CHP GAS MONITOR GDR 1404

Similar documents
CHP GAS MONITOR GDR 1404

DATA-COMMUNICATION-MODULE DATACONT DC 6000

General information. Display. Supply voltage

General information. Display. Supply voltage

General information. Display. Supply voltage

General information Engineering with Programming package. Display with display. Supply voltage 24 V DC Yes. Input current

General information. Display. Supply voltage. Input current

General information. Display. Supply voltage. Input current

General information. Display. Supply voltage. Input current

General information. Display. Supply voltage. Input current

General information. Display. Supply voltage. Input current

General information. Display. Supply voltage. Input current

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current. Encoder supply. Output current

Display. Supply voltage. Input current. Encoder supply. Output current. Power losses. Memory

General information. Display. Supply voltage. Input current

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current. Encoder supply. Output current

Display. Supply voltage. Input current. Encoder supply. Output current. Power losses. Memory

General information. Display. Supply voltage. Input current. Encoder supply. Output current. Power loss. Memory

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information Engineering with Programming package. Display with display. Supply voltage 24 V DC Yes

General information. Supply voltage. Input current. Encoder supply. Power loss. Memory

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current. Encoder supply. Power losses

General information Engineering with Programming package. Display with display. Supply voltage 24 V DC Yes. Input current

MIC-2 Multi-instrument DATA SHEET

General information Engineering with Programming package. Display with display

XPSMF35. Product data sheet Characteristics. Preventa safety PLC compact - Profibus DP protocol. Main. Complementary. Safety module name

MIC-2 MKII & MIC-2 MKII DIN, Multi-instrument DATA SHEET

MIC-2 MKII, Multi-instrument DATA SHEET

IDS 500 mobile Intelligent mobile chart recorder

MID approval no. DE-08-MI004-PTB004 Date of release

Chart recorder. DS 500 mobile Intelligent mobile chart recorder

INTECONT PLUS for Measuring Systems

DATASHEET ULTRASONIC COMPACT ENERGY METER MODEL 773

Insertion Flowmeter for compressed air and gases DN50 - DN700 (2-28 )

MPI-DN, MPI-D MULTICHANNEL ELECTRONIC RECORDER for HART or RS-485/ MODBUS RTU SENSORS

Flow. Order number VA 550. Order no. VA 570. Further accessories A_...M_

Product type designation. Control elements. Installation type/mounting

6ES7212-1BD30-0XB0. permissible range, lower limit (DC) permissible range, upper limit (DC)

Indicating Digital Transmitter for Differential Pressure and Flow. Media 6 with LCD Media 6 with LED

Networks TN, TT, IT networks 3 and 4-phase networks Up to 4 single-phase networks

Vane wheel probe BFA25 for flow measurement of gases and liquids with integrated, configurable transducer UFA in Ex-d housing

CPU 1214C. Overview. Design. The compact CPU 1214C has:

Data sheet CC 03, Commander Compact (603-1CC21)

XPSMF40. Main. Safety module name. Monitoring safety detection discrete input Monitoring safety dialogue discrete output

EW773 Series Ultrasonic Hydronic Meters FOR HEATING AND COOLING APPLICATIONS

Extruder Controls ExtruVision S

INTECONT Tersus Mass flow rate measurement

IDS 400 mobile Affordable, mobile chart recorder. Flow Pressure / Vacuum Temperature Moisture / Dew point Optional third-party sensors

MID PRELIMINARY DATA SHEET. RI-D Series. Single Phase Multifunction Energy Meter (MID Certified) MID

Energy meters Single phase electrical energy meters WM1-6 / WM1M6

Flow VA 500/

Hyamaster r SPS. Intelligent single and multiple pump control system with continuous speed control by frequency inverter, with PLC SIMATIC r S7

Chart recorder. DS 400 mobile Affordable, mobile chart recorder. Flow Pressure / Vacuum Temperature Moisture / Dew point Optional third-party sensors

