Programming and Using the Motorola V.3400 Modem for Remote Operation of the DDF6000

Similar documents
Telenetics dial modems are based upon Rockwell chipsets. These chipsets contain Rockwell's "AT" command set.

Chapter 5 AT Commands

AT Commands - Trust 56K PCI Modem - Executing commands

Select a Data Communication Interface

3600 Modem User s Guide

Appendix A Cable Pinouts

Cable Pinouts. SRP I/O Module

Sender Receiver Sender

Conitel ASYNC Adapter

ASYNC Sharing Unit TABLE OF CONTENTS SECTION 1 - DESCRIPTION...2 SECTION 2 - SPECIFICATIONS...5 SECTION 3 - INSTALLATION...7

The modems are made in industrial 108mm wide aluminium housing for DIN rail mounting. UCM RS232 interface

V.3229 / V.3229L Installation and Operation

ASYNC Sharing Unit TABLE OF CONTENTS SECTION 1 - DESCRIPTION...2 SECTION 2 - SPECIFICATIONS...5 SECTION 3 - INSTALLATION...7

Cabling Guide for Console and AUX

Miniature Asynchronous 4-Wire High Speed Modems

ZM56 High-Speed Industrial Modem. Command Summary. 1 ZM56 High-Speed Industrial Modem

LM048 Bluetooth v2.0, v2.1 RS232 Serial Adapter Standalone (With Embedded Bluetooth v2.0 / v2.1 Stack)

Table 8 shows the pin configuration and function of a standard computer-to-printer parallel cable. Table 8 Parallel Cable Pin Configuration

+ (5~27 VDC) GND. Bluetooth V4.2 BLE RS-232 Serial Adapter. Model: BLE-232D-E. 1. Package content: BLE RS-232 adapter

STEP X - Name of Step QUICK START GUIDE SP385A-R3, SP390A-R3 USB TO RS CONVERTER 24/7 TECHNICAL SUPPORT AT OR VISIT BLACKBOX.

Product: Z34-SX, Z34-RX, Z34-SE, Z34-RE, Z32t-SX, Z32t-SE, Z32t-RX, Z32b-SX, Z32b-SE, Z32b-RX

Bluetooth V4.1 BLE RS-232 Serial Adapter Model: BLE-232B Bluetooth V4.2 BLE RS-232 Serial Adapter Model: BLE-232C

USER S MANUAL. PH232Ex1. #1 RS-232 Serial Port to Ethernet, Terminal Server/Client. Doc No: PH232Ex1-UM-001 IPEX. (IP Electronix)

SCADA Point-to-Point Multiplexer

Serial Interfaces Part 1. ECE 153B Sensor & Peripheral Interface Design Winter 2016

CMM 900-3W USER GUIDE

2001 by NEC America. All Rights Reserved. Printed in U.S.A.

Note: For BANDIT II, BANDIT III, or VSR-1200 specifications, see the BANDIT II, BANDIT III, and VSR-1200 Document Set. Function

PCL Port RS-232 Interface Card

LM058 Bluetooth v2.0, v2.1 RS232 Serial Adapter - SMA Connector Standalone (With Embedded Bluetooth v2.0 / v2.1 Stack)

RCS/6000. Hardware. Manual

LM068 Bluetooth v4.1 Dual Mode RS232 Serial Adapter Standalone (With Embedded Bluetooth v4.1 Stack)

SCADA Multidrop Multiplexer

USER MANUAL. G.shdsl+ modem with G.703 interface TAHOE 671 FREEDOM OF COMMUNICATION

E1 and T1 RJ-48 Cable Pinouts on page 208. Fast Ethernet 12-port Cable Pinouts on page 211

Sutron Voice Modem Operation Manual

DATA CONNECT ENTERPRISE

RTU-COM PSTN AT. User Guide

Cellular modem and Transceiver

+ (5~27 VDC) GND. Bluetooth V4.1 BLE RS-232 Serial Adapter. Model: BLE-232B. 1. Package content: BLE RS-232 adapter

Document Name : User Manual for SC10B : RS232 to Bluetooth Converter.

