OT EASY 60 II. LED control unit Operating instructions

Similar documents
DALI Professional Controller-4. Control unit Operating instructions

Operating instructions I / 2010

Operating instructions

Light is easy to control DALIeco: Multi-functional light management system for luminaire and ceiling integration Light is OSRAM

Product and functional description

Electrical devices may only be mounted and connected by electrically skilled persons.

1 Safety instructions. 2 Device components. 3 Function. DALI Tronic transformer 105 W. Order-No. : Operating instructions

1 Safety instructions. 2 Device components. 3 Function. IC00P01DAL - DALI gateway. DALI gateway. Operating instructions

Installation Instructions

LED Driver Linear / area dimming

DALI Professional Frequently asked questions Light is OSRAM

KNX DALI Gateway Plus - User Manual

PTo 150/ DIM HCI 150 W, HQI 150, NAV 150 W, and other similar commercially available 150 W lamps System wattage:

LL1x50-E-DA. 1x50 W Dimmable DALI LED driver. 50 W V 0 / 50 Hz 60 Hz. Functional description. Mains characteristics

LED Driver DC-String

1 Safety instructions. 2 Device components. 3 Function. DALI transformer W. Art.-No.: D SNT 105. Operationsmanual

LL1x150-CR-DA. 150 W Dimmable DALI-2 LED driver. 150 W V 0 / Hz. Functional Description. Mains Characteristics

Data sheet. Function description. Benefits

Installation Instructions

w w w. p r o l i g h t. c o. u k STAGE PAR 64

PHASED OUT. LED control gear Linear / area dimming. Uconverter LCAI 70 W 300 ma I010 one4all V ECO series

4 Channel DMX Driver Instruction Manual

Product and functional description

COMPACT LED DRIVERS. PrimeLine DALI dimmable & Selectable Current (Dip Switch) PrimeLine DALI DIMMABLE & SELECTABLE CURRENT (DIP SWITCH)

Operating instructions Evaluation system for flow sensors VS / / 2013

KNX/EIB Flush-mounted universal dimming actuator 210 W. 1 Safety instructions. 2 Device components. Order-No. : Operating instructions

LED Driver DC-String

Blitzer Strobe. User Manual. Order code: EQLED366

LED Driver Compact fixed output

LED Driver Compact fixed output

LINEAR LED DRIVERS. PrimeLine DALI dimmable. PrimeLine DALI DIMMABLE , , , , ,

LED PANEL. User Manual Please read the instructions carefully before use LED-7TC. Innovation, Quality, Performance 15-

RGB Power Batten. User Manual. Order code: EQLED032

LED Driver Compact fixed output

LL1x80-CR-DA. 80 W Dimmable DALI-2 LED driver. 80 W V 0 / Hz. Functional Description. Mains Characteristics

PHOENIX CONTACT - 07/2006

Microbar COB System. User Manual. Order code: EQLED137

Non-communicating room controllers

ColourChaser Touch. Installation Guide

Blitzer RGB Strobe. User Manual. Order code: EQLED365

LC35SE-CC LOOP

LC51SE-CC LOOP

LED Driver Compact fixed output

LED Driver Compact fixed output

KasBar COB Tri 5. 5x15w 3in1 COB LEDs (RGB) USER MANUAL

w w w. p r o l i g h t. c o. u k TRI PAR 64 Order code: LEDJ48 - Black Order code: LEDJ49 - Polished USER MANUAL

DALI Link User Manual

Product and Applications Description. Example of Operation. Installation Instructions WARNING. Note. Application Programs

w w w. p r o l i g h t. c o. u k Quad Par 64 (Order code: LEDJ46 - Black) (Order code: LEDJ47 - Polished) USER MANUAL

LED Driver Compact fixed output

Operating instructions. Speed monitor D / / 2014

LED Driver Compact fixed output

LC35SE-DA W SELV Dimmable DALI-2 LED driver. 35 W V 0/ Hz. Functional Description. Mains Characteristics

Universal dim actuator 1gang RMD Universal dim actuator 2gang RMD Universal dim actuator 4gang RMD

LED PANEL. User Manual Please read the instructions carefully before use LED-212RGB TABLE OF CONTENTS. 1. Safety Instructions

TABLE OF CONTENTS 1. Safety Instructions 2. Technical Specifications 3. Installation 4. How to Connect the Fixture 5. DMX512 Connections 6.

