MODBUS. M920 protocol description. User s manual

Similar documents
Modbus Remote Communication Protocol for REM 54_. Technical Description

ALTOSONIC V12 Modbus manual. Protocol description & set-up

INSTRUCTION MANUAL ESI-Manager communication How to use RS485 USB Ethernet connections

List of Contents 1. INTRODUCTION DEFINITIONS AND ABBREVIATIONS REFERENCES TECHNICAL DATA GENERAL MODBUS RTU...

Modbus Protocol For FTS/FTM 3x&8x

Golander Peristaltic Pump MODBUS Communication Instruction

INSTRUCTION MANUAL RVT communication How to use RS485 USB Ethernet RVT connections

$GDSWLYH0LFUR6\VWHPV

TECH TIP. Tritex Modbus Protocol Specification

INTELLIS. Modbus Direct Network Monitor

Modbus Protocol For TGP03 / THP03

ModBus Communication protocol. The ModBus protocol is an industrial communications and distributed control system

[ 公司地址 ] Modbus Protocol. For THS/THM 30X&80X_Temp.&Humididy & THS8X/THM8X_Dew Point Series V7.0

SC2004MBS 20x4 Characters MODBUS RTU Slave LCD

Modbus Protocol For PMX / PXM3X

SPM90 MODBUS PROTOCOL AND REGISTER LIST V1.0

Conto D2 COMMUNICATION PROTOCOL CONTENTS 1.0 INTRODUCTION

B Interface description 12.01/

1.Eastron SDM230Modbus Smart Meter Modbus Protocol Implementation V1.2

FnIO S-Series. FnIO MODBUS Adapter Specification Rev 1.00 NA-9473 (MODBUS/RS485) Page 1 of 30. NA-9473 (MODBUS/RS485) Adapter

MODBUS APPLICATION PROTOCOL SPECIFICATION V1.1b3 CONTENTS

JUMO ctron 04/08/16. Compact controller with timer and ramp function. B Interface Description Modbus /

General Specifications

MODBUS APPLICATION PROTOCOL SPECIFICATION V1.1b3 CONTENTS

JUMO Quantrol LC100/LC200/LC300

MODBUS Protocol Specification. MODBUS Protocol Specification V2.0

Forlong MODBUS Protocol Specification V1.0

Input Channels: 4 differential or four single-ended. Address / Baud rate / range configurable by the user

MODBUS Network Communication

CE4DMID01 COMMUNICATION PROTOCOL CONTENTS 1.0 INTRODUCTION

In-Situ Modbus Communication Protocol Version 5.8

User Manual version 1.04 TLM8 COMMUNICATION PROTOCOLS

JDICON 1000 JDICON B Interface Description 3.99/ Universal Process Controller. Universal Profile Controller

IFC 100 Supplementary instructions

Sample F4T 32-bit Modbus RTU Packet

Modbus Manual Version Modbus Manual for Clean Room Panel CRP5

COMMUNICATION MODBUS PROTOCOL

ENGLISH ENGLISH ENGLISH ENGLISH

4511 MODBUS RTU. Configuration Manual. HART transparent driver. No. 9107MCM102(1739) For 4511 devices from ser. no:

Elotech Standard Protocol. for Single R8200 SC

COMMUNICATION MODBUS PROTOCOL MF96001 / 021 NEMO 96HD

GE MDS, LLC. NETio Series. Protocol Communications Supplement. March 2013 Part No A01, Rev. C

Modbus on tsense. Table of contents:

ENGLISH ENGLISH ENGLISH ENGLISH

COMMUNICATION INSTRUCTION MANUAL Temperature Controller KT4R

Modbus _RTU (Memory Map)

CTT MODBUS-RTU COMMUNICATION PROTOCOL TEMPERATURE MONITOR DEVICE

Preface, Table of Contents

VersaChart MODBUS RTU Communication Protocol Partlow-West Company 2 Campion Road New Hartford NY 13413

SMARTRAIL X100 Protocol

For more information Contact with details of the application.

