Atronic e-motion. Installation Manual

Similar documents
e-motion Installation Module

e-motion Software Module

e-motion / Cashline Progressive Jackpot

Diamond Cabinet Slant Top Users Manual Revision 1.0

Dell MD1280 Storage Enclosure Getting Started Guide

TRC-190 User s Manual

TRC-190 User s Manual

Agilent 70612B K18 Switch Matrix

CASH FEVER Setup and Configuration

icore Kiosk system Installation Guide

PowerLogic High Density Metering System 1-Meter Enclosure

EP/2 Installation Instructions

e-motion Hi(!)bility Parts Catalogue

Line reactors SINAMICS. SINAMICS G120P Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation 4

Removal and Installation8

INSTALLATION MANUAL KIOSK SX6 SF6

User s Manual. ACS550-PD Stock 3R Irrigation Packaged Drive Supplement to ACS550-U1 User s Manual

Hot Link Setup and Configuration

RS3000 SERIES BILL ACCEPTORS

User s Manual. ACS550-PD 3R Irrigation Packaged Drive Supplement to ACS550-U1 User s Manual

Upgrading and Servicing Guide

Dell Networking S4810 Open Networking (ON) Getting Started Guide

Installation Job Aid for VSP 4450GTX-HT- PWR+

Installation Job Aid for VSP 4850GTS

Series Amp Quick Connect Input and Output Power Panels

Upgrading and Servicing Guide

MIC-3001/8. 3U/4U CompactPCI. Enclosure for Rackmounting

Upgrading and Servicing Guide

The power behind competitiveness. Delta Infrasuite Power Management. Power Distribution Unit. User Manual.

Series Amp Pad Mount Quick Connect Input and Output Power Panels

Dell SC460 Expansion Enclosure Getting Started Guide

California Antique Slots, Inc. (805) (FAX)

Upgrading and Servicing Guide

Symmetra PX 160. Maintenance Bypass Enclosure. Installation 05/

Dell SCv3000 and SCv3020 Storage System Getting Started Guide

Liebert MicroPOD 230V

G-MAX TM. ATX Series User s Manual

Dell Storage Center. Getting Started Guide. SCv2000 and SCv2020 Storage System. Regulatory Model: E09J, E10J Regulatory Type: E09J001, E10J001

Liebert XDA Air Flow Enhancer. User Manual

Model HM-535 Power Supply Installation and Service Instructions

LVN5200A-R2, rev. 1, Hardware Installation Guide

Dell SC7020 Storage Controller Getting Started Guide

POWER AVAILABILITY 2U POD USER MANUAL. Power Output Distribution 120 Volt

User Guide CPSMP VAC Power Supply Module: PointSystem CPSMC Accessory CPSMC Accessory. Contents.

Service & Maintenance

Line reactors SINAMICS. SINAMICS G130 Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation

Dell SC5020 and SC5020F Storage Systems Getting Started Guide

Installation Guide. QBox-V6. Standalone/Spare V6 SDI QBox. Standalone/Spare V6 SDI QBox. Part No. A

Operation Manual WARNING. Be sure to read this Operation Manual before use. Universal Space Amusement Equipment Ltd.

Thomas. Change Machine. Operator Guide

FUE 10 FUE-M/S 85A FUE-M/S 86A

High Precision Quad Output DC Power Supply

SCv360 Expansion Enclosure

Dell SCv300 and SCv320 Expansion Enclosure Owner's Manual

Power LED Beam 56 Narrow

Chapter 2: Disassembly

MultiVOIP SIP Gateways

Installation Job Aid for Ethernet Routing Switch 3600 Series

Chemlock PFA and PP Filter Housings

Troubleshooting CHAPTER

Dell OptiPlex All-in-One. Stand Installation Guide

Pro-Star AVW200 Installation and Operation Manual Protel, Inc. ALL RIGHTS RESERVED AVW200HM01.1

TDM To MiniMech conversion ProceDure

Validator Update Instructions for Rowe BC1200 $1 - $20

CUBE Micro Station User Guide

Model 2380 Rack-Mount Kit

Fujitsu Stylistic ST4000 Series TABLET DOCK USER S GUIDE

user manual AMOS-2000 Universal Compact, Chassis System, Supporting Nano-ITX Embedded Boards Revision

