RTD Input Module HE800RTD000 / HE800RTD100 HE-RTD000 / HE-RTD100* * HE- denotes plastic case.

Similar documents
Temperature I/O Module HE800MIX963 / HE-MIX963* * HE- denotes plastic case.

4-20 ma Analog Input Module HE800ADC020 / HE800ADC120 HE-ADC020* / HE-ADC120* 12-Bit Resolution * HE-denotes plastic case.

Thermocouple / Millivolt Input Module HE800THM000 / HE800THM100 HE-THM000 / HE-THM100* * HE- denotes plastic case.

24VDC Bipolar Digital In 10-28VDC, 0.5A Sourcing Digital Out 4-20mA Analog In/Out HE800MIX902 / HE-MIX902* * HE- denotes plastic case.

Thermistor / Current / Voltage Analog Input Module HE800ADC920 / HE-ADC920* 12-Bit Resolution * HE- denotes plastic case.

DeviceNet Master (Scanner) HE800DNT450 / HE-DNT450* DeviceNet Communications * HE- denotes plastic case.

4-20mA Analog Output Module HE800DAC002 / HE800DAC102 HE-DAC002* / HE-DAC102* 14-Bit Resolution * HE- denotes plastic case.

24VDC Bipolar Digital In 10-28VDC, 0.5A Sourcing Digital Out 0-20mA Sourcing Analog In/ Out HE800MIX906 / HE-MIX906* * HE- denotes plastic case.

SmartBlock I/O Module HE579MIX577/977 Isolated 4/8 Analog Inputs 2/4 Analog Outputs

SmartBlock I/O Module HE579MIX102 Isolated 6 Relay, 12 DC Inputs, 4 Analog Inputs

AC Input /AC Output. Module

Thermistor / Current / Voltage Analog Input Module HE800ADC920 / HE820ADC920* 12-Bit Resolution * HE820 denotes plastic case.

QX751 CANOpen HEQX751C203/HEQX751C205 HE-BP41/HE-BP43 Back Pack Module

Specifications / Installation. QX Series Models:

SmartRail I/O Ethernet Base HE599ETX300

SmartMod DC Digital Input Module HE359DIM610 12/24VDC Negative Logic

MAN October 2010 PAGE 1 HE-579ACM300 SmartBlock Power and Energy Monitor HE-579ACM300

XL7 OCS Datasheet for HE-XW1E0, HE-XW1E2, HE-XW1E3, HE-XW1E4, HE-XW1E5 HEXT391C100, HEXT391C112, HEXT391C113, HEXT391C114, HEXT391C115

Specifications / Installation. Specifications Digital DC Inputs XL103 XL104 Digital DC Outputs XL103 XL104

XL4 OCS DATASHEET MODEL DC In, 12 DC Out, 2 12-bit Analog In. Serial Ports. USB mini-b USB A. CAN Port Isolated 1 kv.

MAN MAY 2003 PAGE 1 OCX VDC Bipolar Digital In 10-28VDC, 0.5A Sourcing Digital Out ±10V, ±20mA Analog In/Out HE500OCX404 / HE500RCX404

Tempco Instruction Manual

HE-XE102, HE-XE103/ HE-XE104, HE-XE105

XL4 OCS Datasheet for HE-XC1E0, HE-XC1E2, HE-XC1E3, HE-XC1E4, HE-XC1E5 HEXT251C100, HEXT251C112, HEXT251C113, HEXT251C114, HEXT251C115

XL4 OCS DATASHEET MODEL DC In, 6 Relay Out, 4 12-bit Analog In. Serial Ports. USB mini-b USB A. CAN Port Isolated 1 kv. Gen.

Thermocouple Input Module Product Specifications and Installation Data

XLe/XLt OCS. User Manual for

Model 2460-KIT. Screw Terminal Connector Kit. Description / September 2014 *P * 1

MICRO V PAC II. Versatile Process Automation Controller II. Copyright Healy-Ruff Company, LLC 2710 Summer Street NE Minneapolis MN 55413

Installation Requirements for Conformance to Standards

Model 8020-KHV. Kelvin Keithley Triaxial Connector Card. Description / October 2014 *P * 1

IMPORTANT PRODUCT INFORMATION

Advanced Ladder Logic Required Power 24VDC. Full IEC Languages (Steady state) (heater duty cycle) 24VDC