COMMUNICATION MODBUS PROTOCOL

Interface design document MODBUS Protocol. Ab s t r a c t Description of the MODBUS implementation for the Modbus I/O board

C192PF8-RPR. Power Factor Manager & Reactive Power Regulator Reference Guide. Modbus. Communications Protocol. BG0348 Rev. A1

Sample F4T 32-bit Modbus RTU Packet

DataVU 5 - Interface Manual Modbus

VISY-Command. Technical Documentation. with Modbus Protocol. Edition: Version: 1 Art. no.:

1.Eastron SDM530-Modbus Smart Meter Modbus Protocol Implementation V1.1

Revision 1.2. July 24, COM Protocol Manual. for MDC and ADC N 11th St - San Jose CA

DataVU 5 - Interface Manual Modbus

DirectNET Host. Communications Programs. In This Chapter...

Protocol VIT5. Communications RS485. Version 1.0. Pg.Up ENTER. Pg.Up ENTER. Pg.Up ENTER. Pg.Up ENTER. Pg.Up ENTER. Pg.Up ENTER. Pg.Up ENTER. Pg.

TORRIX RS485. Technical Documentation. with MODBUS Protocol. Edition: Version: 3 Art. no.:

MODBUS.ORG. Content 1 Introduction... 2

JCL-33A (C5) Warning. 1. System Configuration COMMUNICATION INSTRUCTION MANUAL

Rev 2.00 NA-9286 (EtherCAT) Page 1 of 31. FnIO S Series: NA EtherCAT Adapter

VPGate Manual PROFIBUS to serial

IQ Home Modbus-RTU Master

PFC96Evo / PFC144Evo CONTROLLER MODBUS PROTOCOL

THT-500-A/R (C5) 1. System Configuration COMMUNICATION INSTRUCTION MANUAL. No. THT5CE

NA-9171 / 9173 (RS-232) (RS-485) User Manual. MODBUS Adapter CREVIS Co.,Ltd. Version FnIO MODBUS Adapter NA-9171, NA-9173 FnIO S-Series

MPU-32 AND FPU-32 TIA-485 NETWORK

IF96017 MODBUS COMMUNICATION PROTOCOL

MODBUS APPLICATION PROTOCOL SPECIFICATION V1.1a CONTENTS

Modbus on K45 asense. Table of contents:

NXIO S Series: NXIO-MNA232, MNA485. MODBUS Adapter

FLOWSIC 600. Secification MODBUS

ENGLISH ENGLISH ENGLISH ENGLISH

The Roboteq Modbus Implementation User Manual

MODBUS Protocol Version

PM290 POWERMETER. Communication Protocols ASCII & Modbus Reference Guide

INTEGRA DL1 DUAL LOAD DIGITAL METER COMMUNICATIONS GUIDE DIGITAL ENERGY METER FOR MULTIPLE LOADS IN AN ELECTRICAL SYSTEM

Optris CT/ CTlaser/ CTvideo communication interface

Modbus Manual Version Modbus Manual for PF4/5

MCF. User's Manual. Air Flowmeter NPT Model. for Communication Functions. No. CP-SP-1301E

DTSX3000 Communications(Modbus) Guide

Modbus on SenseAir S8

EMS_ _Measure_MonoPh_R_2P_ModbusTable_LG_EN_v1.01.xlsx

T1 4-Channel Protocol Manual

SERIES PM130EH POWERMETERS COMMUNICATIONS REFERENCE GUIDE

2. Terminal arrangement TEMPERATURE CONTROLLER KT2 COMMUNICATION INSTRUCTION MANUAL. (Fig. 2-1)

PM130 Powermeters Reference Guide Modbus Communications Protocol

Automatic transfer switch

COMMUNICATION MODBUS PROTOCOL

BCT SERIES CONTROLLERS (VERSION 3.0) RS-485 COMMUNICATION INSTRUCTION MANUAL MODBUS Protocol Reference Guide