Zip12. Charging Desktop Cabinet. User's Guide. Components. Tools Needed ENGLISH. Requires 2 people to remove from box. 6mm. M6 x 35mm Security Screw

POWER AVAILABILITY 2U POD USER MANUAL. Power Output Distribution 230 Volt

System Storage DS3950 Quick Start Guide

LXEM145 SERIES Lanx Australis single Phase KWh Meter 45Amp. User manual

SIMADYN D Digital Control System. Fiber-Optic Rack Coupling CS12. User Manual. Edition DK No

MIC-3001/8. 3U/4U CompactPCI Enclosure for Rack Mounting. User Manual

Serial ATA Hot Swap Drive Cage Upgrade Kit for: Intel Server Chassis SC5200 Intel Server Chassis SC5250-E

Thanks for shopping with Improvements! Lighted Canterbury Christmas Greenery Doorway Arch Item #548443

VLT Line Filter MCC 107 EMC Filter Series VLT Midi Drive FC 280 (K1 K3)

Tiger Box Expansion Chassis Assembly Guide

Installation Job Aid for Ethernet Routing Switch 5900 Series

PRO-1250D CT MID DIN rail three phase four wire energy meter.

HST -S1 Switching element (Translation of Original Manual)

Model 2460-KIT. Screw Terminal Connector Kit. Description / September 2014 *P * 1

MC 11 EB-2 Power supply cabinet with external bus, AC version

FCC COMPLICANCE STATEMENT

This 4200-RM Rack Mount Kit is for installation in 4200-CAB series cabinets only.

HST -M2 Switching element with locking mechanism (Translation of Original Manual)

DOT MATRIX PRINTER SP6000 SERIES

MIC-3002A Series. 3U 6-slot CompactPCI Enclosures with Rear I/O and 6" LCD. User Manual

Documentation KM2042. Sixteen channel digital output module with D-Sub Connector. Version: Date:

Part No. Z , IA Mar OPERATION MANUAL. High Voltage Digitalmeter A

User's Guide. Model High Precision Quad Output DC Power Supply

Installation and Operating instructions for Industrial PC series C61xx

Installing the Cisco ADE 2130 and 2140 Series Appliance Hardware Options

JanusRAID SA-6692J Hardware User Manual

EVO-TM2A EVO-TM2B Touch Screen Monitor

4170 POS System Installation Guide

Dell Inspiron N5110 Service Manual

HST -TZ1 Guard-locking mechanism (Translation of Original Manual)

MDM 011-Z1 Regen Resistor

XPS 13 Convertible Service Manual

Transcription:

Atronic e-motion Installation Manual Rev. 2.3 October 2008

1. Release Info Atronic e-motion Installation Manual Rev. 2.3 October 2008 WARNING! The e-motion / Hi(!)bility manual is intended to provide QUALIFIED TECHNICAL PERSONNEL ONLY with the information necessary to routinely maintain, service, and repair the Atronic e-motion cabinet and components. To avoid personal injury or damage to the equipment, do not perform any serviceing other than that contained in this manual. Copyright Notice: 2003-2008, Atronic. All rights reserved. No part of this publication may be copied or distributed, transmitted, transcribed, stored in a retrieval system, or translated into any human or computer language, in any form or by any means, electronic, mechanical, magnetic, manual, or otherwise, or disclosed to third parties without the express written permission obtained from a properly authorized official of Atronic. DISCLAIMER Atronic makes no representation or warranties, express or implied, with respect to this publication, or any product of Atronic, including but not limited to warranties of merchantability or fitness for any particular purpose. Atronic reserves the right to make changes, enhancements, revisions and alterations of any kind to this publication or the product(s) it covers without obligation to notify any person, institution or organization of such changes, enhancements, revisions and alterations. TRADEMARKS This document may contain trademarks of Atronic. All other brand and product names are trademarks or registered trademarks of their respective companies. 2