Model 8020-STC. Kelvin Standard Triaxial Connector Card. Description / October 2014 *P * 1

Model 7705 Control Module

Supplement for HE800ETN200, HE800ETN300 HE-ETN200, HE-ETN300. SmartStack Ethernet Modules SUP

SLATE. Digital I/O Module INSTALLATION INSTRUCTIONS R8001D4001

Model 8010 High Power Device Test Fixture Interconnection Reference Guide

SAVE THESE INSTRUCTIONS

General Specifications. P2-08THM Analog Input

Analog Voltage Combination Module

DTS 310. DIN Rail Mounted, Indoor Rated Revenue Grade Electrical Sub-meter. Page 1. Measurlogic MQ A

Installation Instructions

Model 2600B-PM V Protection Module with 1 A Clamp. Description / April 2015 *PPA * 1

Model 2657A-LIM-3 LO Interconnect Module

Expansion Module HZS 541-1S

SINAMICS G130. Terminal Module 150 (TM150) Operating Instructions 03/2013 SINAMICS

Models 2601B, 2602B, and 2604B System SourceMeter Instruments Quick Start Guide

ACCESS 9340/9360 Meter Input/Output Module

Twido Programmable Controllers

This 4200-RM Rack Mount Kit is for installation in 4200-CAB series cabinets only.

Control & Logic Specifications Required Power 24 VDC (355mA with heater operating).

General Specifications. P2-08NTC Thermistor. The P2-08NTC module provides eight Thermistor input channels for use with the Productivity2000 System.

User Manual for IC300ETN100. SmartStack Ethernet Module. August 01, 2000 GFK FANUC Spares

P3-SCM. General Specifications

V E2B Snap-in I/O Module

OTB1S0DM9LP I/O distributed module OTB - Modbus non isolated serial link m

Electrical. SPECIFICATIONS SH Cable

V E1B Snap-in I/O Module

Supplement for HE800ETN200, HE800ETN300 HE-ETN200, HE-ETN300. SmartStack Ethernet Modules. 15 July 2009 SUP

P2-04AD Analog Input. Removable Terminal Block Specifications

Twido Programmable Controllers Discrete I/O Modules

Operating Instructions. For. Level Control Module. Model SSR 1000

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

OTB1C0DM9LP I/O distributed module OTB - CANopen bus m

OTB1C0DM9LP. Main , length of segment <= 185 m , length of segment <= 160 m. 3.4 kohm for I8...I kohm I0...I1 5.7 kohm I6...

User safety and equipment protection guidelines

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

Table 1 Specifications Software Required for Configuration

SINAMICS G130. Voltage Sensing Module 10 (VSM10) Operating Instructions 05/2010 SINAMICS

Installation manual for for Schleifenbauer DPM3

CTI 2552-A 8-CHANNEL ISOLATED RTD INPUT MODULE INSTALLATION AND OPERATION GUIDE. Ver. 1.2 CTI Part #

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

Operating instructions. Switching amplifier DN0210 DN / / 2015

P2-HSO High-Speed Isolated Sinking/Sourcing Output. Connector Specifications

Mini Digital Multimeter

CVU-200-KIT. 200 V Bias Tee Kit. Description. Parts list / October 2014 *P A* 1

Model Number Structure

NX-series SSI Input Unit. Read position information from encoders with Synchronous Serial Interface (SSI). Features. System Configuration

Analog Input Module. ST-3xxx. User Manual CREVIS Co.,Ltd. Version FnIO S-Series

OTB1C0DM9LP I/O distributed module OTB - CANopen bus m

CAN Fiber Optic Modem

SAVE THESE INSTRUCTIONS

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

CVU-3K-KIT. 3 kv Bias Tee Kit. Description. Parts list / October 2014 *P * 1

Operating Instructions. Power Supply & Isolation Relay for Switches Model: RL manual_rl-5900_0215

PRO1250D CT MID DIN rail three phase four wire energy meter. User manual Version 1.5

DM-918 OPERATIONS MANUAL AUTORANGING MULTIMETER

Specifications, Installation, and Operating Instructions

Conductive Level Controller

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions

UNT1100 Series. Binary Output Jumpers AO2 AO1 AO3 AO4 AOCM AOCM AOCM AOCM AO1. AI Switches Job Information N2 Address. Ref N2+ N2- ADDR 0 = ALL OPEN

Time Counters mini "h", DC Version

PRODUCT SPECIFICATION. PC Board Relays. Series.

