Redundancy unit CP-A RU

Similar documents
Power supply CP-C 24/5.0

RTU500 series Data Sheet Power Supply CP-E 24/2.5

Power supply CP-E 48/1.25 Primary switch mode power supply

Power supply CP-E 24/0.75 Primary switch mode power supply

Power supply CP-D 12/2.1 Primary switch mode power supply

Power supply CP-E 24/10.0 Primary switch mode power supply

Redundancy unit CP-D RU Accessory for CP range power supplies (e.g. switch mode power supplies CP-D range)

Messaging module CP-C MM

Power supply CP-C 24/5.0

Voltage monitoring relays CM-ESS.1 For single-phase AC/DC voltages

Buffer module CP-B 24/20.0, ultra-capacitor based Accessory for power supplies (e.g. switch mode power supplies CP range)

Electronic timer CT-SDD.22 Star-delta change-over with 2 n/o contacts

Electronic timer CT-EBD.12 Flasher starting with ON with 1 c/o (SPDT) contact

Switching relay CT-IRE with 1 c/o (SPDT) contact

Electronic timer CT-ARS.11 OFF-delayed without auxiliary voltage with 1 c/o (SPDT) contact

Electronic timer CT-ARS.21 OFF-delayed without auxiliary voltage with 2 c/o (SPDT) contacts

Electronic timer CT-ARE OFF-delayed without auxiliary voltage, 1 c/o (SPDT) contact

Electronic timer CT-APS.21 OFF-delayed with 2 c/o (SPDT) contacts

Electronic timer CT-ARS.11

Electronic timer CT-ERD.12

Electronic timer CT-ERS.12 ON-delayed with 1 c/o (SPDT) contact

Electronic timer CT-AHD.22

Electronic timer CT-ERS.12 ON-delayed with 1 c/o contact Data sheet

Electronic timer CT-ERS.21

Electronic timer CT-SDS.23 Star-delta change-over with 2 n/o contacts

Electronic timer CT-ARS.21 OFF-delayed without auxiliary voltage with 2 c/o (SPDT) contacts

Thermistor motor protection relays CM-MSS.12 and CM-MSS.13

Thermistor motor protection relays CM-MSS.22 and CM-MSS.23

Three-phase monitoring relay

Thermistor motor protection relays CM-MSS.12 and CM-MSS.13

Thermistor motor protection relays CM-MSS.22 and CM-MSS.23

Accessories for pluggable interface relays CR-P Sockets

Thermistor motor protection relays CM-MSS.32 and CM-MSS.33

Thermistor motor protection relay CM-MSS.21

Thermistor motor protection relay CM-MSS.41

Thermistor motor protection relay CM-MSS.11

TRIO-DIODE/12-24DC/2X10/1X20

PHOENIX CONTACT - 07/2006

Thermistor motor protection relays CM-MSS.32 and CM-MSS.33

MINI-PS AC/10-15DC/8

Thermistor motor protection relay CM-MSS.31

PHOENIX CONTACT - 06/2007. DANGER OF EXPLOSION! Remove an item only when it is not connected to power or if it is located in the non-explosive area.

Thermistor motor protection relay CM-MSS.41

QUINT-BUFFER/24DC/24DC/40

Contact protection relay

PHOENIX CONTACT - 08/2009. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

PHOENIX CONTACT - 05/2008. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

Pluggable interface relays CR-P Pcb relays

PHOENIX CONTACT - 05/2008. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

Accessories for pluggable interface relays CR-P, CR-M Pluggable function module

STEP-PS/1AC/24DC/1.75

Power Supply, Primary Switch Mode, Narrow Design MINI-PS AC/24DC/1

Accessories for pluggable interface relays CR-U Pluggable function modules

PHOENIX CONTACT - 01/2007

REDUNDANCY MODULE TSP-REM360 AND TSP-REM600

Rhino Redundancy Module PSM24-REM360S. Operating Instructions

Power Supply, Primary Switch Mode for Universal Use QUINT-PS AC/48DC/5

QUINT-PS-3x AC/24DC/10

Power Supply HARTING pcon

Pluggable interface relays CR-M Miniature relays

PHOENIX CONTACT - 01/2010. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

Rhino PSM Power Supplies. Operating Instructions

Power Supply HARTING pcon

Boxed interface relays and optocouplers R600 Boxed slim relays, optocouplers and accessories