Table of Contents 1. Release Info... 2 2. About this Manual... 4 2.1 Scope... 4 2.2 Target Audience... 4 2.3 Included Software Releases... 4 2.4 Related Publications... 5 3. Safety Instructions... 6 4. Machine Components... 8 4.1 Closed Cabinet... 8 4.2 Opened Cabinet... 9 4.3 Logic Box...10 5. Dimensions...11 6. Technical Data...12 7. Machine Installation...13 7.1 Overview...13 7.2 Machine Mounting...14 7.3 Replace Shipping Locks...15 7.4 Prepare Coin Acceptor (CC-16 / MC-16)...16 7.5 Prepare Hopper...16 7.6 Check cables and connectors...16 7.7 Check Commboard Settings...16 7.8 Apply Power...17 8. Basic Setup...18 9. Tests...19 9.1 Test Bill and Coin Handling...19 10. Technical Support Telephone numbers...20 11. Drilling Template...21 3

2. About this Manual 2. About this Manual 2.1 Scope This Installation Manual describes how to install an Atronic e- motion gaming machines. It describes how to mount the machine to a base stand and relevant procedures to be carried out before the machine can be put into operation. Further it contains important safety instructions, technical data and cabinet drawings. 2.2 Target Audience We address qualified technical personnel, who are involved in installation, setup and configuration of Atronic gaming machines. With this user group we assume that they are basically familiar with gaming machines and casino related terminology. Please read this document and the contained safety notes carefully before you start machine installation. 2.3 Included Software Releases The installation procedures described in this manual do not relate to a certain software version. However the graphs included are taken from a C-Level software releases (C5.1.x.x). Other software version may support different features and options. 4

2. About this Manual 2.4 Related Publications More detailed information about Atronic e-motion gaming machines may be found in the following publications: Software Manuals Manual HI Software (B1.2.x STD) Manual HI Software (C4.x.x.x STD) Manual HI Software (C5.x.x.x STD) Operation Manuals Manual EMC HI Operating (B1.2.x STD) Manual EMC HI Operating (C4.x.x.x STD) Manual EMC HI Operating (C5.x.x.x STD) Spare Parts Manual EMC Parts Catalogue Linked Gaming Products Manual [ product ] - Setup and Configuaration for a particular linked gaming product, such as CASH FEVER, King Kong Cash, The Game of Life, Mystery Magic, Hot Link, etc. Peripherals (Coin- and bill acceptors, hopper, printer, etc.) See folder Peripherals on the Atronic Service Manual CD. Note: All mentioned manuals can be found on a CD-ROM titled Atronic Service Manual 2008 or www.atronic.com* If this manual did not came with this CD-ROM, please ask Atronic Technical Service for a free copy of the latest revision. * to gain access an active Gamebook account is necessary. 5

3. Safety Instructions 3. Safety Instructions Note! This installation module of the e-motion Hi(!)bility includes only information relating to the installation of the e-motion cabinet. For other machine or cabinet types please refer to the relevant manuals. Follow the safety instructions below and on the next page, to ensure safe operation. Caution! High Voltage Power cable must be disconnected from the main power socket, so that the machine is free from electrical current. The power switch is intended for service purposes only. Caution! Tipping Hazard The machine must be fastened to an appropriate base, to prevent tipping over. Use the Atronic Installation Station (AIS) for machine mounting. -> see also section 7 Machine Installation Caution! Moving Parts Make sure to disconnect the hopper, when working on it. Caution! Machine Cleaning The machine must not be cleaned using a high pressure cleaner or a vapor jet and must not be installed or operated in areas where high pressure cleaners or vapor jets are used. Use in dry conditions only. Continues on next page 6

3. Safety Instructions Further safety precautions during Installation, Service and Maintenance The machine weight is approx. 120kg. Always use appropiate equipment for transportation. Disconnect the power cable from the socket, before working at the machine. The machine may only be operated in dry conditions and must be connected to a grounded mains power socket. Check that all connectors are seated correctly. False connections can cause irreparable damage, not covered by warranty. For power cable routing remove the knock-out plate on the appropriate side of the cabinet. Edge-protection must be mounted once the knock-out plate has been removed. Only qualified service personnel should perform repairs. Electronic assemblies should only be changed with the power switched off. Use only original Atronic parts for replacement. Atronic commboard and mainboard Danger of explosion if battery is incorrectly replaced! Check for correct polarity and replace with the same or equivalent type only! The machine must not be cleaned using a high pressure cleaner or a vapor jet and must not be installed or operated in areas where high pressure cleaners or vapor jets are used. Use in dry conditions only. Please refer to relevant Atronic service manuals for further instructions on setup, operation and maintenance. 7

