Automatic Operation: This is the simplest and quickest way to capture a signal, knowing little about what you are measuring.

Similar documents
The uscope Getting started

Fluke 190-Series II Firmware Upgrade V11.46

15. Check this point when you can t communicate

The uscope Getting started

VERUS Navigation Guide

USB Instruments EasyScope II for PS40M10 "Swordfish" Help

TBS2000 Oscilloscope Demo Guide 28 JULY 2016

Quick Start Guide. January EAZ0081L02A Rev. A

Multi-Channel High Speed Data Acquisition Recorder

Capstone Appendix. A guide to your lab computer software

Training Kit for HP 1660/70 Series Logic Analyzers

Using PSpice to Simulate Transmission Lines K. A. Connor Summer 2000 Fields and Waves I

DS2200C User Manual Copyright (c) EasySync Ltd. 2003

Quick Start Guide Agilent Technologies 14565A Device Characterization Software for Windows 98, Windows NT 4.0, Windows 2000 and Windows XP

Step 1. Overview. Goal. System Requirements - 1 x WaveAce passive probe. Setup

Dash HF Family High Speed Data Acquisition Recorder

DSO NANO v3 MANUAL.

Manual imso-204 imso-204l

Component Tests User Manual

SW860 FlukeView Software

QOMO Journey Touch Panel. The QOMO Journey is a touch screen smart panel that you can control with a stylus or with your fingers.

Vision Pointer Tools

Component Tests User Manual

USB Instruments EasyLogger for PS40M10 "Swordfish" Help

Manual imso-204x. RevOrig_

PPALoG. Data Logging Software. Software User Manual

LogicStudio Training Guide

Table of Contents. I.) Introduction 3

AOE 3054 LabView Programming

CONTENTS. Page 1. LIVE VIEWING FOR CAMERAS 3 2. SEARCH FOR FOOTAGE 5 3. BACK UP VIDEO FOOTAGE 7 4. VIEWING BACKUP FOOTAGE 10 FROM A COMPUTER

Thunder Bolt Multi-Tester Operations Manual

99 Washington Street Melrose, MA Phone Toll Free Visit us at

FlukeView. Users Manual. Software for ScopeMeter Test Tools

SBS -600 Graphical Digital Multimeter SBS- 700 Multi-Function Oscilloscope. Quick Start Guide

WaveAce Series Oscilloscopes

There are three windows that are opened. The screen that you will probably spend the most time in is the SCHEMATIC page.

Menu Bars alls you access to your account information and activity.

Remote Control & DVR User Guide

Linear Control Systems LABORATORY

Reference. Menu Overview. Functions Common to Generator (TX) and Analyzer (RX) AC Power. Selecting 115 VAC or 230 VAC Operation

User's Guide. For CarChip and CarChip E/X 8210 & 8220

Tips & Tricks on Ipad

IPTV Middleware Remote Control & DVR User Guide

Remote Control & PVR User Guide Version 12

Quick Reference Guide WaveRunner 6 Zi Oscilloscopes

WebPakCS Software Version 1.0

Configuring RUSHWORKS 3n1 for tracking using the Setup Utility

Equipment location. DMM DM3068UL (Upper Left) Function Generator DG DMM DM3068LR. (Lower Right)

Three-Phase Power Quality Analyzer PowerPad Model 3945

IPTV Middleware Remote Control & DVR User Guide

COGCC GIS Online Map Tools-Intranet Site July 12, 2011

Help Volume Agilent Technologies. All rights reserved. Agilent E2485A Memory Expansion Interface

Introduction to Electronics Workbench

U P C S T U D I O O P E R A T I O N S M A N U A L. Version 1.0 Jan UPC STUDIO OPERATIONS MANUAL Version 1.0 Jan

DENT Instruments ELITEpro Mobile App

DSO Nano Manual. v1.0b

Creating Postcards in Microsoft Publisher

5080/CAL. Users Manual. Calibration Software

Configurator 2.0 Software

Photoshop tutorial: Final Product in Photoshop:

Creating Book Trailers Using Photo Story 3 Why Photo Story 3? It is a free program anyone can download.

WaveAce Oscilloscopes 40 MHz 300 MHz. Debug With Confidence

1 User Guide. 1 Main screen

WIGHTMAN TV Remote Control & DVR User Guide

This is a demonstration of how you can create a Microsoft Power Point presentation:

Adjusting the Display Contrast (Making the Screen Lighter or Darker)

PSM-Mobile User s Manual

HiKE GigaCam. Operation Manual Version th May, Starting the software. Please double click "GigaCam.exe" on screen.

