H7625A, H7635A Humidity/Temperature Sensors

Similar documents
H7625B; H7635B,C; H7655B Duct-Mount and Outdoor-Mount Humidity/Temperature Sensors

Model HU-224/225. Technical Information TI.224/ Humidity Transduce r FOR ADDITIONAL INFORMATION SEE HU-224/225 DATA SHEET

BACnet Fixed Function Thermostat

N20, N34 Series Non-Spring Return Direct Coupled Actuators

BACnet Fixed Function Thermostat

SmartVFD Frame 8 Wiring Diagrams and Dimensional Drawings

SmartVFD Disconnect Panel Assemblies

CTR21, CTR22, CTR23, and CTR24 Wall Modules

T775S Series 2000 Expansion Module

DWYER INSTRUMENTS, INC. Series AVUL Air Velocity Transmitter. Specifications - Installation and Operating Instructions.

Product Manual SZ2141

CDD Carbon Dioxide Transmitter

CDD4 Duct Carbon Dioxide Transmitter

Product Manual SZ2144

CDD4 Series Room CO2 Transmitter Installation Instructions

T7560A,B,C Digital Wall Module

Compact I/O Module XIO-4AO LON ANALOG OUTPUT MODULE

UNT1100 Series. Binary Output Jumpers AO2 AO1 AO3 AO4 AOCM AOCM AOCM AOCM AO1. AI Switches Job Information N2 Address. Ref N2+ N2- ADDR 0 = ALL OPEN

Installation Guide. Carbon Dioxide (CO 2. ) Detectors. General Information. Mounting WARNING CAUTION. SAE-1011/1012 Space Mount SAE-1011/1012/1062

Greentrol Automation, Inc.

Carbon Monoxide Sensor - ModBus

S7999D SOLA Operator Interface Display

LTEC Heat Pump DDC Controller

TPE 1464 Series Pressure Transducer

Please Read Instruction Carefully Before Installation! Figure 1: A/CO2-DUCT

7800 SERIES S7810B Multi-Drop Switch Module

QS7800A Network Interface ControlBus Module for 7800 SERIES Relay Modules

NEUROLOGIC RESEARCH CORPORATION MODEL 2500

PP-8516 & PP Electronic Static Pressure Controllers and Transmitters for Cental Air Supply Systems General Instructions

T7350 PDA Configuration

HWS Series Wall Mount with Relay Setpoints, LCD, and Humidistat Control

BA/BS4S Temperature Sensor Installation & Operating Instructions

HT Series Wall Mount with Analog Setpoints, LCD, and Humidistat and Thermostat Control

Standard Options. Model 4100 Position Indicating Meter. Three Phase Motor Control. Positran Transmitter

Differential Liquid/Gas Pressure Transmitter

Installation and Operation Instructions I/CO 2, I/CO 2 -VDC, I/CO 2 -T

Temperature controller Ducted systems

PIECAL 520B & 521B Thermocouple Source Operating Instructions

M6410A, M7410F Small Individual Room Controller (IRC) Electric Linear Valve Actuators

T7350 Keypad Configuration

RTT2 ROOM TEMPERATURE SWITCH. Mounting and operating instructions

TOXALERT MODEL AIR 2000

HT Series Wall Mount with Relay Setpoints, LCD, and Humidistat and Thermostat Control

HygroClip M22 Series. 2-wire loop powered humidity temperature transmitters INSTRUCTION MANUAL

Analog Monitor Installation Manual

HCS-3600 / 3602 / 3604 Laboratory Grade & High RFI Immunity Switching Mode Power Supply with Rotary Encoder Control

Wireless General Purpose Adapter (WGA100) Installation Instructions

PIECAL 322 Automated Thermocouple Calibrator Operating Instructions. Product Description. Practical Instrument Electronics

