FAST ETHERNET: TECHNOLOGIES AND APPLICATIONS

Similar documents
Internetworking is connecting two or more computer networks with some sort of routing device to exchange traffic back and forth, and guide traffic on

A LAN is a high-speed data network that covers a relatively small geographic area. It typically connects workstations, personal computers, printers,

Local Area Network Overview

Chapter 4: Network Access

Concept Questions Demonstrate your knowledge of these concepts by answering the following questions in the space provided.

The following pages contain a guide for the installation

Lecture 05 Chapter 16 High Speed LANs

Performance Evaluation of FDDI, ATM, and Gigabit Ethernet as Backbone Technologies Using Simulation

LAN Systems. Bus topology LANs

10- and 100-Mbps Ethernet

Modern Ethernet. Chapter 6

Introduction to LAN Topologies Cabling. 2000, Cisco Systems, Inc. 3-1

Zarządzanie sieciami telekomunikacyjnymi

FDDI. L26 - Fibre Distributed Data Interface (FDDI) L26 - Fibre Distributed Data Interface (FDDI) FDDI - Fiber Distributed Data Interface

Chapter 10: Local Area Networks

This PDF document is a sample chapter from the book...

Module 5. Broadcast Communication Networks. Version 2 CSE IIT, Kharagpur

More on LANS. LAN Wiring, Interface

Lesson 1: Network Communications

Test Bank for A Guide to Designing and Implementing Local And Wide Area Networks 2nd Edition by Palmer and Sinclair

Data and Computer Communications

Deploying Gigabit Ethernet to the Desktop: Drivers and Applications

IEEE 802 LANs SECTION C

Prof. Shervin Shirmohammadi SITE, University of Ottawa. Design Technologies. Lecture 17: Prof. Shervin Shirmohammadi CEG

Chapter Seven. Local Area Networks: Part 1. Data Communications and Computer Networks: A Business User s Approach Seventh Edition

Integrating Information Systems: Technology, Strategy, and Organizational Factors

Objectives. Hexadecimal Numbering and Addressing. Ethernet / IEEE LAN Technology. Ethernet

Different network topologies

(Network Programming) Basic Networking Hardware

ET4254 Communications and Networking 1

CH : 15 LOCAL AREA NETWORK OVERVIEW

Computer Communications and Network Basics p. 1 Overview of Computer Communications and Networking p. 2 What Does Computer Communications and

Introductory to Computer Networks Local Area Networks. Lecture 16 Fall Isfahan University of technology Dr.

M242 COMPUTER NETWORS AND SECURITY

LAN. CS 4/55231 Internet Engineering. Kent State University Dept. of Computer Science

Introduction to LAN Protocols

Introduction. High Speed LANs. Emergence of High-Speed LANs. Characteristics of High Speed LANS. Text ch. 6, High-Speed Networks and

Chapter 4 NETWORK HARDWARE

Ethernet. Computer Networks. Lecture 4.

Interface The exit interface a packet will take when destined for a specific network.

Chapter 15 Local Area Network Overview

Full file at

Unit 10. Networks. Copyright 2005 Heathkit Company, Inc. All rights reserved.

High Speed LANs. Range of technologies. Fast and Gigabit Ethernet Fibre Channel High Speed Wireless LANs. CS420/520 Axel Krings Page 2

LAN, MAN and WAN. Basics and Comparison. University of Damascus. Computer Engineering Dept. Digital Communications. By Abdulrahman Idlbi

Computer Networks. Lecture 8 Local Area Network, IEEE 802.x

ECE 333: Introduction to Communication Networks Fall Lecture 19: Medium Access Control VII

A+ Guide to Managing & Maintaining Your PC, 8th Edition. Chapter 16 Networking Types, Devices, and Cabling

Introduction to Networks and the Internet

Content. Deterministic Access Polling(1) Master-Slave principles: Introduction Layer 2: Media Access Control

Ch. 4 - WAN, Wide Area Networks

TCP/IP and OSI Model Ethernet LAN Network Cables Network Devices Network Topologies Redundant Internet Connections VLANs Wireless LANs Upcoming

Lecture (07) Media & Switching III Ethernet Protocol & Network Hardware Components

Introduction Computer Networks. Applications Requiring High Speed LANs. Why High Speed LANs? IEEE802.3 Medium Access Control