UMG 20CM. 20 Channel Branch Circuit Monitoring Device with RCM

Supply voltage. Input current. Encoder supply. Memory SIMATIC S7-200, CPU 221 COMPACT UNIT, DC POWER SUPPLY 6 DI DC/4 DO DC, 4 KB CODE/2 KB DATA,

Structure and Function

DS 500 Intelligent chart recorder for compressed air and gases

Catalogue for measuring professionals

RHE16. Compact Multifunction Coriolis Flow Meter Transmitter. Features. Applications. Benefits

Data sheet CPU 115 (115-6BL02)

Assembly MAU. MUX 4 Channels 8 Channels Zone 1

NF760 Batch Controller

OHIO SEMITRONICS, INC. AC MULTIFUNCTION PROGRAMMABLE TRANSDUCERS & -1000L

Hydrostatic filling level sensor HFB C4 / R / MD

Data sheet VIPA CPU 115DP (115-6BL22)

Supply voltage. Input current. Encoder supply. Memory

Measuring transducers MI4x0 series Programmable transducers for RTD sensors MI450

RHE16. Compact Multifunction Coriolis Flow Meter Transmitter. Features. Applications. Benefits

The safety control of the next generation

EE360. High-End Moisture in Oil Transmitter. Typical applications. Features EE360 EE360. (+34)

Thermal Mass Flowmeter Sensyflow FMT200-D

XPSMCMCO0000EM Modbus TCPIP diagnostic expansion module with screw term

Catalogue for measuring professionals

with Backlight Graphic LCD Screen

NF770 Temperature Compensation Liquid Flow Computer

SYSTEM COMPONENTS SYSTEM COMPONENTS MODULES

Energy Management Modular DC Energy analyzer Type VMU-E and VMU-X

TWDLCAE40DRF compact PLC base Twido V AC supply - 24 I 24 V DC - 16 O

Condition Monitoring Unit CMU 1000

Fieldgate SFG500. Technical Information. Intelligent Ethernet/PROFIBUS gateway

Flow Measurement SITRANS F US Inline

Flow Measurement SITRANS F US Inline

PAS 300, PROFIBUS Slave Interface Module

TWDLCAE40DRF. Main. Range of product

Multifunction Transducer MT440

PI 500 Hand-held instrument for industry

ATV630U15N4 variable speed drive ATV kW/2HP V - IP21/UL type 1

APU 200 Automatic DATA SHEET Gen-set Controller DATA SHEET

Flow Measurement SITRANS F M. Transmitter MAG 6000 I/6000 I Ex de. 3/46 Siemens FI

Product type designation. General information. Supply voltage. Input current

U niversal Measuring Device UMG 96 S. Little Fieldbus Giant. Modbus / Profibus. Harmonics. Memory. Analogue outputs. Digital I/O

DATA SHEET. Advanced Power Meter, APM 380 & APM 305

TM251MESC controller M251 Ethernet CAN

UMG 20CM. UMG 20CM 20 Channel Branch Circuit Monitoring Device with RCM. Harmonics via analysis channel RCM. Alarm management.

Level measurement. Applications. Special features. Description

Transcription:

CHP GAS MONITOR GDR 1404 with Ethernet/IP, Bluetooth, PROFIBUS-DP, Modbus-RTU, Modbus-TCP The series GDR 1404 is characterized by direct calculation of the gas consumption in Nm³. According to the configuration and the measuring method, the device collects data from up to 4 sensors (flow rate, pressure, temperature and hydrostatic pressure) which are necessary for the calculation in Nm³. If one of these values is not measured by a sensor, the Nm³ can be calculated with a adjustable fixed value. In stage of expansion the device is also able to process the electrical capacity (CHP) and the infeed loss. On basis of these data the electrical efficiency factor of the CHP is calculated. The programming of the device is carried out by PC using the software "E3DM" via Ethernet- or USB interface. Calculating the efficiency factor of the CHP Integrated recording function to register measurement data (ring buffer 2 GB) Optional measurement of partial gas quantity to operate over SPS Integration into IT-networks using Ethernet TCP/IP to remote data transmission and device control Up to 12 devices curable through internal CANBUS At network loss persistent data management of the total counter reading for a period of 5 years Calculation according to DIN 1343, DIN 6358, DIN ISO 2533, DIN 102/ISO 1-1975 Optional input for measured value clearing Optional connection of a gas analysis (e.g. Awite, Bieler & Lang, Chemec, Esders, ExTox, Fresenius, Pronova, Union Instruments) Optional data input for up to 4 measured values Datasheet DS 307 E 1