FX-2 Control Board ASY-360-XXX Setup and Configuration Guide

RТTH DUAL ROOM SWITCH

Zone Pressure Touch Sensor - Standard Range

W8735A1013 EnviraCOM Serial Adapter

T7560A1036 Digital Wall Module

RXTP ROOM TEMPERATURE

ETM-2050/ETM-2051 Service Manual

AQ25400B Add-A-Temperature Expansion Control Panel

Sylk I/O Devices APPLICATION FEATURES PRODUCT DATA

Zone Pressure Touch (ZPT) Sensor - Standard Range

Zone Pressure Touch (ZPT) Sensor with Attached Tube (-AT) - Low Pressure Range Unit Installation and Operation Instructions

ON/OFF HUMIDIFIER CONTROL (ROOM 0R DUCT SENSOR) WITH OUTDOOR TEMPERATURE RESET OVERVIEW WALL CONTROLLER INSTALLATION (TCY-BH-T-U)

Tempco Instruction Manual

INSTALLATION INSTRUCTIONS MBPEFY Series Mixing Box for Mitsubishi PEFY Series Units. Before Starting Installation Warning. Installation Instructions

User s Manual. ACS550-PD 3R Irrigation Packaged Drive Supplement to ACS550-U1 User s Manual

USER MANUAL. WBI412F41 AC current transducer

Precision humidity/temperature sensing/control

I/O Modules Quick Selection Guide. Choose From The Most Complete Line Of Input/Output Modules Available

R & D SPECIALTIES SERIES 100 RO CONTROLLER USERS MANUAL. 2004, by R & D Specialties, Inc. All Rights Reserved.

XT-9100 Technical Bulletin

Installation, Start-up and Operating Instructions

System StrainSmart Data Acquisition System. Micro-Measurements FEATURES DESCRIPTION MODEL 5100B SCANNER SPECIFICATIONS

ETM-2040 Service Manual

USER MANUAL. WBV412U01 AC voltage transducer

JADE Economizer Module (MODEL W7220)

Instruction Manual. M Pump Motor Controller. For file reference, please record the following data:

1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882

RST ROOM TEMPERATURE TRANSMITTER. Mounting and operating instructions

PLEASE READ INSTRUCTIONS CAREFULLY BEFORE INSTALLATION!

SLATE. Digital I/O Module INSTALLATION INSTRUCTIONS R8001D4001

Table of Contents. General Information. Document Sure-Aire Flow Monitoring System. User and Service Manual WARNING CAUTION

MYRIAD LC1 LEVEL CONTROLLER INSTRUCTION MANUAL

ControlKeeper 4. General Information. Connecting Relay Loads. Installation Sheet. Getting Started. Power Supply Wiring. Mounting the Cabinet

A0-10 ANALOG OUTPUT. Instruction Manual April 2001 NALOG OUTPUT

Operation Manual MODEL 2TX. 2-wire Isolated ph/orp Transmitter

QS7800B Network Interface ControlBus Module for Multi-Dropping 7800 SERIES Relay Modules

Submittal Data Sheet WAGO Node for itm

USER MANUAL. WBI414F21 AC current transducer

HouseLINK HL-10A Installation and Operation Manual

CONTROL MICROSYSTEMS Thermocouple Analog Input Module. Hardware Manual

Pump-Down Controller MODEL mA Input Scalable 4-20mA Output Duplex Pump Alternation Hand-Off-Auto Controls Dual Run-time Meters

EPWR Series. RoHS. Product Description. Available Products. Installation Instructions 01

RXTH DUAL ROOM SENSOR / SWITCH

N05, N10 SERIES NON-SPRING RETURN DIRECT-COUPLED DAMPER ACTUATORS FOR MODULATING AND FLOATING CONTROL

VC3000 Series Line Voltage Switching Relay Pack Controllers Installation Guide

Installation Instructions

SEZ7656E1045B. Installation Guide for BACnet MS/TP RTU Terminal with IAQ Control CONTENTS

TS InteliSwitch Digital Time Switch 24VDC/VAC

This Datasheet for the IC660BBA026. Block 24/48Vdc Analog Current Source 6 Inputs.

