OP4510 RT-LAB-RCP/HIL SYSTEMS User Guide.

Similar documents
OP4520 FPGA PROCESSOR AND EXPANSION UNIT User Guide.

OP4510 V2 RT-LAB-RCP/HIL SYSTEM User Guide.

OP8662 High Voltage and Current Probe User Guide.

OP5700 USER MANUAL RCP/HIL/ FPGA-BASED REAL-TIME SIMULATOR.

OP /32 Digital Inputs User Guide.

OP7816 DATASHEET Optically Isolated 16 Digital Inputs Signal Conditioning Module

OP7361 DATASHEET. 8X SFP Carrier.

OP5332 USER GUIDE Isolated Digital to Analog Converter Module

MMC TEST BENCH User Manual

Quick Start Guide for OP4200 Thank you for choosing RT-LAB as your real-time simulation platform.

OP4200 RCP/HIL SYSTEM USER MANUAL.

Quick Start Guide. Thank you for choosing RT-LAB as your real-time simulation platform.

OPAL-RT FIU User Guide.

Integrated Stepper Drive & Motor

SMD Series Integrated Stepper Driver and Motor Revision 1.3

RS-485 Fiber-Optic Link RS-485 to Multi-Mode Fiber-Optic converter ST Fiber Connectors DIN Rail Mount

CM17215HR 100Mb/s Fiber CM17212HR 10/100Mb/s UTP PC/104-Plus Dual Ethernet utilitymodule. User s Manual. BDM Rev. C

SATA II HDD Canister KISS DA 435 Quick Reference Guide

CM17215HR 100Mb/s Fiber CM17212HR 10/100Mb/s UTP PC/104-Plus Dual Ethernet utilitymodule. User s Manual

TRENDnet User s Guide. Cover Page

2.5 inch Solid State Drive (SATA Type) PC-SSD2000S, PC-SSD4000S, PC-SSD8000S User s Guide CONTEC CO.,LTD.

3-4 SAS/SATA II HDD Canister Entry version USER S MANUAL XC-34D1-SA10-0-R. Document number: MAN A

User's Guide. MiniTec TM Series Model MN25 MultiMeter

RESIDENTIAL OPERATOR MOTOR CONTROL BOARD REPLACEMENT INSTRUCTIONS

Proliphix EPA-60 Installation Guide

Enhanced Mini-Chansim Model VCS-232

Installation Operation & Specifications Manual. General Description

The power behind competitiveness. Delta Infrasuite Power Management. Power Distribution Unit. User Manual.

USB Ranger Fiber Optic USB 2.0 Extender. User Guide

AC4G-D User s Manual

P O W E R S U P P L Y M A N U A L

KVM HDMI over IP PoE Extender Kit Operation Manual

FTC-200 X-ray Tube Controller Users Manual

SNT-E RT 10.4 VGA TFT with Touch Screen Display Module Powered By SegeNT embedded GUI Board Hardware Manual

USB Server User Manual

Installation and Operations Manual

EASON TECHNOLOGY. IO8 & IO24 Break-Out Module

Number of input channels

EOS-6000 Series Optical A/B Switch User Manual DC Version

DCS-E 1kW Series, DLM-E 3kW & 4kW Power Supplies

TDM-150 TIMER DISPLAY

Tornado F-5. Motor Backspin Detect Relay And Probe For F-5 Motor Controller

DataPort 250 USB 2.0 Enclosure User s Guide (800)

VIP-812A DUAL NETWORKED STATION PORT

MTS-2000 USER S MANUAL

USB Ranger 422 User Guide

PIM-Mini Pulsed Current Source Operation Manual

User Guide. Control Box. RoscoLED TM.

XC300 VDSL Network Extender Owners Manual

NE1A-SCPU Series. Safety Network Controller. Achieve Safety Control through Programming. Ordering Information. Specifications.