Application example CHP Gas Monitor with gas engine Gas tank Gas analysis ( CH4, CO2, O2, H2S ) via RS 232 Gas cooling Gas compressor GD 300 P feeder line CHP plant Flare EVU meter Transformer station P Hydro Ethernet CAN-Bus Gas temperature Gas flow Gas pressure Hydrostatic pressure CHP plant kw/h EVU meter RS 232 0(4)...20mA Impulse 0(4)...20mA 0(4)...20mA 0(4)...20mA Impulse USB SPS 0(4)...20mA 0(4)...20mA Nm³/h Nm³ Digital Start / Stop Digital Release Relay NO Nm³ Relay NO Alarm Electrical maesuring lines Electrical control lines Data lines Gas lines I0712062d 2 Datasheet DS 307 E

Technical data The devices of the series GDR 1404 are designed as a modular system. The system enables the configuration of inputs, outputs, interfaces and software options which are required according to the individual requirements of the installation and application. This section gives an overview of all technical information of the series. INPUT INPUT 1 INPUT 2 INPUT 3 INPUT 4 INPUT 5 INPUT 6 INPUT 7 INPUT 8 DIGITAL INPUT S1 DIGITAL INPUT S2 0 (4) - 20 ma, 2-wire (temperature) = -100-2000 C (14 bit), input resistance < 100 ohm using 20 ma 0 (4) - 20 ma (flow rate) = 0-20.000 m³/h (14 bit), input resistance < 100 ohm using 20 ma or pulse input for gas flow meter GD 300 / GD 500 (flow rate), 10-1 khz at 5% duty cycle, pulse length > 500 μs 0 (4) - 20 ma, 2-/3-wire (pressure) = 0-30 bar (14 bit), input resistance < 100 ohm 0 (4) - 20 ma, 2-/3-wire (hydrostatic pressure) = 0-30 bar (14 bit), input resistance < 100 ohm using 20 ma 0(4)-20mA, calculation of efficiency factor (ETA) Pulse, calculation of feeding loss (EVU), 10-1 khz at 5% duty cycle, pulse length > 500 μs 0 (4) - 20 ma, 2-/3-wire, input resistance < 100 ohm 0 (4) - 20 ma, 2-/3-wire, input resistance < 100 ohm Digital gate-input, partial quantity (start/stop) Digital gate-input, release OUTPUT OUTPUT 1 OUTPUT 2 0(4) - 20 ma = 0 - (x) Nm³/h flow rate (freely programmable), load 500 ohm 0(4) - 20 ma = 0 - (x) Nm³ partial quantity (freely programmable), load 500 ohm RELAY K1: COUNTING OUTPUT Relay 1 or 10 or 100 Nm³ per pulse ((freely programmable) (counting output (quantity), NO switch) K2: DEVICE ERROR If an instrument failure occurs the relay is released. Superior systems are able to detect a failure in the measuring system through this signal (NO switch). Load 250 V, AC, 1,5A inductive ELECTRIC VALUES ACCURACY ± 0,05 % EW ± 1 Digit at 23 C POWER SUPPLY 24 V, DC ± 3 V Datasheet DS 307 E 3