LAN Protocols. Required reading: Forouzan 13.1 to 13.5 Garcia 6.7, 6.8. CSE 3213, Fall 2015 Instructor: N. Vlajic

Review For Exam 2. Internetworking. Summary Questions. School of Business Eastern Illinois University. School of Business Eastern Illinois University

CCNA Exploration Network Fundamentals. Chapter 09 Ethernet

Data Communication. Chapter # 1: Introduction. By: William Stalling

2. LAN Topologies Gilbert Ndjatou Page 1

Network Media and Layer 1 Functionality

10/100/1000 Mbps Ethernet 100 Mbps FDDI 155/620 Mbps ATM 4/10/45 Mbps Wireless

Prepared by Agha Mohammad Haidari Network Manager ICT Directorate Ministry of Communication & IT

Medium Access Protocols

CCNA Exploration1 Chapter 7: OSI Data Link Layer

KIBABII UNIVERSITY COLLEGE DEPARTMENT COMPUTER SCIENCE & IT ANSWER ALL QUESTIONS IN SECTION A AND ANY TWO QUESTIONS IN SECTION B

Data Link Layer, Part 5. Medium Access Control

Outline: Connecting Many Computers

Goals. Fundamentals of Network Media. More topics. Topics. Multiple access communication. Multiple access solutions

Chapter 8 LAN Topologies

Summary of MAC protocols

Data Link Layer, Part 3 Medium Access Control. Preface

Part3. Local Area Networks (LAN)

Technically Speaking. James Antonakos

Physical Layer V What does the physical layer provide?

Objectives. Learn how computers are connected. Become familiar with different types of transmission media

CHAPTER 2 - NETWORK DEVICES

Introduction to Computer Science (I1100) Networks. Chapter 6

CS610- Computer Network Solved Subjective From Midterm Papers

Introduction to Networking

InfiniBand SDR, DDR, and QDR Technology Guide

Campus Network Design

The NIC is the main interface between the computer and the network cable.

Lecture (04) Data link layer

Internet Architecture and Protocol

Contents. Introduction to Networking. Preface...i. Introduction... xix

Chapter One: Networking Fundamentals Computer Networks

Dr./ Ahmed Mohamed Rabie Sayed

IT 2004 Data Communication & Networking

Ethernet Technologies

Chapter 9. Ethernet. Part II

Local Area Networks (LANs) SMU CSE 5344 /

IEEE standards for local area networks

NETWORKING COMPONENTS

Introduction to Networking Devices

Contention Protocols and Networks

King Fahd University of Petroleum & Minerals Electrical Engineering Department EE 400, Experiment # 2

LAN PROTOCOLS. Beulah A AP/CSE

Come & Join Us at VUSTUDENTS.net

Networking Essentials

Module 1. Introduction. Version 2, CSE IIT, Kharagpur

Transcription:

52-10-26.1 DATA COMMUNICATIONS MANAGEMENT FAST ETHERNET: TECHNOLOGIES AND APPLICATIONS Nathan J. Muller INSIDE 100BaseT Fast Ethernet, Competing Solutions, Fast Ethernet Consortium INTRODUCTION To prevent LANs from becoming the bottleneck in distributed computing environments, higher performance local area networks (LANs) must be devised. Higher bandwidth networking is required to handle the growing number of users, bandwidth-intensive applications, and the demand for sustained network use. Although desktop computers have increased in performance and capabilities, the performance of the LAN to which they are attached has remained the same. Currently, there are several options for solving the bandwidth problem. Among them is a category of technologies called Fast Ethernet. Data center managers face the task of determining when to implement higher bandwidth LANs and which solutions make the most sense for their environment. The conditions that are creating the need for higher bandwidth networking are varied and include the following: Today s LANs share a fixed amount of bandwidth among all attached users. If many users simultaneously are accessing the network, average bandwidth per user declines as more users are added, resulting in unacceptably long delays. With more Pentium-based computers (or their non-intel equiva- PAYOFF IDEA As computing becomes more distributed and accommodates multimedia applications, bandwidth becomes more in demand. Traditional Ethernet and Token Ring LANs have difficulty in meeting the demand for more bandwidth while providing acceptable response times. This article explains the different solutions for meeting the demand for more bandwidth and focuses on one Fast Ethernet solution that currently enjoys widespread acceptance: 100BaseT.

