Genesys Info Mart. date-time Section

Similar documents
Genesys Info Mart. schedule Section

Basic Device Management

AIMMS Function Reference - Date Time Related Identifiers

Using PEAR Date, converting between time zones in PHP

The Year argument can be one to four digits between 1 and Month is a number representing the month of the year between 1 and 12.

HP Project and Portfolio Management Center

Example. Section: PS 709 Examples of Calculations of Reduced Hours of Work Last Revised: February 2017 Last Reviewed: February 2017 Next Review:

Scheduling. Scheduling Tasks At Creation Time CHAPTER

Class Library java.util Package. Bok, Jong Soon

Enters system mode. Example The following example creates a scheduler named maintenancesched and commits the transaction:

Why Jan 1, 1960? See:

Genesys Info Mart Manager Help. Genesys Info Mart 8.5.0

Programming Date and Time APIs

CALENDAR OF FILING DEADLINES AND SEC HOLIDAYS

Genesys Info Mart. gim-etl-media-chat Section

Eclipse Scheduler and Messaging. Release (Eterm)

Configure System Settings on the FindIT Network Probe

name name C S M E S M E S M E Block S Block M C-Various October Sunday

Calendar Excel Template User Guide

Substitute Quick Reference (SmartFindExpress Substitute Calling System and Web Center)

Date and Time Functions

Assignment: 2. CS 135 Winter 2018 Graham, Nijjar

Solar Eclipse Scheduler. Release 9.0

Package datetimeutils

View a Students Schedule Through Student Services Trigger:

ADVANCED ALGORITHMS TABLE OF CONTENTS

Reporting and Analytics Aggregates 8.1. Deployment Guide

Table of Contents 1 Basic Configuration Commands 1-1

Nortel Enterprise Reporting Quality Monitoring Meta-Model Guide

2016 Calendar of System Events and Moratoriums

If you are also using the Accounting or Financial module, be cautious in editing data in a prior year once the End-of-Year Procedure has been run.

Atomic Time Manager 400 Product Documentation

Calendar PPF Production Cycles Non-Production Activities and Events

Modbus Network Scheduler Configuration Properties

Programming Assignment #2

Schedule/BACnet Schedule

Genesys Info Mart Database Compatibility Reference. Genesys Info Mart Database Compatibility Reference

Part No. P CallPilot. Programming Record

To: All ShoreTel Partners, Enterprise Support Customers and ShoreTel Sales Team Members

Manual Configuration of Time Settings of SG200, SG300, and SG500 Series Switches

Directory Integration

Daylight Savings Times Changes (OS Dependant)

Internet Engineering Task Force (IETF) Category: Standards Track. August 2017

18-642: Time and Date

A. Petr and a calendar

Remotely Test Any Networked Equipment

ENGLISH TYPE 40 OPERATING INSTRUCTIONS

A USER S GUIDE TO THE NPL TELEPHONE TIME SERVICE

Genesys One Routing Applications Guide

San Diego Unified School District Substitute Reference Guide

Python Datetime TZ Documentation

Table of Contents 1 Basic Configuration Commands 1-1

CUCM Versions 8.X/9.X/10.X Time Zone and DST Changes

TaskCentre v4.5 Schedule Tool White Paper

Reporting and Analytics Aggregates 8.1. User s Guide

CPL: A Language for User Control of Internet Telephony Services

DATALINK QUICK START GUIDE - TRAINING SCENARIOS

Service & Support. How do you create a weekly timer with WinCC flexible? WinCC flexible 2008 SP2. FAQ October Answers for industry.

Publication Schedule and Distribution Information

Batch Scheduler. Version: 16.0

WebCalendar User Manual

REV SCHEDULER (iseries)

R ev D. Daylight Saving Time Configuration Guide for an RF Network

ISO8601. Time.ISO8601. Time.ISO8601

fiscalyear Documentation

Auction Calendar 2016/2017 for Capacity Allocation Mechanism Network Code

USER MANUAL. BioPro SA50 Fingerprint & Palm Terminal. Version: 1.0 Date: August Inch TFT Terminal User Manual 1

Module 1.Introduction to Business Objects. Vasundhara Sector 14-A, Plot No , Near Vaishali Metro Station,Ghaziabad