x2 COMMANDS & TECHNICAL REFERENCE

User's Manual PLC09 Modbus Converter for PAL-AT Leak Detection System

User Manual V1.1 Date: WiFi RS-232 Adapter. Red LED: IP Address Blue LED: TX/RX 5V Out (Pin 9)

Modem AT Command Set

4.3 Digital Communication

RM024 DVK USER GUIDE VERSION 1.2

RS-422 Code-Operated Switches

TRP-C37M User s Manual

User Guide. Date Apr BlueEva+C11/G2. Stollmann. E + V GmbH. User Guide

TRP-C37M User s Manual

Modem MODEM AUGUST 1999 MD885A-R2 MD885A-R3 MD885AE-R2 MD885C-R Rev. A CUSTOMER SUPPORT INFORMATION

MODEL DSU Kbps Rack Mount CSU/DSU OPERATOR S MANUAL. 280 I-80 West Exit 1 PO Box 1330 Verdi NV 89439

Cable Specifications. Interface Specifications. Fiber-Optic Specifications APPENDIXB

Industrial Serial Device Server

Bluetooth TO Serial CONVERTER E-P132-B

Communication adapter RS232 over the Wi-Fi ELO E231. User manual

SRX Multidrop TABLE OF CONTENTS SECTION 1 - DESCRIPTION...2 SECTION 2 - SPECIFICATIONS...4 SECTION 3 - INSTALLATION...6

INTRODUCTION 2 FEATURES. 2 SPECIFICATIONS. 2 PIN ASSIGNMENT 2 DB-9 DB-25 CONVERSION TABLE. 2 DRIVER INSTALLATION QUICK GUIDE.. 2

STAR Comm Modem Kit for the Micro/PX-2000: Setup Instructions

Hardware Manual. PCMCIA 1 Port RS EDITION APRIL 1999

Low Speed Modems for Dial and Leased Circuits 2400E (Standalone) 2400R (Rackmount)

Connector and Cable Specifications

Quick Start Guide. 2-Port 10/100 Device Server RS-232/422/485 DB9 M. Access two serial RS-232 or RS-422/485 devices over a 10- or 100-Mbps network.

USER MANUAL. MODEL 1018 High Speed Short Range Modem w/ Extra Controls SALES OFFICE (301) TECHNICAL SUPPORT (301)

USER MANUAL HPS-120. About this product: Your Communications Solutions Provider

Wrenchman, Inc Old Hwy. # 8 Suite # 122 New Brighton, Minnesota (651)

Lantech LSC-1102B SERIAL TO TCPIP CONVERTER. User Manual

Bluetooth to RS-232 Converter. RT-132B Bluetooth Adaptor Operation Manual

Serial Bluetooth Smart Adapter - RS232, Low Energy 4.2 BLE Datasheet and Quick Reference for USBLE232C

LM058 Bluetooth Serial Adapter SMA Antenna 100m m Range SPP GAP + Wireless DTR DSR RTS CTS

3.1 I-7560 Pin Assignment and Specifications: Introduction

Starter Guide Version Sphinx Access Control System

LM058 Bluetooth Serial Adapter

MS Protocol Converter. User Manual. Firmware version 2.0 ISI. Instrumental Solutions, Inc.

IML 560 USER GUIDE. Low Power 56Kbps Industrial modem. Version 1.2. December 6, AYANTRA Inc.

NOTE: The numbers in the wiring diagrams do not show the order of connection. Follow the written instructions to make the connections.

Bluetooth to RS-232&RS422/485. EX-9132B/BI Bluetooth Adapter Operation Manual

Serial Bluetooth Smart Adapter - RS232, Low Energy 4.1 BLE Datasheet and Quick Reference for BLE232V2

Serial Link Generic Tank Mode Installation Manual. Pro Fuel Management System. RE Rev C July 00

USER MANUAL. MODEL 1052 idsl Modem with RS-232 Interface. An ISO-9001 Certified Company SALES OFFICE (301) TECHNICAL SUPPORT (301)

Document Name: User Manual for SC10MK, Modbus RTU to Modbus TCP Converter

Multi-Port Controller

Galep-Adapter DIL-40 => ISP-ASYNC/SYNC Article-No.:

EZL-200F Application Notes (003) Serial Interface (RS232/RS422/RS485)

TechMemo # B. AlphaEclipse and Alpha signs. See Alpha and AlphaEclipse sign data formats on page 13 for a list of signs.