Pluggable interface relays and optocouplers CR-P Pcb relays, optocouplers and accessories

Redundancy Module QUINT-DIODE/40

Switching relay CT-IRS with 1, 2 or 3 c/o contacts Data sheet

AI561 Analog Input Module

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

DC561, digital input/output module,

ABL1RPM24100 regulated SMPS - single phase V input - 24 V output W

TSP-BCM48, TSP-BCM48A. Operating Instruction Manual. Page 1 of 13

UNO-PS/1AC/12DC/30W. Primary-switched power supply unit. Data sheet. 1 Description

CliQ II DC-UPS Module 24V 40A / DRU-24V40ABN

DX561 Digital Input/Output Module

ABL1REM24100 regulated SMPS - single phase V input - 24 V output W

AO523 Analog Input Module

DC562, digital input/output module,

Electronic timer CT-AHS OFF-delayed with 2 c/o contacts Data sheet

DI572 Digital Input Module

AO561 Analog Output Module

RTU511. Binary Output 23BO62. Characteristics. Application. Data Sheet Binary Output 23BO62. The binary output is made via relay contacts.

Output Voltage* (nom.)(adjustable)

ABL1REM24025 regulated SMPS - single phase V input - 24 V output - 60 W

TU531, TU532 Terminal Unit

Industrial Power Supplies

DI561 Digital Input Module

Output Voltage* (nom.)(adjustable)

Electronic timer CT-EAS ON-delayed and OFF-delayed with 1 c/o contact Data sheet

ABL1REM Main. Rated power in W. Power supply output current V. <= 100 Aat 230 V AC. 2.5 Aat 240 V

AX521 Analog Input/Output Module

Part No. Description Product Life Cycle Phase *) unit, 24 VDC, spring terminals. unit, 24 VDC, spring terminals, XC version

ABL4RSM24050 regulated SMPS - 1 or 2 phase V AC - 24 V - 5A

CliQ II Buffer Module 24V 20A / DRB-24V020AB

PMT. Safety Standards. Model Number:

FL MC 2000E (SM40) LC

Industrial Power Supplies

Chrome DIN Rail Power Supply 5V 7.5W 1 Phase (Class II & NEC Class 2) / DRC-5V10W1AZ

TF501, TF521 Terminal Bases

CliQ II Buffer Module 24V 20A / DRB-24V020AB

Transcription:

2CDC 271 010 F0t06 Features Decoupling of CP power supply units with 2 inputs, each up to 20 A per input / channel Output up to 40 A True redundancy by 100 % decoupling of two parallel connected power supplies 2 integrated diodes for the decoupling of 2 switch mode power supplies up to 20 A Control module CP A CM (accessory) is used to monitor both inputs for undervoltage. One of two relay outputs de energizes when undervoltage is sensed at an input. The threshold value is adjustable from 14 to 28 V. The CP A CM plugs onto the front of the CP A RU unit. a OUTPUT ++/ : terminals Output b INPUT +/, +/ : terminals input c Circuit diagram Approvals H UL 508, CAN/CSA C22.2 No.14 A UL 1604 (Class I, Div 2, hazardous locations), CAN/CSA C22.2 No.213 H UL 60950, CAN/CSA C22.2 No. 60950 D GOST K CB scheme Marks a b CE C Tick Order data Approval refers to rated input voltage U in Approval refers to rated input voltage U in Type Description Order code Redundancy unit The CP A RU provides decoupling of two CP power supply units m 40 V and M 5 A. 1SVR 427 071 R0000 Order data Accessories Type Description Order code CP A CM Control module The CP A CM provides monitoring of the input signals of the redundancy unit CP A RU. 1SVR 427 075 R0000 Application The redundancy unit CP A RU provides decoupling of two CP power supply units. It provides automatic redundant power supply operation for critical applications. It has 2 inputs, each up to 20 A, and 1 output up to 40 A. 1

