Bus Differential and Breaker Failure Relay. Advanced bus protection with built-in breaker failure detection

Similar documents
Bus Differential and Breaker Failure Relay. Advanced bus protection with built-in breaker failure detection

Bus Differential and Breaker Failure Relay. Advanced bus protection with built-in breaker failure detection

SEL-487B. A Powerful Solution for Busbar Differential Protection. Bus Differential and Breaker Failure Relay

Protection, Automation, and Control System. Combine subcycle line protection with complete substation bay control

High-speed transformer differential protection for up to five terminals

Protection, Automation, and Bay Control System. Advanced feeder protection and complete substation bay control in one economical system

A low-cost, economical solution for distribution feeder protection

SEL-487B Bus Differential Relay

Advanced Line Differential Protection, Automation, and Control System. Combine subcycle line protection with traveling-wave fault locating

Advanced distribution feeder solution with integrated protection, monitoring, and control

2 ms arc-flash protection and feeder relay in one platform

Real-Time Automation Controller (RTAC) Powerful, reliable, and secure multifunction controller

Protect induction and synchronous motors with one relay.

Maximize process uptime with the SEL-patented motor thermal model.

SEL Time-Domain Link (TiDL ) Technology

Built for speed, security, and simplicity

Lightweight and flexible recloser control for single-phase applications

2 ms arc-flash protection and feeder relay in one platform

Protect induction and synchronous motors with one relay

One relay for safety and process continuity

Modular Real-Time Automation Controller. Dependable control for harsh environments in a fully integrated, flexible platform

SEL-587Z High-Impedance Differential and Overcurrent Relay

SEL Real-Time Automation Controller (RTAC)

RTAC. SEL Real-Time Automation Controller. Integrate station control, a web-based HMI, and logging through one reliable system.

Protection, Monitoring, and Control System for Distribution Substations ALARM HISTORY SYSTEM COMM. On-Line Documentation TRANSFORMER 12 MW

Bus Bar Protection Relay B-PRO 4000

SEL-2730M. Reliably Control and Monitor Your Substation and Plant Networks. Managed 24-Port Ethernet Switch

Substation Automation Products. High impedance differential busbar protection REB650 Relion 650 series

Comprehensive protection for large, medium, and small generators

NERC PRC-002 Recording Solutions

SEL-401 Data Sheet. Protection, Automation, and Control Merging Unit. Major Features and Benefits

Powerful and flexible recloser control for many popular reclosers

SEL-311C-1 Transmission Protection System

SEL Protection, Automation, and Bay Control System

Substation Automation Products. Bay control REC670/650 Relion 670 and 650 series

SEL-421 Data Sheet. Protection, Automation, and Control System With Sampled Values. Major Features and Benefits

SEL-421-4, -5 Protection and Automation System

MiCOM Agile P746. Grid Solutions. Key Benefits. Numerical Busbar Protection. A Combination of Speed, Security and Selectivity. About MiCOM P40 Agile

Substation Automation Products. Line differential protection RED670 Relion 670 series

SEL-2440 Discrete Programmable Automation Controller

SEL-2414 Transformer Monitor

GE Multilin 350 Feeder Protection Relay Specifications

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

Substation Automation Products. Transformer protection RET670/650 Relion 670 and 650 series

DS Agile C264. Grid Solutions. Dual-bay Modular Substation Controller. Multi-function Controller. Automation and Control. Advanced Communication

Transformer Protection Relay

SEL-387E Current Differential and Voltage Protection Relay

SEL-2411P Pump Automation Controller Data Sheet

SEL-551/SEL-551C Overcurrent and Reclosing Relay

Recloser Controller for feeder protection and automation siemens.com/distribution-automation

Substation Automation Products. Line distance protection REL670/650 Relion 670 and 650 series

U lity network. system Q sys. Interconnected P sys. P load Q load. P gen Q gen. Generator network

SEL-400 Series TiDL Quick-Start Guide

Siprotec 7ST61 / 7ST63

High-Speed Railroad Operations

KEY BENEFITS APPLICATIONS FEATURES

SR489 SR489. Generator Management Relay. Economical protection, metering, and monitoring functions for small and medium sized generators.