Data point description for the Modbus protocol. 4 quadrant controller. multicomp 6D6-ESMSBSDS-1V1C6RO. Your partner for network analysis

Communication protocols description of. Hx4xx and Hx3xx regulators with RS485 and RS232 communication interface

COMMUNICATION MODBUS PROTOCOL

VD SERIES CONTROLLERS (VERSION4.0) RS-485 COMMUNICATION INSTRUCTION MANUAL MODBUS Protocol Reference Guide

General Specifications

Transcription:

MODBUS M920 protocol description User s manual

CONTENT 1. BASIC INFORMATION 4 1.1. INTRODUCTION TO MODBUS 4 1.2. TRANSMISSION FORMAT 4 1.2.1. ASCII-MODE 4 1.2.2. RTU-MODE 5 2. SUPPORTED FUNCTIONS 7 2.1. READ COIL STATUS (FUNCTION 01) 7 2.2. READ INPUT STATUS (FUNCTION 02) 7 2.3. READ MULTIPLE HOLDING REGISTERS (FUNCTION 03) 7 2.4. READ INPUT REGISTERS (FUNCTION 04) 7 2.5. WRITE SINGLE COIL (FUNCTION 05) 7 2.6. WRITE MULTIPLE HOLDING REGISTERS (FUNCTION 16) 7 3. COMMANDS TABLE 8 3.1. TABLE 1 BIT VARIABLES (SINGLE COILS) 8 3.2. TABLE 2 INTEGER VARIABLES (HOLDING REGISTERS) 9 3.3. TABLE 3 LONG VARIABLES (HOLDING REGISTERS) 9 3.4. TABLE 4 TIME (LONG) VARIABLES (HOLDING REGISTERS) 10 3.5. TABLE 5 CHAR VARIABLES (HOLDING REGISTERS) 10 3.6. TABLE 6 FLOAT VARIABLES (HOLDING REGISTERS) 11 3.7. TABLE 7 STRING VARIABLES (HOLDING REGISTERS) 12 3.8. TABLE 8 DOUBLE VARIABLES (HOLDING REGISTERS) 13 Operation manual 3

1. Basic information 1.1. Introduction to Modbus This document specifies the MODBUS communications protocol as implemented on the magnetic flowmeter M920. This manual does not try to be a complete guide to the MODBUS protocol, but will show how to structure a message that the instruments will recognize. For Modbus communication is used RS-485 interface. Instruments communicate using a master-slave technique, in which only one device is the master and theslave devices supply the requested data when addressed. Typical master devices can be a host computer. Only the master can initiate transactions (requests), and only the addressed device responds. The Modbus request consist of: an address, a function code defining the requested action, data (if necessary for the requested function), and error check for testing the integrity of the message. The slave s response contains: the slave address, data conform the request type, and error check. If the data integrity test fails, no response is sent back. If a request cannot be processed an exception message is returned. 1.2. Transmission format There are two serial transmission modes for the MODBUS protocol, ASCII or RTU (Remote Transmission Unit) framing. The user has to select the desired protocol along with the serial communication parameters (baud rate, paritytype). Note that all these parameters must be the same for all instruments in the network. 1.2.1. ASCII-mode When device communicate on a MODBUS serial line using ASCII mode, each 8 bit byte in a message is sent as two ASCII characters. This mode is used when the physical communication link or the capabilities of the device does not allow the conformance with RTU mode requirements regarding timers management. Remark : this mode is less efficient than RTU since each byte needs two characters. The format ( 10 bits ) for each byte in ASCII mode is : Coding System: Hexadecimal, ASCII characters 0 9, A F. One hexadecimal character 4 Operation manual

