Analog Door Phone Model LUADS

Similar documents
SERVICE MANUAL MODEL WPP-531-X-ADA MODEL SSP-511- X-ADA

SERVICE MANUAL MODEL SSW-520-F

L1-34A February ADP-40 Analog Door Phone Hardware Installation Guide

SERVICE MANUAL FOR MODEL WPP-531-D WEATHERPROOF TELEPHONE WITH OPTIONAL ADA FEATURE

SERVICE MANUAL MODEL SSP-350-X

PARTNER Contact Closure Adjunct

SERVICE MANUAL FOR MODEL WPP-531-D WEATHERPROOF TELPHONE OR MODEL HOB-531-D WEATHER RESISTANT TELPHONE

SERVICE MANUAL FOR MODEL WPP-531-D2 WEATHERPROOF TELEPHONE OR MODEL HOB-531-D2 WEATHER RESISTANT TELEPHONE

SERVICE MANUAL MODEL SSW-521-D2-ADA

SERVICE MANUAL FOR MODEL WPP-531-X-ADA-STROBE WEATHERPROOF TELEPHONE WITH OPTIONAL STROBE FEATURE. EQUIPPED WITH SPK1.

SERVICE MANUAL MODEL SSP-561-X-ADA

LOOP-IP 6100 Series High Speed Ethernet Interface Unit Users Manual for: Loop-IP 6100-DS3 Loop-IP 6100-DS3R Loop-IP 6100-E3 Loop-IP 6100-E3R

SERVICE MANUAL FOR. MODEL MHW-341-Fr1 MAGNETIC HOOKSWITCH WALL TELEPHONE

SERVICE MANUAL MODEL SSW-521-F (FORMERLY SSW-521-FS)

SERVICE MANUAL MODEL WPP-331-D WEATHERPROOF TELEPHONE MODEL HOB-331-D WEATHER RESISTANT TELEPHONE. and MODEL SSP-311-D STAINLESS STEEL PANEL TELEPHONE

SAT SELECT ENTRY SYSTEMS. User / Installer Guide. Dec 08 SAT3 SAT3/D

FEATURES. AlphaBlueLight Emergency Towers Installation & Operations Manual FIGURE 1: FRONT & REAR VIEWS

OPERATING INSTRUCTIONS PA AMPLIFIER P-1812

BASIC PA AMPLIFIER A-1031 A-1061 A-1121 OPERATING INSTRUCTIONS TABLE OF CONTENTS

SERVICE MANUAL MODEL SSW-321-D

28-Position 23 Rack Mounting Model RM23-20X

SERVICE MANUAL MODEL SSP-550-X (FORMERLY SSP-510-X)

Service Manual For. -IP Voice over Internet Protocol -ACH** Handset cord length Inches

Four IFB. Multi Line Phone Bridge. User Guide. JK Audio. Warranty

SERVICE MANUAL. MODEL SSW-321-Fr1

2 Channel POTS DIN Fiber Link System

User Manual WDP-174LM / WDR-174DS

V-9939C MICROPHONE ADAPTER

Model 2657A-LIM-3 LO Interconnect Module

INFORMATION AMPLIFIER TA-102 OPERATING INSTRUCTIONS TABLE OF CONTENTS

Model HM-535 Power Supply Installation and Service Instructions

TELIKOU Intercom System. FM Wire Matrix Control Station. Instruction Manual

SERVICE MANUAL MODEL SSP-363-E (FORMERLY SSP-365-E)

2 Channel POTS with I/O DIN Fiber Link System

MCCB-250 MOLDED-CASE CIRCUIT BREAKER TESTER

SERVICE MANUAL FOR MODEL SSC-500-F (FORMERLY 501-FSZ) STAINLESS STEEL HANDS FREE CHARGE-A-CALL TELEPHONE EQUIPPED WITH LOW-POWER SPEAKER BOARD

SS91A-M GSM DOOR PHONE (ACCESS CONTROL SYSTEM)

HCS-3600 / 3602 / 3604 Laboratory Grade & High RFI Immunity Switching Mode Power Supply with Rotary Encoder Control

BS 181 SINGLE CHANNEL POWER SUPPLY USER MANUAL

Multiple Digital Messaging Unit

1. Safety Precautions (Read these precautions before use.)

PS8 - II. Professional Power Sequencer. User s Manual

Model 8020-STC. Kelvin Standard Triaxial Connector Card. Description / October 2014 *P * 1

PS 289 DUAL CHANNEL POWER SUPPLY USER MANUAL

Installation and User Instructions

BS 287 DUAL CHANNEL POWER SUPPLY. User Manual. January 2017 V1.0

SERVICE MANUAL MODEL SSW-321-X

ICM-25 INPUT CONTROL MODULE, 25 INPUTS RS-232(SERIAL) OUTPUT

Installation of the POTS splitter card requires the following steps: Determining the cables you need. Installing the POTS splitter chassis