SEL-2030 Communications Processor

UR Universal Relay Series

Designed, built, and tested for troublefree operation in extreme conditions

DGSZV-EP DIGITAL GALVANIC LONGITUDINAL DIFFERENTIAL PROTECTION. Application field

www. ElectricalPartManuals. com Protective Relays HIGHLIGHTS PROTECTIVE FUNCTIONS ixp-420 Transformer Protection Relay

Distributed bus protection application in a platform for process bus deployment in the SMART SUBSTATION

Identify and understand the operation of common bus. After this presentation you will be able to: Identify common bus arrangements

SEL-351A Protection System Data Sheet

SIPROTEC 7SC80 Feeder Protection and Automation Answers for infrastructure and cities.

Perfect protection smallest space

Substation Automation Products. Generator protection REG670/650 Relion 670 and 650 series

Content REF615 Technical Presentation

Relion 615 series Feeder Protection and Control REF615 Ver. 2.0 Technical Presentation

Busbar protection REB 670

SEL-351-5, -6, -7 Protection System Data Sheet

DIGITAL RELAY OF PROTECTION AND AUTOMATION SERIES PC83 AND PC830

Major Features and Benefits

GE Power Management. UR F60 Feeder Management Relay An integrated feeder protection and metering solution

The SEL-700G Generator Protection Relay is the newest member of the SEL-700 series platform. It combines the protection features of the proven

TWO-WINDING TRANSFORMER DIFFERENTIAL

Major Features and Benefits

Deploying Digital Substations: Experience with a Digital Substation Pilot in North America. Harsh Vardhan, R Ramlachan GE Grid Solutions, USA

Type SDR reclosers plus controllers and type B-2 recloser bypass switch assembly usa.siemens.com/mediumvoltage

Real-Time Automation Controllers (RTACs) Economical, multifunctional, compact real-time automation control

NPW800R RETROFITTING. Power and Volatge Protection Relay

Operator Controls and Reclosing Eliminate expensive control switches and wiring. Selectively reclose with synchronism and voltage checks.

Protection Relays PHASE & RESIDUAL OVERCURRENT

750/760 Feeder Management Relay Instruction Manual

Relion 615 series Line Differential Protection and Control RED615 Ver. 2.0 Technical Presentation

We will discuss two types of loss-of-potential (LOP) logic during this presentation:

IDM DATA ACQUISITION SYSTEM

Relion 615 series Transformer Protection and Control RET615 Ver. 2.0 Technical Presentation

Non-conventional instrument transformers Advanced GIS substations with IEC LE process bus

SEL-321 Data Sheet. Phase and Ground Distance Relay, Directional Overcurrent Relay, Fault Locator

SEL University. Power Through Knowledge. Dr. Héctor J. Altuve Ferrer Dean of SEL University

SEL Event Report Frequently Asked Questions

SIA-B. Overcurrent & Earth Fault Protection Relay for Secondary Distribution. Dual & Self Powered / Standard CTs. Main characteristics

DRTS 33. The new generation of advanced three phase relay test set

MiCOM P122C Time-Overcurrent Protection

g GE Power Management UR - The Universal Relay

MiCOM P721 & P723. Numerical High Impedance Differential Relay. Protection Relays. Customer Benefits

Merge physical security and cybersecurity for field operations.

Function permission: yes/no. Operating range: 0.10 to 30 xin (step 0.01) Operating time: 0.02 to 300 s (step 0.01 s) Activation level 100%

Transcription:

SEL-487B Bus Differential and Breaker Failure Relay Advanced bus protection with built-in breaker failure detection Protect busbars with up to 21 terminals using high-speed, low-impedance bus differential elements. Implement distributed bus protection and simplify copper wiring using TiDL technology. Improve system testing and post-fault analysis with comprehensive monitoring, metering, and event recording capabilities.