4. Machine Components 4. Machine Components 4.1 Closed Cabinet Toplights Speakers Top Glass Online System Module (optional) Framelights Upper Display Main Display Playfield Height Adjustment Button Panel Voucher Printer (optional) Coin Entry Coin Decal Functional Button Panel Mechanical Meters Main Door Lock Jackpot Key Switch Hopper Drawer Coin Bowl Audit Key Switch Hopper Drawer Lock Bill Entry /Bill Acceptor Bill Decal Name Plate Atronic Installation Station (AIS) (Baseplate for mounting) 8

4. Machine Components 4.2 Opened Cabinet Logicbox Top Glass Release Lever Filterboard Power Filterboard Signal Logic Door Logic Door Lock Reset Button Service Button Multimedia Board Cover Maindoor Switch Coin Unit Assembly Coin Acceptor Coin Optics Decal Lighting Door Motor Button Panel Release Lever Bill Acceptor Front Bezel Bill Acceptor Cashbox Power Supply (auxiliary) AC Output Power Switch 9

4. Machine Components 4.3 Logic Box Logicbox Switch Release Lever for Multimediaboard Cover Backplane Commboard Mainboard DVD-ROM Drive Multimediaboard Multimediaboard Cover Graphic Card (VP11) 10

5. Dimensions 5. Dimensions 575-590 610 e-motion Cabinet Weight: approx. 120 Kg / 264 lbs. 135 1055 adjustable 1230-1350 Overall dimensions closed cabinet Height: max. 1350 mm / 53.2 Width: 610 mm / 24 Depth: max. 590 mm / 23.2 905 opened (575 closed) 550 685 (mm) e-motion Cabinet with Topper Weight: approx. 129 Kg / 284 lbs. adjustable 1230 mm - 1350 mm / 48.4-53.2 ~420 mm - 540 mm / 16.5-21.3 1055 mm / 41.5 1643 mm / 64.7 Overall dimensions closed cabinet Height: max. 1643 mm / 64.7 Width: 610 mm / 24 Depth: max. 590 mm / 23.2 575 mm-590 mm/22.6-23.2 550 mm / 21.7 610 mm / 24 11

6. Technical Data 6. Technical Data Electrical Specifications Required Voltage: 100V to 240V AC 50Hz / 60Hz The mains power cable must be pluged into a earthed power outlet labled 8 Amps. Primary Voltage (The power supply features voltage autoswitching) Power Consumption Idle Mode: Payout Mode:approx. approx. 200W 1.8 A / 115V, 0.9 A / 230V 300W 2.6 A / 115V, 1.3 A / 230V Power Supply Secondary Voltage: + 24V / 4A + 12V / 12A - 12V / 0.3A + 5V / 11A + 3.3V / 7A Secondary Voltage Fuses Power Supply: Filterboard F2: Filterboard F3: T 8A / 250V +12V T 6.3A / 250V (UL fuse) +24V T 4A / 250V (UL fuse) Primary Fuses Secondary Fuse Lamps Fluorescent Lamp Button Lighting TL8W/33 300mm, 410 lumen, 4100K (cool white) LED 12V Lamps Environmental specifications Operating Temperature: 0 C - 45 C (32 F - 113 F) Operating Humidity: 0% - 85% (non condensing) (same limits for storage) Suggested Limits 12