SIMREX Corporation Your Trusted Wireless Solution Provider

Introducing your new ACH ALERT USER GUIDE. Updated

Skybot Scheduler User Guide

A USER'S GUIDE TO THE NPL TELEPHONE TIME SERVICE

Device management commands 1

DDOS-GUARD Q DDoS Attack Report

MBTA Semester Pass Program User Guide

CSC-140 Assignment 6

Table of Contents 1 Basic Configuration Commands 1-1

Systems Programming/ C and UNIX

September 2015 Calendar This Excel calendar is blank & designed for easy use as a planner. Courtesy of WinCalendar.com

Setting Daylight Savings Time (DST) Start and End Times for the Amano MRX-35 Time Clocks

Supported Operating Environment. Java Support

Armstrong State University Engineering Studies MATLAB Marina Switch-Case Statements Primer

Generating Reports CHAPTER. Manual Reports

Real Time Clock Addendum

Simple Java Scripts for Teaching Basic Computer Programming Skills

ICC. BACnet MS/TP Server Driver Manual INDUSTRIAL CONTROL COMMUNICATIONS, INC Industrial Control Communications, Inc.

The Cron service allows you to register STAF commands that will be executed at a specified time interval(s).

Real Time Clock. This appendix contains the information needed to install, program, and operate the Real Time Clock (RTC) option.

ESB Networks Market Release. Meeting of the IGG, 12 th October 2010

Topic 4 Expressions and variables

4D Widgets. 4D Widget components DatePicker SearchPicker TimePicker Alphabetical list of commands - 1 -

[MS-ASTASK]: Exchange ActiveSync: Tasks Class Protocol. Intellectual Property Rights Notice for Open Specifications Documentation

DSC 201: Data Analysis & Visualization

Do not turn to the next page until the start of the exam.

Network Working Group Request for Comments: Columbia University October 2004

Payflow Implementer's Guide FAQs

Data Miner 2 Release Notes Release 18.09

Pandas IV: Time Series

WebEx Integration to Outlook. User Guide

Institute For Arts & Digital Sciences SHORT COURSES

Transcription:

Genesys Info Mart date-time Section 11/27/2017

date-time Section date-time-max-days-ahead date-time-min-days-ahead date-time-start-year date-time-table-name date-time-tz first-day-of-week fiscal-year-start fiscal-year-week-pattern min-days-in-first-week simple-week-numbering Use this configuration section to specify options for populating the DATE_TIME table. To configure a custom calendar, create a similar section that has the same options; name the section by using the date-time- prefix. Job_InitializeGIM populates data in all configured calendars when it initializes the Info Mart database. Job_MaintainGIM subsequently maintains the calendars in accordance with options that are specified in the [datetime] and custom [date-time-*] configuration sections. The maintenance job automatically adjusts for special requirements such as daylight saving time (DST) and fiscal years that do not start on the same day every year (floating fiscal years). Important Consider the settings for the date-time options carefully before the calendar dimension tables are populated for the first time. You can subsequently change the values of the date-time-min-daysahead and date-time-max-days-ahead options at any time. However, changing any of the other date-time options during runtime can introduce inconsistencies into the calendar data and affect reporting results adversely. For example, if you change the timezone option (date-time-tz) after Genesys Info Mart has been initialized, your reports might mix the results for different timezones within the same reporting interval. If you want to change calendar options during runtime, see Changing Calendar Dimensions in the Genesys Info Mart Operations Guide, which provides information about additional steps that are required to maintain reporting consistency. date-time-max-days-ahead Default Value: 366 Valid Values: Any positive integer Genesys Info Mart 2

Specifies, in number of days, how far ahead the calendar dimension table will be populated. The default value specifies that the calendar dimension will be populated up to a year in advance (365 days + 1 day for leap years). Genesys does not recommend that you populate the calendar tables more than a year in advance, in case there are changes to DST or other international time standards that might invalidate the prepopulated data. Note: Ensure that you populate the calendar far enough ahead to meet the requirements of your reporting intervals. date-time-min-days-ahead Default Value: 183 Valid Values: Any positive integer Specifies, in number of days that remain in the prepopulated calendar, when the calendar table will be updated with the next batch of days ahead. The default value specifies that the maintenance job will update this calendar approximately 6 months before it expires. date-time-start-year Default Value: 2012 Valid Values: 1970-2038 Modified: 8.1.1 (in release 8.1.0, the default value was 2010) Specifies the year that the calendar starts. When you are setting this option, ensure that you choose a start year that provides sufficient buffer to prevent inconsistencies or unexpected missing dimensions around the start of the calendar. Genesys recommends that you set the value so that the calendar starts at least one year prior to any date that might be encountered in the data. Be aware that Genesys Info Mart uses GMT for internal time references, and this affects exactly when the calendar starts. For example, if the other [date-time] options that affect the start date are set so that the calendar will start at 00:00 AM on January 1, 2012, and the date-time-tz option is set to Eastern European Time (GMT + 2), the calendar table will be populated with dimensions starting at 02:00 AM on January 1, 2012. date-time-table-name Default Value: DATE_TIME Valid Values: Any string that is a valid table name for your RDBMS Specifies the name of the table in the Info Mart database schema. You must manually modify the script that creates the custom calendar table, to specify this value as the table name. Genesys Info Mart 3