Zonit μats TM Users Guide μats1-lv Version 1.2

NETWORKS DATA CENTER SWITCHES USER MANUAL

USB 2.0 Ranger Port USB m CAT 5e/6/7 Extender System. User Guide

VE8014A/VE8014AR QUAD NETWORKED STATION PORT

User Guide. DMXSM-H18 Splitter. DMXSM-H81 Merger. Document Release Aug Revision B

62533 Ethernet Adapter

16/24 Port 10/100 Auto-Sensing Dual Speed Ethernet Switch

CTI 3570A SERIES INDUSTRIAL ETHERNET SWITCH INSTALLATION AND OPERATION GUIDE Version 1.2

Features various encoder interfaces and controls multiple analog servo drives at high speeds

USB Ranger 110/410 User Guide

COBALT C INSTALLATION GUIDE RFID CONTROLLER ESCORT MEMORY SYSTEMS. High Frequency Passive Radio Frequency Identification Controller

DataPort 350 & 525 USB 2.0 and FireWire Enclosure User s Guide (800)

Name No. of I/O points Model Safety inputs: 12, test outputs: 4

MicroLink Installation Operation & Specifications Manual. General Description

Automated Tuner System Power Distribution Hub

Hybrid AC Driver [GCNC-1110]

HDTVMT User Manual

SATA Hard Drive Enclosure

OPERATOR S MANUAL MODEL DSU-56SA. 56 Kbps Stand Alone CSU/DSU

LBO-H2 Series DIRECT PLUGGABLE LINKBRIDE TM FIBER OPTIC HDMI 2.0 TRANSMISSION SYSTEM

EtherSeries. EtherSeries CR-2. CR-2-Opto. User s Guide. Revised October 7, 2013 Firmware Version 1.X

500 Business Center Drive Pittsburgh, PA USA CAGE 1BGJ7. SwitchMaster R5000 Series Ultra-Compact Ganged A/B Switching System

5 Port Industrial Ethernet Switch. IES5100 Instruction Manual

OP8/16 Optoisolated Digital Input Board User's Manual

RTD Embedded Technologies, Inc.

PSA200 User s Manual

CF15118 CompactFlash Carrier utilitymodules User s Manual

This revision of the manual is dated June, All modifications from previous versions are listed in the appendix.

USB 3.0 Spectra Port USB m Multimode Fiber Extender System. User Guide

EIDX_M Series INSTALLATION GUIDE INTRODUCTION. A Line of Managed Ethernet Switching Hubs

HD-1X4-4K User Manual

SP x4 DVI over Single CAT5 Distribution Amplifier. User Manual. Made in Taiwan

MTP INSTRUCTION MANUAL

S82S (3/7.5-W Models)

TRENDnet User s Guide. Cover Page

Kodiak Mobile INTELLIGENT DOCKING STATION USERS MANUAL PART NUMBER: PANASONIC CF53 TOUGHBOOK COMPATIBLE AN ISO 9001:2008 CERTIFIED COMPANY

PCM-7140 Pulsed Current Source Operation Manual

POWER Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

NETWORKS S2800 & S3900 SERIES SWITCHES USER MANUAL

E2K-F. Flat Capacitive Sensor with a Thickness of Only 10 mm. Flat Proximity Sensor. Ordering Information. Sensors [Refer to Dimensions on page 4.

CiM-25. Quick Start Guide. IP-Enabled M&C Part Number CD/CIM25QSG.IOM Rev. 0

Enclosure TS-530 User Manual

V-9908 MESSAGE/PAGE PANEL

USER MANUAL MODEL 570/ Base-T (CAT-5) Surge Protectors SALES OFFICE (301) TECHNICAL SUPPORT (301)

The Next-generation Sensor Networking Units That Revolutionize the Workplace from Introduction and Startup though Operation. Fiber Units.