lents) on the network, users can work with extremely large files. With many users contending with other users for network access, moving these large files could take an excessive amount of time. More symmetrical multi-processor (SMP) servers also are on the network to serve the needs of more clients. These servers easily can generate network traffic exceeding the capacity of today s 4, 10, and 16M b/s LANs. Applications such as document imaging, multimedia, video conferencing, computer-aided design/manufacturing (CAD/CAM), automated workflow, and object-oriented RDBMS can generate enormous amounts of network traffic. The requirement for sustained network use is becoming critical, especially for companies that want to provide more employees with access to private intranets for such applications as online analytical processing (OLAP) and decision support systems (DSS). Even telephone calls are being carried over LANs and, from there, over IP nets to other corporate locations. According to one survey, about 20% of the traffic over corporate intranets is voice. 100BASET FAST ETHERNET A number of high-speed LAN technologies are available to address the needs for more bandwidth and improved response times. Among them is 100BaseT, a technology designed to provide a smooth migration from 10BaseT Ethernet the dominant 10M b/s network type in use today to high speed 100M b/s performance. Compatibility 100BaseT Ethernet uses the same contention-based media access control (MAC) method carrier sense multiple access with collision detection (CSMA/CD) that is at the heart of 10BaseT Ethernet. The 100BaseT MAC specification simply reduces the bit time the time it takes for each bit to be transmitted by a factor of ten, providing a 10x boost in speed. The packet format, packet length, error control, and management information in 100BaseT are identical to those in 10BaseT. In the simplest configuration, 100BaseT is a star-wire topology with all stations connected directly to a hub s multiport repeater. The repeater detects collisions. An input signal is repeated on all output links. If two inputs occur at the same time, a jamming signal is sent out on all links. Stations connected to the same multiport repeater are within the same collision domain. Stations separated by a bridge are in different collision domains. The bridge would use two CSMA/CD algorithms, one for each domain.

EXHIBIT 1 10BaseT Etherenet versus 100BaseT Fast Ethernet 10BaseT 100BaseT Speed 10M b/s 100M b/s IEEE Standard 802.3 802.3u Media Access Control CSMA/CD CSMA/CD Topology Bus or star star Cable Support Coaxial, UTP, optical fiber UTP and optical fiber UTP Cable Support Category 3, 4, 5 Category 3, 4, 5 UTP Link Distance (max) 100 meters 100 meters Network Diameter 500 meters 210+ meters Media Independent Yes (via AUI) Yes (via MMI) Full Duplex Capability Yes Yes Notes: AUI, Attachment unit interface; CSMA/CD, Carrier-sense multiple access with collision detection; MMI, Media-independent interface; and UTP, Unshielded twisted pair. Because no protocol translation is required, data can pass between 10BaseT and 100BaseT stations via a hub equipped with an integral 10/100 bridge. Both types of LANs are also full-duplex capable, can be managed from the same SNMP management application, and use the same installed cabling. However, 100BaseT goes beyond 10BaseT in terms of media, offering extensions for optical fiber. 100BaseT also includes the media-independent interface (MII) specification, which is similar to the 10-Mbps attachment unit interface (AUI). The MII provides a single interface, which can support external transceivers for any of the 100BaseT media specifications. Exhibit 1 summarizes the characteristics of 10BaseT Ethernet and 100BaseT Fast Ethernet. Media Choices To ease the migration from 10BaseT to 100BaseT, Fast Ethernet can run over Category 3, 4 or 5 UTP cable, while preserving the critical 100-meter segment length between hubs and end stations. The use of fiber allows more flexibility with regard to distance. For example, the maximum distance from a 100BaseT repeater to a fiber bridge, router, or switch using fiber optic cable is 225 meters (742 feet). The maximum fiber distance between bridges, routers, or switches is 450 meters (1485 feet). The maximum fiber distance between a fiber bridge, router, or switch when the network is configured for half-duplex is 2 kilometers (1.2 miles). By connecting together repeaters and internetworking devices, large, well-structured networks can be created easily with 100BaseT. The types of media used to implement 100BaseT networks is summarized as follows: 100BaseTX: a two-pair system for data grade (Category 5) unshielded twisted-pair (UTP) and STP (shielded twisted-pair) cabling.