Commander LI90 Series. Controller

WOODINVILLE, WA SUPERSTEP 2100 SERIES SEQUENCING PROPORTIONAL LOAD CONTROLLERS INSTALLATION & OPERATING MANUAL. Models: SLC2102-SLC2112

IGLOO IGLOO EASY INSTRUCTION MANUAL

IGLOO IGLOO EASY INSTRUCTION MANUAL

H Series PLC. ! : Indicates Compulsion. EH-150 Analog input module EH-AXH8M Instruction manual. Safety precautions DANGER CAUTION COMPULSION

DANGER DANGER: is used in this manual to warn of high voltages capable of causing shock, burns, or death.

Transcription:

MAN0236-09 10 NOV 2006 PAGE 1 RTD Input Module HE800RTD000 / HE800RTD100 HE-RTD000 / HE-RTD100* * HE- denotes plastic case. This datasheet also covers products starting with IC300. 1 SPECIFICATIONS RTD000 RTD100 RTD000 RTD100 Number of Channels Required Power 2 4 (Steady State) 0.10W (4.2mA @ 24VDC) RTD Types 100, 200, 500, 1000 Ohms Required Power at 0 C, Platinum, Alpha (Inrush) Negligible 0.00385, DIN43760 Average RTD Current 0.44mA (100 Ohm Range) Input Range -200 C to +850 C I/O Points Required 2 4 Input Impedance >100Meg Ohm 0-4VDC Clamped @ 0 and 4VDC Converter Type Integrating RTD Excitation Current 2.2, 1.1, 0.44, 0.22mA, 25% duty cycle Types Supported DIN43760 RTD Short Indefinite Accuracy ± 0.5 C Resolution 0.05 C Channel-to-Channel Operating 0.1 C 0 to 60 Celsius Tracking Temperature 5 to 95% Non-condensing Update Time 16 channels/second Relative Humidity Input Transient Protection Zener/Capacitor Terminal Type Spring Clamp, Removable Notch Filter CE UL 50-60 Hz. Software Selectable Weight 9.5 oz. (270 g) See Compliance Table at http://www.heapg.com/support/compliance.htm

PAGE 2 10 NOV 2006 MAN0236-09 * 2 WIRING OCS Bottom View Shows Corresponding I/O Pin 1E 1S 1C 2E 2S 2C 3E 3S 3C 4E 4S 4C * Pin Signal RTD100 RTD000 1E RTD1 Excitation RTD1 Excitation 1S RTD1 Sense RTD1 Sense 1C RTD1 Common RTD1 Common 2E RTD2 Excitation RTD2 Excitation 2S RTD2 Sense RTD2 Sense 2C RTD2 Common RTD2 Common 3E RTD3 Excitation 3S RTD3 Sense 3C RTD3 Common 4E RTD4 Excitation 4S RTD4 Sense 4C RTD4 Common 001RTD001 3 CONFIGURATION Note: The status of the I/O can be monitored in Cscape Software. Preliminary configuration procedures that apply to SmartStack Modules are contained in the hardware manual of the controller you are using. Refer to the Additional References section in this data sheet for a listing of hardware manuals. Module Setup Tab a) Sensor Type for each channel may be selected independently. b) Temperature format may be set for various C or F ranges. c) Filter Constant sets the level of digital filtering according to the chart below. d) Reject Rates sets the frequency level for noise rejection at 50 or 60HZ. I/O Map Tab The I/O Map describes which I/O registers are assigned to a specific SmartStack Module and where the module is located in the point map. The I/O Map is determined by the model number and location within the SmartStack. The I/O Map is not edited by the user.

