Messaging module CP-C MM

Similar documents
Electronic timer CT-SDD.22 Star-delta change-over with 2 n/o contacts

Electronic timer CT-EBD.12 Flasher starting with ON with 1 c/o (SPDT) contact

Switching relay CT-IRE with 1 c/o (SPDT) contact

Electronic timer CT-ARE OFF-delayed without auxiliary voltage, 1 c/o (SPDT) contact

Redundancy unit CP-A RU

Voltage monitoring relays CM-ESS.1 For single-phase AC/DC voltages

Electronic timer CT-ARS.21 OFF-delayed without auxiliary voltage with 2 c/o (SPDT) contacts

Electronic timer CT-ARS.11 OFF-delayed without auxiliary voltage with 1 c/o (SPDT) contact

Electronic timer CT-APS.21 OFF-delayed with 2 c/o (SPDT) contacts

Electronic timer CT-ERS.12 ON-delayed with 1 c/o (SPDT) contact

Electronic timer CT-ERD.12

Electronic timer CT-ARS.11

Electronic timer CT-AHD.22

Electronic timer CT-SDS.23 Star-delta change-over with 2 n/o contacts

Electronic timer CT-ERS.12 ON-delayed with 1 c/o contact Data sheet

Electronic timer CT-ERS.21

Power supply CP-C 24/5.0

Power supply CP-E 48/1.25 Primary switch mode power supply

Redundancy unit CP-D RU Accessory for CP range power supplies (e.g. switch mode power supplies CP-D range)

Power supply CP-E 24/0.75 Primary switch mode power supply

Power supply CP-D 12/2.1 Primary switch mode power supply

Power supply CP-E 24/10.0 Primary switch mode power supply

Thermistor motor protection relays CM-MSS.12 and CM-MSS.13

Electronic timer CT-ARS.21 OFF-delayed without auxiliary voltage with 2 c/o (SPDT) contacts

Thermistor motor protection relays CM-MSS.12 and CM-MSS.13

Three-phase monitoring relay

Thermistor motor protection relays CM-MSS.22 and CM-MSS.23

Thermistor motor protection relays CM-MSS.22 and CM-MSS.23

RTU500 series Data Sheet Power Supply CP-E 24/2.5

Thermistor motor protection relay CM-MSS.21

Thermistor motor protection relays CM-MSS.32 and CM-MSS.33

Thermistor motor protection relay CM-MSS.41

Thermistor motor protection relay CM-MSS.11

Thermistor motor protection relays CM-MSS.32 and CM-MSS.33

Buffer module CP-B 24/20.0, ultra-capacitor based Accessory for power supplies (e.g. switch mode power supplies CP range)

Thermistor motor protection relay CM-MSS.31

Thermistor motor protection relay CM-MSS.41

Contact protection relay

Power supply CP-C 24/5.0

Accessories for pluggable interface relays CR-P Sockets

Pluggable interface relays CR-P Pcb relays

Switching relay CT-IRS with 1, 2 or 3 c/o contacts Data sheet

Electronic timer CT-EAS ON-delayed and OFF-delayed with 1 c/o contact Data sheet

Boxed interface relays and optocouplers R600 Boxed slim relays, optocouplers and accessories

Electronic timer CT-AHS OFF-delayed with 2 c/o contacts Data sheet

Pluggable interface relays and optocouplers CR-P Pcb relays, optocouplers and accessories

Pluggable interface relays CR-M Miniature relays

Electronic timer CT-ERD ON-delayed with 1 c/o contact Data sheet

Accessories for pluggable interface relays CR-P, CR-M Pluggable function module

Electronic timer CT-VWD Impulse-ON with 1 c/o contact Data sheet

Accessories for pluggable interface relays CR-U Pluggable function modules

VEO. V2UF230V10 Art.Nr.: TECHNICAL DATA

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Electronic timer CT-AWS Impulse-OFF with 2 c/o contacts Data sheet

RTU511. Binary Output 23BO62. Characteristics. Application. Data Sheet Binary Output 23BO62. The binary output is made via relay contacts.

VEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA

Control elements. Fine adjustment. Status indication. 24 V DC typ. 0,25 W / 0,25 VA. 24 V DC typ. 0,03 W / 0,09 VA. 0,15 3 s. 0,5 10 h.