CIB 3125 (122A) Off-Premises Range Extender. Installation Instructions. Installed By Qualified Technician Only CIB

SERVICE MANUAL MODEL SSW-321-F MODEL BLW-321-F

Model 8020-KHV. Kelvin Keithley Triaxial Connector Card. Description / October 2014 *P * 1

VIEW. SLX300 SpeakerLinX. Installation and Setup Guide. AVoIP

IA3100. Administrator Guide. Legacy Speakerphone. Installation Configuration Operation Troubleshooting

SERVICE MANUAL MODEL SSC-303-F (FORMERLY 303-FS)

PANEL MOUNT INTERCOMS

MODEL CMX-300. Technical Practice October 2015 Issue 6. Service Observing System 1. GENERAL 2. DESIGN FEATURES 3. OPERATION CONTENTS: Model CMX-300

SuperBus 2000 Phone Interface/Voice Module Installation Instructions

Service Manual For. -IP Voice over Internet Protocol -ACH** Handset cord length Inches

Section A5. Standard Telephone Entry Systems. This Price Schedule is effective April 1, Date Page Comment

Kogan Bluetooth Karaoke System with Dual Microphones KAKAR2MICA

Tone Generator and Probe

DATA CONNECT ENTERPRISE

AREA CODE CHANGE. Please note that the area code for Paradyne Corporation in Largo, Florida has changed from 813 to 727.

1. Installation. 2. Configuration - Operation. 3. Specifications. Safety

OPERATING PROCEDURES for the UPS-S2 Universal Power Supply Series 2

OWNER'S MANUAL. Model:PSV Amp SWITCHING DC POWER SUPPLY.

EntraGuard Bronze. Quick Start Guide. Telephone Entry. 1.0 Specifications. 2.0 Unit Installation

Area of Rescue Command Unit Installation Instructions Model AOR-8 / Model AOR-16

User Manual Color Door Camera

Section 1 Basic System Construction. 1.1 Product Specification

VE8012A/VE8012AR DUAL NETWORKED STATION PORT

508 SERIES MICROPHONE STATIONS

CG800H SERIES USER MANUAL ZIGBEE WIRELESS SCENE CONTROL PANEL VERSION JANUARY, Disclaimers and Copyright

LVDT Test Device. Product Manual (Revision B) Original Instructions. Testing and Calibration of LVDT Feedback Devices on PG Governors

345 Encinal Street Santa Cruz, CA

Audio Input Card Installation Instructions

PICTURE PHONE WITH ONE TOUCH DIALING MODEL: FC-0613

User Manual. GUARD STATION(Gate View System) CDS-4GS

MODEL 805 USER MANUAL

USER MANUAL. 4.3 Video Door Phone

SERVICE MANUAL MODEL SSC-301-F (FORMERLY 301-FS) MODEL BLC-301-F (FORMERLY 301-F)

SS91A-M GSM DOOR PHONE (ACCESS CONTROL SYSTEM)

forté Compatible Compatible Simple, Secu re, Stylish... USER GUIDE AND INSTALLATION MANUAL electronics

i30 SIP Video Door Phone Quick Installation Guide

Troubleshooting Guide for Firecom Intercoms

E SERIES USB ANALOG USER GUIDE. For E100 USB, E100LBY USB, E100TRM, E200 USB, E200TRM, E103 USB, E103 RediDock USB, E203 USB, E203 RediDock USB

121000TP227S USER'S MANUAL

FUTURE CALL. Future Call Model FC-1204 Totally Hands Free Voice Activated Dialing and Answering Telephone OWNER S MANUAL AND OPERATING INSTRUCTIONS

DBPApplication. PD Devices Ltd. Unit 1, Old Station Yard, South Brent, Devon. TQ10 9AL (0)

PCM60A 100W MAX P.A. AMPLIFIER.

USER MANUAL. 7 Touch Screen Video Door Phone

TPE 1464 Series Pressure Transducer

MODEL: M5DY SEN TRONIC AG CURRENT LOOP SUPPLY. [2] POWER INPUT AC Power M: V AC (Operational voltage range V, Hz)

Big button Speakerphone MODEL: FC-8814

4 Channel POTS Fiber Link Card System

CDR1. CD Player with AM/FM Radio Receiver. Userʼs Manual. Specifications. FM Tuner. 300-ohm Dipole type. AM Tuner. Audio Section.

1.6. Counters, Panel Meters, Tachometers and Timers. Contents Description Fusion Integrated Machine Control Standards and Certifications...