Operating mode Parallel operation, true redundancy with decoupling provided by the CP A RU Redundant circuits are used to increase the operational reliability and eliminate power supply outages. Events that can cause a power supply failure include: incorrect wiring, blown fuses, or failure of a single power supply. If a fault event occurs (called initial fault) in the first power supply circuit, power to all loads is then supplied by the second (redundant) power supply. For this reason, both power supplies must be sized to handle the total current requirement of all loads. The primary and the redundant power supplies are decoupled from one another by the CP A RU unit. It automatically switches from the primary to the redundant supply after a fault. It decouples the output of the failed power supply from the redundant supply preventing the initial fault from shorting or compromising the redundant supplies output. In this way, uninterrupted supply of power to all loads is guaranteed. When available, the two power supplies should be connected to different input voltage phases, to avoid loss of power caused by a blown fuse on the primary side of the power supplies. + - + - INPUT 1 INPUT 2 CP-... < 20 A CP-... < 20 A L N PE OUTPUT L N PE L1 L2 L3 N PE Load 2CDC 272 023 F0208 Decoupling of power supply units with output currents > 20 A L+ L- + - + - INPUT 1 INPUT 2 + - + - INPUT 1 INPUT 2 L+ L- > 20 A > 20 A OUTPUT Load OUTPUT 2CDC 272 027 F0205 Control of input voltages of CP A RU with CP A CM The control module CP A CM indicates the presence of both input voltages of the CP A RU via LEDs and energized output relays. The threshold values for the output relays are adjustable separately per channel from 14 to 28 V. If, by a fault (e.g. failure of a power supply, blown fuse), the voltage in a channel drops below the adjusted threshold value, the corresponding output relay de energizes. The green LEDs IN 1, IN 2 glow, if the corresponding voltage exceeds the adjusted threshold value. The green LED OUT glows, if the output voltage is higher than 3 V. 2

Examples of application with accessories CP A RU with CP A CM for monitoring of two power supplies In case of fault: Fault signal If both relays are de energized, the voltages of both channels are below the adjusted threshold value (e.g. 20 V). This could mean, that both power supply units failed or are switched off, or that there is an overload on the secondary side. Momentary de energization of the relays may be caused by inrush current of a connected load, during starting. If one of the two relays de energizes, this can indicate that the primary power supply unit failed or is switched off, and the redundant power supply is now supplying power to the load. + - + - CP-A CM CP-S / CP-C CP-S / CP-C Relay message channel 1 < 20 V Load Relay message channel 2 < 20 V 2CDC 272 028 F0205 CP A RU with CP A CM for monitoring of one power supply In case of fault: Transfer to an alternative power supply The following example of application shows transferring to an alternative power supply (in this example a battery) after a failure in the primary power supply unit. + - + - CP-A CM CP-S / CP-C Battery L1 N PE L N PE Load 2CDC 272 029 F0205 Installation Mounting The redundancy unit can be snapped on a DIN rail (TH 35-15 or TH 35-7.5 according to IEC/EN 60715) as shown in the accompanying picture. The device is set with its mounting rail slide on the upper edge of the mounting rail and locked by lifting it downwards. 2CDC 272 012 F0b04 3