Colour Burst Order code: LEDJ01 USER MANUAL

Gobo Projector XP 80W

LED Driver Compact fixed output

HAIKU WALL CONTROL KIT

Order code: EQLED60 USER MANUAL

ABB i-bus KNX DALI Light Controller, 8-fold, MDRC DLR/S M, 2CDG110101R0011

High Power Electronic Gear Installation and operation Guide

QUINT-BUFFER/24DC/24DC/40

Network nodes with gateway

IF-80x Outdoor Terminal

THE CTB08D LIGHT CONTOLLER

C9900-P208 and C9900-P209

Slimline CW & WW Series

User Guide Attracta Magnetic Lighting

Operating and mounting instructions

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description

User Manual Equinox 2m Flight Cased DMX LED Flame Machine Order code: FLAM12

basicdim Wireless Wireless module for basicdim

seetouchtm B&O Keypads 15 V 65 ma NEC Class 2; IEC PELV

Brief instructions Illumination unit O3M /00 09/2014

E600 VX01 Installation guide

1 Channel Strobe Controller ORDERCODE 40226

Pro Series LED Controllers Part numbers: pro-4-in-1-receiver, dim-pro-knob-us-w dim-pro-knob-wa, dim-pro-knob-rgb, rgbw-pro-touch, rgb-pro-remote

UV Spectra Batten 12 x 5W UV LEDs

LED converter Linear / area dimming. Uconverter LCAI 70 W 300 ma I010 one4all V ECO

OPERATING INSTRUCTIONS

Vector Beam White. User Manual. Order code: LEDJ265

LED Slimline PAR RGBW 7x8W

Withstands max. 320 VAC (max. 1 hour) *) Low frequency, LED load: Cree XP-G L LEDs. 350 ma 600 ma Fixed output 850 ma P Rated

SK CU4-PBR-C Part number:

LCC1653/01, LRI1653/01 ActiLume DALI System

Operating Instructions. DALI-Gateway

Performer 18 RGBWA MKII

C9900-P223 and C9900-P224

LED Driver Compact fixed output

RAD-DI8-IFS. I/O extension module with 8 digital inputs or 2 pulse inputs. INTERFACE Data sheet. 1 Description

EasiLED 4 DMX Controller

Performer 18 HEX. 18 x 12W 6-in-1 colour LEDs (RGBWAUV) User Manual. Order code: LEDJ252B

Product and functional description

LinkRay LED Drivers EasyLine With Selectable Current , Typical Applications

Torque Series LCD Remote Panel Installation/Operation Manual Model: TQ-DSP-12/24

Fusion Razor Beam. 3 x 12W Moving Head User Manual. Order code: EQLED006

LED Driver Linear / area dimming

LED Driver Compact fixed output

Transcription:

II LED control unit Operating instructions

Contents Safety... 4 General instructions 4 Safety instructions 4 Intended use 4 Description... 5 Function and application 5 Function 5 Important definitions 5 Scene, lighting scene 5 Sequence 5 Fade time 5 Cycle time 5 Operating modes 6 Behaviour after a power failure 6 Connections 6 Installation... 7 Connecting the control unit 7 Wiring diagram 7 input connections 7 Connecting the inputs 8 output connections 9 Connecting the outputs 9 Expanding the system 10 Master-slave circuit 10 Procedure 10 Wiring diagram (example of a master-slave circuit) 11 Operation... 12 Remote control 12 Activating the operating modes 13 Switching on and off the luminaires 13 Changing the brightness manually 13 Storing and calling up a lighting scene 14 Disabling scene storage 14 Starting and ending the sequencer mode 14 Setting the fade and cycle time 15 Example of a sequence 15 Example of a daylight simulation 16 Troubleshooting 16 Appendix... 17 Technical data 17 Applicable standards 18 Dimensions 18 3

Safety Safety General instructions Safety instructions The control unit must only be installed and put into operation by a qualified electrician. The applicable safety regulations and accident prevention regulations must be observed. WARNING! Exposed, live cables. Danger of electric shock! Only work on the control unit when it is de-energised. Intended use CAUTION! Destruction of the control unit and other devices through incorrect mounting! Ensure that the external pushbutton is designed for the mains voltage. Do not wire the control and pushbutton lines with an external voltage, especially not a mains voltage of 230 V. Do not exceed the maximum number of connectable components. Only use the intended infrared receiver types. The II control unit may only be operated in the operating modes described in the Description section. All other applications are considered to be inappropriate use. If the II control unit is not used as intended, there is no guarantee that it will operate safely. 4 IV 2009