Bits per Byte: contains 4-bits of data within each ASCII character of the message 1 start bit 7 data bits (least significant bit sent first) 1 bit for parity completion 1 stop bit The default parity mode is Even parity. Remark : the use of no parity requires 2 stop bits. ASCII Message framing: Start Address Function Data LRC End 1 char : 2 chars 2 chars 0 up to 2x252 char(s) 2 chars 2 chars CR, LF In ASCII mode, a message is delimited by specific characters as Start-of-frames and End-offrames. A message must start with a colon ( : ) character (ASCII 3A hex), and end with a carriage return line feed (CRLF) pair (ASCII 0D and 0A hex). In ASCII mode, messages include an error checking field that is based on a Longitudinal Redundancy Checking (LRC) calculation that is performed on the message contents, exclusive of the beginning colon and terminating CRLF pair characters. 1.2.2. RTU-mode When devices communicate on a MODBUS serial line using the RTU (Remote Terminal Unit) mode, each 8 bit byte in a message contains two 4 bit hexadecimal characters. The main advantage of this mode is that its greater character density allows better data throughput than ASCII mode for the same baud rate. Each message must be transmitted in a continuous stream of characters. The format ( 11 bits ) for each byte in RTU mode is : Coding System: 8 bit binary Bits per Byte: 1 start bit 8 data bits (least significant bit sent first) 1 bit for parity completion 1 stop bit The default parity mode is even parity. Remark : the use of no parity requires 2 stop bits. RTU Message framing: Start Address Function Data CRC End Operation manual 5

>= 3.5 char. 1 byt 1 byt 0 up to 252 byte(s) 2 bytes >= 3.5 char. In RTU mode, message frames are separated by a silent interval of at least 3.5 character times. The RTU mode includes an error checking field that is based on a Cyclical Redundancy Checking (CRC) method performed on the message contents. 6 Operation manual

2. Supported functions 2.1. Read coil status (Function 01) Function reads the ON/OFF status of discrete inputs or discrete (bit) variables in the instrument. Query contains the starting coil address and the quantity of coils to be read. 2.2. Read input status (Function 02) Function 1 and 2 perform the same action see description of Function 01. 2.3. Read multiple holding registers (Function 03) Function reads the binary contents of holding registers in the instrument. Query contains the starting registr address and the quantity of registers to be read. The maximum number of registers at each request is limited to 44 (RTU) or 22 (ASCII). Exception is double which can be read only one variable using this function. 2.4. Read input registers (Function 04) Function 3 and 4 perform the same action see description of Function 03. 2.5. Write single coil (Function 05) Function writes to a single coil value ON or OFF. ON value is presented as 0xff00, OFF value is presented as 0x0000. Command contains the coil address and requested value. The normal response is an echo of the, returned after the coil state has been changed. 2.6. Write multiple holding registers (Function 16) Function writes new values into a sequnce of holding registers. Command contains the register starting address, number of affected registers and requested values. The normal response contains number of changed registers. In this function can be write just one variable (integer, float, double...). Operation manual 7

3. Commands table Tables in this chapter contain following columns (description of variables): 1) Address 2) Name 3) Type 4) Access Read / Write 5) RS232 see description of this in the user s manual 3.1. Table 1 Bit variables (single coils) 0x1000 Negative flow direction bit R/W FFD 0x1001 Selftest bit R/W FIS 0x1002 Current loop test bit R/W FCE 0x1003 Current output status bit R RCE 0x1004 System error status bit R RES 0x1005 Dosing activity status bit R RDA 0x1006 Auxiliary volume clear bit R/W CLRAV 0x1007 Min. / max. flowrate clear bit R/W CLRMM 0x1008 Main volume clear bit R/W CLRVO 0x1009 Datalogger clear bit R/W DCLR 0x100a Dosing volume reset bit R/W CLRDO 0x100b Timed volume counter reset bit R/W CLRTV 0x100c Magnetic pointer control bit R/W FME 0x100d Dosing volume reset with restart bit R/W CLRDR 0x100e Empty pipe control bit R/W FEP Bit variables data format: ON is expressed as 0xff00 OFF is expressed as 0x0000 8 Operation manual

