Optoelectronics Prisma II Platform Description In optical transmission systems, the network platform forms the foundation of the product family. The Prisma II platform provides network operators with the unique features that enable the deployment of a carrier class -type network. Advanced features such as high usable module density, broad operating temperature range for field deployment without environmental controls, and a unique design optimized for easy module insertion, setup, and administration make the Prisma II platform the key to increased network reliability, scalability, and more cost-effective deployments. Front-Access Chassis 23169 Features High usable module density (up to 13 modules per chassis) Operating temperature range suitable for outdoor field deployment Solid metal construction Low power consumption Superior heat dissipation and air circulation Front access and rear access chassis available Technician-friendly design with easy module insertion and removal, setup, and administration High-speed passive backplane to support migration to digital transmission technologies such as Scientific-Atlanta s bdr Digital Reverse System Excellent fiber, powering, and RF cable management Advanced SNMP-oriented network monitoring and control over multiple network interfaces Multiple connector and powering options User-friendly alarm setup Master / Slave Redundant switching between modules Rear-Access Chassis 23141 Power Supply System 23142 Platform Components The Prisma II platform consists of the following modules/components: Chassis with fan tray (front and rear access) Power Supply System Intelligent Communications Interface Module (ICIM) Module Blanks ICIM 23201
Prisma II Platform Prisma II Chassis Configuration Slots 1 through 16, left to right Slots 1 and 3 are dedicated to power supplies. Slots 2 and 4 can accommodate any single width Application Module (i.e., Optical Amplifier, Transmitter, Receiver, etc.). Slots 5 through 16 can accommodate any Application Module. Intelligent Communications Interface Module (ICIM), if used, must be installed in Slots 15/16. (Note: An ICIM is not required in every chassis.) Blanks required in all unused slots of chassis to maintain proper cooling for all other modules. Prisma II products include the industry s most complete range of high performance optical components. For more information please refer to: 1310 nm Transmitters Prisma II Data Sheet Part Number 739200 1550 nm Transmitters Prisma II Data Sheet Part Number 739201 1550 nm Optical Amplifiers Prisma II Data Sheet Part Number 739202 Receivers Prisma II Data Sheet Part Number 739203 Ancillary Modules Prisma II Data Sheet Part Number 739205 bdr Digital Reverse 2:1 Multiplexing System Prisma II Data Sheet Part Number 744484 2
Optoelectronics Prisma II Chassis Features Rear access; 10.5 (6 RU) high, 13.5 deep Front access; 14.0 (8 RU) high, 11.25 deep 19-inch width with mounts available to fit 23-inch rack Chassis accommodates 16 single-width modules Blind mate (push-on) connectors for RF, power, and data provide complete front access for simplified installation and maintenance Advanced fiber handling system accommodates front or rear fiber routing Optional Intelligent Communications Interface Module (ICIM) for element management Front panel Local Craft Interface (LCI) port for local module configuration Designed for dual, redundant powering via AC or DC power supplies Chassis cooling fans for enhanced air circulation and heat dissipation Extended operating temperature range (-40 C to +65 C) Option for F or BNC connectors Front-Access Chassis Rear-Access Chassis 23169 23141 3
Prisma II Chassis Block Diagram EM In EM Out DB-9 ICIM In ICIM Out DB-9 Clock Input "F" Alarm Out (DB-37) Alarm In (DB-37) RF RF RF RF Data Interface Primary Power Supply Power Input Secondary Power Supply Module 1 Module 2 Module 3 Module N Local Craft Interface (LCI) ICIM Ethernet Port Specifications Electrical Units Notes Connections Transmission Networks Control System (TNCS) with ICIM Two DB-9 or one RJ-45 Local Alarm Two DB-37 male (rear) Auxiliary Power Input One DB-50 female (rear) Ground Stud (Rear) 10-32 thread (rear) Power Consumption with fan tray W DC 48 Bandwidth MHz 5-1000 Environmental Units Notes Temperature Range 1,2 Full Specs and Operational C F -40 to +65-40 to +149 Humidity Range % 0 to 95 3 Mechanical Units Notes Rear Access Front Access Physical Dimensions Depth 13.5 34.3 11.25 28.6 Width 17.5 44.4 17.5 44.4 Height 10.50 26.7 14.0 35.6 Weight lb kg 19.0 8.6 20.0 9.1 Rack Units RU 6 8 Notes: 1. Air temperature measured at the air inlet of the Prisma II chassis. 2. All unused slots in the Prisma II chassis need to be filled with a Module Blank. 3. Recommended for use only in non-condensing environments. 4