Today s Training Agenda. Network ID not case sensitive No FMAX password. Module Menu Work Management Menu. Description Category Requestor add phase

Quick Reference Guide WaveRunner Xi-A and MXi-A Oscilloscopes

DaqView and ViewXL *327515A-01* DaqView and ViewXL USER S GUIDE. Measurement Computing 10 Commerce Way Norton, MA rev 9.

WaveAce Oscilloscopes 40 MHz 200 MHz. Debug With Confidence

Lite H.264 DVR Setup Guide

Velleman LEGEN HEIRWEG GAVERE BELGIUM. PCS64i PC Scope

The Tracker. How the Tracker Works

Thermal Transient Test Installation and Operating Manual

ELECTRONIC INSTRUMENTATION AND SYSTEMS LABORATORY

Stellaris LM3S3748 Evaluation Kit README FIRST

Logic Analyzers by Link Instruments, Inc Logic Analyzers

Installation & Operation Manual Revision 2

Digital Storage Oscilloscope

Huntron Workstation 4.3 Oscilloscope Tutorial

Ansur Index 2XL. Users Manual. Plug-In

Testing and Debugging

Peregrine Technology CO.,LTD. DSO Oscilloscope. User Menu. V1.1 Date: 2014/07/11

Contents. Remote Control Playback Controls What s on TV? Using the OK Button Using the Info Button... 6

IPTV Middleware Remote Control & DVR User Guide. Version 5.0

Important Note: Not all features described in this guide are available to WCTA customers.

EE 210 Lab Assignment #2: Intro to PSPICE

Spark Nano 3.0. User s Guide WHEN YOU NEED TO KNOW.

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com # # Series Power Analyzer Model 806 Instruction Manual

DLM2000 Series. Mixed Signal Oscilloscope. IM E 3rd Edition

XMReality 6. User Manual for Windows XMReality AB Teknikringen 10, 8 fl SE Linköping Sweden

Digital TV. Quick Reference Guide

EasyScopeIII for DS60M10. User Guide

Dice in Google SketchUp

Standard H.264 DVR Setup Guide

4-20 ma Current Data Logger

A Guide on How to use the Canon Power Shot A 95 Digital Camera

Digital Proximity System Software Installation Manual

Transcription:

Operation of Fluke 199C Oscilloscope: Automatic Operation: This is the simplest and quickest way to capture a signal, knowing little about what you are measuring. A. Turn scope on circular button in lower left hand corner. B. Push the yellow button labeled Scope. C. Press the lime green Auto/Manual button. D. Connect to where you wish to measure. 1. The oscilloscope will auto-range to the correct voltage range, time scale, etc. The trigger will go to Auto Level, and the trigger mode will go to Automatic. 2. Adjustments may be made from that point, such as changing the time scale, voltage scale, readings, using cursors and using screen capture. Use of Screen Replay A. The scope meter will (automatically) capture up to 100 of the most recent scope screens. (This is the case whether triggering for the scope is set to automatic trigger, one shot, or on trigger. Each refresh will result in a screen stored in the memory.) B. To look at what has been saved, press the Replay button. 1. A control panel will appear at the bottom of the screen, allowing you to scroll through each screen one at a time for a close look, scroll back one at a time, or hit play and rapidly go through all of the replay screens. 2. On any recalled screens you may use the cursors and zoom functions to get a better look at the waveform. 3. Individual Screens may be saved to one of the 15 memory positions. C. If any scope adjustments are made (time scale, voltage scale, trigger level, etc), everything previously captured by the replay memory will be lost. Use of the Scope Memory A. Press the light blue hold/run button to freeze the scope screen. The word Hold will appear in a box in the upper right hand side of the scope screen. 1

B. Press the Save/Print button on the lower right had side of the scope control panel. The memory menu will appear across the lower portion of the display. C. Press the F1 button directly below the word Save. A sub-menu will appear. Showing all of the available screen + setup and record + setup positions. D. Using the up and down/left and right arrowed buttons on the scope control panel, highlight the position where you wish to save the screen shot, and then press the F4 button to save the capture in that specific memory position. E. If there was already something in the memory, denoted by the box in front of the memory position being filled in, you will be asked whether you wish to overwrite the data in that memory position. F. To later recall and view what you have stored, press the Save/Print button. The memory menu will appear across the lower portion of the display. G. Press the F2 button below the Recall designation, or the F4 button below the View designation. Downloading Saved Screens to a File or Document A. Connect the scope to your computer via the optical coupler supplied with the scope meter. B. Open Fluke View. The softwear will automatically prompt you about your desire to connect to the Instrument. C. Turn on the Scope Meter. D. Click on the Connect button on the computer screen. E. Once connected, the buttons across the top of the computer screen will light up. F. To download the screen displayed on the Scope Meter into Flukeview, select the button with the picture of a camera on it. The screen will download and appear. G. Alternatively, you may download the Scope Meter capture as a waveform by using the waveform button. H. The screen/file may now be saved as you would any file, but it will have a file extension fvf, making it only viewable with Flukeview. Alternatively, you may copy the graphics via the edit dropdown, and past the picture to another document. 2