CK3W-PD048 CSM_CK3W-PD048_DS_E_DITA_1_2

INTELLIGENT DOCKING STATION USERS MANUAL

Agilent OBSAI Protocol Tester

STATUS Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

XBDM. 1015LV, 1020LV, 1030LV, 1020HV Models USER & INSTALLATION MANUAL BYPASS DISTRIBUTION MODULE

Transcription:

OP4510 RT-LAB-RCP/HIL SYSTEMS User Guide www.opal-rt.com

Published by OPAL-RT Technologies, Inc. 1751 Richardson, suite 2525 Montreal, Quebec, Canada H3K 1G6 www.opal-rt.com 2016 OPAL-RT Technologies, Inc. All rights reserved Printed in Canada

SYMBOL DEFINITIONS The following table lists the symbols used in this document to denote certain conditions: Symbol Definition ATTENTION: Identifies information that requires special consideration TIP: Identifies advice or hints for the user, often in terms of performing a task REFERENCE _ INTERNAL: Identifies an additional source of information within the bookset. CAUTION Indicates a situation which, if not avoided, may result in equipment or work (data) on the system being damaged or lost, or may result in the inability to properly operate the process. Indicates a situation where users must observe precautions for handling electrostatic sensitive devices. CAUTION: Indicates a potentially hazardous situation which, if not avoided, may result in minor or! moderate injury. It may also be used to alert against unsafe practices.! WARNING: Indicates a potentially hazardous situation which, if not avoided, could result in serious injury or death. OP4510 User Guide OPAL-RT Technologies iii

CONTENTS INTRODUCTION... 7 RECEIVING AND VERIFICATION... 8 Standard Hardware...8 SIMULATOR ARCHITECTURE... 9 USER INTERFACE... 10 Front...10 OP4510-1 Rear (standard configuration)...11 OP4510-2 Rear (optional fiber optic configuration)...11 CONNECTING CABLES... 12 Testing I/O Signals...12 DIN and DOUT Loopback Test...12 AIN and AOUT Loopback Test...12 CONNECTING THE GROUND SCREW...13 GENERAL PIN ASSIGNMENTS... 14 SPECIFICATIONS... 15 I/O SPECIFICATIONS... 16 32 Digital In (OP5353)...16 32 Digital Out (OP5360-2)...16 16 Analog In (OP5340)...17 16 Analog Out (OP5330)...17 RS422 Digital In...17 RS422 Digital Out...17 LIMITED WARRANTY... 18 Limited Warranty...18 Return Policy...18 Exclusions...18 Warranty Limitation and Exclusion...19 Disclaimer of Unstated Warranties...19 Limitation of Liability...19 OP4510 User Guide OPAL-RT Technologies 5

6 OPAL-RT Technologies OP4510 User Guide

INTRODUCTION Introduction The OP4510 is a compact device with 128 fast I/O channels with signal conditioning, additional RS422 channels (or optional low-speed fiber optic channels), high-speed communication ports (SFPs), and is fully integrated with Simulink, SimPowerSystem. The integration of high-end INTEL multi-core processors with powerful Kintex 7 FPGA provides greater simulation power and sub-microsecond simulation time steps to maximize accuracy of fast power electronic systems. The OP4510 can simulate power grids with up to 200 nodes. WINDOWS HOST PC SFP 4x 5 Gbits/s OP4510 Ethernet RAM PCI-Express Multicore CPU Solid State Disk LINUX OS KINTEX 7 FPGA Carrier board D/A A/D DO DI DO RS422 DI RS422 RS232 USB 16ch 16ch 32ch 32ch 6ch 6ch Figure 1: OP4510 system architecture (standard configuration) A series of standardized I/O configurations are available with the OP4510, each targeting specific applications. The System Description document provides detailed, specific bitstream information for the application purchased by the customer. OP4510 User Guide OPAL-RT Technologies 7

