ESA SERIES ELECTRONIC BALANCE

Similar documents
1.0 Description. 2.0 Unpacking. 3.0 Installation

Model Bulk Sampling Scale. User s Manual

YJ Carat and Gold Scales

Installation Guide. Wyse Rx0L Thin Client Flash and RAM Upgrade Option Kit. Issue: PN: L Rev. A

User Guide CPSMP VAC Power Supply Module: PointSystem CPSMC Accessory CPSMC Accessory. Contents.

Model Bulk Sampling Scale. Setup, Configuration and Calibration Manual

Model PS3000 with SBI-100 Indicator

Digital Bench Scale. Revision 1.2 September 14, 2000 Contents subject to change without notice.

Digital Bench Scale. Revision 1.2 August 24, Contents subject to change without notice.

Digital Bench Scale. Revision 8.93 August 12, 1993

User s Guide CPSMC0200-2x0 Dual-Slot PointSystem Chassis

ADL-100 Operator s Manual

GraviTek Titration Scale Instruction Manual

1. INTRODUCTION This manual contains installation, operation and maintenance instructions. Please read the manual completely before using the balance.

CANADIAN D.O.C. WARNING

Userʼs Guide. 1200g High Precision Scale. 1200g High Precision Scale. Legal for Trade. Includes RS-232 interface port. UG Version 1.

RS-232/RS-422 Optical Isolator

Operating Instructions

Model 7821 Bench Scale. User s Manual

Monarch 9414 Printer. TC9414EM 7/99 Rev. AB 1999 Monarch Marking Systems, Inc. All rights reserved.

Adam Equipment LBK SERIES. (P.N. 9596, Revision D, July 2014)

PC Media Converter, Switching (TP-TX/FX)

MODEL PS 150 PS 400 DIGITAL RECEIVING SCALE Operation Manual

BEETLE /Fusion Compact. Installation Guide

Allworx Tx 92/24 Telephone Expander Installation Guide

Operating Instructions

Quick Start Installation Guide

Operator s Handbook. Monarch FreshMarx 9417 Food Freshness System. TC9417OH Rev. AE 1/ Avery Dennison Corp. All rights reserved.

2DScan TM Barcode Scanner

Connectivity Peripherals User s Guide. Point 510 Point 1600

About the LAN Extenders Warranty Federal Communication Commission Radio Frequency Interference Statement Getting to Know the LAN Extenders The LEDs

FIBER OPTIC A/B/C/D SWITCH (NON-LATCHING)

FIBER OPTIC A/B/C/D SWITCH (LATCHING)

Monarch 939i Intelligent Keyboard

Installation Guide for. PCC Premier Precision Camera Controller. Document Rev. C

Infosystem Remote Touchscreen Installation Instructions

Mini Wireless Barcode Reader Quick Guide

Start Here. Features. Model DS108 Dual Speed Hub Installation Giude

NSD/M1 Installation Instructions

Rack Input Module Installation Instructions

QS7800A Network Interface ControlBus Module for 7800 SERIES Relay Modules

User s Guide CPSMM Dual-Slot Master Management Module CPSMM Single-Slot Expansion Management Module

T1 Fold (2KM) SEPTEMBER 1995 MT612A-ST MT612AE-ST. T1 - Fold CUSTOMER SUPPORT INFORMATION

NCH-1000 (Multiple Breaker Types) Installation Instructions

DRD-4 DRD-4 JULY 1992 FX140A CUSTOMER SUPPORT INFORMATION

CANADIAN D.O.C. WARNING

INSTALLATION INSTRUCTIONS

Copyright Black Box Corporation. All rights reserved Park Drive Lawrence, PA Fax

Cat. No KT/B. Installation Data

User Manual. Monarch Printers AAFES Kit Paxar Americas, Inc. a subsidiary of Avery Dennison Corp. All rights reserved.