Prisma II Chassis Ordering Information Sample P 2 C H R F 2 8 R D D S P 2 C H Platform Power Inlet Type Chassis Product CH Fan Exhaust Rear Exhaust Front Exhaust R F Standard CE (Class II) Power Inlets S E Access Type Rear Access Front Access R F 90 to 265 V AC -48 V DC AA DD Connector Type F Connector BNC Connector F B Quantity of Connectors 28 Connectors 56 Connectors 28 56 Ordering Information Notes Item Options Notes Access Type Rear Access Standard configuration. This selection provides the 6 RU chassis with all connectors on the rear. Front Access Optional configuration. This selection provides the 8 RU chassis with all connectors on the front. Consider this option for back-to-back or Remote Terminal (RT) installations. Connector Type F Connector Standard configuration. BNC Connector Optional configuration. Quantity of Connectors 28 Connectors Standard. This selection provides 2 coaxial connectors per single slot. Optional. This selection provides 4 coaxial connectors per single slot. 56 Connectors Select this option if 4:1 bdr Digital Reverse System products will be installed in the chassis. Fan Exhaust Rear Exhaust Standard configuration. (chassis order code Front Exhaust Optional configuration. Available for back-to-back chassis installations. includes fan tray) Power Inlets 90 265 V AC Universal 90 to 265 V AC powering. -48 V DC -48 V DC powering. Power Inlet Type Standard Select standard for all -48 V DC installations. Standard selection with AC powering provides a 3-prong, Class I AC receptacle suitable for all non-ce requirements. CE (Class II) CE selection with AC powering provides a 2-prong, Class II AC receptacle suitable for all CE requirements. DO NOT select CE for -48V DC powering. 5
Prisma II Chassis Ordering Information (cont d) Optional Spare Equipment and Tools Part Number Module Blank (pk. 6) 716307 Power Supply Blank (pk. 6) 716308 Serial Extension Cable, DB-9 Male to DB-9 Female, 6 ft (1 ea) 180143 TNCS, Cable Kit, Prisma II (1 kit) 738686 Tool, RF Connector Removal, Backplane / Module (1 ea) 741425 Tool, F Connector (security shield) (1 ea) 744313 Test Point Adapter, Long Reach (1 ea) 562580 Fan Tray, Rear Exhaust (1 ea) (Note: chassis order code includes fan tray) 741419 Fan Tray, Front Exhaust (1 ea) (Note: chassis order code includes fan tray) 741420 Fans Only (5 ea) 741421 Power Inlet, Front Access, AC, Standard (1 ea) 744432 Power Inlet, Front Access, DC, Standard (1 ea) 744430 Power Inlet, Front Access, AC, CE (1 ea) 744431 Power Inlet, Rear Access, AC, Standard (1 ea) 741422 Power Inlet, Rear Access, DC, Standard (1 ea) 741424 Power Inlet, Rear Access, AC, CE (1 ea) 741423 Power Connector, -48 VDC (12 ea) 741982 RF Connectors, F, Front or Rear Access, (28 ea) 741429 RF Connectors, BNC, Front or Rear Access, (28 ea) 741428 Mounting Ears, Black (3 pair) 741602 Mounting Ears, Green (3 pair) 741603 Fiber Storage, Rack Mount, 1 RU 739138 6
Optoelectronics Prisma II Power Supply System Features Universal AC (90-265 V AC) and -48 V DC power options Designed to be used in fully-redundant configuration Uninterruptable transfer to single supply in the event that one power supply module fails Modular, front access design and hot-swap capability allow for quick and easy replacement in the event of failure Universal AC voltage input (automatically adjusts to voltage input, for AC supply only) Power factor correction 23142 Power Input T8914 Input Connector EMI Filter Fuse Inrush Current Limiter Rev Input Polarity Prot (DC) Pwr Factor Correction (AC) Isolated DC/DC Converters Output Connector +5VDC -5VDC +24VDC 7