Description Description Function and application Function Important definitions The II LED control unit can be used to implement static and dynamic lighting concepts. The II LED control unit enables the manual and automatic control of up to four LED luminaire groups on separate channels. Up to 4 x 16 lighting scenes can be programmed, called up individually or run through cyclically in up to 4 sequences (e.g. to simulate daylight). A colored light mixing system can be set up by assigning LED colors to the outputs. The functions can be executed via a remote control, pushbutton, switch, timer switch, motion detector or PC, depending on the installation. Scene, lighting scene A lighting scene defines the lighting situation in a room or the color resulting from the mixing of individual LED colors (red, green, blue). Example 1: Coloured effect lighting The LEDs have different colors (red, green, blue, white). They are set to different brightness levels according to the desired shade of color (mixed color of the room lighting). This mixing color is a lighting scene. Example 2: Daylight simulation White LED modules with different colour temperatures of 3300 K and 6500 K in conjunction with red and blue LED modules are suitable for daylight simulation in areas at a great distance from a window front, ceiling lights and task lighting with variable colour temperatures. Very slow cross fades are imperceptible to the human eye. Sequence A sequence is the automatic retrieval of stored lighting scenes and their cyclic playback. Fade time The fade time is the time in which the lighting system changes from one lighting scene to the next in sequencer mode. Cycle time The cycle time is the time in which the daylight simulation system runs through a complete daylight cycle. IV 2009 5

Description Operating modes II has three operating modes: Lighting control mode: Brightness is adjusted manually, and luminaire groups and lighting scenes are switched on and off manually. Sequencer mode: The stored lighting scenes are called up automatically one after the other. The fade time between the lighting scenes is adjustable. Daylight simulation: The lighting scenes are called up automatically to simulate light conditions as they change during the course of a day. Lighting scenes and cycle time (= duration of the day ) can be adjusted. Behaviour after a power failure Connections The LED modules connected to the control unit behave as follows if there is a power failure: Lighting control mode: The last state prior to a power failure is automatically restored. Sequencer mode: After the power supply is switched back on, e.g. by a timer switch, the sequence restarts with scene 1. Daylight simulation: After the power supply is switched back on, e.g. by a timer switch, the simulation restarts with the scene 1. The control unit has the following connections: Mains connection (A) Input for external pushbutton (B) Input for EASY signal (C) Outputs for connecting LED modules (D) A B C L N Easy signal 24 V (+) CH1 (R-) CH2 (G-) CH3 (B-) CH4 (W-) GND (-) D 6 IV 2009

Installation Installation Connecting the control unit Wiring diagram PE N L Power switch and / or timer switch (optional) External switch L N Easy signal 24 V (+) CH1 (R-) CH2 (G-) CH3 (B-) CH4 (W-) GND (-) + R G B LINEARlight Colormix LED module Y-connector Infrared receiver (optional) 4 Y-connector Pushbutton coupler (optional) USB adapter Y-Cconnector Max. total line length 100 m EASY PC kit (optional) input connections 2-wire cable Short circuit bridge for control units 16 mm 6 mm 6 mm input section L N EASY signal PRI 220 240 V 0/50/60 Hz Modular cable with 4p4c connector Rubber adapter IV 2009 7

Installation Connecting the inputs Proceed as follows: Step Task 1 Connect the 4p4c modular connector of the EASY signal line. 2 Strip the power cable, remove the insulation from the phase and neutral wires and connect to the screw terminals. 3 Connect the line of the external pushbutton to the screw terminals, if applicable. 4 Mount the cable strain relief: Use a rubber adapter and cable clamp that are suitable for the power cable diameter; see figure. 5 Insulate the PE conductor, if necessary. Ø (G) mm 6-7.5 7.5-8.5 Cable strain relief H G E F 8.5-9 E F G H Modular cable Rubber adapter for modular cable Power cable Cable clamps 8 IV 2009

Installation output connections output side 16 mm 24 V (+) CH1 (R-) CH2 (G-) CH3 (B-) CH4 (W-) GND (-) 6 mm 16 mm 3-wire cable (without PE) 6 mm Connecting the outputs Connection lines between the control unit and LED modules: Two 3-wire lines (without PE) with the same external diameter Max. length: 10 m Recommended line diameter: 1.5 mm² (line length < 5 m) or 2.5 mm² (line length > 5 m) Proceed as follows: Step Task 1 Strip the 3-wire lines, remove the insulation and connect to the screw terminals. 2 If the GND wire is unused, insulate it on the side of the LED module. 3 Use cable clamps. J K K J Cable clamp K 3-wire line (2 x) IV 2009 9