ZM24x Quick-Connect Industrial Modem. User s Manual

RS-232 to Logic Level Adapter with DB9M Connector and Power LED

GNS-MC35iT, GNS-MC35iU Terminals datasheet

TRP-C37. Ethernet to RS232/422/485 Converter. User s Manual. Printed Apr.2014 Rev 1.3

USER MANUAL. MODEL 2011 High Speed Asynchronous to Synchronous Converter

RS-232/422/485 to Copper or Fiber. Ethernet Converter. User s Manual

ATLAS Quad USSI Module

Bluetooth RS232 Serial Adapter

Dual Serial Shield User Manual

User Manual A08. User Manual

User Manual. ASeries A704

ARC Modem Low Power Modem LP9624

NCOM SERIAL DEVICE SERVER 4XX SERIES USER S MANUAL

Chapter 11: Input/Output Organisation. Lesson 05: Asynchronous RS232C Serial Port data transfer

Transcription:

Programming and Using the Motorola V.3400 Modem for Remote Operation of the DDF6000 1.0 Introduction A Technical Application Note from Doppler Systems April 11, 1999 Version 3.x of the DDF6000, running version 2.x of the BrgTrack software, allows one or more of these direction finders to be controlled remotely over telephone lines. In the past, radio modems were required for the purpose. To check which firmware version you are using, watch the front panel display of the DDF6000 during power turn-on; to check the software version, use the Help About BrgTrack menu on the PC. If you are going to need an upgrade, see the Software & Upgrade page on the web site, or seek help from your local distributor or from the factory. 2.0 Configuration A modem pair is required for each remote site. The "calling" modem is located at the central control point where the PC running BrgTrack is located, and the "answering" modem is located at the remote site. If only one remote site is needed, the PC's COM port will connect to the sending modem using a 3-wire serial cable as shown in Figure 1. If multiple sites are to be connected, the Serial Expander, DDF6077 should be used. See Figure 2. A Serial Expander will interface a single PC COM port with up to three calling modems. If more than three sites are to be connected, multiple Serial Expanders may be used. See Figure 3. (The number of sites that may be connected using N Serial Expanders is equal to 2N + 1). Figure 1

Figure 2 Figure 3

3.0 Motorola V.3400 Modem This modem is suitable for use as either the calling or answering modem with either leased lines or standard dial up lines. It is an external modem having a liquid crystal display and front panel switches that permit programming, control, dialing, etc. from the panel. It is therefore unnecessary to use AT commands to set up these modems. Although the setups given below work with the V-3400 modem, there are other modems in the same series which should work very similarly, such as the Motorola V.32E. 4.0 Modem Setup The modems may be set up from their front panels with only the power connected. The phone lines and/or RS232 cables may be connected or not during programming. Use the YES, NO and TALK/DATA switches to scroll through the menus and make the selections as described in the V.3400 manual. The menu selections listed below work well; however, many of the options could be changed with little or no effect on the operation. For completeness in following the modem menus, all of the selections are listed. Note that the final menu item listed stores these settings for automatic loading after power turnon. 4.1 Calling Modem with Leased Line CONFIGURATION MENU Modem Options Protocol Options DTE Options Test Options SETTINGS Leased Line / 2 Wire / Mod is V.34 / DCE Max Rate 28800 / DCE Min Rate Disabled / V.34 Rate Thresh High BER / V.34 Asym Rates Enabled / Normal Originate / V.32b Fast Train Enabled / Auto Retrain Enabled / SQ Auto Rate Disabled / Internal Clock / Dial Line Jack RJ11 / Dial TX Level -12 dbm / Lease Line Level -15 dbm / Line Current Dis Short / Auto Dial Backup / Loopback Time 15 Min LAPM Prot Enabled / MNP Prot Enabled / Protocol Fallback Enabled / Data Compression Normal / Constant DTE Speed / DTE Flow Control Disabled / DCE Flow Control Disabled / XON-XOFF Pass Thru Disabled / Inactivity Timer Off / Break Option #0 / V.42 Fast Detect Disabled Ayync Data / DTE Rate 2400 / 8 Bit Char / No Parity / AT Cmd Set Enabled / Ignore DTR / DSR Normal / DCD Normal / CTS Forced High / DTE Fallback Disabled / Options Retained at Disc Bilateral Digital Loop Disabled / DTE Local Test Disabled / DTE Remote Test Disabled / Remote Commanded Enabled / Test Timeout Off Dial Options Dial Type Tone / Autodial #1 / Wait for Dial Tone / Wait Delay 2 Sec /