Prisma II Power Supply System Specifications Electrical Units AC -48 V DC Notes Voltage Requirements V 90 to 265, 50/60 Hz -40 to -75 1 Power Consumption A 4.7 full load 9.8 full load Output Voltage/Current V DC/A V DC/A V DC/A +24/10.0 +5/40.0-5/3.0 +24/10.0 +5/40.0-5/3.0 Efficiency (maximum) % 68 68 Line Regulation % 0.5 0.5 Load Regulation % ± 1.5 ± 1.5 Power Stability % ± 0.5 over temperature range ± 0.5 over temperature range Redundancy Switch Time ms 0 0 Environmental Units AC -48 V DC Notes Temperature Range 2 Full Specs and Operational C F -40 to +65-40 to +149-40 to +65-40 to +149 Humidity Range % 0 to 95 0 to 95 3 Mechanical Units Notes Physical Dimensions Depth 9.2 23.4 Width 2.1 5.3 Height 6.4 16.3 Weight lb kg 6.0 2.7 Module Width slots 2 Notes: 1. One module, includes 6 ft. (1.8 m) AC power cord with AC unit. 2. Air temperature measured at the air inlet of the Prisma II chassis. 3. Recommended for use only in non-condensing environments. 8
Prisma II Power Supply System Ordering Information Sample P 2 P S M A S P 2 P S Platform Regulatory Product Standard CE (Class II) S E Power Supply PS Powering Type Modular M 90-265 V AC -48 V DC A D Ordering Information Notes Item Options Notes Powering 90 265 V AC Universal 90 to 265 V AC powering. -48 V DC -48 V DC powering. Regulatory Standard Standard selection provides a power supply suitable for all non-ce requirements. This selection applies to AC and DC power supplies. CE (Class II) CE selection provides a power supply suitable for all CE requirements. This selection applies to AC and DC power supplies. 9
Optoelectronics Prisma II Intelligent Communications Interface Module (ICIM) Features Functions as the interface between the Prisma II modules and the Transmission Networks Control Systems (TNCS) communications bus Provides early warning of systems faults Blind-mate (push-on) connectors for power and data provide complete front access for simplified installation and maintenance Allows local module configuration and status monitoring for up to 140 modules located in multiple chassis Ethernet interface LCD display and keypad TNCS Interface - Remote control and monitoring of individual modules Available in 2 models - Standard - With SNMP and Prisma HDRx compatibility Integrated Communications Interface Module (ICIM) 23201 Prisma II Chassis Backplane Monitoring bus DB9 DB9 Element Manager Interface RS-485 ICIM to Module Interface RS-485 Configuration bus BACKPLANE CONNECTOR DB9 Local Craft Interface RS-232 Microprocessor Hardware Interface Hardware Interface Hardware Interface Hardware Interface RJ-45 Ethernet ICIM Module KEY PAD LCD DISPLAY 10
Prisma II Intelligent Communications Interface Module (ICIM) Specifications Electrical Units Notes Connections RJ-45 (Ethernet) Power Consumption Nominal Operation Heater ON Operation W DC W DC 0.3 13.0 Polling Speed Kb 38.4 Environmental Units Notes Temperature Range 1 Full Specs and Operational C F -40 to +65-40 to +149 Humidity Range % 0 to 95 2 Mechanical Units Notes Physical Dimensions Depth 9.8 24.9 Width 2.1 5.3 Height 7.6 19.3 Weight lb kg 2.0 0.9 Module Width slot 2 Notes: 1. Air temperature measured at the air inlet of the Prisma II chassis. 2. Recommended for use only in non-condensing environments. Ordering Information Description Part Number ICIM: standard 712708 ICIM: standard plus SNMP* and HDRx compatibility 4002258 *Note: This version of SNMP is without traps 11
Optoelectronics Prisma II Module Blanks Description The Prisma II platform is a high-density platform designed for a broad operating temperature range. This feature allows for field deployment without facility environment controls. The thermal integrity of the platform and air circulation around the modules are critical. All unused module slots in a Prisma II chassis must be filled with a Module Blank. Features One module slot wide Two types of blanks available -- Power supply blank (slots 1 and 3) -- Standard blank for all other slots Blanks required in all unused slots of chassis to maintain proper cooling for all other modules Note: Slots 1 and 3 of the Prisma II chassis are dedicated to power supplies. These two slots require the Power Supply Blank. All other slots use the Module Blank. Module Blank 23198 Ordering Information Description Part Number Module Blank (pk. 6) 716307 Power Supply Blank (pk. 6) 716308 Scientific Atlanta, the Scientific-Atlanta logo, and Prisma are registered trademarks of Scientific-Atlanta, Inc. Prisma II and bdr are trademarks of Scientific-Atlanta, Inc. Specifications and product availability are subject to change without notice. 2003 Scientific-Atlanta, Inc. All rights reserved. Scientific-Atlanta, Inc. 1-800-722-2009 or 770-903-6900 www.scientificatlanta.com Part Number 739199 Rev D January 2003 12