ENVIRONMENTAL INFLUENCES AMBIENT TEMPERATURE STORAGE TEMPERATURE TEST VOLTAGE -10 to +55 C -20 to +85 C 3 kv HUMIDITY CLASS E-DIN 40040 ELECTROMAGNETIC COMPATIBILITY acc. to EN 61000 DISPLAY, HOUSING, WEIGHT DISPLAY STANDARD HOUSING RAIL MOUNTING PROTECTIVE HOUSING (OPTION M104) WALL MOUNTING PROTECTIVE HOUSING WITH EX-ZONE (OPTION M105) WALL MOUNTING 6-digit LCD-display for flow rate in Nm³/h (resolution 0,1 Nm³) 8-digit LCD-display in Nm³ (resolution 0,1 Nm³) Display height 8 mmm Dimensions: 100 mm (W) x 100 mm (H) x 107 (D) mm Protection class: IP 20 Net weight: approx. 480 g Dimensions: 343 mm (W) x 330 mm (H) x 210 mm (D) with tab and high-strength cable gland Protection class: IP 65 Dimensions: 385,5 mm (W) x 487 mm (H) x 210 mm (D) with tab and high-strength cable gland Protection class: IP 65 SWITCHBOARD HOUSING (OPTION M112) SWITCHBOARD DOOR MOUNTING PORTABLE HOUSING (OPTION M122) SWITCHBOARD HOUSING (OPTION M113) SWITCHBOARD DOOR MOUNTING PORTABLE HOUSING (OPTION M123) Switchboard disruption: 151 ±1 mm x 332,5 ±1 mm Front frame: 169,7 mm (W) x 351 mm (H) Front frame height: 51 mm Installation depth: 140 mm Max. wall thickness: 23 mm Protection class: IP 30 Dimensions: 147 mm (W) x 364 mm (H) x 261 mm (D) Protection class: IP 30 Switchboard disruption: 151 ±1 mm x 332,5 ±1 mm Front frame: 169,7 mm (W) x 351 mm (H) Front frame height: 51 mm Installation depth: 140 mm Max. wall thickness: 23 mm Protection class: IP 65 Dimensions: 147 mm (W) x 364 mm (H) x 261 mm (D) Protection class: IP 65 4 Datasheet DS 307 E

SOFTWARE & RECORDER GAS ANALYSIS (OPTIONAL) E3DM RECORDER (OPTIONAL) Data transmission of connected gas analysis (Awite, Bieler & Lang (GMC Biogas 08), Chemec (BC20, BC30), Esders (Goliath Biogas), ExTox (ET-4D2, ET-8D), Fresenius Umwelttechnik (BioBasic), Pronova (SSM6000), Union Instruments (INCA, Kaloriemeter) Esters Energy Efficiency and Device Manager Energy Management- and Configuration Software for Microsoft Windows (32-Bit) Ring buffer 2 GB Data recorder for logging of measurement values over a period of several years. INTERFACES RS 232 USB CANBUS (OPTIONAL) PROFIBUS DP (OPTIONAL) MODBUS RTU (OPTIONAL) MODBUS IP (OPTIONAL) ETHERNET (OPTIONAL) 9-pin connection for gas analysis Mini USB-connection (5-pin, USB 2.0) for configuration and data transfer through PC Internal communication of up to 12 curable devices Data transmision via Profibus-DP protocol Data transmision via MODBUS-RTU protocol Data transmision via MODBUS-TCP protocol Integration into the IT-network for configuration and data transfer through PC Software E3DM - Esters Energy Efficiency and Device Manager Graphic visualization of the measured values continuously recorded in the ring buffer. In the illustration the following measured values are displayed: - Efficiency factor in % (Wirkungsgrad in %) - Flow (m³) (Durchfluss m³) - Gas quality (CH 4 ) (Gasqualität (CH 4 ) - Electrical capacity in kw (Elektrische Leistung in kw) - Temperature in C (Temperatur in C) Datasheet DS 307 E 5