MAN0236-09 10 NOV 2006 PAGE 3 0 1 2 3 4 5 6 7 Filter Constant %Complete [ ] 100 90 80 70 60 50 40 30 20 10 0 0 250ms 500ms 750ms 1000ms 1250ms Scans Digital Filtering. The illustration above demonstrates the effect of digital filtering (set with Filter Constant) on module response to a temperature change. 4 TEMPERATURE CONVERSION For a given module configuration, use the appropriate formula in the table to obtain the actual temperature ( C or F) that is represented by the value in the %AI register. Module Temperature Conversion Configuration Celsius Fahrenheit 0.05 C = %AI / 20 F = %AI / 20 0.1 C = %AI / 10 F = %AI / 10 0.5 C = %AI / 2 F = %AI / 2

PAGE 4 10 NOV 2006 MAN0236-09 5 INSTALLATION / SAFETY Warning: Remove power from the OCS controller, CAN port, and any peripheral equipment connected to this local system before adding or replacing this or any module. a) All applicable codes and standards should be followed in the installation of this product. b) ed wiring should be used for best performance such as Omega EXTT-3CU-26S or equivalent. c) s may be terminated at the module terminal strip. d) In severe applications, shields should be tied directly to the ground block within the panel. e) Interposing electrical devices (such as relays) in the signal path can cause errors due to resistive imbalance. For detailed installation and a handy checklist that covers panel box layout requirements and minimum clearances, refer to the hardware manual of the controller you are using. (See the Additional References section in this document.) When found on the product, the following symbols specify: Warning: Consult user documentation. Warning: Electrical Shock Hazard. WARNING: To avoid the risk of electric shock or burns, always connect the safety (or earth) ground before making any other connections. WARNING: To reduce the risk of fire, electrical shock, or physical injury it is strongly recommended to fuse the voltage measurement inputs. Be sure to locate fuses as close to the source as possible. WARNING: Replace fuse with the same type and rating to provide protection against risk of fire and shock hazards. WARNING: In the event of repeated failure, do not replace the fuse again as a repeated failure indicates a defective condition that will not clear by replacing the fuse. WARNING: Only qualified electrical personnel familiar with the construction and operation of this equipment and the hazards involved should install, adjust, operate, or service this equipment. Read and understand this manual and other applicable manuals in their entirety before proceeding. Failure to observe this precaution could result in severe bodily injury or loss of life.

MAN0236-09 10 NOV 2006 PAGE 5 For detailed installation and a handy checklist that covers panel box layout requirements and minimum clearances, refer to the hardware manual of the controller you are using. (See the Additional References section in this document.) All applicable codes and standards need to be followed in the installation of this product. For I/O wiring (discrete), use the following wire type or equivalent: Belden 9918, 18 AWG or larger. Adhere to the following safety precautions whenever any type of connection is made to the module. Connect the green safety (earth) ground first before making any other connections. When connecting to electric circuits or pulse-initiating equipment, open their related breakers. Do not make connections to live power lines. Make connections to the module first; then connect to the circuit to be monitored. Route power wires in a safe manner in accordance with good practice and local codes. Wear proper personal protective equipment including safety glasses and insulated gloves when making connections to power circuits. Ensure hands, shoes, and floor are dry before making any connection to a power line. Make sure the unit is turned OFF before making connection to terminals. Make sure all circuits are de-energized before making connections. Before each use, inspect all cables for breaks or cracks in the insulation. Replace immediately if defective.

PAGE 6 10 NOV 2006 MAN0236-09 6 ADDITIONAL REFERENCES The following information serves as a general listing of Horner controller products and other references of interest and their corresponding manuals numbers. Visit our website listed in the Technical Support section to obtain user documentation and updates. Note: This list is not intended for users to determine which products are appropriate for their application; controller products differ in the features that they support. If assistance is required, see the Technical Support section in this document. Controller XLE Series (e.g., HE-XExxx) QX Series (e.g., HE-QXxxx) NX Series (e.g., HE-NXxxx) LX Series (e.g., LX-xxx; also covers RCS116) Color Touch OCS (e.g., OCSxxx) OCS (Operator Control Station) (e.g., OCS1xx / 2xx; Graphic OCS250) Remote Control Station (e.g., RCS2x0) MiniOCS (e.g., HE500OCSxxx, HE500RCSxxx) Other Useful References CAN Networks Cscape Programming and Reference Wiring Accessories and Spare Parts Manual DeviceNet Implementation Wiring Accessories and Spare Parts Manual Manual Number MAN0805 MAN0798 MAN0781 MAN0755 MAN0465 MAN0227 MAN0305 MAN0799 MAN0313 MAN0347 SUP0326 MAN0347 7 TECHNICAL SUPPORT For assistance and manual up-dates, contact Technical Support at the following locations: North America: (317) 916-4274 www.heapg.com Europe: (+) 353-21-4321-266 www.horner-apg.com