Pause Delay 2 Sec / Call Timeout 30 Sec / Answer Ring #1 / Autocallback Disabled Speaker Operation Load/Store Options Set Volume Control Medium / Speaker On Until Carr Detect Load Factory Option? NO / Load User Option Set? NO / Store Present Options? YES - 1 / User Option at Reset 1 4.2 Answering Modem with Leased Line CONFIGURATION MENU Modem Options Protocol Options DTE Options Test Options Dial Options Speaker Operation Load/Store Options Set SETTINGS Leased Line / 2 Wire / Mod is V.34 / DCE Max Rate 28800 / DCE Min Rate Disabled / V.34 Rate Thresh High BER / V.34 Asym Rates Enabled / Forced Answer / V.32b Fast Train Enabled / Auto Retrain Enabled / SQ Auto Rate Disabled / Internal Clock / Dial Line Jack RJ11 / Dial TX Level -12 dbm / Lease Line Level -15 dbm / Line Current Dis Short / Auto Dial Backup / Loopback Time 15 Min LAPM Prot Enabled / MNP Prot Enabled / Protocol Fallback Enabled / Data Compression Normal / Constant DTE Speed / DTE Flow Control Disabled / DCE Flow Control Disabled / XON-XOFF Pass Thru Disabled / Inactivity Timer Off / Break Option #0 / V.42 Fast Detect Disabled Async Data / DTE Rate 2400 / 8 Bit Char / No Parity / AT Cmd Set Enabled / Ignore DTR / DSR Normal / DCD Normal / CTS Forced High / DTE Fallback Disabled / Options Retained at Disc Bilateral Digital Loop Disabled / DTE Local Test Disabled / DTE Remote Test Disabled / Remote Commanded Enabled / Test Timeout Off Dial Type Tone / Autodial #1 / Wait for Dial Tone / Wait Delay 2 Sec / Pause Delay 2 Sec / Call Timeout 30 Sec / Answer Ring #1 / Autocallback Disabled Volume Control Medium / Speaker On Until Carr Detect Load Factory Option? NO / Load User Option Set? NO / Store Present Options? YES - 1 / User Option at Reset 1

4.3 Calling and Answering Modems with Dialup Line CONFIGURATION MENU Modem Options Protocol Options DTE Options Test Options Dial Options Speaker Operation Load/Store Options Set SETTINGS Dial Line/ Modulation is Automode / DCE Max Rate 28800 / DCE Min Rate Disabled / V.34 Rate Thresh High BER / V.34 Asym Rates Enabled / V.22 Guard Tone 1800 Hz / V.32b Fast Train Enabled / Auto Retrain Enabled / SQ Auto Rate Disabled / Internal Clock / Dial Line Jack RJ11 / Dial TX Level - 12 dbm / Line Current Dis Short / Long Space Disc Enabled LAPM Prot Enabled / MNP Prot Enabled / Protocol Fallback Enabled / Data Compression Normal / Constant DTE Speed / DTE Flow Control Disabled / DCE Flow Control Disabled / XON-XOFF Pass Thru Disabled / Inactivity Timer Off / Break Option #0 / V.42 Fast Detect Disabled Ayync Data / DTE Rate 2400 / 8 Bit Char / No Parity / Async Controlled Dialer / AT Cmd Set Enabled / Ignore DTR / DSR Normal / DCD Normal / CTS Forced High / DTE Fallback Disabled / Options Retained at Disc Bilateral Digital Loop Disabled / DTE Local Test Disabled / DTE Remote Test Disabled / Remote Commanded Enabled / Test Timeout Off Dial Type Tone / Autodial #1 / Wait for Dial Tone / Wait Delay 2 Sec / Pause Delay 2 Sec / Call Timeout 30 Sec / Answer Ring #1 / Autocallback Disabled Volume Control Medium / Speaker On Until Carr Detect Load Factory Option? NO / Load User Option Set? NO / Store Present Options? YES - 1 / User Option at Reset 1 On the calling modem, you will also need to go to the CHANGE PHONE NUMBER menu and enter the phone number of the answering modem. 5.0 Modem Operation 5.1 Calling Modem to PC Cable All that is required is a 3 wire shielded cable that connects the calling modem to the COM port on the PC. Signal PC DB25 (female) pin PC DE9 (female) pin Calling modem DB25 (male) pin

