Dear MyChron Light MRT Owner

Similar documents
Dear MyChron 3 Owner

Race Studio 2. Race Studio 2 Configuration User s manual. Race Studio Configuration: user s manual 1

Dear MyChron Light TG Owner

MyChron5 - MyChron5 2T USER GUIDE

Dear MyChron owner

Kart Price list Ver July 2018

ebox Gold/Extreme for MyChron4 User Manual

TECHNICAL DOCUMENTATION 10/10/2005 GAUGE. MyChron 3 LOG BIKE. Introduction. Notes: MyChron 3 LOG BIKE technical documentation Version 1.

LCU-ONE CAN connected to MXL QM and EVO3 QM User Manual

MyChron4 660 User Manual Release 1.02 INDEX

MyChron Light TG User Manual

DataPro Designer Quick Start Guide

Users Guide. UniWatch. Version Go faster faster. UNIPRO ApS

MXL PRO 05 PLUG & PLAY KIT FOR SUZUKI GSX R YOSHIMURA RACING HARNESS cc

Easy Installation and Advanced Functionality Fast Facts:

EVO3 Pro/Pista User manual

OPERATION INSTRUCTIONS

Version SmartyCam HD. Rev. 2

USER MANUAL UPDATED

Step 2. Complete device installation instructions.

EVO5 Logger USER GUIDE

Table of Contents. Table of Contents

VANTAGE CL1. Installation and use of the CL1 Karting Data Kit

MAN-652-OM1. 3 Oct 07 Revision G.R. G.A. 2 Jun 06 Revision A.G. G.A. 1 Feb 06 Revision A.G. G.A. Rev. Date DESCRIPTION Prepared Approved

TC-4 4 Channel Thermocouple Interface User Manual

24/7 Sprinkler Monitor. The Ultimate Rain/Freeze Sensor

HI HI N HI HI

EVO Dear EVO3 Pista/Pro Owner,

1. Introduction 2. Specifications 3. Symbol Definition and Button Location 4. Operation Instructions 5. Temperature Measurement 6.

350 SMART MANOMETER OPERATING INSTRUCTIONS

Flue Gas Analyzer. The Value Leader TM

CAN-EGT by DIYAutoTune.com

SPA Laptimer manual. The track side beacon beams infra-red across the track which is picked up by the small receiver connected to the laptimer.

SmartyManager User manual

MODERN DIGITAL CLOCK HIDDEN CAMERA SKU: MiniClockDeluxe

R X CAUTION! Some procedures must be followed to avoid damages to the vehicle. Accessories OPTIONAL. Wiring installation instructions

HI HI HI HI Portable Microprocessor Thermistor Thermometers

EnCell Battery Cell Monitor

HI HI N HI HI

Controller Pro Instruction Manual

CH1. Figure 1: M3 LOG Advanced

Users Guide. UniStop. Version 1.03 (Software version 1.05) Go faster faster. UNIPRO ApS

Laptimer, Revmeter and Data Logger MANUAL

USER GUIDE. Differential Thermometer Datalogger. Model HD200

INSTALLATION & USER MANUAL

Standalone version. Release 1.01

4-Channel Datalogging Thermometer

MINI CLOCK CAMERA HD HIDDEN CLOCK DVR SKU: MiniClockCamHD

ECU Bridge User Manual

RS Stock No Instruction Manual RS Input Data Logging Thermometer

3M Temperature Logger TL20/TL25 - Software Installation Guide

Mini Agg 1-10 (DC/AC)

DEIF A/S. Description of options. Option H4 Serial comm. CAT CCM communication Multi-line 2 version 2. Description of option Functional description

PRO ESC - LCD PROGRAM CARD USER MANUAL. The Fantom FR-10 PRO LCD Program Card only applies to the FR-10 PRO 1:10 scale, 2S, 160A brushless ESC.