EXHIBIT 2 Network Configuration Integrating 10M-b/s and 100M-b/s Ethernet 100BaseT4: a four-pair system for both voice and data grade (Category 3, 4, or 5) UTP cabling. 100BaseFX: a two-strand multi-mode fiber system. Together, the 100BaseTX and 100BaseT4 media specifications cover all cable types currently in use in 10BaseT networks. In addition, all of these cabling systems can be interconnected through a hub. This helps organizations retain their existing cabling infrastructure while migrating to Fast Ethernet, as shown in Exhibit 2. Network Interface Cards Fast Ethernet NICs are available for the client side and the server side of the network. Both have a variety of features that affect price, but the server NICs usually cost more due to dedicated processors and increased

onboard RAM. Server-side NICs will cost $300 or more, while client-side NICs can be found for under $50. Server-side NICs with onboard processors generally have better performance and lower host CPU utilization. Some feature RISC-based microprocessors that run portions of the NIC driver, leaving more CPU cycles for the host. Server NICs should have at least 16 KB of RAM. However, adding more RAM reduces the number of dropped packets, which increases the network s performance. Some server NICs can be equipped with as much as 1GB of RAM. The choice depends on how busy the server is with other processes. Fault tolerance and load balancing are two important considerations when selecting a server-side NIC. A fault-tolerant NIC comes with a failover driver that diverts traffic to another NIC when it becomes disabled. Some vendors have taken fault tolerance one step further, balancing the load across multiple NICs. Server-side NICs and hub modules can be equipped to support a vendor s proprietary features. For example, 3Com Corp. s server-specific Fast Ethernet cards can encapsulate token ring traffic, allowing a Fast Ethernet backbone to carry token ring traffic between stations. Bay Networks offers a Fast Ethernet module for its Multimedia Switch that maps Ethernetbased QoS levels to ATM QoS so that Ethernet end stations can access voice and video already traveling over an ATM backbone. COMPETING SOLUTIONS Throughout the 1980s, network bandwidth was delivered by shared lowspeed LANs typically Ethernet and token ring. Devices such as bridges and routers helped solve bandwidth problems by decreasing the number of users per LAN, a solution known as segmentation. In the 1990s, a richer set of options for solving bandwidth problems has become available. These alternatives include several varieties of Fast Ethernet, each offering 100M b/s. At an average of ten times the speed of today s shared bandwidth LANs, these solutions can eliminate server bottlenecks, handle the needs of bandwidth-intensive applications, and meet the growing need for sustained network utilization. 100BaseVG Another standard for 100M b/s transmission over copper wire is 100BaseVG (voice grade), originally developed by Hewlett-Packard and AT&T. It does away with the MAC Carrier Sense Multiple Access/Collision Detection layer and replaces it with another technique called Demand Priority and a signaling layer that ostensibly makes the network more secure and efficient. Advocates of 100BaseVG note that CSMA/CD originally was designed for a bus topology and had to have the collision-detection mechanism

that today s Ethernet networks provide. However, because most users have moved to 10BaseT, which uses a star topology and hub-based architecture, such collision detection is outdated. Demand Priority accommodates this reality by making the hub a switch instead of a repeater, which makes for a more efficient and secure network. With CSMA/CD, nodes contend for access to the network. Each node listens to the network to determine whether it is idle. Upon sensing that no traffic is currently on the line, the node is free to transmit. When several nodes try to transmit at the same time, a collision results, forcing the nodes to back off and try again at staggered intervals. The more nodes that are connected to the network, the higher the probability that such collisions will occur. 100BaseVG centralizes the management and allocation of network access within the network hub. Unlike the contention-based CSMA/CD method, Demand Priority is deterministic: the 100BaseVG hub serves as a traffic cop, providing equal access to each of the attached nodes. The hub scans each port to test for a transmission request and then grants the request based on priority. Once the hub gives the node access to the network, it is guaranteed a full 100M b/s of bandwidth. 100BaseVG includes two levels of access priority. High priority requests jump ahead of low priority requests. It is the applications and drivers that issue requests for high priority access, based on the type of data queued up to cross the LAN. Advocates of 100BaseVG claim this method reduces overhead at each node and permits greater bandwidth use than CSMA/CD. In addition to replacing CSMA/CD with Demand Priority, 100BaseVG replaces 10BaseT s Manchester coding with 5B/6B coding. Manchester coding requires 20 MHz of bandwidth to send information at a rate of 10M b/s. With 100BaseVG, data and signaling are sent in parallel over all four pairs at rates of 25 MHz each using 5B/6B, which is a more efficient coding scheme. This quadrature (or quartet) signaling entails the use of all four pairs of the wire used for 10BaseT to send and receive data and access signals, whereas 10BaseT uses one pair to transmit and one pair to receive. 100BaseVG runs over any grade of unshielded twisted-pair (UTP) wiring, including Category 3 and Category 5. IBM and HP expanded the 100BaseVG specification to include support for token ring networks as well as Ethernet. The result is 100VG- AnyLAN, which allows Ethernet and token ring packet frames to share the same media. It supports Category 3 unshielded twisted-pair, Type 4, Type 5, and other cable types. However, AnyLAN does not make Ethernet and token-ring networks interoperable it can only unite them physically through the use of common wiring and a common hub. For true interoperability, a router is needed with the capability to merge logically the two protocols into a common packet and addressing scheme.