TXD 2 3 2 RXD 3 2 3 Ground 7 5 7 5.2 Answering Modem to DDF6000 Cable A 3-wire shielded cable is required that connects the following signals on the answering modem to J1 on the DDF6000. Signal Answering modem DB25 (male) pin DDF6000 J1 (female) pin TXD 3 3 RXD 2 2 Ground 7 5 5.3 Testing the Modems - Leased Line Configuration Connect a DDF6000 to an Answering Modem and connect a Calling Modem to the PC. Connect the two modems together with a jumper cable having RJ45 (8-conductor) plugs. Use the jacks marked AUX/LEASED LINE (furthest from the RS232 connectors) on the modems. Turn the modems on. After a few seconds of handshaking the two modems will connect. When this happens, the displays on both modems will say "ON LINE" and the carrier detect CD LED will be lit. Be sure that a plug is inserted in J4 on the DDF6000 to place it in the CIV mode. Turn on the power to the direction finder with the plug installed. To test the network, you do not need to have a receiver or direction finder antenna connected. You can place the direction finder in a "self test" mode by selecting (from the front panel) Sweep = 0, Cal = ON, Sig = 9). The DF should display a bearing. When you finish these tests, you can turn off the self test mode using the same command sequence. Execute BrgTrack on the PC. Check that the proper COM port has been selected (Setup Serial Port), then check that the DF address matches that of the DDF6000 connected. (The default value is 1). Select Setup Site, Enable one site, select Modify, and set the DF-id to the address of the DDF6000. If a CIV receiver is connected to the DDF6000, check that its address also matches that shown in the RX-id field. Select Locate on Map and be sure that the site location is shown somewhere on the screen. If a CIV receiver is not connected to the DF, be sure that no channels are enabled (Setup Channels Disable).

Now place BrgTrack in the RUN mode. The RD and TD lights on both modems should blink and the BrgTrack screen should display a bearing. To verify that the system will restart after a power failure, turn the DDF6000 Off. BrgTrack will display an error message. Turn the DDF6000 back ON then click on "Yes" to restart BrgTrack's polling sequence. Turn off the power on the answering modem. BrgTrack will again display an error message and after brief interval, the CD light on the calling modem will go off. Turn the power back on and wait until the calling modem light returns to on. This may take several seconds. Now click the "Yes" button to restart BrgTrack. Turn off the power on the calling modem, turn it back "on", and wait for the CD light to indicate that the modems have re-established communication. Restart BrgTrack using the "Yes" button. If you will be connecting to multiple sites, repeat the above tests using the next modem pair. 5.4 Testing the Modems - Dialup Line Configuration Connect a DDF6000 to an Answering Modem and connect a Calling Modem to the PC. Connect each of the modems to a different telephone line using a jumper cable having RJ11 (2 or 4 conductor) plugs. Use the jacks marked DIAL LINE (closest to the RS232 connectors) on the modems. Turn the modems on. From the front panel of the sending modem, press the NO switch to select the menu Dial Stored Number. Select the number of the answering modem and press YES to initiate the dialup process. After a few seconds of handshaking the two modems will connect. When this happens, the displays on both modems will say "ON LINE" and the carrier detect CD LED will be lit. Be sure that a plug is inserted in J4 on the DDF6000 to place it in the CIV mode. Turn on the power to the direction finder with the plug installed. To test the network, you do not need to have a receiver or direction finder antenna connected. You can place the direction finder in a "self test" mode by selecting (from the front panel) Sweep = 0, Cal = ON, Sig = 9). The DF should display a bearing. When you finish these tests, you can turn off the self test mode using the same command sequence. Execute BrgTrack on the PC. Check that the proper COM port has been selected (Setup Serial Port), then check that the DF address matches that of the DDF6000 connected. (The default value is 1). Select Setup Site, Enable one site, select Modify, and set the DF-id to the address of the DDF6000. If a CIV receiver is connected to the DDF6000, check that its address also matches that shown in the RX-id field. Select Locate on Map and be sure that the site location is shown somewhere on the screen. If a CIV receiver is not connected to the DF, be sure that no channels are enabled (Setup Channels Disable).