Functional Overview Zone 1 52-1 89 52-2 89 89 Tie Breaker 52-6 52-52-4 52-5 50 50 50 50 50 50 50 51 51 51 51 51 51 51 50BF 50BF 50BF 50BF 50BF 50BF 50BF 89 89 89 89 Zone 2 27 59 PT ANSI Number/Acronyms and Functions 16 SEC Access Security (Serial, Ethernet) 27/59 Over-/Undervoltage 50 Overcurrent 50BF Breaker Failure Overcurrent 51 Time-Overcurrent 85 RIO SEL Mirrored Bits Communications 87 Current Differential DFR Event Reports HMI Operator Interface LGC Expanded SELogic Control Equations MET High-Accuracy Metering RTU Remote Terminal Unit SER Sequential Events Recorder Additional Functions SBM Station Battery Monitor TiDL Time-Domain Link Technology* 87 Zone 1 87 Zone 2 1 Copper or Fiber-Optic *Optional Feature 16 S EC MET RTU SBM SER 4 EIA-22 2 Ethernet 1 * 1 IRIG-B 85 RIO DFR HMI LGC SEL-487B

Key Features Low-Impedance Bus Differential Protection The SEL-487E Bus Differential and Breaker Failure Relay protects bus systems with up to 21 terminals (21 CTs per relay, 6 CTs with a three-relay scheme), 6 protection zones, and independent check zones. To optimize protection security, each check zone will supervise a designated phase in the system, and a patented open CT detection algorithm blocks potential misoperations during open or shorted CT conditions. Differential and directional current elements provide increased security and fast fault detection. You can also reduce protection costs with built-in breaker failure protection. Flexibility Implement different ratio CTs and nondedicated CTs with the SEL-487B. The flexibility built into the settings allows you to eliminate complex wiring by using CT ratios that differ by up to a factor of 10:1. Take advantage of the same CTs for differential protection, metering, backup relaying, and other functions. Distributed Bus Protection Simplify copper wiring and reduce commissioning costs by applying the SEL-487B in a distributed bus protection scheme using TiDL technology. In a TiDL system, the SEL-2240 Axion TiDL node is located out in the yard and acts as a field module. The Axion digitizes analog signals and transports the data over point-to-point fiber-optic cable to the SEL-487B (located in the control house). The Axion s 24 khz sampling rate improves the accuracy of the protection signals, and as a TiDL node, its modular architecture allows you to select the number of analog and digital input modules to match the application. The settings in the SEL-487B remain the same as before, providing consistency and simplicity in commissioning. Monitoring and Metering The 487B provides accurate, timely monitoring and metering of busbar, feeder, and substation signals. Terminal currents, breaker and disconnect positions, station dc voltage levels, and threephase voltage are continuously monitored and updated. The relay also provides event reports and a Sequential Events Recorder (SER) to simplify post-fault event analysis. TiDL Technology Modernize your substation by applying the TiDL-enabled SEL-487B and SEL-2240 Axion TiDL nodes. By deploying Axion nodes near the primary equipment, you can convert instrument transformer and digital I/O signals from analog to digital signals and transport them into the control house over optical fiber to the SEL-487B Relay. This simple and secure digital secondary system solution is easy to implement, with no external time source or network engineering required. Replacing copper wires with fiber-optic cables increases safety, reduces costs associated with using copper wires, and limits the impact of electromagnetic interference.

Product Overview EIA-22 front serial port is quick and convenient for system setup and local access. LCD automatically scrolls between custom displays. Easy-to-use keypad aids simple navigation.

Front-panel LEDs can be programmed to indicate custom alarms and provide fast and simple information to assist dispatchers and line crews for rapid power restoration. Programmable operator pushbuttons with user-configurable labels allow for front-panel customization.

Product Overview Chassis and mounting options accommodate users application needs. Communications protocols include FTP, Telnet, DNP LAN/WAN, the Parallel Redundancy Protocol (PRP), the IEEE 1588 Precision Time Protocol Version 2 (PTPv2)** and IEC 61850.* 21 current and voltage channels accommodate different busbar configurations. *Optional **For PTP implementation, Ports 5A and 5B must be ordered as an option.

