011

PRODUCT MANUAL. ABB i-bus KNX SV/S KNX-Power Supplies

ABB i-bus KNX Weather Unit, 1-fold, MDRC WZ/S , 2CDG110184R0011

ABB i-bus KNX Analogue Input, 4-fold, MDRC AE/S , 2CDG110190R0011

ABB i-bus KNX Switch Actuator, x-fold, 10 A, MDRC SA/S x , 2CDG11015xR0011

ABB i-bus KNX Logic Controller ABA/S 1.2.1, 2CDG110192R0011

ABB i-bus KNX Fan Coil Actuator, PWM, MDRC FCA/S , 2CDG110195R0011

ABB i-bus KNX IP Router, MDRC IPR/S 3.1.1, 2CDG110175R0011

ABB i-bus KNX Switch Actuator, Current Detection, x-fold, 16/20 A, C-Load, MDRC SA/S x , 2CDG1101xxR0011

HERZ Actuator 7708, 7990

Electronic timer CT-SDD.22 Star-delta change-over with 2 n/o contacts

Electronic timer CT-EBD.12 Flasher starting with ON with 1 c/o (SPDT) contact

ABB i-bus KNX KNX/EnOcean Gateway EG/A , 2CDG R0011

Accessories for pluggable interface relays CR-P Sockets

Switching relay CT-IRE with 1 c/o (SPDT) contact

Electronic timer CT-ARE OFF-delayed without auxiliary voltage, 1 c/o (SPDT) contact

Pluggable interface relays CR-P Pcb relays

ABB i-bus KNX DALI Light Controller, 8-fold, MDRC DLR/S M, 2CDG110101R0011

Intrusion Detection Technology SafeKey Switching Module SSM/A, SSM/U Product Manual

Electronic timer CT-SDS.23 Star-delta change-over with 2 n/o contacts

Device technology. Supply Bus voltage V DC. Current consumption via bus. Accuracy in the range 300 1,000 ppm 1,000 2,000 ppm 2,000 5,000 ppm

Voltage monitoring relays CM-ESS.1 For single-phase AC/DC voltages

Power supply CP-D 12/2.1 Primary switch mode power supply

Accessories for pluggable interface relays CR-P, CR-M Pluggable function module

Electronic timer CT-ARS.11 OFF-delayed without auxiliary voltage with 1 c/o (SPDT) contact

Electronic timer CT-ERS.12 ON-delayed with 1 c/o (SPDT) contact

Pluggable interface relays CR-M Miniature relays

Accessories for pluggable interface relays CR-U Pluggable function modules

Electronic timer CT-ARS.21 OFF-delayed without auxiliary voltage with 2 c/o (SPDT) contacts

Boxed interface relays and optocouplers R600 Boxed slim relays, optocouplers and accessories

Power supply CP-E 48/1.25 Primary switch mode power supply

Power supply CP-E 24/0.75 Primary switch mode power supply

Pluggable interface relays and optocouplers CR-P Pcb relays, optocouplers and accessories

Messaging module CP-C MM

ABB i-bus KNX Application Unit Time ABZ/S 2.1 Product Manual

ABB i-bus KNX SUG/U 1.1 Split Unit Gateway Product Manual

Actuator ABNM A5 LOG/LIN for AB-QM, 0-10 V Proportional

Electronic timer CT-AHS OFF-delayed with 2 c/o contacts Data sheet

Electronic timer CT-EAS ON-delayed and OFF-delayed with 1 c/o contact Data sheet

Redundancy unit CP-A RU

Power supply CP-E 24/10.0 Primary switch mode power supply

Electronic timer CT-VWD Impulse-ON with 1 c/o contact Data sheet

Redundancy unit CP-D RU Accessory for CP range power supplies (e.g. switch mode power supplies CP-D range)

RTU511. Binary Output 23BO62. Characteristics. Application. Data Sheet Binary Output 23BO62. The binary output is made via relay contacts.