EXHIBIT 3 ATM Quality of Service (QoS) Parameters Category Constant Bit Rate (CBR) Variable Bit Rate (VBR) Unspecified Bit Rate (UBR) Available Bit Rate (ABR) Application Provides a fixed virtual circuit for applications that require a steady supply of bandwidth, such as voice, video and multimedia traffic. Provides enough bandwidth for bursty traffic such as transaction processing and LAN interconnection, as long as rates do not exceed a specified average. Makes use of any available bandwidth for routine communications between computers, but does not guarantee when or if data will arrive at its destination. Makes use of available bandwidth and minimizes data loss through congestion notification. Applications include E- mail and file transfers. Quality of Service Requirements Delay Variation Guarantee Bandwidth Throughput Guarantee Guarantee Yes Yes Yes No Yes Yes Yes No No No No No Yes No Yes Yes Congestion Feedback Asynchronous Transfer Mode Asynchronous transfer mode (ATM) is a protocol-independent, cellswitching technology that offers high-speed and low-latency for the support of data, voice, and video traffic. Over optical fiber facilities, ATM can support data transmission in the gigabit-per-second range. Most ATM networks in place today operate at 155M b/s to 622M b/s. ATM provides for the automatic and guaranteed assignment of bandwidth to meet the specific needs of applications, making it ideally suited to supporting multimedia applications. ATM is also highly scalable, making it equally suited for interconnecting local area networks and building wide area networks and interconnecting the two environments. ATM serves a broad range of applications very efficiently by allowing an appropriate quality of service (QoS) to be specified for each application. Various categories have been developed to help characterize network traffic, each of which has its own QoS requirements. These categories and QoS requirements are summarized in Exhibit 3. In the mid-1990s, IBM tried to market a 25M-b/s ATM solution that ran over twisted pair wiring. At lower speeds, ATM would allow desktop sys-

tems to have dedicated bandwidth on the network for merging voice, video, and data. However, this proprietary approach never really caught on. It only provided 9M-bps more than 16M-bps token ring and required an investment in infrastructure that would be short-lived once higher speed ATM standards issues were resolved. Fiber Distributed Data Interface At one time, the FDDI was considered the technology best capable of meeting the increasing need for more bandwidth. However, most FDDI installations are backbone networks, not local networks in which each node is directly attached. A key advantage of FDDI is that it consistently averages 95% total bandwidth use under heavy loads, which bodes well for bandwidth-intensive applications. A second fiber optic ring provides fault tolerance for mission-critical applications. Optical fiber offers several advantages over copper-based twisted-pair and coaxial cabling, including: More bandwidth capacity Lower signal attenuation Higher data integrity More immunity to electromagnetic interference and radio frequency interference Higher security Greater durability Longer distances between repeaters Furthermore, optical fiber has great expansion potential over the long term, as demonstrated by a rapidly developing technology called wavelength division multiplexing (WDM). Commercial products are available that provide 40G b/s. Lucent Bell Labs reportedly has demonstrated a multi-terabit system with up to 100 simultaneously operating channels over distances of 400 km. This is enough capacity to carry the entire globe s Internet traffic over a single fiber cable. Copper FDDI Alternatives CDDI. The copper distributed data interface (CDDI) was the result of research by AT&T, Apple, Crescendo, and Fibronics in the early 1990s. It used UTP wiring and was intended as a more economical alternative to optical fiber. The maximum distance between a station and the concentrator was 100 meters (328 ft.). However, because CDDI eliminated the NRZI (non return to zero inverted) encoding of the classical FDDI, it was a proprietary solution. It also required a special management protocol.