Product Overview TiDL Option 4U chassis with horizontal mounting options (panel or rack) accommodate users application needs. The commission button prompts the relay to communicate with the SEL-2240 Axion TiDL nodes. LEDs indicate the connection status to a remote Axion TiDL node on a per-port basis. LEDs indicate a valid configuration and successful commissioning. Eight 100 Mbps fiber-optic EtherCAT ports allow the TiDL-enabled relay to connect with eight remote Axion nodes and to receive remote analog and digital data.

Applications Differential Protection The SEL-487B includes six independent current differential elements, and each one provides: Fast operate times for all busbar faults. Security for external faults with heavy CT saturation. Security with subsidence current present. High sensitivity to busbar faults. Minimum delay for faults evolving from external to internal. CT Supervision For each zone, sensitive current differential elements detect differential current resulting from a differential element that is not well balanced (i.e., wrong CT ratios). If the conditions persist for longer than a user-specified delay, the element asserts an alarm that can be used to generate an external alarm and/or block the zone. Current (amperes) 20 10 0 0 0 IO1 IO2 Internal Fault Detection Fault Inception (<1 cycle).05.10.15.20 Time (seconds) Differential element operation in less than one cycle for internal faults. 100 Advanced Open-CT Detection Logic The patented open-ct detection logic improves the security of the current differential element. It ensures current differential bus zones will not misoperate due to terminals that cannot be properly measured. This advanced logic, when implemented, will block differential element misoperations that occur under open- or shorted-ct conditions. The open-ct detection logic monitors the CT terminals in every bus zone to detect when a contributing CT has failed. Current (amperes) 50 0-50 50 0-50 100 150 0 IO1 IO2 Internal Fault Detection (No Differential Element Operation).05.10.15.20 Time (seconds) Differential element remains secure for external faults with heavy CT saturation.

Voltage Elements CT Supervision Supervise current differential tripping within the relay by using voltage elements. Three separate voltage elements consist of two levels of phase under- and overvoltage elements and two levels of negativeand zero-sequence overvoltage elements for each of the three analog voltage quantities measured. Current Input I 01 Current Input I 21 I OP Differential Element Slope 2 Slope 1 I RT Trip Output Integrated Overcurrent Protection Ten overcurrent curves are available for each current input. Each torquecontrolled time-overcurrent element has two reset characteristics. There is also one level of instantaneous and definite-time elements available for each current input. External Fault Fault Detection Logic Internal Fault High-Security Operate Slope Standard Operate Slope Restraint Zone External faults are detected by directional elements within the relay. When an external fault is detected, the relay enters a high-security mode and dynamically selects a higher slope for the differential elements, making them more secure during the fault. Breaker Failure Detection The SEL-487B includes complete breaker failure protection, including retrip, for each terminal. Internal breaker failure is determined by predefined protection schemes that allow different types of trip signals and current flow conditions. External breaker failure device inputs can be substituted for the internal breaker failure schemes while providing individual or identical responses to each breaker failure condition. Amperes 50 0 50 100 150 Open-Phase Detection Subsidence Open-Phase Detection Traditional Overcurrent Dropout 0 0.02 0.04 0.06 0.08 0.1 0.12 0.14 0.16 0.18 0.2 Time Offset: 0 Seconds High-speed open-pole detection logic detects open-pole conditions in fewer than 0.75 cycles to reduce breaker failure coordination times.