IE-MediaChassis/1. Operation Manual

PLATINUM PRO1001DXP DIGITAL COUNTERTOP / PORTABLE BALANCE

CHS 7Ci. Bluetooth Cordless Barcode Scanner. Quick Start Guide

MODEL SPS-10. User Manual DIGITAL POSTAL SCALE

Installing the ipower 70 Room Camera

Explorer Pro Instruction Manual

Digital Weight Indicator Setup / Operation Manual

USB USB Data Transfer

3174/3274 I-Mux FEBRUARY 1993 MX330A-C MX330A-D CUSTOMER SUPPORT INFORMATION

CONTENTS. PRECAUTIONS Introduction Installation... 7

VS-K20 Compact Camera Controller. User Manual English

VC-B10U HD Camera (USB 3.0 Camera) Installation Manual - English

Ohaus Hand-Held Scale Model HH 120D -OPERATING MANUAL-

QS7800B Network Interface ControlBus Module for Multi-Dropping 7800 SERIES Relay Modules

adynamo Technical Reference Manual PART NUMBER October 2014

Verify Package Contents

QC-3265 Checkweigher User s Manual

PC 150. Digital Bench Scale. Operation Manual

7800 SERIES S7810B Multi-Drop Switch Module

Visit for discount prices on Acculab Scales SVI SERIES PROFESSIONAL PRECISION INDUSTRIAL SCALE SVI-10A SVI-20B SVI-50C SVI-100E SVI-200F

Item No.: 4SK108. User Manual. Thank you for choosing The Original Dash Cam. This manual offers detailed information on how to operate TODC (The

Copyright Western Scale Co. Limited. All rights reserved.

Mobile UHF Reader. Quick Guide. For full user s manual, please contact your local distributor. Mobile UHF Reader Quick Guide (Rev2) P/N:

10/100 Autosensing PC Media Converter

Precision Balance W3200 Series Operating Manual

INTRODUCTION INSTALLATION

RS-232 HS4 JANUARY 1997 IC131C CUSTOMER SUPPORT INFORMATION

DWP-PC SERIES PRICE COMPUTING SCALE User s Guide

AL-Series INSTRUCTION MANUAL AL-311 AL-201S. American Weigh Scales, Inc. Analytical Balances American Weigh Scales, Inc. pcs% kgct.

MWP SERIES. High Precision

SELECTING THE LOCATION PREPARATION FOR USE. Pan Calibration Mass (only for SJX/E models with 64g capacity) Scoop (only for models with 64g capacity)

BEETLE MSR Module. Swipe Card Reader. for BA7x. User Guide

What s In The Box. Key Descriptions. - ON/OFF - Turns the scale MOXIE ON or OFF. PCS - Enter counting mode. Hold to set sample quantity for average

EHC-WF. User/Technical Manual. Contents subject to change without notice

Operating instructions METTLER TOLEDO BD balances

American Weigh Scales, Inc. AMW-BENCH. D i g i t a l T a b l e t o p S c a l e. User Manual

EDGE. Digital Kitchen Scale. 11lb x 0.1oz 5000g x 1g

Sartorius Research. R 160 P Electronic Semi-Microbalance

EZ Switch EZ Connect N SMCFS1601/SMCFS2401

Industrial SBU Product User s Manual

Operator s Manual For Use With the Signature III CD Color Printer or Inscripta Thermal CD Printer

Installer/User Guide

OHAUS SCOUT BALANCE SCALE

WI-130 WDAC User s Manual

3600B Series Bench Scale

Husky MP2500 User Leaflet

Kilotech. KRS SWP Series. Counter-top weighing scale. NTEP (USA) and Measurement Canada approved.

PLATINUM PRO1001V DIGITAL COUNTERTOP / PORTABLE BALANCE

CONTENTS INTRODUCTION 1 INSTALLATION 1 KEYS 3 MAXIMUM DISPLAY & DISPLAY RESOLUTION 4 BATTERY STATUS INDICATION 5 POWER ON SETUP 5

Adam Equipment. BFW Platform Scales. Software rev P.N , Revision C- December 2011

Transcription:

ESA SERIES ELECTRONIC BALANCE ESA_AWT35-500064_AD.book

Declarations of compliance United States This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. Canada This digital apparatus does not exceed the Class A limits for radio noise emissions from digital apparatus set out in the Radio Interference Regulations of the Canadian Department of Communications. Le présent appareil numérique n émet pas de bruits radioélectriques dépassant les limites applicables aux appareils numériques de la Classe A prescrites dans le Règlement sur le brouillage radioélectrique edicté par le ministère des Communications du Canada. EMC compliance The following warning may be applicable to your machine. WARNING: This is a class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures.