3.2. Table 2 Integer variables (holding registers) 0x3000 Nominal diameter integer R/W RDN 0x3001 Datalogger number of samples integer R DNR 0x3002 Datalogger filling (bytes) integer R DBT Integer variables data format: MSB LSB (most sign.bit) (least sign.bit) ----------------- ----------------- X X X X X X X X X X X X X X X X ----------------- ----------------- byte 1 byte 0 3.3. Table 3 Long variables (holding registers) 0x5000 Calibration password access setting long R/W FPC 0x5002 Password setting long W PSW 0x5004 Basic password access setting long R/W FPB 0x5006 Errors reading long R IER 0x5008 Mask for State Output error message long R/W SEM Long variables data format: MSB LSB (most sign.bit) (least sign.bit) X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X byte 3 byte 2 byte 1 byte 0 Operation manual 9

3.4. Table 4 Time (long) variables (holding registers) 0x5800 Time & date of the begin last finished time R RTB counting period (long) 0x5802 Time & date of the end last finished time R RTE counting period (long) 0x5804 Date and time of minimum flowrate time R RND (long) 0x5806 Date and time of maximum flowrate time (long) R RXD Time long variables data format: MSB LSB (most sign.bit) (least sign.bit) Y Y Y Y Y Y L L L L D D D D D H H H H H M M M M M M S S S S S S byte 3 byte 2 byte 1 byte 0 Where: Y: 0-63 year (2000-2063) L: 0-11 month (1-12) D: 0-30 day (1-31) H: 0-23 hour (0-23) M: 0-59 minute (0-59) S: 0-59 second (0-59) 3.5. Table 5 Charvariables (holding registers) 0x6000 Current output mode setting char R/W SCM 0x6001 Frequency output mode setting char R/W SFM 0x6002 Impulse output mode setting char R/W SPM 0x6003 State output mode setting char R/W SSM 0x6004 Digital input mode setting char R/W SIM 0x6005 Impulse width setting char R/W SPT 0x6006 Flowrate unit char R/W FFS 0x6007 Volume unit char R/W FVS 0x6008 Flowrate resolution char R/W FFR 0x6009 Volume resolution char R/W FVR 0x600a Time constant char R/W FTC 0x600b Datalogger step char R/W DST 0x600c Datalogger filling (percentage) char R DPC 10 Operation manual

0x600d Language setting char R/W FLG 0x600e Number of calibration points char R/W CPN 0x600f Backlight mode setting char R/W FDB 0x6010 Contrast setting char R/W FDC 0x6011 Message time setting char R/W FDM 0x6012 Timed volume counting period char R/W FTI 0x6013 Week begin char R/W FTW 0x6014 Date format setting char R/W FDF 0x6015 Actual access level char R/W PAL 0x6016 Power supply type char R/W PPW Char variables data format: MSB LSB (most s.bit) (least s.bit) ----------------- X X X X X X X X ----------------- byte 0 3.6. Table 6 Float variables (holding registers) 0x7000 Current output constant QI setting float R/W SCO 0x7002 Frequency output constant QF setting float R/W SFO 0x7004 Impulse output constant QP setting float R/W SPO 0x7006 Dosing constant QD setting float R/W SIO 0x7008 Fixed current setting float R/W SFC 0x700a Fixed frequency setting float R/W SFF 0x700c Low limit value PF1 setting float R/W SF1 0x700e High limit value PF2 setting float R/W SF2 0x7010 Hysteresis setting float R/W SHY 0x7012 Conversion constant for flowrate user unit float R/W FFC 0x7014 Conversion constant for volume user unit float R/W FVC 0x7016 Low flow cutoff float R/W FLF 0x7018 Actual flowrate float R RFL 0x701a Maximum flowrate float R RMX 0x701c Minimum flowrate float R RMN 0x701e Nominal flowrate float R/W RQN 0x7020 Electroni unit (display) temperature float R IT 0x7022 Nominal value of calibration point 1 float R/W CX1 0x7024 Calibration constant for calibration point 1 float R/W CY1 0x7026 Nominal value of calibration point 2 float R/W CX2 0x7028 Calibration constant for calibration point 2 float R/W CY2 Operation manual 11