Tabular visualization of the measured values continuously stored in the ring buffer. The reported data can be assorted with multi-level column sort. In the illustration the data is arranged according to signal and height of the measured value. Electr. efficiency factor [I] Flow In the master display the actual measured values are mapped. The amount of the displayed values and the graphical illustration can be adjusted individually. Pressure Feeding loss Temperature Electr. capacity Supplied capacity 6 Datasheet DS 307 E

Order information The ordering code consists of the device type GDR 1404 and an 8-digit code, which itself is devided into 2 sections with four points. GDR 1404-xxxx-00yy In the following tables the first four points are defined according to the desired equipment. It is to be noted, that the fifth and sixth positions are already defined by digit sequences. The last two digits define the content of functions (such as ring buffer, interfaces for industrial bus systems). Example: GDR 1404-01FD-001C M104 The CHP gas monitor has a pulse input for flow measurement, two inputs for pressure and temperature measurement, an input for hydrostatic pressure, a pulse input for the utility meter and the function for determining the efficiency. The unit is also equipped with the optional functions Profibus-DP interface, Ethernet TPC/IP interface, a 2 GB ring buffer and is built into a field housing for wall mounting. Devices with pulse-input for flow measurement (e.g. GD 300, GD 500 incl. Ex ia isolating amplifier) GDR 1404-XXXX-00YY INPUT ECONOMY STANDARD ADD. MEASURING CHANNELS 0241 0249 0041 0049 005D 0069 0849 084D 1849 184D 0869 086D 1869 186D 1: 0 (4)-20mA, 2/3-wire temperature 2: Pulses, flow rate 3: 0 (4)-20mA, 2/3-wire pressure 4: 0 (4)-20mA, 2/3-wire hydrostatic. pressure 5: 0 (4) - 20 ma, for add. sensor 6: 0 (4) - 20 ma, for add. sensor 7: 0 (4) - 20 ma, for add. sensor 8: 0 (4) - 20 ma, for add. sensor DIGITALE INPUT S1: partial quantity (start/stop) S2: release OUTPUT 1: 0 (4) - 20 ma = 0 - (x) Nm³/h flow rate 2: 0 (4) - 20 ma = 0 - (x) Nm³ partial quantity RELAY K1 (NO switch) rate Nm³ K2 (NO switch) alarm relay INTERNAL SOFTWARE Integration of gas analysis Power supply: 24 V, DC USB & RS 232 Software E3DM Datasheet DS 307 E 7

Devices with ma-input for flow measurement (e.g. Ecoflow2, third-party products) ECONOMY STANDARD ADD. MEASURING CHANNELS GDR 1404-XXXX-00YY 0201 0209 0001 0009 001D 0029 0809 1809 0829 1829 INPUT 1: 0 (4)-20mA, 2/3-wire temperature 2: 0 (4) - 20 ma, flow rate 3: 0 (4)-20mA, 2/3-wire pressure 4: 0 (4)-20mA, 2/3-wire hydrostatic. pressure 5: 0 (4) - 20 ma, for add. sensor 6: 0 (4) - 20 ma, for add. sensor 7: 0 (4) - 20 ma, for add. sensor 8: 0 (4) - 20 ma, for add. sensor DIGITAL INPUT S1: partial quantity (start/stop) S2: release OUTPUT 1: 0 (4) - 20 ma = 0 - (x) Nm³/h flow rate 2: 0 (4) - 20 ma = 0 - (x) Nm³ partial quantity RELAY K1 (NO switch) rate Nm³ K2 (NO switch) alarm relay INTERNAL SOFTWARE Integration of gas analysis Power supply: 24 V, DC USB & RS 232 Software E3DM 8 Datasheet DS 307 E