MicroTech II Vertical Self-contained Systems Unit Controller

GF90 Installation, Operation and Troubleshooting Guide

This Datasheet for the IC697CHS790. Rack, 9 Slots, Rear Mount.

Transcription:

H765A, H7635A Humidity/Temperature Sensors WALL-MOUNT MODELS APPLICATION The H765A, H7635A Wall-Mount Humidity/Temperature Sensors are universal Relative Humidity transmitters that can be powered with either a +8 to 36 Vdc or 4 Vac supply. The sensors use a half-wave bridge rectifier to convert AC power to a usable DC voltage. The device also includes a 0K ohm temperature sensor for optional use. The humidity sensors are designed with a field selectable 4 to 0 ma, 0 to 5 Vdc, or 0 to 0 Vdc output signal equivalent to 0 to 00% RH. All units are shipped from the factory with a default setting to accept AC power with three-wire, 0 to 0 Vdc loop-powered output. INSTALLATION When Installing this Product.... Read these instructions carefully. Failure to follow them could damage the product or cause a hazardous condition.. Check ratings given in instructions and on the product to ensure the product is suitable for your application. 3. Installer must be a trained, experienced service technician. 4. After installation is complete, check out product operation as provided in these instructions. INSTALLATION INSTRUCTIONS CAUTION Equipment Damage Hazard. Improper wiring can damage the sensor beyond repair. Follow the wiring instructions carefully. Location Install the device where it cannot be affected by: drafts, or dead spots behind doors and in corners. hot or cold air from ducts. radiant heat from sun or appliances. concealed pipes and chimneys. unheated (uncooled) areas such as an outside wall behind the device. Mounting The housing base mounts over standard in. x 4 in. single gang junction box or flush to the wall:. Install the sensor about 5 ft (.5m) above the floor in an area with good air circulation at average humidity and temperature. (See Fig..). Ensure the device receives adequate airflow. 3. Wire the device. (See Fig. 4 through 3.) 4. Ensure proper DIP switch settings. 5. Apply power to the unit. 6. Snap the cover into position. 7. Turn out the /6 in. allen screws at the bottom of the enclosure until the cover cannot be removed. CAUTION Electrical Shock or Equipment Damage Hazard. Can shock individuals or short equipment circuitry. Disconnect power supply before installation. NO NO YES 5 FEET (.5 METERS) NO M483A Fig.. Typical sensor location. 6-008 3

Output Settings (Table ) The board has three switch blocks: A six DIP switch block. A four DIP switch block. A white gang switch on a blue block.. Adjust the 4-switch block according to Table. NOTE: The 6-switch block normally requires no adjustment. (See the Appendix.). Set the gang switch (white switch in blue block) to correspond with the output (ma or Vdc). NOTE: See Fig. for DIP switch locations. Table. Controller Compatibility and Output Settings. Required 4-Switch Block Blue and Sensor Settings White Controller Output Setting 4 3 Output Switch LONSPEC Setting W7750, W7760, 4-0 ma On 4-0 ma C7600C W776 W7750B,C W7760C, W7753, W7760 T7350, XL50, XL00, XL500 XF Modules, XFL 0-0 Vdc (default) 0-0 Vdc (default) On On Vout H76/3 On On Vout n/a Non-Honeywell 0-5 Vdc On On Vout n/a OFF 0-0 VDC ON NORMAL OPERATION OFF ON OFF ON 4-0 MA OFF ON 0-5 VDC M659A Fig.. DIP switch locations and settings. WIRING For voltage output, shielded cable (6- AWG) should be used. For current output, either shielded cable or twisted pair (6- AWG) can be used. When using shielded cable, ground the shield only at the controller end (see Fig. 3). Grounding both ends can cause a ground loop. NOTE: See Table for terminal designations. Table. Terminal Designations. Terminal Designation ma out Vin (power) 3 GND (common) 4 Vdc (out) 5 0K NTC 6 0K NTC ma OUTPUT TRANSDUCER ONLY Vin + Io 8 TO 36 Vdc POWER SUPPLY CONTROLLER, METER OR RECORDER + INPUT SIGNAL COMMON GROUND M58 Fig. 3. Typical wiring diagram for transducer with twowire ma output with external DC power supply. 6-008 3