Now place BrgTrack in the RUN mode. The RD and TD lights on both modems should blink and the BrgTrack screen should display a bearing. To verify that the system will restart after a power failure, turn the DDF6000 Off. BrgTrack will display an error message. Turn the DDF6000 back ON then click on "Yes" to restart BrgTrack's polling sequence. Turn off the power on the answering modem. BrgTrack will again display an error message and after brief interval, the CD light on the calling modem will go off. Turn the power back on and redial the answering modem from the calling modem front panel. After the modems connect, click the "Yes" button to restart BrgTrack. Turn off the power on the calling modem, turn it back on, and again redial the answering modem. After the modems connect, restart BrgTrack using the "Yes" button. If you will be connecting to multiple sites, repeat the above tests using the next modem pair. 5.5 ICOM R8500 Setup Note Be sure that the CIV Transceive Mode is turned OFF when using this receiver. See page 32 of the IC-R8500 Instruction Manual for the procedure for changing the CIV Address and the CIV Transceive Mode. 5.6 Testing Multiple Modem Connections Before testing multiple modems and DF's you need to set the addresses of each DDF6000 to a unique value using the RDFCMD program provided with the direction finders. Connect a DDF6000 to the PC serial port (using a minimum 3-wire cable), execute RDFCMD, select the proper COM port, select DF serial port J1, select CIV protocol, enter the current CIV address (1 unless you have already changed it), and enter anything for the receiver CIV address. Enter command 0 (Bearing Data Rqst) and verify that the a response message is received. To change the CIV address, enter command 4 from the Main menu to reach the RDF Address Menu, enter the new CIV address, then hit the ESC key twice to exit the program. If you will be using CIV receivers at each site, you need to also set unique addresses on these. Refer to the ICOM receiver manual for instructions on setting the CIV addresses. Connect the female connector on the serial data expander to the PC using the cable provided with it (the 3 conductor shielded DE9 male to DE9 female), and connect the calling modems to the male connectors on the serial data expander. With BrgTrack in its off mode, setup the CIV addresses for the direction finders and receivers at each site to match those connected to the network.

Turn all the direction finders and modems on and wait until all the modems are communicating properly as indicated by stable CD indications on the calling modems. Now click on Run in BrgTrack. You should see bearings displayed at each site (assuming that all direction finders are still in the self test mode). 6.0 Timing The following timing diagrams are provided as an aid in case you experience difficulty with communications after setting up the modems. Figure 4 shows the timing obtained using the Motorola V.3400 modem on a leased or dial up line. Figure 5 illustrates the timing that results when a direct (local) connection is made between the PC and the DDF6000. Figure 4 Figure 5 7.0 Final Installation When all of the modems, direction finders, receivers, serial data expanders and the PC are operating reliably in the same area, you are ready to locate the answering modems, direction finders and receivers to the remote sites and connect them to the actual telephone lines. Be

sure to note the CIV addresses of the direction finders and the receivers so that they are installed at the correct site locations. Also, be sure not to mix up the calling and answering modems. Remember to switch off the self test mode on the direction finders.