Installation Expanding the system Master-slave circuit In a master-slave circuit, up to 16 DALI EASY or OT EASY control units can be controlled simultaneously via a single remote control, up to two pushbutton couplers or a single PC. Note: Configuration of the master-slave circuit via a PC: see the operating instructions of the EASY Color Control Software. Procedure Proceed as follows to set up a master-slave circuit: Step Task 1 Disconnect all control units from the mains supply. 2 Connect an external pushbutton to the control unit that is to serve as the master, or leave the input vacant. 3 For the remaining control units, which operate as slaves, use the bridge at the input for the external pushbutton. 4 Connect the control units via Y-connectors and connect the connection lines with each other. 5 Connect the infrared receiver and pushbutton coupler to one of the Y-connectors (optional). Note: Connect a maximum of four infrared receivers and two pushbutton couplers. 6 Reconnect all control units with the mains supply. 10 IV 2009

Installation Wiring diagram (example of a master-slave circuit) CAUTION! Destruction of the control unit and other devices! Master-slave connection lines conduct protective extra-low voltage signals; do not route together with power supply or LED lines. Ensure that the master-slave connection lines are sufficiently insulated against the power supply or lamp lines. PE N L Power switch and/or timer switch (optional) Master External switch L N Easy signal 24 V (+) CH1 (R-) CH2 (G-) CH3 (B-) CH4 (W-) GND (-) + R G B LINEARlight Colormix LED module Infrared receiver or additional EASY components Y-connector Slave L N Easy signal 24 V (+) CH1 (R-) CH2 (G-) CH3 (B-) CH4 (W-) GND (-) + R G B LINEARlight Colormix LED module Y-connector Slave Y-connector L N Easy signal DALI EASY GND (-) CH4+ (W) CH3+ (B) CH2+ (G) CH1+ (R) ~ DA DA DALI ECG Red bulb 4 ~ DA DA DALI ECG Green bulb Y-connector Pushbutton coupler or additional EASY components ~ DA DA DALI ECG Blue bulb ~ DA DA DALI ECG White bulb Y-connector EASY PC Kit or additional EASY components Max. total line length 100 m IV 2009 11

Operation Operation Remote control Note: These instructions primarily describe the operation via the DALI EASY RMC remote control. To operate via an EASY PB Coupler, see the separate instructions for the EASY PB Coupler. Display Channel pushbutton: Ch1 Ch2 Ch3 Ch4 Start / Time+ Stop / Time - OSRAM Infrared transmitter Scene 1 Scene 2 Scene 3 Scene 4 On/Off Dimming ON DIP 1 2 3 4 DIP switch Note: Additional information on the remote control can be found in the separate operating instructions of the DALI EASY RMC. 12 IV 2009

Operation Activating the operating modes The lighting control mode is always active. The sequencer mode and daylight simulation are activated via the DIP switches in the battery compartment of the remote control. Activated operating modes Lighting control mode only Sequencer mode (incl. lighting control mode) Daylight simulation (incl. lighting control mode) Switching on and off the luminaires DIP switch setting DIP switch 3 = OFF DIP switch 4 = OFF DIP switch 3 = OFF DIP switch 4 = ON DIP switch 3 = ON DIP switch 4 = OFF ON ON ON Via short press. All LEDs: On/Off dimming button.. LEDs (channels 1 to 4): Ch1 to Ch4 buttons. Changing the brightness manually Via long press. Each repeated long key press causes a toggle between increased brightness and decreased brightness. All LEDs: On/Off dimming button.. LEDs (channels 1 to 4): Ch1 to Ch4 buttons. Note: The LEDs of a group are all connected to the same output channel and therefore have the same brightness. IV 2009 13

Operation Storing and calling up a lighting scene Scene 1 to Scene 4 buttons. Proceed as follows to store lighting scenes: Step Task 1 Set the brightness of the luminaire group; see "Changing the brightness manually". 2 Press the desired button for at least 3 seconds. 3 Confirmation: luminaires flash. To call up a lighting scene: Via short press. Disabling scene storage Storing of scenes can be disabled by means of the DIP switches in the remote control or in the pushbutton coupler. Storing scenes Remote control Pushbutton coupler Disabled DIP switch 2 = OFF DIP switch 1 = OFF Enabled DIP switch 2 = ON DIP switch 1 = ON Starting and ending the sequencer mode Via short press. To start and continue the sequencer mode: Start/time+ button To stop the sequencer mode: Stop/time button To end the sequencer mode: Ch1 to Ch4, Scene 1 to Scene 4 or On/Off dimming. 14 IV 2009