Declaration of Conformity Manufacturer Type Salter Brecknell ESA Corresponds to the requirements of the following EC directives:- Electro Magnetic Compatibility Low Voltage Directive: The application harmonised standards are: EMC 89/336/EEC LVD 2006/95/EC EN60950-1: 2002, EN61000-6-3: 2001 EN61000-6-1:2007 A copy of the original signed Declaration of Conformity is available on request.

Avery Weigh-Tronix group of companies 2008. All rights reserved. No part of this publication may be reproduced, stored in an electronic retrieval system, or transmitted in any form or by any means, electronic, mechanical, photocopying, recording or otherwise without the prior written consent of the copyright owner, or as permitted by law or under licence. Full acknowledgment of the source must be given. Salter Brecknell is a registered trade mark of the Avery Weigh-Tronix group of companies. This publication was correct at the time of going to print however, Avery Weigh-Tronix reserves the right to alter without notice the specification, design, price or conditions of supply of any product or service at any time.

ESA Series Precision Balance Thank you for purchasing the Model ESA precision balance. Please read all operating instructions carefully before using and note the following items to ensure accurate readings. 1.0 Description The ESA balances use a high precision load cell and microcomputer for simple operation with accurate, stable weight readings displayed on the large liquid crystal display. This balance is an excellent choice for laboratory use and educational applications, however, it is not recommended for use in production lines, food preparation areas or any other environment where high heat, cold, humidity or vibration are present. Do not overload the balance. This will damage the load cell and void the warranty. Inspect the platter, draft shield, housing and AC adapter regularly for damage. Refer to the troubleshooting chart at the end of this manual for more details. Do not attempt to repair the balance if you have a problem. Contact your local Salter Brecknell representative. 2.0 Unpacking Please check the contents of this box carefully. Your ESA balance should come with one of each of the following: Electronic Balance Stainless Steel Weighing Platform 6V AC Power Adapter User Manual 1

3.0 Installation Place the balance on a stable, level surface. Level the balance using the adjustable feet and level bubble. Remove the protective film from the stainless steel platform. Gently place the weighing platform on the mounting posts on the top of the base of the balance. The base s posts should fit easily into the holes on the bottom of the platform and the platform should be flat and level. Note: Do not force the platform as this can damage the balance. Connect the AC adapter to the receptacle at the rear of the balance. Connect the AC adapter to an appropriate power outlet. Note: You can also operate this unit using batteries instead of the supplied AC adapter. Batteries are not included with the unit. 4.0 Key Functions The following figure shows the front panel with six push buttons Each key function is explained on the next page.. On/Off Count Cal Tare Mode Units g/oz On/Off Count Cal Tare Mode Units Turns the balance on or off or returns balance to normal weighing mode. Places the balance in piece count mode. (stands for Calibrate) Enters calibration mode. Used to tare off, up to 100% of balance capacity, an empty container and to reset the balance to zero. Use of tare with a weight or container reduces the scale s capacity by the tare value stored. Also works like Enter in some modes. Toggles the backlight on or off. To extend battery life, turn backlight off. Also toggles between options in calibration mode. Allows you to scroll through and select from the available units (g, oz, ozt, dwt, lb) as well as count (ct) and percentage (%). 2

5.0 Scale Operation This section covers the scale operations of weighing and counting. Note: Always make sure that the balance is on a clean, dry, level and solid surface. Simple Weighing 1. Turn the balance on. The balance will go through a series of tests and then display all zeroes (0 s). 2. Press the Units key until the desired unit of measure is displayed on the far right of the display. 3. Press the Tare key if the display no longer reads zero. 4. Place item(s) to be weighed on the weighing platform. The weight will be displayed with the appropriate unit of measure next to it. 5. Remove the item(s) from the balance and repeat steps 2-5 to continue weighing. Tare Weighing If you want to do net weighing, such as weighing objects in a container, follow these steps. 1. Turn the balance on. The balance will go through a series of tests and then display all zeroes (0 s). 2. Press the Units key until the desired unit of measure is displayed on the far right of the display. 3. Place the container to be tared on the weighing platform and press the Tare key. The display should return to zero. 4. Place item(s) to be weighed in the container. The weight will be displayed with the appropriate unit of measure next to it. The weight displayed is the net weight and does not include the weight of the container. 5. Remove the item(s) from the container and repeat steps 3-5 to continue weighing with the same container. Note: If you remove the container, the balance will show a negative weight. Press the Tare key to return the balance to zero. 3