SDDI. At approximately the same time, an IBM-led group advocated the shielded twisted pair distributed data interface (SDDI), which allows users to run the FDDI-standard, 100M-b/s transmission speed over shielded twisted-pair wiring at a distance of 100 meters, from station to hub, which is enough to reach the nearest wiring closet on most office floors. SDDI has been promoted as a way to help users make an easy, economical transition to 100M b/s at the workstation in support of bandwidthintensive applications. Its main advantage is that it allows the interconnection of two computers without the need for a concentrator, within the 100-meter limitation. Products based on SDDI are still available from several hub vendors, but they benefit mostly IBM customers with STP wiring in place. TP-PMD. Twisted-pair physical media dependent (TP-PMD) is part of the ANSI X3T9.5 standard that allows for 100M b/s transmission over UTP copper wiring. It replaces the proprietary approaches that had been used previously to run FDDI over copper, including CDDI and SDDI. Interconnect vendors, such as Bay Networks and Cabletron Systems, offer TP- PMD modules that allow single-attached FDDI stations to join the FDDI optical fiber ring supported by the hub chassis. The FDDI stations are connected to the hub via FDDI-standard RJ-45 jacks on the TP-PMD modules. The modules also support TP-PMD over STP cable plants. FAST ETHERNET CONSORTIUM The Fast Ethernet Consortium was formed in December 1993 and is one of several consortiums at the University of New Hampshire InterOperability Lab (IOL). Formed through the cooperative agreement of vendors interested in testing Fast Ethernet products, the Fast Ethernet Consortium performs tests on products and software from both an interoperability and conformance perspective. Each member provides a platform representing their equipment at the IOL for at least 18 months. This allows the users of the lab to perform interoperability testing with current equipment throughout the year, without having to make special legal arrangements with other players in the technology. It also provides consortium members with the ability to test against other s products in a neutral setting without having to incur the capital expense of setting up and operating individual vendor test facilities. Members of the Fast Ethernet Consortium can schedule the lab for testing at any time during the course of their membership on an available basis. Even when a member s equipment is not directly under test it is in a highly metered network in which failures and abnormal behavior can be observed. Members can become involved in special group testing programs at no additional cost. The lab is able to act as an extension of a member company s own R&D/QA organization for the isolation and

resolution of complex problems. Open and widely reviewed testing procedures for both conformance and interoperability can be incorporated into product test plans. The intent of most of the testing programs of the Fast Ethernet Consortium, and of the lab itself, is to isolate problems in member s equipment before it gets into consumers hands. Testing is performed from a quality assurance point of view, not from a marketing or promotions point of view. Therefore, the Consortium agreement limits the disclosure of specific product test results to respective members only. CONCLUSION With 10M-b/s Ethernet rapidly becoming saturated by bandwidth-intensive applications and the need for sustained network use increasing, the time has come to consider higher performance networks. Unlike other high speed technologies, Ethernet has been installed for over 20 years in business, government, and educational networks. The migration to 100M b/s Ethernet is made easier by the compatibility of 10BaseT and 100BaseT technologies, making it unnecessary to alter existing applications for transport at the higher speed. This compatibility allows 10BaseT and 100BaseT segments to be combined in both shared and switched architectures, allowing network administrators to apply the right amount of bandwidth easily, precisely, and cost effectively. Fast Ethernet is managed with the same tools as 10BaseT networks, and no changes to current applications are required to run them over the higher speed 100BaseT network. On the heels of 100BaseT s success, Ethernet is being scaled further, up to 1G b/s over twisted-pair wiring. Nathan Muller is an independent consultant in Huntsville, Alabama who specializes in advanced technology marketing and education. In his 25 years of industry experience, he has written extensively on many aspects of computers and communications, having published 15 books and over 1,500 articles. He has held numerous technical and marketing positions with such companies as Control Data Corporation, Planning Research Corporation, Cable & Wireless Communications, ITT Telecom and General DataComm Inc. He has an M.A. in Social and Organizational Behavior from George Washington University.