T7770 REMOTE SENSOR OUTDOOR AIR SENSOR HEAT RELAY 9 8 7 6 5 4 3 DISCHARGE AIR SENSOR COMPRESSOR CONTACTOR 4 COMPRESSOR CONTACTOR T7350 SUBBASE T5 T6 T7 T4 T3 OS OS AS AS W3/Y4 Y3 W Y HS 5 HC HP M M X RH RC AUX W Y G COMPRESSOR CONTACTOR 3 L L (HOT) Vo Gnd Vin HUMIDITY SENSOR MOTION SENSOR 3 HEAT RELAY FAN RELAY COMPRESSOR CONTACTOR 4 ECONOMIZER 3 4 5 POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED. ENSURE TRANSFORMER IS SIZED TO HANDLE THE LOAD. HEAT/COOL SYSTEMS WITH ONE TRANSFORMER REQUIRE THE FACTORY-INSTALLED JUMPER. USE ECONOMIZER INSTRUCTIONS FOR INSTALLATION DIRECTIONS. HC AND HP PROVIDE 4 VAC TO THE HUMIDITY SENSOR. Fig. 4. Humidity Sensor (0-0 Vdc output) wiring with T7350 (use with RH/Temperature combination T7350 units only). M59 P7640 + PWR COM O OUT P7640 + PWR COM O OUT + Vin Gnd O Vo H76XX + W7760A 3 4 5 6 7 8 9 0 3 4 5 6 E AI AI AI AI AI AI AI AI AI AI AI AI ANALOG AO GND GND 3 4 GND 5 6 GND 7 8 GND OUT GND AO AO OUT OUT OUT OUT OUT OUT OUT OUT 3 4 5 6 7 8 DI DI DI 3 DI GND GND 4 4 4 4 4 4 4 OUT GND E-BUS E-BUS 4 VAC VAC VAC VAC VAC VAC VAC COM VDC COM COM OUT 7 8 9 0 3 4 5 6 7 8 9 L (HOT) L 3 3 33 34 35 36 37 38 39 40 4 4 43 44 M830A POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED. TEMPERATURE SIGNAL CONNECTIONS ARE NOT POLARITY SENSITIVE. Fig. 5. Typical wiring diagram for 5-wire temperature/humidity sensor with Vdc output (used with the XL5A controller). 3 6-008 3

CHECKOUT NOTE: CAUTION Equipment Damage Hazard. Can short electric circuitry. Never connect 0 Vac to the transducer. Connect only DC voltage to a transducer intended for DC supply. Use laboratory quality meters and gauges for applications requiring a high degree of accuracy.. Verify that the transducer is mounted in the correct position.. Verify appropriate input signal and voltage supply. 3. Verify appropriate configuration range. Converting Output Signal to Percent RH 4 to 0mA Signal signal [in ma] 4 ------------------------------------------------ = percent RH 0.6 Example: ma output signal ( - 4)/ 0.6 = 50% RH 0 to 0 Vdc Signal Example: 8 VDC transmitter signal output 8 Vdc/0.0 = 80% RH Table 3. Troubleshooting. Problem Items to Check No reading Verify correct supply voltage at the power terminal blocks. Verify correct wiring configuration and DIP switch settings. Verify that terminal screws are connected tightly with all wires firmly in place. Erratic readings Verify all wires are terminated properly. Ensure that there is no condensation on the board. Verify clean input power. In areas of high RF interference or noise, shielded cable can be necessary to stabilize signal. 6-008 3 4