VEO. V2ZR V AC/DC Art.Nr.: V2ZR10P V AC/DC Art.Nr.: TECHNICAL DATA

02/11/2015

VEO. V2ZS V AC/DC Art.Nr.: V2ZS20P V AC/DC Art.Nr.: TECHNICAL DATA

em4 Accessories Digital expansions

RE22R2KMR Off-delay Timing Relay s 10min V AC/DC - 2C/O

RE22R2QGMR Star-Delta Timing Relay s 300h V AC/DC - 2C/O

RM22TG. Product data sheet Characteristics. three-phase control relay Vac, 2 C/O. Main. Complementary. Network number of phases

Phase loss monitor CM-PBE Phasemonitor for over and undervoltage CM-PVE Ordering details

ATS01N206RT soft starter for asynchronous motor - ATS01-6 A V

RE22R2QTMR Star-Delta Timing Relay s 300h V AC/DC - 2C/O

ABB i-bus KNX BCI/S Boiler/Chiller Interface

ATS01N232RT soft starter for asynchronous motor - ATS01-32 A V

RE22R2CMR Off-delay Timing Relay s 300h V AC/DC - 2C/O

ABB i-bus KNX HCC/S Heating/cooling circuit controller

AI561 Analog Input Module

DC561, digital input/output module,

RM35JA32MR Current control relay 0.15A 15A, 2 C/O

RM35TF. Main. Product or component type. Product specific application. Relay monitored parameters 250 V AC 5 A AC

RE22R2AMR On-delay Timing Relay s 300h V AC/DC - 2C/O

RM22LA32MR Level control relay RM22-L V AC/DC - 2 C/O

RM35UB3. Product data sheet Characteristics. voltage control relay RM35-U - range V AC. Main. Complementary

RE22R1QMQ star-delta timing relay - 230VAC/440VAC - 1 C/O

24 V DC typ. 0,65 W. Liquid level with conductive probes (type SK1, SK5) Resistance measurement E1-E0, E2-E0, E3-E0, E4-E0

RMCN22BD Analog Converter ma - for Zelio Analog

RM35TF V AC

RM17UB3. Product data sheet Characteristics. voltage control relay RM17-U - range V AC. Main. Complementary

DC562, digital input/output module,

RE22R2AMR On-delay Timing Relay s 300h V AC/DC - 2C/O

Output Voltage* (nom.)(adjustable)

TRIO-DIODE/12-24DC/2X10/1X20

Output Voltage* (nom.)(adjustable)

DI572 Digital Input Module

RM17TG. Main. Product or component type. Product specific application. Relay monitored parameters. Switching capacity in VA

DX561 Digital Input/Output Module

MINI-PS AC/10-15DC/8

Millenium 3. General Characteristics. General environment characteristics for CB, CD, XD, XR and XE product types

ATS01N103FT soft starter for asynchronous motor - ATS01-3 A V KW

DI561 Digital Input Module

RM17UAS. Product datasheet Characteristics. voltage control relay RM17-U - range V DC. Main. Complementary. Price* : 70.

ATSU01N209LT soft starter for asynchronous motor - ATSU01-9 A V KW

RM35LM33MW liquid level control relay RM35-L V AC/DC

AO523 Analog Input Module

TU531, TU532 Terminal Unit

Transcription:

2CDC 271 087 F0t04 Features Pluggable onto CP C range primary switch mode power supplies REMOTE OFF input to switch off the power supply unit remotely Monitoring of the input voltage of the power supply unit and messaging if below the limit value Monitoring of the output voltage of the power supply unit and messaging if below the limit value Output voltage monitoring is only in case of decoupled parallel operation possible a REMOTE OFF: terminals remote off b INPUT OK 11 12/14: terminals message supply voltage OK c OUTPUT OK 21 22/24: terminals message output voltage OK d REMOTE OFF: green LED remote off e INPUT OK: green LED supply voltage OK f OUTPUT OK: green LED output voltage OK Approvals D GOST valid until August 3, 2014 R EAC valid from August 4, 2014 Marks a b CE C Tick Order data Type Description Order code CP-C MM Messaging module The CP C MM indicates the correct function of the power supply unit via LEDs and energized output relay. 1SVR 427 081 R0000 Application The messaging module CP C MM monitors the input and output voltage of a CP C range primary switch mode power supply. Operating mode Indication of the correct function of the power supply with CP C MM The messaging module CP C MM can be plugged onto a CP C range primary switch mode power supply. It indicates the correct function of the power supply unit via LEDs and energized output relay. The power supply unit can be switched off by closing of a volt free (dry/floating) contact at the REMOTE OFF input. If the supply voltage at the input of the power supply falls below 82 V AC (70 V DC), the output relay INPUT OK (contacts 11 12/14) de energizes and the LED INPUT OK turns off. If the output voltage of the power supply falls below 19.8 V DC, the output relay OUTPUT OK (contacts 21 22/24) de energizes and the LED OUTPUT OK turns off. Output voltage monitoring is only possible in decoupled parallel operation. Installation Mounting The module is plugged and fixed as shown in the accompanying picture onto the front side of a CP C power supply. Doing so, the pre cut front foil of the power supply unit is penetrated by the latching hooks and the plug contacts. The module must not be plugged in when the power is on. 2CDC 272 073 F0b04 1