General Counting Function The ESA series will count parts based on the weight of a reference sample of 5, 10, 20, 30, 40 or 50 pieces. For best results, the pieces used should be of equal weight. Also, the larger the sample, the more accurate your counts will be. Once you have created this reference sample, it will remain in memory until a new sample is recorded, even when the balance if turned off. This section explains the counting function in further detail. 1. Turn the balance on and allow it to come to zero. 2. Press the Count button. The balance will display CON pcs. Note: If you are using a container to hold the pieces, place the empty container on the weighing platform at this point. 3. Press Tare. The balance will display the message Add 5. 4. Press Mode until the number of pieces in your sample is displayed. You can choose from 5, 10, 20, 30, 40 or 50. 5. Place your sample on the platform and press Tare. 6. There will be a short pause and then the balance will show the number of the sample on the screen. Note: If the balance displays the message PC Err, the sample size was too small for the balance and a larger sample will be required. 7. Remove the sample from the balance. The balance is now ready to count. 8. Add pieces to the balance / container. The balance will show the number of pieces on the display. 9. Press the Units key to exit piece counting and return to normal weighing. You can return to piece counting by pressing the Units key until pcs is displayed. 6.0 Calibration Occasionally, you may need to calibrate your balance with an appropriate weight. There are two types of calibration possible: sensitivity calibration and linear calibration. Linear calibration should only be attempted by a qualified service technician with correct weights. This section explains how to perform each type of calibration. 4

Sensitivity Calibration 1. With the scale in regular weighing mode, press the Tare button to zero the balance. 2. Press the Cal button.the balance will show Scale. 3. Press the Tare button. The balance will display one of the accepted calibration weights. Note: The balance can only be calibrated in grams. 4. Press the Mode key to toggle between available calibration weights. 5. Press Tare. The balance will flash 0 briefly and then flash the calibration weight. 6. Place the correct amount of weight (in grams) on the platform and press the Tare button. 7. The calibration weight will continue to flash briefly and then become stable. 8. Once the weight is stable, remove the weight from the balance. The scale has now been calibrated and is in regular weigh mode. 9. Press the Tare key if the scale does not return to zero. Linear Calibration 1. In regular weighing mode, press the Tare button to zero the balance. 2. Press the Cal button. The balance will show Scale. 3. Press the Mode button. The balance will show Line 4. Press Tare. The balance will flash 0 briefly and then flash the first calibration weight. 5. Place the correct amount of weight (in grams) on the platform and press the Tare button. 6. The balance will flash the next calibration weight. 7. Place the appropriate amount of weight on the weighing platter and press Tare. 8. The calibration weight will continue to flash briefly and then become stable. 9. Once the weight is stable, remove the weight from the balance. The scale has now been calibrated and is in regular weigh mode. 10. Press the Tare key if the scale does not return to zero. 5

7.0 Print and Communications The ESA balances can be connected to a PC or appropriate printer using a null modem cable (not supplied). The balance will transmit the gross or net weight and unit or the number of pieces if you are using the piece counting function. Connecting to PC 1. Connect the appropriate cable to the 9 pin D connector on the balance. 2. Connect the other end to an available COM port on your PC. 3. Start HyperTerminal or similar utility. The following diagram shows the wiring / pinouts of the cable and RS232 data. Pin Computer Balance Pin RS232 Data 1 Empty 1 Baud Rate = 9600 2 RXD RXD 2 Data Bits = 8 3 TXD TXD 3 Parity = No 4 4 Stop Bits = 1 5 Ground Ground 5 6 6 7 7 8 8 9 Empty 9 6