Installation Demounting Remove the redundancy unit as shown in the accompanying picture. The latching lever is pulled downwards by means of the screwdriver. Then the device can be unhinged from the mounting rail edge and removed. 2CDC 272 013 F0b04 56,5 2.22 (B) (A) (A) Mounting position The devices have to be mounted horizontally with the input terminals on the top. In order to ensure a sufficient convection, the minimum distance to other modules must not be less than (A) 10 mm in horizontal direction and (B) 50 mm in vertical direction. (B) 135.5 5.35 130 5.12 2CDC 272 013 F0b09 Electrical connection Input side [INPUT 1 + / INPUT 2 + ] Connect the input terminals, stripping length of the cable see technical data. For channel 1 left hand input terminals +, for channel 2 right hand input terminals +. Electrical connection Output side [OUTPUT + + ] Rate the lines for the maximum output current or provide a separate fuse protection. We recommend to choose the cable cross section as large as possible in order to minimize voltage drops. Observe the polarity. Connection diagram 2CDC 272 019 F0b05 INPUT 1 +, Connection of the output of power supply unit 1 INPUT 2 +, Connection of the output of power supply unit 2 OUTPUT ++, Output for load 4

Safety instructions and warnings The device must be installed by qualified persons only and in accordance with the specific national regulations (e.g., VDE, etc.). These devices are maintenance-free chassis-mounted units. Disconnect system from supply network! Before any installation, maintenance or modification work: Disconnect the system from the supply network and protect against switching on. Before start of operation: Attention! Improper installation/operation may impair safety and cause operational difficulties or destruction of the unit. Before operation the following must be ensured: Connect to main according to the specific national regulations for class of protection I. Power supply cables and unit must be sufficiently fused and rated. Rate the output lines sufficiently for the output current and connect them with the correct polarity. In order to ensure sufficient air-cooling the distance to other devices has to be considered Screws at the enclosure are for internal grounding. Do not remove them! Do not connect cables! In operation: Do not modify the installation (primary and secondary side)! High current! Risk of electric arcs and electric shock (danger to life)! Risk of burns: Depending on the operation conditions the enclosure can become very hot If the internal fuse blows, most probably the device is defective. In this case, an examination of the switch mode power supply by the manufacturer is necessary. Attention! High voltage! Danger to life! The power supplies contain components with high stored energy and circuits with high voltage! Do not introduce any objects into the unit, and do not open the unit. With some units of this range the output is capable of providing hazardous energy. Ensure that the service personnel is protected against inadvertent contact with parts carrying energy. 5

Technical data Data at T a = 25 C, U in = 230 V AC and rated values, unless otherwise indicated Type CP- A RU Input circuit - Supply circuit (+/ -, +/ -) Rated input voltage U in 24 V DC CP- A RU in combination with CP-A CM Input voltage range per channel 10-28 V DC 13-28 V DC Rated input current I in per channel Maximum input current per channel Transient overvoltage protection 1-20 A 30 A for 300 s Output circuit (++/--) Rated output voltage U out Voltage drop Rated output current I out yes 24 V DC typ. 0.6 V, max. 0.9 V Output ratings per channel T a = 60 C 10-28 V DC / 40 A 13-28 V DC / 40 A 1-40 A T a = 70 C 10-28 V DC / 30 A 13-28 V DC / 30 A Derating 60 C < T a m 70 C 2.5 % per Kelvin temperature increase Peak output current Resistance to reverse feed General data Dimensions (W x H x D) 60 A for 300 s < 40 V 56.5 (60 1) ) x 130 x 137 mm (2.22 (2.36 1) ) x 5.12 x 5.39 in) 0.89 kg (1.96 lb) Weight Minimum distance to other units horizontal / vertical 10 mm / 50 mm (0.39 in / 1.97 in) Degree of protection enclosure / terminals IP20 / IP20 Material of enclosure enclosure shell / cover aluminium / zinc-coated sheet steel Protection class III 2) Mounting DIN rail (IEC/EN 60715) Mounting position horizontal Electrical connection - Input circuit / Output circuit Wire size fine-strand with wire end ferrule 2.5-10 mm 2 (14-8 AWG) fine-strand without wire end ferrule 0.5-10 mm 2 (20-8 AWG) rigid 0.5-16 mm 2 (20-6 AWG) Stripping length 12 mm (0.47 in) Tightening torque 1.2-1.5 Nm Environmental data Ambient temperature range operation -25...+70 C rated load -25...+60 C (without derating) storage -40...+85 C Damp heat (IEC/EN 60068-2-3) 93 % at 40 C, no condensation Climatic category (IEC/EN 60721) 3K3 Vibration (IEC/EN 60068-2-6) Shock (IEC/EN 60068-2-27) Isolation data Insulation voltage between input / output / enclosure 500 V AC (routine test) Pollution degree (EN 50178) 2 Standards Product standard IEC/EN 61204 Low Voltage Directive 2006/95/EG EMC Directive 2004/108/EG 6