Introduction Receiving and Verification RECEIVING AND VERIFICATION After opening the package, remove the equipment and components. Make sure that all the items described in Standard Hardware are actually in the box and are undamaged. Standard Hardware The OP4510 real-time simulator includes the following basic hardware: Item Description Part Number OP4510 simulator System Integration binder RT-LAB software CD O/S CD (Redhat) Documentation CD Loopback board Loopback cable N/A C-02B-CAT6 126-0361 113-0737 RJ45 cable (1x) CAT6 (500 MHz) UTP Network Cable - Blue 10FT C-10B-CAT6 Power cable 1.83 m (6 ) power cord, black (10A 125V) CPC06 OPAL-RT strongly recommends the use of anti-static wrist straps whenever handling any electronic device provided by OPAL-RT. Damage resulting from electrostatic charges will not be convered by the manufacturers warranty.! Disconnect power before servicing! The OP4510 may be subjected to EMI when installed in proximity to other devices. Make sure to connect the OP4510 ground to the rack to prevent any EMI related damage to the simulator. 8 OPAL-RT Technologies OP4510 User Guide

Introduction Receiving and Verification SIMULATOR ARCHITECTURE The following image illustrates the simulator s architecture for each option using assembly views of the simulation hardware components within the OP4510 chassis. The OP4510 is an entry-level simulator that contains an FPGA carrier, which can accept four standard OPAL-RT mezzanine boards, in addition to the RS422 signals. Standard RS422 (Optional fiber optic) Type B mezzanines Figure 2: OP4510 Components (back view) The OP4510 can contain any 4 type B mezzanine boards, according to user needs. the standard OP4510-1 contains 2 digital and 2 analog boards (see I/O Specifications for details). These mezzanine boards interface using a DB37 connector at the back of the chassis. Four pairs of DB37F connectors provide up to 32 channels (Channel 00 to 15 and 16 to 31) and DB9 (RS422) connectors each provide an additional six channels. The OP4510 offers two types of synchronization, either LVDS or fiber optic, making it easier to synchronize with any OPAL-RT device. OP4510 User Guide OPAL-RT Technologies 9

Introduction User Interface USER INTERFACE Front A B C D A. Small Form-factor pluggable (SFP) module connectors provide 4 high speed communication links between OPAL-RT FPGAs or between FPGA and user controllers. The SFP use Aurora communication protocol. Use of these ports requires a custom bitstream. B. JTAG connector (for OPAL-RT technicians use only). C. Synchronization connectors status, and user configurable LEDs: LED Label PROG/ CFG OK: RX: TX : USER 1: USER 2: PWR ON: MASTER/SLAVE:. Description CFG OK steady on green and PROG off indicates the FPGA is functioning normally. CFG OK off and PROG steady on yellow indicates the the FPGA has stopped and is no longer functioning. Green when receiving synchronization Green when transmitting synchronization Green LED controlled (configured by user using Simulink blocks) Green LED controlled (configured by user using Simulink blocks) Green indicate OP4510 power is functioning Green indicates MASTER mode, Yellow indicates SLAVE mode. Flashing green and yellow indicates a SAFE bitstream in the FPGA CHASSIS INDEX: 8-pin DIP switch that allows users to set the device s network chassis index. It can be set from 00 to FF (in HEX) for a maximum of 256 addresses. SYNCHRO Label TX/RX TX/RX Description Fiber optic connector. Compatible with OP4500, OP5607, OP7000 and OP7020. Synchronizes time steps between systems and includes high speed FPGA pulses. Stereo jack. Compatible with all OPAL-RT products. 10 OPAL-RT Technologies OP4510 User Guide

D. Target computer monitoring interface. Two push buttons and 6 LED indicators: Name Interface Status Description Power Pushbutton Power on or shut down the Target computer Reset Pushbutton Resets the target computer Power LED Green On indicates that the unit is powered up. HDD LED Green On indicates that the hard disk drive is operating. NIC1 LED Green On indicates that network port 1 is in use. NIC2 LED Green On indicates that network port 2 is in use. Power Fail LED Red On indicates a power fault. Overheat/Fan Fail Red On indicates either that unit has overheated or a fan fault. OP4510-1 Rear (standard configuration) A B A Introduction User Interface C A. DB37 connectors for digital or analog inputs and outputs. B. DB9 connector module for RS422 signals, typically used to transmit differential encoder inputs and outputs. C. Standard computer connectors (left to right): mouse and keyboard, USB ports, monitor, network ports*. *Note that only one network port (the leftmost connector)is required for network connection; use of other connectors is optional. OP4510-2 Rear (optional fiber optic configuration) A C A. Fiber optic connector module, providing 6RX and 6 TX channels. Each RxTx pair use Avago AFBR-2624Z (RX) and AFBR-1624Z (TX) These channels can be used as digital I/Os or for low-speed communication protocols. The ORION protocol, developped by OPAL-RT, is compatible with these channels and available in custom bitstreams. OP4510 User Guide OPAL-RT Technologies 11