Dynamic Zone Configuration The SEL-487B dynamically assigns the input currents to the correct differential elements without the need for additional auxiliary relays. Connect the digital inputs from the busbar disconnect and breaker auxiliary contacts directly to the relay. SELogic control equations and zone selection logic will correctly assign the currents to the differential elements, even for complex bus arrangements as shown (upper example). Note that the SEL-487B automatically includes the Zone 4 currents in Zone when disconnect switch DS is closed (lower example). North Helium Zone 1 DS2 Zone 2 East Boron DS1 Argon Lithium Zone Silicon Krypton South DS Zone 4 West Neon Sodium =>>ZONE BUS PROTECTION Rinadel Station Terminals in Protection Zone 1 HELIUM SILICON Bus Zones in Protection Zone 1 NORTH Terminals in Protection Zone 2 BORON ARGON LITHIUM Bus Zones in Protection Zone 2 EAST Terminals in Protection Zone SILICON KRYPTON Bus Zones in Protection Zone SOUTH Terminals in Protection Zone 4 SODIUM NEON Bus Zones in Protection Zone 4 WEST =>> North Zone 1 DS1 DS2 Zone 2 East Zone Silicon South DS West =>>ZONE BUS PROTECTION Rinadel Station Terminals in Protection Zone 1 HELIUM SILICON Bus Zones in Protection Zone 1 NORTH Terminals in Protection Zone 2 BORON ARGON LITHIUM Bus Zones in Protection Zone 2 EAST Terminals in Protection Zone SILICON KRYPTON SODIUM NEON Bus Zones in Protection Zone SOUTH WEST =>> Helium Boron Argon Lithium Krypton Neon Sodium

Three Independent Check Zones Supervise up to Six Differential Bus Zones In complex busbar layouts, the SEL-487B uses disconnect auxiliary contact status to define current differential bus zones and supervises these zones on a per-phase basis with the independent check zone feature to prevent misoperation due to a discrepancy. Check Zone Key Features Powerful SELogic control equations allow you to create your own custom applications. Provides secure supervision for bus zones. Supervises bus zones on a per-phase basis, independent of terminal auxiliary disconnect status. Processes its logic independently of all bus zones. Fits a wide variety of applications and protection philosophies, with independent pickup and slope settings. Three-Relay Bus Protection Application For up to 21 Terminals You can configure a check zone for every phase, encompassing all terminals at the station (except bus coupler and sectionalizing breakers), independent of the disconnect auxiliary contact status. Check Zone Zone 1 52 Zone 2 52 52 SEL-487B 52 52 52 TR 1 TR 2 FD 1 FD 2 FD This example shows a single SEL-487B protecting a system with two -phase bus zones and increasing security by applying a check zone per phase.

Distributed Bus Protection Using TiDL Technology SEL TiDL technology provides a simple and secure solution, enabling you to: Eliminate complexity no network engineering or external time reference is required. Achieve strong cybersecurity by using point-to-point fiber connections, an isolated network, and no Ethernet switches. Implement state-of-the-art protection using the familiar SEL-487B settings and protection schemes. Substation Yard Fiber-Optic Cable Line 1 Line 2 Line SEL Axion SEL Axion SEL Axion SEL Axion SEL Axion SEL Axion SEL Axion SEL Axion Feeder 1 Feeder 2 Feeder Feeder 4 SEL-487B Control House

Automation and Control With 2 local control points, the SEL-487B allows you to eliminate traditional panel control switches. You can set, clear, or pulse local control points with the programmable front-panel pushbuttons and display. Using SELogic control equations, you can program the local control points to implement your control scheme. The 2 remote control points help eliminate RTU-to-relay wiring. Using serial port commands, you can set, clear, or pulse remote control points. You can also incorporate the remote control points into your control scheme via SELogic control equations and apply remote control points for SCADA-type control operations, such as trip and group selection. The SEL-487B control logic can replace the following: Traditional panel control switches RTU-to-relay wiring Traditional latching relays Traditional indicating panel lights Panel meters acselerator QuickSet SEL-500 Software Develop SEL-487B settings and busbar configurations offline with acselerator QuickSet. The system automatically checks interrelated settings and highlights out-of-range settings. You can transfer settings created offline to the SEL-487B by using a PC communications link. Graphical Logic Editor (GLE) Simplify the process of configuring your SEL-487B using the GLE in acselerator QuickSet. With the GLE, you can view SELogic equations graphically, making it easier to document settings files for validation and commissioning. Convert existing SELogic control equations to easy-to-read diagrams, and save diagrams with your QuickSet settings.