Operation Setting the fade and cycle time Set the fade time for the sequencer mode and the cycle time for the daylight simulation. To increase the time: Start/Time+ button To decrease the time: Stop/Time button Proceed as follows: Step Task 1 Press the button for at least 3 seconds. The time is shown on the display; see below. 2 Single steps: Short press Fast forward: Long press Operating mode Display Interval Sequencer mode (fade time) Effect Lighting Tenths of a second Wellness Long Time Daylight simulation (cycle time) Seconds Minutes Hours Example of a sequence Brightness Scene 1 Scene 2 Scene 3 Red: Green: Blue: Fade time Hold time* Time *The hold time is automatically set to 25% of the set fade time. Scene 1: Scene 2: Scene 3: Scene 4: Ch1 (red) = max.; Ch2,Ch3,Ch4 = min. Ch2 (green) = max; Ch1,Ch3,Ch4 = min. Ch3 (blue) = max.; Ch1,Ch2,Ch4 = min. Ch1...Ch4 = off (is skipped) IV 2009 15

Operation Example of a daylight simulation Cycle time 12h. Clock-controlled switch-on at 8 a.m. Brightness 90% 80% 50% Scene 1 Scene 2 Scene 3 Scene 4 Cycle time 8:00 12:00 16:00 20:00 Time Troubleshooting If you cannot remedy the fault, please contact the Customer Service department of the luminaire manufacturer. Fault Cause Remedy Luminaire does not function Control unit does not respond to the remote control Control unit does not respond to the external pushbutton Luminaire does not react as expected to the press of a button Sequence in the masterslave mode is not synchronous No mains voltage present. Illuminant defective. No mains voltage present. Illuminant defective. Remote control batteries are too weak. Remove control is outside the range of the infrared receiver. Wrong IR coding. Infrared receiver is exposed to direct light. No mains voltage present. Illuminant defective. Button was pressed too long or too short. No mains voltage present. Slaves have already been programmed and have their own scenes. Slave bridges are missing. Check the mains supply fuses. Replace illuminant. Check the mains supply fuses. Replace illuminant. Check the display. Replace the batteries if necessary. Reduce the distance. Check the IR coding. Shade the receiver or select another installation location. Check the mains supply fuses. Replace illuminant. See "Operation". Check the mains supply fuses. Perform a reset and create the sequence again. Insert the bridges. 16 IV 2009

Appendix Appendix Technical data For LED modules Operating voltage Permissible voltage fluctuations Line current, nominal Output voltage Max. module wattage With respect to the output conditions: 1 x LINEARlight Colormix Flex (4m), 7 x LINEARlight Colormix, etc. 220-240 V AC / 50-60 Hz 198-264 V AC 0.33 A @ 230 V 24 V DC 60 W, distributed over all outputs (60 W on only one output is also possible) Power factor PF > 0.95 Max. losses Control signal 8 W @ 230 V Digital EASY signal via 4-pin RJ-11 modular connection (4p4c) Master-slave connection Max. 100 m total line length Max. 50 m to pushbutton coupler Max. 1 master and 15 slaves are connectable Do not route the master-slave connections together with the power supply or LED lines. Max. number of connectable components Dimming mode 4 EASY IR sensors 1 EASY pushbutton coupler 1 EASY USB adapter PWM (300 Hz) Dimming range 0-100 % Operating temperature -20 C +50 C EASY interface Secondary side Max. secondary line length Dimensions (L x W x H) 4-pin modular connection Screw terminals 10 m 220 x 46.2 x 43.6 mm IV 2009 17

Appendix Applicable standards Safety UIEC 61347 Performance IEC 62384 Radio interference EN 55015, EN 55022 Harmonic content IEC 61000-3-2 Immunity IEC 61547 Dimensions Conformity with the relevant EU directives is confirmed by the CE symbol. 18 IV 2009

IV 2009 OT_EASY_60_II_ma0904en_we1.01.indd OSRAM GmbH Kunden Service Center Customer-Service-Center (CSC) Steinerne Furt 62 86167 Augsburg Germany Tel : +49 (0) 1803 677-200 (kostenpflichtig / charges apply) Fax.: +49 (0) 1803 677-202 www.osram.com www.osram.de 40083211877966 4008321187796