Change Print Setting You can select either Continuous Print or Print When Stable, depending on your needs. 1. Remove all weight (except platter) and power the balance off. 2. Power the balance on. 3. During countdown (9999.99, 8888.88, 7777.77), press the Mode key. The balance displays F1 A2t. 4. Press the Mode key. The balance displays F2 prt. 5. Press the Tare key. 6. Press the Mode key to toggle between P2t6 (print when stable) and PCon (continuous print). 7. Press the On/Off key when finished. The balance powers off and the changes are saved. 8. Connect the balance to the printer or other device. 9. Power the balance on. Care and Maintenance Your precision balance does not require a lot of maintenance, however, there are a few things you can do to keep your balance operating properly. 1. Keep the balance housing and weighing platform clean and free of debris. Clean with a soft cloth dampened with detergent as necessary. 2. Unplug the AC adapter when not in use. 3. Remove batteries for long term storage. (See the section on battery replacement.) Battery replacement You can expect approximately 15 hours of use when powering the balance with batteries. Use only alkaline batteries of the correct size and pay close attention to the markings (+ or -) inside the battery compartment. 7

Your balance should look similar to one of the two pictured below. Detailed instructions are for models using screws to hold the lid in place only. 1. Remove the two screws holding the battery compartment lid on the bottom of the scale. 2. Gently pry up the battery cover and remove. 3. Insert the correct number of batteries. 4. Replace cover and tighten screws. 5. Return balance to upright position and press the On/Off button to turn the scale on and resume normal weighing or counting functions. Error Codes and Troubleshooting If the scale shows something unexpected, you may be able to resolve it yourself. Many times, the error can be resolved by powering the scale off and then back on again. The table on the next page shows some basic troubleshooting tips to try before calling for service. 8

Table 1: Error Codes and Troubleshooting Problem Cause(s) Solution(s) Err 0 Err 1 Err 2 Err 3 F1 AZT F2 Cnt Incorrect Weight Reading No Display This typically indicates that the platform is too light. Overweight error. The sample being weighed is too heavy for the balance. Underweight error. This error is similar to Err 0 as it indicates that the platform is not properly installed. Non-zero error. This indicates that there was weight on the balance during power up. A button was pressed during power up. A button was pressed during power up. Balance was not set to zero or was not calibrated. Power adapter not properly connected or batteries are dead. Ensure that the stainless steel cover is properly in place. Turn the scale off and remove the platform. Replace the platform and reapply power. If error persists, the weight sensor or circuit board may be faulty and you should contact your distributor. Remove some of the sample. If sample is within the balance capacity, balance may need to be calibrated. Power off the balance and re-seat the platform before reapplying power to the balance. The balance may need to be calibrated. Remove any weight(s) from the platform, turn the balance off and back on. Turn the balance off and back on again. Turn the balance off and back on again. Press Tare to zero the balance. Calibrate the balance as necessary. Reconnect power adapter or replace batteries. 9

8.0 Specifications Table 2: Specifications MODEL Capacity & Resolution STD Deviation (e) Linearity (e) Corner Deviation (e) Tare Range Overload Capacity Stabilization Time (s) Applicable Temperature Range ESA-150 ESA-300 150 x 0.005 g 300 x 0.005 g ESA-600 ESA-1200 ESA-3000 ESA-6000 600 x 0.01 g 1200 x 0.02 g 3000 x 0.05 g 6000 x 0.1 g 1 1 1 100% Maximum Capacity+9e 3 seconds 10-35 C 50-95 F Power Source Pan Size AC Adapter (included)or 6 AA Batteries (not included) 120 mm diameter (approx. 4.7 in.) AC Adapter(included) or 8 AA Batteries Batteries are not included. 172 mm x 172 mm (approx. 6.8 in x 6.8 in) Housing Dimensions Net Weight 832 g 1.8 lbs 251 (L) x 172 (W) x 58 (H) mm (approx. 9.9 x 6.8 x 2.3 in) 1560 g 3.4 lbs 10

UK and EUROPE Salter Brecknell Weighing P.O. Box 9533 Smethwick West Midlands B66 2 TE Tel: +44 (0) 870 444 6132 Fax: +44 (0) 870 010 2241 Email: sales@salterbrecknell.co.uk Web Site: www.averyweigh-tronix.com USA Salter Brecknell Weighing Products USA 1000 Armstrong Drive Fairmont, MN 56031 Toll Free: 800-637-0529 Tel: 507-238-8702 Fax: 507-238-8271 Email: sales@salterbrecknell.com Web: www.salterbrecknell.com PN AWT35-500064 AC October 2008