Electronic timer CT-APS.21 OFF-delayed with 2 c/o (SPDT) contacts

Electronic timer CT-AWS Impulse-OFF with 2 c/o contacts Data sheet

Electronic timers CT range

RTU500 series Data Sheet Power Supply CP-E 24/2.5

ABB i-bus EIB / KNX Blower/Fan Coil-Aktuator LFA/S 1.1, LFA/S 2.1. Product Manual. Intelligent Installation Systems ABB

Buffer module CP-B 24/20.0, ultra-capacitor based Accessory for power supplies (e.g. switch mode power supplies CP range)

Electronic timer CT-ERD ON-delayed with 1 c/o contact Data sheet

Switching relay CT-IRS with 1, 2 or 3 c/o contacts Data sheet

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

ABB i-bus KNX Blower/Fan Coil-Actuator LFA/S 1.1, LFA/S 2.1. Product Manual. Intelligent Installation Systems ABB

ABB i-bus KNX Switch Actuator, x-fold, 16 A, MDRC SA/S x , 2TAZ710xx1R2161

Electronic timer CT-ERD.12

TEPI11 P/I signal converter

Electronic timer CT-ERS.12 ON-delayed with 1 c/o contact Data sheet

Electronic timer CT-AHD.22

Electronic timer CT-ARS.21 OFF-delayed without auxiliary voltage with 2 c/o (SPDT) contacts

Digital Indicator DS 48/24 E

Technical Manual Room temperature controller

Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011

Thermistor motor protection relays CM-MSS.12 and CM-MSS.13

SMARTER HOME. Building systems technology KNX Visualisation options

ABB i-bus KNX Switch Actuator, x-fold, 6 A, MDRC SA/S x.6.1.1, 2CDG x R0011

Electronic timer CT-ARS.11

INDI BOY DSP Load limitation electronics

Electrical Actuators

EMO valve drive. 1. Function 1. Table of Contents. 2. Installation

Electronic timer CT-ERS.21

Product and functional description. Application Program. instabus EIB Technical product information. April (6 x AC 230 V / 0,05 A)

Products no longer available

Thermistor motor protection relays CM-MSS.22 and CM-MSS.23

The new Arc Fault Detection Device S-ARC1 Maximum safety easy installation

Electrical actuators

Bus Connection Unit 560BCU04

Accessories for pluggable interface relays CR-M Sockets

ABB ME ASURE ME NT & AN AL YT ICS D AT A SHE ET. WirelessHART components Gateway and accessories

Thermistor motor protection relay CM-MSS.11

Immersion Temperature Sensors

RTU560. CT/VT Interface 560CVT10. Meter Operation. Application. Characteristics. Data Sheet CT/VT Interface 560CVT10. Instantaneous Meter Values

Room Temperature Controllers

ST 200 M data sheet System pro M compact miniature circuit breakers for supplementary protection acc. to UL 1077

Heating Circuit Controller

RTT2 ROOM TEMPERATURE SWITCH. Mounting and operating instructions

ABB i-bus KNX Fan Coil Actuators FCA/S Product Manual

Electromotoric actuators

Binary output and supervision 520CSD01 Data sheet

LineMaster 100 Continuous-line Recorder

Products no longer available

ABB i-bus KNX Fan Coil Actuator FCA/S 1.1M Product Manual

Line Coupler, MDRC LK/S 2.1, GH Q R0001

String monitoring with CMS - Circuit monitoring system Increased productivity and improved maintenance of PV systems

Datasheet RCUXXYY EAE KNX Room Control Unit RCUXXYY DT R1.0. General Description. EAE Technology Page 1/10

AV24-MFT AV24-MFT2 AV24-MFT2-C105. Power consumption In operation For wire sizing N 1700 N Control Control signal Y Operating range

ABB i-bus KNX Fan Coil Actuators FCA/S Product Manual

Transcription:

Technical Data 2CDC508160D0201 ABB i-bus KNX Product Description The Thermoelectric Valve Drive is used to open and close valves in Heating, Ventilating and Air-Conditioning (HVAC) systems. The device can be controlled (2-point output or pulse width modulation) with the Electronic Switch Actuator ES/S, with the Valve Drive Actuator VAA/S or VAA/A or with the Electronic Relay ER/U in combination with the Universal Interface US/U and a Room Thermostat. The snap-on mounting on valves or in heating circuit distributors will be established by Valve Adapters VA/Z.