Installation Demounting The module is removed as shown in the accompanying picture. The module must not be removed when the power is on. 2CDC 272 074 Fb004 Electrical connection REMOTE OFF If the terminals are short circuited (R 1 kω) e.g. via a n/o contact, the power supply unit is switched off remotely. If the resistance R between the terminals is 10 kω, the power supply unit is switched on. Attention! Terminal potential = input voltage INPUT OK Volt free (dry/floating) change over contact closed circuit principle 11 14 closed and 11 12 open, if the input voltage of the power supply unit is > 85 V AC / 90 V DC. 11 12 closed and 11 14 open, if the input voltage of the power supply unit is < 82 V AC / 70 V DC. 11 14 also closed, if REMOTE OFF. OUTPUT OK Volt free (dry/floating) change over contact closed circuit principle 21 24 closed and 21 22 open, if the output voltage of the power supply unit is > 20.2 V DC. 21 22 closed and 21 24 open, if the output voltage of the power supply unit is < 19.8 V DC. Connection diagram(s) REMOTE OFF INPUT OK 11 12 14 OUTPUT OK 21 12 11 14 22 21 24 2CDC 272 049 F0b07 22 24 INPUT OK 11 12/14 OUTPUT OK 21 22/24 REMOTE OFF Message supply voltage OK Message output voltage OK Remote off of power supply Wiring instructions 2CDC 272 020 F0b05 2

Technical data Data at T a = 25 C, U in = 230 V AC and rated values, unless otherwise indicated Input circuits - Supply circuits Rated input voltage U in Input voltage range Typical power consumption 110-240 V AC / 100-350 V DC 70 264 V AC / 80 350 V DC 2.5 VA / 1.5 W Input circuits - Control circuit Kind of triggering volt free triggering Control input, control function REMOTE OFF Remote off Threshold value for switching off R 1 kω Threshold value for switching on R 10 kω Input current typ. 1 ma (200 ma for 200 µs) Maximum cable length to the control input 25 m - 100 pf/m Measuring circuit - Input powered by the input circuit of the power supply unit Monitoring function undervoltage monitoring Threshold value(s) 85 V AC / 90 V DC Hysteresis related to the threshold value AC: typ. 8 % / DC: 30 % Accuracy / Tolerance 5 % (at AC and DC) Maximum measuring cycle typ. < 50 ms Measuring circuit - Output powered by the output circuit of the power supply unit Monitoring function undervoltage monitoring Threshold value(s) 20 V DC Hysteresis related to the threshold value typ. 5 % Accuracy / Tolerance ±1 % Maximum measuring cycle typ. < 10 ms Indication of operational states Remote off REMOTE OFF: green LED V: REMOTE OFF input 1kOhm Supply voltage INPUT OK: green LED V: supply voltage OK Output voltage OUTPUT OK: green LED V: output voltage OK Output circuits Kind of output 11 12/14 relay, 1 c/o contact 21 22/24 relay, 1 c/o contact Contact material AgNi Rated output voltage (IEC/EN 60947 1, VDE 0110) 250 V Operational principle closed circuit principle Minimum switching voltage / Minimum switching current 24 V / 10 ma Maximum switching voltage / Maximum switching current 250 V / 1 A Rated operational current I e (IEC/EN 60947 1) AC12 (resistive) at 230 V 1 A AC15 (inductive) at 230 V 1 A DC12 (resistive) at 24 V DC13 (inductive) at 24 V 1 A 1 A 3