Connecting Cables User Interface CONNECTING CABLES These are the basic cabling instructions for your OP4510. Use the cables provided to connect your devices, as instructed. 1. Connect power cord to unit and to appropriate power source (outlet). 2. Connect DB37 cables from OP4510 to external devices (motor, controller, etc.). Before connecting cables, make sure that amplitude are compatible with OPAL-RT DB37 amplitudes (see Specifications). 3. Connect DB9 cables (for RS422 signals) from OP4510 to external devices. You are now ready to power up your OP4510. Make sure that all cables are properly connected before powering up. Testing I/O Signals Before using your OP4510, it is good practice to test signals using the loopback board provided with the integration kit and RT-LAB, which lets you read any feedback from outputs to inputs. DIN and DOUT Loopback Test 1. Connect the loopback board to a Dout DB37 connector and connect the cable to a Din DB37 connector. 2. Connect the loopback board s Vuser to a power source 3. Observe the Dout feedback on the Din using the integration model provided. AIN and AOUT Loopback Test 1. Connect the loopback board to an Aout DB37 connector and connect the cable to a Ain DB37 connector. 2. Observe the Aout feedback on the Ain using the integration model provided. 12 OPAL-RT Technologies OP4510 User Guide

CONNECTING THE GROUND SCREW Connecting Cables User Interface You must connect a grounding cable from the OP4510 ground screw to the rack to ensure that the OP4510 terminates securely in a ground. Proper grounding will help prevent electric shocks, protect the OP5600 from voltage spikes (from a variety of causes, including lightening strikes), and provide increased immunity from EMI by lowering noise levels and emissions. 1. Select a flat braided grounding strap of adequate length (as short as possible provides best protection), with ring terminals on each end. 2. Attach one ring terminal to the ground screw on the OP4510 (shown in Figure 4) 3. Attach the other ring terminal to the rack using a nut and lockwasher. A Figure 4: Connecting ground screw C OP4510 User Guide OPAL-RT Technologies 13

general Pin Assignments User Interface GENERAL PIN ASSIGNMENTS The following tables provide the generic pin assignments for the OP4510 s DB37 and DB9 connectors. More detailed information, tailored to specific firmware, can be found in the Integration documents provided with your order. DB37 pin Channel pin assignment DB37 Channel pin assignment 1 + 00 20-00 2 + 01 21-01 3 + 02 22-02 4 + 03 23-03 5 + 04 24-04 6 + 05 25-05 7 + 06 26-06 7 + 07 27-07 9 + 08 28-08 10 + 09 29-09 11 + 10 30-10 12 + 11 31-11 13 + 12 32-12 14 + 13 33-13 15 + 14 34-14 16 + 15 35-15 17 +12V* 36 DGND 18 Vuser 37 Vrtn 19 * Non-isolated, limited to 400mA 00+ 01+ 02+ 03+ 04+ 05+ 06+ 07+ 08+ 09+ 10+ 11+ 12+ 13+ 14+ 15+ 12V Vuser 1 19 20 37-00 - 01-02 - 03-04 - 05-06 - 07-08 - 09-10 - 11-12 - 13-14 - 15 DGND Vrtn DB9F Pin RS422 OUT CH 00-02 DB9F Pin RS422 IN CH00-02 1 TX0+ 1 RX0+ 2 TX1+ 2 RX1+ 3 TX2+ 3 RX2+ 4 N.C 4 N.C 5 +12V limited * 5 +12V limited * 6 TX0-6 RX0-7 TX1-7 RX1-8 TX2-8 RX2-9 DGND 9 DGND DB9F Pin RS422 OUT CH 03-05 DB9F Pin RS422 IN CH03-05 1 TX3+ 1 RX3+ 2 TX4+ 2 RX4+ 3 TX5+ 3 RX5+ 4 N.C 4 N.C 5 +12V limited * 5 +12V limited * 6 TX3-6 RX3-7 TX4-7 RX4-8 TX5-8 RX5-9 DGND 9 DGND DOUT RS422 DIN RS422 CH 00-02 CH 00-02 CH 03-05 CH 03-05 *Same 12V for all the connectors. 400mA total 14 OPAL-RT Technologies OP4510 User Guide