Devices with integrated efficiency calculation Devices with pulse-input for flow measurement (e.g. GD 300, GD 500 incl. Ex ia isolating amplifier) GDR 1404-XXXX-00YY 00E1 00E9 00FD 01E1 01E9 01FD 50C1 50C9 50DD 51C1 51C9 51DD INPUT 1: 0 (4)-20mA, 2/3-wire temperature 2: Pulses, flow rate 3: 0 (4)-20mA, 2/3-wire pressure 4: 0 (4)-20mA, 2/3-wire hydrostatic. pressure 5: 0 (4)-20mA, calculation of efficiency (ETA) 6: Pulses, calculation of feeding loss (EVU) 7: 0 (4) - 20 ma, CH 4 -value (gas analysis) 8: 0 (4) - 20 ma, for add. sensor DIGITALE INPUT S1: partial quantity (start/stop) S2: release OUTPUT 1: 0 (4) - 20 ma = 0 - (x) Nm³/h flow rate 2: 0 (4) - 20 ma = 0 - (x) Nm³ partial quantity RELAY K1 (NO switch) rate Nm³ K2 (NO switch) alarm relay INTERNAL SOFTWARE Integration of gas analysis Calculation of efficiency Netz: 24 V, DC USB & RS 232 Software E3DM Datasheet DS 307 E 9

Devices with ma-input for flow measurement (e.g. Ecoflow2, third-party products) GDR 1404-XXXX-00YY 00A1 00A9 00BD 01A1 01A9 01BD 5081 5089 509D 5181 5189 519D INPUT 1: 0 (4)-20mA, 2/3-wire temperature 2: 0 (4) - 20 ma, flow rate 3: 0 (4)-20mA, 2/3-wire pressure 4: 0 (4)-20mA, 2/3-wire hydrostatic. pressure 5: 0 (4)-20mA, calculation of efficiency (ETA) 6: Pulses, calculation of feeding loss (EVU) 7: 0 (4) - 20 ma, CH 4 -value (gas analysis) 8: 0 (4) - 20 ma, for add. sensor DIGITALE INPUT S1: partial quantity (start/stop) S2: release OUTPUT 1: 0 (4) - 20 ma = 0 - (x) Nm³/h flow rate 2: 0 (4) - 20 ma = 0 - (x) Nm³ partial quantity RELAY K1 (NO switch) rate Nm³ K2 (NO switch) alarm relay INTERNAL SOFTWARE Integration of gas analysis Calculation of efficiency Power supply: 24 V, DC USB & RS 232 Software E3DM 10 Datasheet DS 307 E

Optional device funtions and housings GDR 1404-XXXX-00 0 no selection 1 Interface PROFIBUS-DP 2 Interface Modbus-RTU 4 Interface Modbus-TCP 0 no selection 1 Interface CAN-Bus 4 Interface Ethernet TCP/IP 5 Interface CAN-Bus, Interface Ethernet TCP/IP 8 Ring buffer 2 GB (data recorder) 9 Ring buffer 2 GB (data recorder), Interface CAN-Bus C Ring buffer 2 GB (data recorder), Interface Ethernet TCP/IP D Ring buffer 2 GB (data recorder), Interface CAN-Bus, Interface Ethernet TCP/IP HOUSING M104 Field housing for wall mounting, protection class IP 65 M105 Field housing with Ex-Zone for wall mounting, protection class IP 65 M112 Switchboard door housing, protection class IP 30 M122 Portable housing, protection class IP 30 M113 Switchboard door housing, protection class IP 65 M123 Portable housing, protection class IP 65 Datasheet DS 307 E 11

Fluidistor Gas Flowmeter GD 300 The Fluidistor Gas Flowmeter (stainless steel 1.4571) measures all technical and medical gases with a nominal width of DN25 to DN400 and a measurement range of 0,2... 20... 16.000 m 3 /h. For further information see datasheet DS 312 E. Compact-Fluidistor Gas Flowmeter GD 500 The Compact-Fluidistor Gas Flowmeter (stainless steel 1.4571) measures all technical and medical gases with a measurement range of 0,21-16,8 m 3 /h (process connection R 1/2, PN16). For further information see datasheet DS 313 E. similar image Your local contact: 12 Datasheet DS 307 E