Solo 2 GPS Lap Timer USER GUIDE

Playback & Download Module RECORD PAUSE

HI HI HI HI HI HI HI

WhisperPower Touch Display. User Manual Revision 1.2. WP 5.0 inch, WP 7.0 inch and WP 9.7 inch

Date 18/05/17. Operation and maintenance instructions for driver configurator QSet

RWD32S Software Tool. Operating Instructions. CE1U3344en Building Technologies

PRO III. User s manual (EN) Firmware V Serial nr. Save It! Copyright 2014 Alfano, S.A. Tous droits réservés. 1

ONE-TOUCH BUTTON CAMERA SKU: B3000

Omni II Version 2.9 Firmware Release

PROCKET PRO HL400-S SWIMMING

quick start manual F O R E R U N N E R 4 0 5

12/2013. Installation Guide & User Manual

Gavita Master Controller EL1

PITE 3926C Battery Data Logger User Manual

Controller Pro Instruction Manual

LCU ONE Analog User manual

WHIPPLE FLARE FLASH Instruction Manual

USER MANUAL. Heavy Duty Manifold Pressure Gauge. Model HD780. Additional User Manual Translations available at

INSTRUCTIONS. High Performance Electronic Components 9630 W. Irving Park Rd., Schiller Park, IL Phone (847) Fax (847)

DL Series NEWDOLBO OWNER S MANUAL. Simple Weighing Scale 9002-DL

Multi Units Humidity/Temperature Transmitter. HygroViewer Model JW300 User Manual

CRAGG RAILCHARGER Instruction Manual for 10DTC-12V 20DTC-12V 30DTC-24V 40DTC-12V 60DTC-12V

RS Stock No Instruction Manual RS Input Data Logging Thermometer

AiM User Manual. ECU Bridge. Release 1.09

Automotive Dynamometer

Standard operating procedure for temperature data logging in the field

AUTOMOTIVE DYNAMOMETER HARDWARE AND SOFTWARE

quick start manual FORERUNNER 50 with ANT+Sport wireless technology

DS400 / DS404. Software Installation and Operations Manual. DS400 Docking Station. (800) (734)

COMDEK INDUSTRIAL CORPORATION 9F-1,

from P.R.Engineering Ltd Tel:

Temperature-Humidity Sensor Configuration Tool Rev. A 1/25/

OPERATION MANUAL. Model : AM Wind speed measurement, pocket type, IP-65 CUP ANEMOMETER

Dear Customer. Table of Contents. Thank you for choosing a Hanna Instruments product.

Contents 1 Warnings, Cautions, and Notes Description Features... 1

WHIPPLE FLARE FLASH Instruction Manual

Race Keeper Pectel ECU Data Module User Guide v1.1 January 2012

OM-DLTT DATA LOGGER INSTRUCTIONS

Omni II Version 2.10 Firmware Release

owner s manual Garmin Mobile

OmniLT Version 2.10 Firmware Release

SL 200 INTEGRATING-AVERAGING SOUND LEVEL METER

AquaShock ph Meter K

IS-S0108 Single Switch Solution

BDL-SERIES BATTERY DATA LOGGER

WHIPPLE FLARE FLASH INSTRUCTION MANUAL

Transcription:

Dear MyChron Light MRT Owner The new MyChron Light MRT is an evolution of the well known MyChron, that, since 1996, has been constantly improved in terms of dimensions, recording capability and reliability. Its unbelievably small dimensions, the internal batteries, the automatic power off feature, the amount of data recordable in the internal not volatile ram memory and the very good price/features ratio make MyChron Light MRT a great tool to monitor the kart engine as well as kart and driver performances. AIM Customer Service is available every day from 9 to 5 and at most all the major races throughout the country, to provide you with personal assistance. If you have any question, need help, or want to give us feedback, please visit our website,. Thank you for your MyChron Light MRT purchase! 1

AIM headquarter in Cernusco Sul Naviglio (MI) Italy 2

SUMMARY Getting Started with MyChron Light MRT... 5 MyChron Light MRT and its parts:... 7 The Display... 7 The Keyboard... 8 The RPM Cable... 9 The Thermocouple... 10 How to use MyChron Light MRT... 11 Configuration function... 12 Other functions... 14 Utility functions... 15 3

AIM Srl Via Cavalcanti, 8 20063 Cernusco Sul Naviglio Milan - Italy Tel.: +39.02.92.90.571 Fax: +39.02.92.11.80.24 4

Getting Started with MyChron Light MRT Aim has developed and tested your MyChron Light MRT to provide you precise and accurate results. Here are the parts of your system With reference to Figure 1 MyChron Light Display CPU (1); RPM sensor. (3); Thermocouple in alternative you can have: Water Sensor (2), Exhaust Gas Sensor (4) or Under spark Temperature Sensor (5); Water Temperature Sensor can be provided with an M5 or with a 1/8 connection; Optional water thermocouple M5 fitting (6); Thermocouple extension cable (not shown). Fig. 1 MyChron Light MRT standard kit 5