date-time-tz Default Value: GMT Valid Values: Any valid Java time zone Specifies the time zone for the calendar. You can use any valid time zone that is supported by the version of the Java Runtime Environment (JRE) that runs the Genesys Info Mart Server. For more information about supported time zones, see the documentation about calendar time zones on the Java developer website or other public resources.sample public resources: http://www.java2s.com/tutorial/java/0120 Development/GettingallthetimezonesIDs.htm http://en.wikipedia.org/wiki/zone.tab Important Particularly in deployments that use GI2 or the separately installed RAA package, ensure that the time zone is set appropriately for your deployment before you initialize Genesys Info Mart or before aggregation starts. first-day-of-week Default Value: 1 Valid Values: 1-7 (Sunday-Saturday) Specifies the day of the week that is considered to be the start of the week. For example, 1 (Sunday) is usually the first day of the week in the United States; for countries that use the ISO 8601 standard, 2 (Monday) is the first day of the week. Genesys Info Mart 4

fiscal-year-start Default Value: No default value Valid Values: Any valid combination of month and day, in M-d format Dependencies: fiscal-year-week-pattern is set to a valid pattern Introduced: 8.1.1 Specifies the month and day that the fiscal year starts. For example, 1-1 means January 1; 10-1 means October 1. This functionality was introduced in release 8.1.1. If simple-week-numbering=true, every fiscal year starts on the fixed date that is specified by this option. If simple-week-numbering=false, the fiscal year starts on the first day of the week that contains the date that is specified by this option; however, the actual start date depends on the value of the first-day-of-week option. Genesys Info Mart adjusts automatically for the floating fiscal year. For example, if simpleweek-numbering=false, fiscal-year-start=3-1, and first-day-of-week=1, then: Fiscal year 2012 starts on February 26. Fiscal year 2013 starts on February 24. Fiscal year 2014 starts on February 23. fiscal-year-week-pattern Default Value: none Valid Values: none, 544, 454, 445 Specifies the pattern for the number of weeks in each month of a fiscal quarter. For example, 544 means 5 weeks in the first month, 4 weeks in the second month, and 4 weeks in the third month of each quarter. A value of none means that the calendar will not be a fiscal one. Genesys Info Mart 5

min-days-in-first-week Default Value: 1 Valid Values: 1-6 Dependencies: simple-week-numbering=false Specifies the minimum number of days from the new year that must be in the first week of the year, if simple week numbering is not used and there are no partial weeks in the calendar year. The ISO 8601 standard does not use simple week numbering. The ISO 8601 definition of the first week in the year is the week that has the first Thursday in it. To conform to the ISO 8601 standard, set simple-week-numbering=false, first-day-of-week=2, and min-days-in-first-week=4. For example, if simple-week-numbering=false, first-day-of-week=2, and January 1 of the new year is on a Friday, there are 3 days from the new year in the week that starts on Monday, December 28. Therefore: If the value of this option is set to 1, the calendar will count the first week of the new year as starting on Monday, December 28. If the value of this option is set to 4, the week that starts on Monday, December 28, will be assigned to the previous year, and the calendar will count the first week of the new year as starting on Monday, January 4. simple-week-numbering Default Value: true Valid Values: true, false Specifies whether the calendar year and the week-numbering year coincide. For simple week numbering, Week 1 always begins on the first day of the calendar year (for Gregorian calendars, January 1; for fiscal calendars, the day that is specified in the fiscal-year-start option). As a result, the first and last weeks of the year might be partial weeks, because the first week will not necessarily start with the day that is specified by the first-day-of-week option. To comply with ISO 8601 week numbering, set the value of this option to false. Genesys Info Mart 6