Capturing Fencer and Trainer Transients. A. Basic Setup: Scope. 3. Turn scope on circular button in lower left hand corner. 4. Push the yellow button labeled Scope. a. A blue set of options will show up along the bottom the screen b. Push the F1 button to turn reading on and off. Turn them off. c. Push the F4 button for Waveform Options. Another screen will open up. d. On the new screen, push the up and down arrows to alternatively turn Glitch detect on and off. Turn Glitch detect ON e. Use the side arrow to Average. Use the up/down arrows to Turn Average OFF. f. Use the side arrow to move to Waveform. Use the up/down arrows highlight normal, and then press enter (Button F4) to activate Normal. g. Push the circular Clear Menu button to remove the blue menu from the screen. 5. Input to Channel A: a. Push the square A button to turn on the channel A menu. A blue menu will appear at the bottom of the screen. b. Alternately pushing the F1 button will turn input A on and off. Turn input A on. c. Alternately pushing the F2 button will alternate the coupling between DC (direct coupling) and AC. Turn on DC. d. Generally we will be using the 1:1 probe. Pushing the F3 button will open up the probe menu. 1) From the open probe menu, use the up and down arrows to highlight Voltage under probe type. Then pressing the F4 Enter button will select the highlighted voltage probe selection. 2) Pressing the Enter button in step 1) automatically moves you to the Attenuation portion of the menu. Use the up/down arrows to highlight 10:1, and press the F4 enter button to select the 1:1 attenuation. You will then be automatically returned to the main input A menu. e. Press F4 for other Input A Options. Another submenu will be opened. 1) Use the up/down arrows to highlight Normal polarity. Then press the F4 enter button the select Normal. 3

2) You will be automatically be moved to the bandwidth submenu portion of the screen. Use the up/down arrows to highlight Full, and press F4 Enter. This will close out the submenu, and return you to the Input A menu. f. Press the round Clear Menu button to clear the menu. 6. Trigger Menu. a. Press the rectangular Trigger button to open the trigger menu. b. Pressing the F1 button will scroll you through the Edge Trig selections. Highlight A. c. Pressing the F2 button will alternate you between the positive and the negative Slope option. Highlight the left positive slope. d. The trigger level is denoted black mark in the middle of the screen. Use the up/down arrows to adjust. e. Push the F4 button to open the Trigger Options submenu. 1) Use the Up/Down arrows to highlight On Edges selection under trigger options. 2) Pressing the F4 Enter button will make that selection, and automatically bring up the Trigger on Edge submenu. Use the up/down arrows to highlight single shot, and press F4 enter to select single shot. 3) You will be automatically moved over to Noise Rejection Filter submenu. Use the up/down arrows to highlight OFF, press F4 Enter to select, and you will automatically be brought back to the main trigger menu. f. Press the Clear Menu button to clear the trigger menu. 7. Input to Channel B Input. a. Press the square B button. The Input B menu will appear. b. Press the F1 Input B button to alternately turn the B input on and off. Turn it off. c. The rest of the menu and submenus behave the same as for the A input. There is no need to set these unless you would be using the B input. Press the Clear Menu button to clear the trigger menu. d. Press the Clear Menu button to clear the trigger menu. B. Saving the Setup. 1. You only have to go through the above once. This setup can be saved. 2. Press the round Save/Print button to open the save menu. 3. Press F1 to open the Save submenu. 4. Use the up/down arrows to highlight the location (out of 15 choices) where you wish to save the setup. (The active screen goes with it.) 4