Also available MyChron Light MRT Figure 2 MyChron Light MRT accessories 6

MyChron Light MRT and its parts: The Display Temperature unit of measure Low battery warning C 31 16500 RPM Temperature The display generally shows RPM and temperature. Moreover there are some small icons showing: configured Temperature Unit of Measure (Celsius or Fahrenheit); Temperature Low Battery Warning, that appears when batteries charge status is low. 7

The Keyboard MyChron Light MRT The Keyboard is composed of four push-buttons and is used to switch ON and OFF the system, configure it, recall recorded data and clear the internal memory. The four pushbuttons are used to: ON/VIEW NEXT/MEM CONF / >> MENU / << Switch ON the system and change the page Configure the system Confirm a configuration or switch to the following field (see Configuration functions paragraph) Enter in MENU mode, scroll Configuration menu options (see Configuration functions paragraph) To switch the gauge OFF, please press NEXT/MEM and ON/VIEW buttons at once. Your MyChron Light has also an auto-power off feature that switches it off automatically after 10 minutes of inactivity. 8

The RPM Cable This clip wire is designed to be plugged directly on the spark plug wire and is used for RPM pick up from one-cylinder, 2-4 stroke engines. 9

The Thermocouple All AIM thermocouples are K-Type; AIM can provide you four different kind of sensor (shown in the figure below): 1. H 2 O - Water thermocouple1/8 inches type. 2. H 2 O - Water thermocouple M5 type 3. EGT - Exhaust gas thermocouple 4. CHT - Cylinder head thermocouple Thermocouple from 2 to 4 are provided with an extension cable (length 1.5 m / 45 inches) Thermocouple 1 doesn t need extension cables (Thermocouple length is1.5 m / 59 inches). 10

How to use MyChron Light MRT When you switch MyChron Light MRT ON it shows some information; here they are described in the same order as they appear: 1. AIM 1_xy Firmware version. 2. OK DATA/NO DATA OK DATA: the laptimer has some recorded data in its memory; NO DATA: the memory is empty. 11

Configuration function Before starting, please configure your gauge in order to acquire correct and reliable data. After switch ON, enter in Configuration Mode (push MENU button) to set all required parameters. The parameters that you have to set are here explained. RPM ratio Is the number of spark signals per engine revolution. For example: a two stroke, 1 cylinder engine has ONE spark signal per revolution; a four stroke, one cylinder engine has one spark signal every TWO engine revolutions, etc. To run this function, once entered Configuration MODE, please push MENU button until when you see RPM RATIO Then push CONF button until when you see the desired ratio. Available ratios are: :1, :2, :3, :4, :5, :6 and x 2. :1 is the proper mode for a one cylinder 2 strokes kart. Once the proper ratio chose, please confirm it pushing MENU button. 12

MAXIMUM RPM Temperature unit of measure This function sets the maximum RPM value of your engine. Please note: this parameter has to be set with the maximum accuracy to avoid bad picks of RPM. Set for example 20.000 if your engine reaches 19.500 max. RPM. To set the option, enter Configuration MODE, push MENU button till when you see MAX RPM Then push CONF button to display the set value; use CONF button to scroll digits and NEXT/MEM button to change the value of the blinking digit. Once the proper value set, confirm it, pushing MENU button. This function sets the temperature measure unit; you can chose between Celsius and Fahrenheit. To run this function, please enter Configuration Mode and push MENU button until when you see CENT or FAHR then choose the desired Temperature unit of measure and confirm it pushing MENU button. 13

Other functions MyChron Light MRT Engine working time Clear Data This function computes the total working time of your engine. To run this function, once entered Configuration Mode you see TOT run Then push CONF button to display the total engine working time. This function clears all data stored in the memory of your MyChron Light MRT. To run the option, once entered Configuration Mode, push MENU button until when you see clr data Then push twice NEXT/MEM button to clear data. When the memory has been cleared a confirmation message appears DONE 14

Utility functions Now you are ready to manage the data you have acquired with your gauge. This gauge records lap times absolute maximum values for RPM and temperature for the whole test At the end of each test push NEXT/MEM button to display, one by one, maximum values of RPM and temperature and ON/VIEW button to switch among the pages. 15