APPENDIX RH Test and Configuration DIP Switch Settings (Table 4) Only adjust these switches for troubleshooting or recalibrating the sensor. (Adjustment is not normally necessary.) For normal operation, always keep DIP switch 3 in the ON position. When DIP switch 3 is off, the RH transmitter cannot read the sensor. This inability-to-read forces the output to never change. Table 4. Test and Calibration Settings (6-Switch Block). Setting 6 5 4 3 Normal Operation (Default) On 0% RH Output On 50% RH Output On 00% RH Output On Increment RH Output On Decrement RH Output On Reset to Original Calibration On On 0% RH Output (for Testing Only) Transmitter always outputs a signal of 4 ma or 0 Vdc. The sensor does not affect the transmitter output. 50% RH Output (for Testing Only) Transmitter always outputs a signal of ma,.5 VDC, or 5 VDC. The sensor does not affect the transmitter output. 00% RH Output Transmitter always outputs a signal of 0 ma, 5 VDC, or 0 VDC. The sensor does not affect the transmitter output. Sensor doesn t affect the transmitter output. Normal Operating Condition DIP switch 3 must be set in the On position for normal operation. All other DIP switches must be set Off. 5 6-008 3

CALIBRATION All transducers are factory calibrated to meet/exceed published specifications. Field adjustment should not be necessary. Do not verify comparative RH with a sling psychrometer. There are too many variables which induce errors into this process. Recalibration must be done in a controlled environment. Relative humidity must be held stable while making any adjustment. Verify the device output directly with calibrated instrumentation and verify RH with calibrated instrumentation. Never use a controller output. With correct power applied, and only a meter connected to the transducer output, ensure that the output is proportional to the true RH. Using Increment/Decrement Switches Increment RH Output This DIP switch allows you to calibrate the sensor through the software. The switch must be toggled from the Off to the On position and then returned to the Off position for an increase of 0.5% RH. This means that if your humidity has drifted % lower over a certain time period, you will be able to toggle the Increment RH Output switch () times in order to slide the whole curve upward %. Decrement RH Output This DIP switch allows calibration in the same way as the Increment RH. The difference is that each toggle results in a decrease of 0.5% RH. Using Calibration Trim Potentiometers Due to the sensitive nature of humidity calibration, adjusting trimmer potentiometers is not highly recommended. Calibrate only in a stable humidity/temperature chamber of laboratory grade. Single Point Calibration Use only one of the following two options. OPTION. Select a controlled humidity environment between 0 and 40 percent RH. Be sure humidity is stable.. Adjust zero trimmer (z). OPTION. Select a controlled humidity environment between 40 and 70 percent RH. Be sure humidity is stable.. Adjust span trimmer (s). Two Point Calibration. Select a controlled humidity environment between 0 and 40 percent RH. Be sure humidity is stable.. Adjust zero trimmer (z). 3. Select a controlled humidity environment between 70 and 75 percent RH. Be sure humidity is stable. 4. Adjust span trimmer (s). 6-008 3 6

7 6-008 3

LonSpec is a trademark of Echelon Corporation. Automation and Control Solutions Honeywell International Inc. Honeywell Limited-Honeywell Limitée 985 Douglas Drive North 35 Dynamic Drive Golden Valley, MN 554 Scarborough, Ontario MV 4Z9 customer.honeywell.com U.S. Registered Trademark 005 Honeywell International Inc. 6-008 3 B.B. Rev. 0-05 By using this Honeywell literature, you agree that Honeywell will have no liability for any damages arising out of your use or modification to, the literature. You will defend and indemnify Honeywell, its affiliates and subsidiaries, from and against any liability, cost, or damages, including attorneys fees, arising out of, or resulting from, any modification to the literature by you.