5. Press F4 save, and your setup and the screen that was on the scope will be saved in the location you selected. C. Recalling a Setup. 1. Press the round Save/Print button to open the save menu. 2. Press the F2 Recall button. 3. Use the up/down arrows to highlight the location (out of 15 choices) where you saved the setup. 4. Press F2 Recall Setup button to recall you saved setup. 5. You will be automatically be brought to a screen w/ your setup. D. To capture a series of fencer transients. 1. Attach you 1:1 probes to the Input A connector. 2. Turn on the scope. 3. Connect the probe between the two points of the selected cow contact location, preferable at close to (in) the location and w/o other wires attached to the location. 4. You will have to adjust the trigger level, voltage scale, and time scale to capture what you want. a. Start with the voltage scale set to 1 Volt per division, the time scale set at 1 second per division, and the trigger set around a couple of volts. (Use the 1 second per division scale because the fencers generally put out 1 pulse per second, making it easy to identify that what you are capturing is a fencer or trainer transient.) b. If nothing shows up, open the trigger menu by pressing the rectangular Trigger button. 1) Use the up/down arrows to adjust the trigger level until you get something. 2) If you still get nothing, change the voltage scale by pushing the Input A Range button to change the scale to higher or lower values. Note the scale per division changes in the red box on the lower left side of the screen. c. If the screen is overloaded, with signals appearing off screen, change the input scale by pushing the Range button to raise the scale. Raise it until the entire signal appears on the screen. 5. Press the Clear Menu button to clear the trigger menu, once you are satisfied w/ your snapshot. 6. To save the screen, press the Save/Print button, press F1 to open the save menu, use the up/down arrows to highlight the location you wish to save the screen, and press save. Press the Clear Menu button to clear the Save/Print menu. You are now ready to go again. 5

7. Because you are set up for single shot capture, the scope will capture any signal where the trigger level is exceeded. It will then stop, and HOLD will appear in the upper right corner of the screen. If you are satisfied w/ the screen, you can save it as described above. If not, you can adjust your scale and trigger settings, press the rectangular Hold/Run button, and the scope is ready to go again. Regardless, if the Hold signal appears on the screen in the upper right hand corner, you can rearm the scope by pressing the Hold/Run button. E. To look at an individual fencer transient. 1. Once you have captured a series of fencer or trainer transients, you can leave the voltage scale and trigger level alone. 2. The time scale can be adjusted up or down by rocking the rectangular Time button. 3. Change the scale down to a point where you can identify the up and down undulations (like that word?) on the screen which will enable you to determine the Phase duration. On the Fluke 199C, you can change the time scale all the way down to 5 nanoseconds/ division (ns) and still have the glitch detect activated. 8. Once you capture a signal you are happy w/ by alternately pressing the hold/run button and changing the time scale, (and voltage scale as necessary), you can save the screen as previously described. Press the Save/Print button, press F1 to open the save menu, use the up/down arrows to highlight the location you wish to save the screen, and press save. Press the Clear Menu button to clear the Save/Print menu. You are now ready to go again. F. Printing Saved Screens. 1. There are several ways to handle the saved screens to save them to a file and include them in reports. They all start by opening the Flukeview Softwear. 2. Word a. Connect you scopemeter to the computer using the fiberoptic connection cable. b. Recall you saved scope shot on the scopemeter. c. Going to the Program Menu on your computer, you can open up Qreport to automatically open up a Fluke ScopeMeter Test Report blank document. d. In the upper right hand corner is the picture of a camera. Click on the camera, and the computer will automatically connect to the scopemeter connected to the Com Port 1. 6

e. The computer will automatically bring the active screen from the scope, and insert it into the work document. You can then finish filling out the report by inserting the name, etc. You can then save the document as you would any word document. 3. Bringing the saved screen into Flukeview. a. Going to the Program Menu on your computer, you can click on Flukeview to open up the Flukeview softwear. b. If the scope meter was already connected to the Com Port 1, the scope will automatically be connected to Flukeview. Otherwise, you can connect to the scope by clicking on the connection icon in the upper right hand corner of flukeview softwear. c. Clicking on the camera icon will bring in the active scopemeter screen to the Flukeview softwear. Clicking on the camera w/ the question mark will let you bring in screens from the memory locations. d. Once in Flukeview, you may: 1) Save the screens as bitmap or fvf files at a location of your choosing. (FVF files are for Flukeview, and can only be viewed by the softwear. A BMP is better.) 2) You can also transfer the displayed (and highlighted) screen to a word document by first going to the Window Drop Down Menu and highlighting Default Size (to maintain resolution), then click on the Copy the Graphics to the Clipboard icon, (or go to the Edit drop down menu and click on Copy Graphics ), open a Word document, and then pasting the graphics from the clipboard to the word document. You can then add whatever description you wish. 7