SPECIFICATIONS Specifications User Interface Product name FPGA Computer I/O connectors I/O module mezzanines 4 High speed communication port PC interface Power supply voltage range Frequency OP4510 RT-LAB-RCP/HIL SYSTEM OP4510-1, Standard RS422 OP4510-2, optional fiber optic Kintex-7 FPGA, 325T, 326,080 logic cells, 840 DSP slice (Multiplier- adder) 8GB RAM. Xeon E3 4 core CPU, 3.2 GHz, solid state hard disk 128 GB OP4510-1 (standard) DB37F DB9 (RS422, 25 MHz) 4 SFP, 1 to 5 Gbits/s optical cable pairs (Rx/Tx) OP4510-2 (optional) DB37 Avago fiber optic (50 MBaud) Standard PC connectors (monitor, keyboard, mouse and network) 90-132 or 185-260V, (115/230 auto) 50/60 Hz Dimensions (WxDxH) 43.2 x 27.4 x 8.9cm (17 x 10.8 x 3.5 ) Weight Operating temperature Storage temperature Relative humidity Maximum altitude Approx. 5 Kg (11 lbs) 10 to 40 ºC (50 to 104ºF) -55 to 85ºC (-67 to 185ºF) 10 to 90% non-condensing 2000 m (6562 ft.) OP4510 User Guide OPAL-RT Technologies 15

Specifications I/O Specifications I/O SPECIFICATIONS The OP4510 can hold any combination of four of the following Type B mezzanines. The standard OP4510-1 contains one of each. 32 Digital In (OP5353) Number of channels Isolation Connection mode Input current Reverse voltage protection Maximum reverse voltage protection Detection threshold Voltage range 32 digital inputs Optical isolator Anode and cathode available on connector 3.6 ma, current limiting diode Schottky diode 30 Volts Separate Schmitt Trigger 4 to 50 Vdc 32 Digital Out (OP5360-2) Number of channels Isolation Output Protection 32 digital outputs 2 banks of 16, fully isolated and independant of each other Galvanic isolator 50 ma resettable fuse Protection thresholds Over voltage: 30.1V Reverse voltage: maximum 30 V. Output Voltage range Output configuration 5 to 30 Vdc max Push-pull, tri-state output 16 OPAL-RT Technologies OP4510 User Guide

16 Analog In (OP5340) Specifications I/O Specifications Number of channels: 16 differential Resolution: 16 bits Input range (V) ±20v to ±120v 16 Analog Out (OP5330) Number of channels: Resolution: Default range: Maximum current: 16 single-ended 16 bits ± 16 Volts 15 ma RS422 Digital In Number of channels Detection threshold Input current Voltage range Delay Low-to-High RS422 Digital Out Number of channels High level (With load) Low level (With load) Voltage range Delay Low-to-High 6 differential inputs ± 0.2 V (for ± 7 V range) ± 0.5 V (for ± 15 V range) ± 3 ma 5 Vdc 65 ns 6 differential outputs 2.5 V min @ -20 ma 0.5 V max @ 20 ma 5 Vdc 55 ns OP4510 User Guide OPAL-RT Technologies 17