Accessibility and Communications Simplify System Testing and Post-Fault Analysis The SEL-487B event-reporting capabilities help improve understanding of even the most complex protective scheme operations. Eliminate external recorder and metering requirements with oscillographic and binary COMTRADE event reports and SER. SER Gain a broad perspective of relay element operation with the SER in the SEL-487B. Items that trigger an SER entry are selectable and can include as many as 250 monitoring points, such as input/output, change of state, element pickup/dropout, and more. The relay SER stores the latest 1,000 events, which are available through the SER command. The latest 200 events are also viewable via the front-panel LCD. SEL-5601-2 synchrowave Software Event provides powerful analytic capabilities. Access Useful Information Metering quantities include primary and secondary voltage and current magnitudes as well as angles for each terminal. Zone information displays primary or secondary current and voltage for each terminal. The polarity of each CT and the bus zones in each of the protective zones at the station are also included. Differential metering shows the operating and restraint currents for each zone as well as the reference current. Battery monitoring provides warning and alarm thresholds that can be monitored with the SEL-202 Communications Processor and the SEL-50 Real-Time Automation Controller (RTAC). Trigger messages via local display, phone, or other devices. synchrowave Event displays individual operate and restraint currents for three different protection zones.

Integrate With Ethernet Networks You can apply SEL-487B Relays with Ethernet directly to a local network or through an SEL communications processor. Use DNP LAN/WAN or Modbus TCP to quickly send information through your networks. Provide information to the right people for improved system performance. Transfer data with high-speed Ethernet for fast HMI updates and file uploads. Use popular Telnet applications for easy terminal communication with SEL relays and other devices. Combine IEC 61850 technology, an Ethernet network, and the SEL-487B for the fastest overall performance of IEC 61850 relays for substation automation and control. Access basic relay information on a standard Ethernet network with the built-in web server. View the relay status, Sequential Events Recorder (SER) reports, metering information, and settings. Web server access requires the relay password and is limited to read-only viewing of information. Simplify wiring and installation by receiving a time signal over existing Ethernet networks. The Simple Network Time Protocol (SNTP) makes a good backup to more accurate IRIG-B time synchronization, or use the optional high-accuracy Precision Time Protocol Version 2 (PTPv2) in place of IRIG-B. Support seamless failover for Ethernet communications with the Parallel Redundancy Protocol (PRP), which allows communications network redundancy using two separate but identical local-area networks (LANs). SEL-421 SEL-421 SEL-55 SEL-2725 SEL-50 SEL-451 Typical Ethernet network configuration. SEL-487B

SEL-487B Specifications General AC Current Inputs (21 total) 5 A nominal 1 A nominal AC Voltage Inputs ( total) Serial Ethernet Precise-Time Input Processing Power Supply Operating Temperature 00 V L-N continuous rear-panel and 1 front-panel EIA-22 serial ports 00 57,600 bps Communications protocols include FTP, Telnet, DNP LAN/ WAN, PRP, PTPv2, and IEC 61850 (optional). Choose from the following media options: Two 10/100BASE-T twisted-pair network ports Two 100BASE-FX fiber-optic network ports One 10/100BASE-T twisted-pair network port and one 100BASE-FX fiber-optic network port Demodulated IRIG-B time input and PTPv2 AC voltage and current inputs: 8,000 samples per second Protection and control processing: 12 times per power system cycle 24 48 Vdc 48 125 Vdc or 110 120 Vac 125 250 Vdc or 110 240 Vac 40 to +85 C ( 40 to +185 F) Note: LCD contrast is impaired for temperatures below 20 C ( 4 F) and above +70 C (+158 F). Making Electric Power Safer, More Reliable, and More Economical Tel: +1.509.2.1890 Email: info@selinc.com Web: www.selinc.com 2017 by Schweitzer Engineering Laboratories, Inc. PF0006 20171010