Type CP- A RU CP- A RU in combination with CP-A CM RoHS Directive 2002/95/EC Electrical safety EN 50178, EN 60950, UL 60950, UL 508 Electromagnetic compatibility Interference immunity to IEC/EN 61000-6-2 electrostatic discharge IEC/EN 61000-4-2 Level 3 (air discharge w8 kv, contact discharge w6 kv) radiated, radio-frequency, electromagnetic field IEC/EN 61000-4-3 Level 3 (10 V/m) electrical fast transient / burst IEC/EN 61000-4-4 Level 3 (w2 kv) surge IEC/EN 61000-4-5 Level 1 (w0.5 kv) conducted disturbances, induced by radio-frequency fields IEC/EN 61000-4-6 Level 3 (10 V) Interference emission IEC/EN 61000-6-3 high-frequency radiated IEC/CISPR 22 / EN 55022 Class B high-frequency conducted IEC/CISPR 22 / EN 55022 Class B 1) incl. lateral screw 2) This device is designed for connection to a safety extra-low voltage source. If no safety extra-low voltage is used at the input side, the lateral screw can be used for grounding of the enclosure (protection class I). Dimensions in mm Dimensions accessories in mm 54 [2.13 ] 2CDC 272 001 F0b07 56,5 [2.22 ] 24 [0.94 ] 2CDC 272 016 F0b07 CP A CM 7

Further Documentation Document title Document type Document number Electronic Products and Relays Technical catalogue 2CDC 110 004 C020x Power Supply Units Application manual 2CDC 114 048 M0201 Control module CP A CM 2CDC 114 037 D0202 CP-E 12/10.0 2CDC 114 059 D0201 CP-E 24/5.0 2CDC 114 060 D0201 CP-E 24/10.0 2CDC 114 061 D0201 CP-E 24/20.0 2CDC 114 062 D0201 CP-S 24/5.0 2CDC 114 008 D0203 CP-S 24/10.0 2CDC 114 009 D0203 CP-S 24/20.0 2CDC 114 010 D0203 CP-C 24/5.0 2CDC 114 011 D0203 CP-C 24/10.0 2CDC 114 012 D0203 CP-C 24/20.0 2CDC 114 013 D0203 You can find the documentation in the internet under www.abb.com/lowvoltage R Control Products R Power Supplies 8

Contact us STOTZ-KONTAKT GmbH P. O. Box 10 16 80 69006 Heidelberg, Germany Phone: +49 (0) 6221 7 01-0 Fax: +49 (0) 6221 7 01-13 25 E-mail: info.desto@de.abb.com You can find the address of your local sales organisation on the home page http://www.abb.com/contacts -> Low Voltage Products and Systems Document number 2CDC 114 036 D0202 (05/10) Note: We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. AG does not accept any responsibility whatsoever for potential errors or possible lack of information in this document. We reserve all rights in this document and in the subject matter and illustrations contained therein. Any reproduction, disclosure to third parties or utilization of its contents in whole or in parts is forbidden without prior written consent of AG. Copyright 2010 All rights reserved