Limited Warranty Limited Warranty LIMITED WARRANTY OPAL-RT Technologies Inc. warrants to the original purchaser and/or ultimate customer ( Purchaser ) of OPAL-RT products ( Product ) that if any part thereof proves to be defective in material or workmanship within one (1) year, such defective part will be repaired or replaced, free of charge, at OPAL-RT Technologies discretion, if shipped prepaid to OPAL-RT Technologies Inc. at 1751 Richardson, suite 2525, Montreal, Quebec, Canada, H3K 3G6, in a package equal to or in the original container. The Product will be returned freight prepaid and repaired or replaced if it is determined by OPAL-RT Technologies Inc. that the part failed due to defective materials or workmanship. Otherwise, the fees will be charged to the client (see article Warranty Limitation and Exclusion ). The repair or replacement of any such defective part shall be OPAL-RT Technologies sole and exclusive responsibility and liability under this limited warranty. Purchaser must request an RMA number before shipping any Product for repair: 1. Access the OPAL-RT website (www.opal-rt.com/support/ return-merchandise-authorization-rmarequest), click on support and select Return Merchandise (RMA). 2. Fill out the online form and submit. 3. OPAL-RT s Support department will evalute the return and either issue an RMA number via email -- If the Product is returned for repair more than 12 months after purchase, the Purchaser is responsible for the cost of repair. OPAL-RT will assess the repair and prepare a quote. The RMA number will be sent with the quote. 4. Only when the Purchaser receives the RMA number, may they ship the Product, prepaid, to OPAL-RT. Return Policy the following fees will apply when customers return products for credit: A full credit, less a 15% fee and less return fee will only be issued if the product is in perfect working condition and if the product is returned within 1 month following the shipping date. If repairs are required on the returned product, the cost of these repairs will be deducted from the credit to be issued. No credits will be issued beyond the one month period. Exclusions If third party products are part of the Product, OPAL-RT will honor the original manufacturer s warranty. This limited warranty does not cover consumable items, such as batteries, or items subject to wear or periodic replacement, including lamps, fuses or filter elements. 18 OPAL-RT Technologies OP4510 User Guide

Warranty Limitation and Exclusion Limited Warranty OPAL-RT Technologies will have no further obligation under this limited warranty. All warranty obligations of OPAL-RT Technologies are void if the Product has been subject to abuse, misuse, negligence, or accident or if the Purchaser fails to perform any of the duties set forth in this limited warranty or if the Product has not been operated in accordance with instructions, or if the Product serial number has been removed or altered. Disclaimer of Unstated Warranties The warranty printed above is the only warranty applicable to this purchase. All other warranties, express or implied, including, but not limited to, the implied warranties of merchantability or fitness for a particular purpose are hereby disclaimed. Limitation of Liability It is understood and agreed that OPAL-RT Technologies liability, whether in contract, in tort, under any warranty, in negligence or otherwise shall not exceed the amount of the purchase price paid by the purchaser for the product and under no circumstances shall OPAL-RT Technologies be liable for special, indirect, or consequential damages. The price stated for the product is a consideration limiting OPAL-RT Technologies liability. No action, regardless of form, arising out of the transactions under this warranty may be brought by the purchaser more than one year after the cause of actions has occurred. OP4510 User Guide OPAL-RT Technologies 19

CONTACT OPAL-RT Corporate Headquarters 1751 Richardson, Suite 2525 Montréal, Québec, Canada H3K 1G6 Tel.: 514-935-2323 Toll free: 1-877-935-2323 Note: While every effort has been made to ensure accuracy in this publication, no responsibility can be accepted for errors or omissions. Data may change, as well as legislation, and you are strongly advised to obtain copies of the most recently issued regulations, standards, and guidelines. This publication is not intended to form the basis of a contract. Technical Services www.opal-rt.com/support UM15-18121_RVN 1.0 12/2015 OPAL-RT Technologies Inc.