7. Machine Installation 7. Machine Installation 7.1 Overview This section should only be carried out by Qualified Technical Service Personnel. Review the list below and perform as needed. Explanations are located on the following pages and in additional manuals. Inspect the machines for transport damage. Any transport damage should be noted and witnessed by the freight forwarder. The manufacturer accepts no responsibility for transport damage. Note: Depending on machine configuration or jurisdictional requirements, additional tasks may have to be carried out before the machine can be put into operation (e.g. acceptance inspection, logicbox sealing, etc.). Check the machines for correct software and hardware configuration. Check that all EPROMs are correctly seated on the boards. Prepare the machine bases by drilling the mounting holes. Use the Atronic drilling template for proper mounting hole placement. Place and mount the machine to the base, using the Atronic Installation Station (AIS). The power cable must be inside the cabinet. Replace shipping locks with casino specific locks. Install and connect accounting system components. Check that all internal and external connections are seated correctly. Prepare coin acceptor and hopper. Apply power to the machine. Load paper into the Printer. Execute basic machine setup (Initial Setup) Configure game. Test bill and coin handling. 13

7. Machine Installation 7.2 Machine Mounting Caution! Tipping Hazard Do not operate the machine unless it has been properly secured with an Atronic Installation Station (AIS). The machine can tip over, if it is not properly mounted. 1. Use the Atronic Installation Station (AIS), supplied by Atronic, to mark the holes on the base before drilling. Make sure to leave min. 180mm (7.1 ) distance to the next machine or a wall on both sides of the cabinet. If no AIS is at hand, use the drilling template on page 21. a b d c 2. Drill four holes 10mm (3/8 ) for the AIS mounting (drillings a) and one out of three holes 10mm (3/8 ) for the machine securing bolt (drillings d) into the base. It is not important which of the 3 holes for the securing bolt is used, if at least one securing bolt is mounted. If the base stand has braces or struttings placed below one mounting hole, simply use another one. 3. Drill or cut out one 55mm (2¼ ) hole for running the main cable into the base (drilling b). 4. Cut out the 60 x 50 mm (3¼ ) recess for coin drop into the base stand (recess c) 5. Secure the AIS to the base using 4 mounting bolts (delivered with the machine) and fasten with wingnuts and washer. Make sure that the boltheads are completely lowered into the counterbores. 14

7. Machine Installation 6. Make sure that the mains power cable is completely inside the machine and that hopper drawer and maindoor are closed and locked. Two forceful persons (one on each side) should lift the machine and then slide it onto the AIS. The baseplate of the machine will grasp into the guides of the AIS. If available, use a lift truck. Caution! The machine weighs 120 kg (264 lbs)! Important: Make sure that the main power cable is completely inside the cabinet and not threaded through the AC hole, before sliding the machine onto the AIS! Otherwise the cable will be damaged! 7. Use at least one securing bolt (delivered with the machine) to secure the machine to the AIS and the base stand. Fix the bolt with wingnut and washer. It is not important which of the 3 holes is used, if at least one securing bolt is mounted. If the base stand has braces or struttings placed below one mounting hole, simply use another one. 7.3 Replace Shipping Locks If not ordered otherwise, Atronic machines are equipped with shipping locks for easy commisioning. These locks have to be replaced by casino specific locks to provide appropriate security. 15

7. Machine Installation 7.4 Prepare Coin Acceptor (CC-16 / MC-16) Slide holder for reference coin rightwards, remove (plastic) transport chip and replace it with appropriate reference coin. Check reference coin for proper (parallel) seating. -> See manuals Peripherals / Coin Acceptor for details. 7.5 Prepare Hopper The hopper high level switch detects the filling level of the hopper by the weight of the coins. If the switch is activated, further accepted coins are separated to the drop box. The switching threshold can be altered with an adjustment srew. Fill the hopper with that amount of coins/tokens at which you want the switch to be activated. Adjust switching threshold with the adjustment screw that operates the high level switch. -> See manuals Peripherals / Hopper for details. 7.6 Check cables and connectors Check that all connectors are seated correctly, prior to first power up. False connections can cause irreparable damage, not covered by warranty. 7.7 Check Commboard Settings The commboard DIP switches and rotary switches configure SAS address, APL address, progressive mode and SAS (dual) channel allocation. Use the DIP switch tables within manual Software / Basic Setup for a particular software version (e.g. C5.1.x) to check or alter the commboard settings. Then connect to the online system components. Commboard Logic Box Cover 16