Output circuits Mechanical lifetime Electrical Lifetime Maximum fuse rating in order to achieve short-circuit protection n/o contact n/c contact 30 x 10 6 switching cycles 0.1 x 10 6 switching cycles 2 A, gl 2 A, gl General data Duty time 100 % Dimensions (W x H x D) when mounted Material of enclosure Weight Mounting position Mounting 56.5 x 54 x 24 mm (2.22 x 2.13 x 0.94 inches) plastic 0.065 kg (0.14 lb) plugged onto power supply unit snap on mounting without any tool Degree of protection enclosure / terminals IP20 / IP20 Class of protection (EN 61140) II Electrical connection Wire size Stripping length Tightening torque fine strand with wire end ferrule fine strand without wire end ferrule 0.2 2.5 mm 2 (24 14 AWG) 0.2 2.5 mm 2 (24 14 AWG) rigid 0.2 4 mm 2 (24 12 AWG) 7.5 mm (0.3 inches) 0.4 0.6 Nm Environmental data 1SVR 427 081 R0000 Ambient temperature range operation 25...+70 C storage 40...+85 C Damp heat (IEC/EN 60068 2 3) Climatic category (EN 60721) Vibration (IEC/EN 60068 2 6) Shock (IEC/EN 60068 2 27) 93 % at +40 C, no condensation 3k3 Isolation data Rated isolation voltage U i (IEC/EN 60947 1, EN 50178, VDE 0160) Rated impulse withstand voltage U imp (type test) (IEC 664, VDE 0110) Power frequency withstand voltage test (Test voltage, routine test) 250 V between all isolated circuits 4 kv; 1.2/50 µs all circuits 2.5 kv AC Protective separation all circuits yes Pollution degree (IEC/EN 60950) 2 Overvoltage category (IEC/EN 60950) II Standards / Directives Product standard IEC/EN 61204 EMC Directive 2004/108/EC Low Voltage Directive 2006/95/EC Electrical safety EN 50178, EN 60950, UL 60950, UL 508 4

Electromagnetic compatibility Interference immunity to IEC/EN 61000 6 2 electrostatic discharge IEC/EN 61000 4 2 Level 3 and 4 (6 kv / 8 kv) radiated, radio-frequency, electromagnetic field IEC/EN 61000 4 3 Level 3 (10 V/m) electrical fast transient / burst IEC/EN 61000 4 4 Level 4 and 2 (4 kv power input / 1 kv control input) surge IEC/EN 61000 4 5 Level 3 and 2 (4 kv symmetrical power input / 1 kv control input) conducted disturbances, induced by radiofrequency fields IEC/EN 61000 4 6 Level 3 (10 V) Interference emission IEC/EN 61000 6 3 high-frequency radiated IEC/CISPR 22, EN 55022 Class B high-frequency conducted IEC/CISPR 22, EN 55022 Class B 5

Dimensions in mm 54 [2.13 ] 56,5 [2.22 ] 24 [0.94 ] 2CDC 272 016 F0b07 CP-C MM Further Documentation Document title Document type Document number Electronic Products and Relays Technical catalogue 2CDC 110 004 C02xx Power Supply Units Application manual 2CDC 114 048 M020x You can find the documentation on the internet at www.abb.com/lowvoltage R Control Products R Power Supplies CAD system files You can find the CAD files for CAD systems at http://abb-control-products.partcommunity.com/partcommunity/portal/abb-control-products -> Low Voltage Products & Systems -> Control Products -> Power Supplies 6

Contact us STOTZ-KONTAKT GmbH P. O. Box 10 16 80 69006 Heidelberg, Germany Phone: +49 (0) 6221 7 01-0 Fax: +49 (0) 6221 7 01-13 25 E-mail: info.desto@de.abb.com You can find the address of your local sales organisation on the home page http://www.abb.com/contacts -> Low Voltage Products and Systems Document number 2CDC 114 014 D0202 (09/14) Note: We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. AG does not accept any responsibility whatsoever for potential errors or possible lack of information in this document. We reserve all rights in this document and in the subject matter and illustrations contained therein. Any reproduction, disclosure to third parties or utilization of its contents in whole or in parts is forbidden without prior written consent of AG. Copyright 2014 All rights reserved