0x702a Nominal value of calibration point 3 float R/W CX3 0x702c Calibration constant for calibration point 3 float R/W CY3 0x702e Nominal value of calibration point 4 float R/W CX4 0x7030 Calibration constant for calibration point 4 float R/W CY4 0x7032 +5V power supply float R IU1 0x7034 +15V power supply float R IU2 0x7036-15V power supply float R IU3 0x7038 Excitation coils resistance float R ICO 0x703a Excitation coils temperature float R ICT 0x703c Actual dosing volume float R RDO 0x703e Minimum allowed coil temperature float R/W FTL 0x7040 Maximum allowed coil temperature float R/W FTH Float variables data format: MSB LSB (most sign.bit) (least sign.bit) S E E E E E E E E M M M M M M M M M M M M M M M M M M M M M M M byte 3 byte 2 byte 1 byte 0 Where: S: sign bit where 1 is negative and 0 is positive E: exponent with an offset of 127 M: 24-bit mantissa (stored in 23 bits) The mantissa is a 24-bit value whose most significant bit (MSB) is always 1 and is, therefore, not stored. 3.7. Table 7 String variables (holding registers) 0x8000 Device identification string[10] R IDN 0x8005 Flowrate unit user text string[4] R/W FFU 0x8007 Volume unit user text string[4] R/W FVU 0x8009 Time setting string[8] R/W FTM 0x800d Date setting string[10] R/W FDT String variables data format: String variables have defined length (see table above) and consists of ASCII characters. One byte represents one character. 12 Operation manual

3.8. Table 8 Double variables (holding registers) 0x9000 Volume double R RVO 0x9004 Volume positive double R RVP 0x9008 Volume negative double R RVN 0x900c Volume auxiliary double R RVA 0x9010 Timed volume finished double R RVT 0x9014 Timed volume actual double R RTA Double variables data format (decimal/64 data format) MSB (most sign.bit) S C C C C C E E E E E E E E M M M M M M M M M M M M M M M M M M byte 7 byte 6 byte 5 byte 4 LSB (least sign.bit) M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M M byte 3 byte 2 byte 1 byte 0 Where: S: sign bit where 1 is negative and 0 is positive C: combination field E: 8-bit exponent continuation with an offset of 398 M: 50-bit mantissa continuation Combination field: Combination field (5 bits) Type Exponent MSBs (2 bits) a b c d e Finite a b 0 c d e 1 1 c d e Finite c d 1 0 0 e 1 1 1 1 0 Infinity - - - - - - 1 1 1 1 1 NaN - - - - - - Example: Coefficient MSD (4 bits) In this format, the finite number 7.50 would be encoded as follows: The sign is 1 indicating that the number is negative. The coefficient will be 750, with 13 leading zeros. This is encoded with the first digit (0) in the combination field, and the remaining 15 digits in the coefficient continuation field (four 10-bit groups of all zero bits and the final group being the encoding of 750, which is the ten bits 11 1101 0000). The exponent will be 2, so the encoded exponent is this plus the bias, or 396. This is 01 1000 1100 in binary, with the first two bits being embedded in the combination field and the remainder being placed in the exponent continuation field. Operation manual 13

The bits of the combination field are therefore 01000 (the last three bits are 0 because the most significant digit of the coefficient is 0). The full encoding is therefore (in hexadecimal, shown in network byte order): A2 30 00 00 00 00 03 D0 14 Operation manual