8. Machine Installation 7.8 Apply Power Punch out one of the perforated knock-out plates in order to provide access for the power cable (figure a). (a) Mount the enclosed edge protection (figure b). Check that the machine mains cable has not been damaged during transit. (b) Check that the supply socket is in good condition and not showing any signs of overheating or damage. Connect the power cable to a grounded power outlet, that is rated for min. 3A / 230V at 50 Hz or 6A / 115V at 60 Hz. Switch the machine on and check that the machine initializes. The LED s on the masterboard (they indicate correct voltages) should all be lit. The power switch is located at the power supply left to the hopper. Power Switch Note: The power up cycle will take some minutes, because the machine checks installed hardware and security relevant circuits. To operate the machine while the maindoor is open, pull the maindoor switch (set it to closed position). At this point the machine installation is finished. Proceed with Basic Setup (Initial Setup and Service Menu settings). Please refer to the software manual for a particular software version for details, e.g. Manual HI Software (C5.x.x.x STD) 17

8. Basic Setup 8. Basic Setup Atronic machines usually come configured as specified during order processing. However it might be necessary to reconfigure basic machine settings, such as denomination, metering, paytable, etc. These settings can not be altered during normal operation, as they require a machine re-initialisation for technical or jurisdictional reasons. Note: Please refer to the document Manual HI Software (version) relevant for a particular software version (e.g. C5.1.x.x) for detailed information. 1. Configure the Commboard This is necessary only, if you have to alter the commboard settings, such as progressive mode or channel allocation. 2. Carry out a RAM Reset (incl. Commboard Clear) This will clear all machine data, statistics and settings, including progressive jackpot configuration. 3. Carry out the Initial Setup After a RAM Reset the machine automatically enters the Initial Setup menu. The Initial Setup allows to configure all basic machine setting. 4. Carry out (Progressive) Jackpot Configuration A PC or notebook with Atronic s Alink Config software is connected to the gaming machine and uploads the progressive jackpot configuration data. Important: It is necessary to carry out the progressive jackpot configuration directly after the Initial Setup. Do not insert credits before the jackpot configuration data is uploaded. In an Atronic Progressive Link (APL) the jackpot configuration has to be carried out at the APL master machine only. The jackpot configuration data is then transferred to all linked APL slave machines. 5. Adjust game settings in the Service Menu 18

10. Tests 9. Tests 9.1 Test Bill and Coin Handling In order to access the Diagnostics menu open maindoor and press the service button at front of the logic box. The Service Menu is displayed. Select file tab Diagnostics. Check coin channeling optics. -> / Coin Handling / Optics Test Check coin diverter. -> / Coin Handling / Coin Diverter Test bill validator acceptance -> / Bill Validator / Validator Test without Stacking Test hopper payout and switching times -> / Hopper / Hopper 1 Note: Make sure to have stacker lock keys and the cashbox keys at your hands, when performing a Validator Test with Stacking. Note: Please refer to the document Manual HI Software (version) relevant for a particular software version (e.g. C5.1.x.x) for detailed information. 19

11. Technical Support 10. Technical Support Telephone numbers Atronic offers and provides technical support 24 hours a day, 7 days a week. If technical assistance is required during normal business hours, please contact your local technical services representative at one of the numbers below. Technical Support Locations: Atronic Germany (International Headquarter) (+49) 5741 24099 950 Atronic Peru (+51) 161 832 00 Atronic United Kingdom (+44) 1727 855 966 Atronic Russia (+7) 495 7377 299 If technical assistance is required outside of normal business hours, please contact one of the Atronic Technical Hotline numbers below. Atronic Technical Hotline numbers: For technical assistance in Europe, South Africa, Asia, Central and South America outside of normal business hours: (+49) 5741 24099 999 20

11. Drilling Template 11. Drilling Template 50 55 541 491 394 270.5 105.5 0 0 41.5 Backside 0 50 e²-motion 50 117.5 60 157 181 Baseplate (AIS) 60 60 Ø 10mm Ø 10mm e-motion&harmony 307.5 550 Cabinet Drilling Template Make sure to leave min. 180mm (7.1 ) distance to the next machine or a wall on both sides of the cabinet. Do not cover the ventilation slots at the backside of the cabinet. 21