Technical Data Version Power supply Connection Normally Closed First-Open function Operating Voltage Operating current Max. inrush current Operating power Over voltage protection according to EN 60730-1 Connection cable (pluggable) Length NC Enables heating operation during the carcass construction phase even when the electric wiring of the single room control is not yet complete. 230 V AC ± 10 %, 50/60 Hz 5 ma <550 ma during 100 ms max. 1 W At least 2.5 kv 2 x 0.75 mm², light grey 1 m Operating and display elements Function display Displays whether the valve is opened or closed Valve drive mechanic Actuator travel Actuator force Closing and opening times 4 mm 100 N ± 5% Approx. 3 min. Ambient temperature range Fluid Environment Storage Design Compact device for placing on valve bases Housing Dimensions (H x W x D) Material Colour Mounting Snap-on mounting Installation positions 0 C... + 100 C 0 C... + 60 C 25 C... + 60 C 60 x 44 x 49 mm Plastic Light grey, RAL 7035 Via Valve Adapter VA/Z 360 (vertical and horizontal recommended) Type of protection IP 54 (in all installation positions) According to DIN EN 60529 Protection class II According to DIN EN 61140 Weight 0.1 kg CE-norm According to EN 60730 Accessory Type VA/Z 10.1 VA/Z 50.1 VA/Z 78.1 VA/Z 80.1 Model Valve Adapter (M 30 x 1.5) for Dumser, Chronatherm, Vescal, KaMo Valve Adapter (M 30 x 1.5) for Honeywell, Reich, Cazzaniga, Landis & Gyr., MNG Valve Adapter (Flange) for Danfoss RA Valve Adapter (M 30 x 1.5) for Heimeier, Herb, Onda, Schlösser (from 93), Oventrop 2 2CDC508160D0201 TSA/K 230.2

Circuit diagram Dimension drawing 2CDC 072 007 F0015 2CDC 072 004 F0015 2CDC 072 006 F0015 Dimension drawing installation height TSA/K 230.2 2CDC508160D0201 3

Characteristic curves 2CDC 072 329 F0205 Mounting and Installation Generally all installation positions are possible for practical use. Preferred installation positions of the valve drive are vertical and horizontal. An upside-down position may reduce product life through special circumstances (e.g. contaminated water). We recommend the following wires for installation a 230 V system: Light plastic-sheated cable: NYM Flat webbed building wire: NYIF 1.5 mm² 1.5 mm² The valve adaptation occurs via the Valve Adapter VA/Z. Those are available for the most common valve bases and heating circuit distributors. See also Accessory. In its delivery state the valve drive is normally open due to the First-Open function. This enables heating operation during the carcass construction phase even when the electric wiring of the single room control is not yet complete. When commissioning the system at a later date, the First-Open function is automatically unlocked by applying the operating voltage (> 6 min.) and the valve drive is fully operable. 4 2CDC508160D0201 TSA/K 230.2

Important notes Installation and commissioning of the device may only be carried out by trained electricians. The relevant standards, directives, regulations and instructions must be observed when planning and implementing the electrical installation. Protect the device against moisture, dirt and damage during transport, storage and operation! Do not operate the device outside the specified technical data (e.g. Temperature range)! Cleaning Should the device become soiled, it may be cleaned with a dry cloth. If this does not suffice, a cloth lightly moistened with soap solution may be used. On no account should caustic agents or solvents be used. Maintenance The device is maintenance free. Should damage have occurred, e.g. due to transport or storage, no repairs should be carried out. The warranty expires if the device is opened! TSA/K 230.2 2CDC508160D0201 5

Contact ABB STOTZ-KONTAKT GmbH Eppelheimer Straße 82 69123 Heidelberg, Germany Telefon: +49 (0)6221 701 607 Telefax: +49 (0)6221 701 724 E-Mail: knx.marketing@de.abb.com Further Information and Local Contacts: www.abb.com/knx Note: We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. ABB AG does not accept any responsibility whatsoever for potential errors or possible lack of information in this document. We reserve all rights in this document and in the subject matter and illustrations contained therein. Any reproduction, disclosure to third parties or utilization of this contents - in whole or in parts - is forbidden without prior written consent of ABB AG. Order Number 2CDC508160D0201 (05/2015) Copyright 2015 ABB All rights reserved