AirTest Model CN9000 Series Sensor Controller

CVU-200-KIT. 200 V Bias Tee Kit. Description. Parts list / October 2014 *P A* 1

Transcription:

Analog Door Phone Model LUADS Installation and Use Manual Telephone line powered Two-way, hands-free communication Vandal-resistant brushed stainless steel faceplate with mounting gasket and heavy-duty call button Adjustable microphone and speaker volume Adjustable call timer duration Defeatable call timer Responds to forward disconnect Selectable Auto Answer feature allows remote monitoring Issue 1, December 2003 2003 Bogen Communications, Inc. All rights reserved. 54-2106-01A 0312 Printed in Taiwan. Specifications subject to change without notice.

Notice Every effort was made to ensure that the information in this manual was complete and accurate at the time of printing. However, information is subject to change. Important Safety Information Always follow these basic safety precautions when installing and using the system: 1. Read and understand all instructions. 2. Follow all warnings and instructions marked on the product. 3. DO NOT block or cover the ventilation slots and openings. 4. Never spill liquid on the product or drop objects into the ventilation slots and openings. Doing so may result in serious damage to the components. 5. Repair or service must be performed by a factory authorized repair facility. 6. DO NOT install telephone wiring during a lightning storm. 7. DO NOT install telephone jacks in a wet location unless the jack is specifically designed for wet locations. 8. Never touch uninsulated wires or terminals, unless the line has been disconnected at the paging or controller interface. 9. Use caution when installing or modifying paging or control lines. Service Requirements In the event of equipment malfunction, all repairs should be performed by Bogen or an authorized agent. It is the responsibility of users requiring service to report the need for service to Bogen or to one of our authorized agents. Service can be facilitated through our office at: Bogen Communications, Inc. 50 Spring Street, Ramsey, NJ 07446, USA Tel. 1-800-999-2809 Bogen s Applications Department may be reached at: 1-800-999-2809. 2

Package Contents (1) LUADS (1) Dual gang electrical box (4) Panel screws (1) Hex wrench Features Auto Answer The LUADS can be programmed to automatically answer an incoming call.this feature can be enabled or disabled using a jumper. Timer Duration The LUADS can be programmed to automatically disconnect a call after a preset amount of time has elapsed.the timer can be set between 15 seconds and 2 minutes. When the call is initiated by the unit, then the timer starts as soon as the button is pushed. When the call is initiated by another phone (Auto Answer), then the timer starts once the unit answers the call. With the timer disabled, the call time will be unlimited and the LUADS will not disconnect the call until a 300 ms or longer loss of loop current is detected. If your telephone line/phone system extension does not supply a loop current break when the calling party hangs up, then the call timer feature must be used (enabled). Speaker Volume Adjusts the speaker volume of the unit. Microphone Level Adjusts the microphone return talk level of the unit. In certain noisy locations (e.g., background traffic, machinery, or wind) the microphone threshold level may need to be decreased, otherwise the unit might pickup the background noise thereby causing the unit to remain in the talk mode. Active LED When lit, the LED indicates that the unit is active (off-hook).active LED is intended for diagnostic use only. 3

Programming TEL Line Connector - Analog station line connection (Tip and Ring) is made via an RJ11 connector that is pre-wired to a 2-position pluggable terminal block. Not polarity sensitive. Auto Answer Feature - The Auto Answer feature can be enabled or disabled depending on where the jumper is set. Timer - The Timer feature is jumper selectable and can be enabled or disabled. Speaker Volume - The Speaker Volume POT can be adjusted to increase or decrease the speaker volume to the desired level. Mic Level - A Mic Level POT is provided on the LUADS for increasing or decreasing the microphone return talk level. Timer Duration - The LUADS is equipped with an adjustable call timer duration feature that automatically hangs up the unit after the preset time has elapsed. 4

Wiring Phone Connection To connect the LUADS to a phone system, simply connect the analog station line to the RJ11, which is already wired to a pluggable terminal block that is preassembled to the circuit board.the connections to the terminal block are not polarity sensitive. Surge Protection To increase surge protection, connect a protective Earth Ground to the spare lug provided.the location of the spare lug is shown below. 5

Installation The LUADS comes with a standard dual gang electrical box. Make all electrical connections prior to installing the LUADS into the electrical box. Surface Mounting the LUADS (Indoor/Outdoor) 1. Mount electrical box. 2. Make electrical connections (see Wiring) and attach the faceplate to the electrical box using the four hex drive screws (tool provided). 6

Specifications Power: Telephone line powered (18V DC / 20 ma minimum) Timer Duration: 15 seconds to 2 minutes Loop Current Loss Disconnect: 300 ms minimum Ring Voltage: 40V AC RMS minimum REN: 0.7A Connections: RJ11 pre-wired to a 2-position pluggable terminal block Earth Ground lug Dimensions: 5" W x 5" H x 2 1 /4" D (fully assembled) 4 5 /8" W x 4 5 /8" H x 2" D (aluminum box) Product Weight: 4 lb. 7