Errata. Title & Document Type: HP 4396A Network/Spectrum Analyzer Operation Manual

Similar documents
E5070B/E5071B Adjustment Program. <Agilent Service Center Use Only> Operation Manual. First Edition. Agilent Part No.

E5071C Adjustment Program. <Agilent Service Center Use Only> Operation Manual. Second Edition. Agilent Part No. N/A

Agilent E5100A/B Network Analyzer. HP Instrument BASIC Users SERIAL NUMBERS. This manual applies directly to instruments with serial

Agilent 8703A. Lightwave. Configuration Guide nm or 1550 nm 130 MHz to 20 GHz modulation bandwidth. Example Configuration:

Enables Auto-complete of ENA Series Commands when Writing Code on an External PC

HP 8752C and HP 8753D Network Analyzers. Configuration Guide. System Configuration Summary. 300 khz to 1.3, 3 or 6 GHz 30 khz to 3 or 6 GHz

ATEC (2832) Models 8757A, 85027A/B/C, 85020A/B

Awareness Brochure. New Standards For Precise Component, Semiconductor and Material Measurements. Expanded LCR Meter Performance to 1 GHz!

Agilent Technologies E6385A Lucent AMPS Base Station Test Software. User s Guide

Agilent 4285A Precision LCR Meter (Including Option 001, 002, 201, 202, 301) Maintenance Manual

Agilent ENA RF Network Analyzer

Software User s Guide


Agilent E5052A Signal Source Analyzer. Service Guide. Sixth Edition

About this Manual. Support for Your Product

Advanced Test Equipment Rentals ATEC (2832) Manual Supplement. Agilent E5070B/E5071B ENA Series RF Network Analyzers

Agilent RF Network Analyzers PNA Series

Writing Control Software for the HP 83236A/B Product Note

Agilent 4263V Option 001 N/M/DCR Retrofit Kit for Agilent 4263B. Retrofit Manual. Second Edition. Manufacturing No

LadyBug Technologies LLC Automated PowerSensor+ Field Certification Procedure

MET/BASE Version 6.0 July What s New in V6.0? 32-Bit Software. Measurement Uncertainty Compliance. New Drivers

Agilent E5072A ENA Series Network Analyzer

Read or Write Trace Data

Quick Start Guide Agilent Technologies 14565A Device Characterization Software for Windows 98, Windows NT 4.0, Windows 2000 and Windows XP

Field Calibration Software

Installation Note. Agilent Technologies ESA-E Series Spectrum Analyzers High Stability Frequency Reference (Option 1D5) Retrofit Kit

R A D I O N I C S. READYKEY K6100 Readykey for Windows. PC Specification Datasheet

HP E4916A Crystal Impedance Meter

HP 4339B High Resistance Meter. User's Guide. HP Part No Printed in JAPAN July Third Edition

Control an External Measurement Instrument

PN3048 Phase Noise Software

Installation Note. Agilent ESG and ESG-D Series Signal Generators Add Option 1E5 Upgrade Kit Kit Part Number E

E5092A Configurable Multiport Test Set

Infiniium X / L- Series Oscilloscopes

About this Manual. Support for Your Product

Infiniium Q- Series Oscilloscopes

OP WINEDIT Configuration Software. Manual Number OP WINEDIT M

Contents. HP E1586A Rack Mount Terminal Panel User s Manual

Agilent. E5092A Configurable Multiport Test Set. Configuration Guide

Agilent E5061B Network Analyzer. Configuration Guide

The UFC-6000 can measure the frequency of a signal from 1 to 6000 MHz. Mini-Circuits

Installation Note. Source Attenuators and Bias Tees Upgrade Kit. For E8362B/C PNA Series Microwave Network Analyzers. Network Analyzer Model Number

Agilent Noise Source Calibration Using the Agilent N8975A Noise Figure Analyzer and the N2002A Noise Source Test Set. Technical Overview

E2625A Communication Mask Test Kit E2698A Ethernet Masks

Agilent ENA-L RF Network Analyzers

Quick Setup & Getting Started

Agilent Technologies 16700B-Series Logic Analysis Systems. Installation Guide. Publication number November 2002

Optical Spectrum Analyzer AQ6330. Full featured optical spectrum analyzer with compact and lightweight design

Keysight 42941A Impedance Probe Kit

E5504B E18 Phase Noise Measurement System

Installing the A4505A PCI Module Upgrade. HP Part No. A Edition E0297 Printed in U.S.A.

Errata. Title & Document Type: 8514B S-Parameter and 8512A Reflection Transmission Test Sets Manual Manual Part Number:

Service Guide. Publication Number March Agilent Technologies, Inc Infiniium A-Series Oscilloscopes

Operating and Service Manual

PSA-Series Spectrum Analyzers

One (1) acoustic and three (3) seismic channels. Three (3) component velocity output. All units are interchangeable with accuracy within two percent.

HP / HP HPIB Driver Installation and Troubleshooting ChemStation Version A.07.0x- A.08.0xon Windows NT

Getting Started: Creating and Executing a Test Setup. Step 1: Cable the Hardware Connections. Step 2: Connect the HP4145 Instrument Driver

Agilent Microwave Sweep Oscillator and Network Analyzer Instrument Security

About this Manual. Support for Your Product

User's and Service Guide HP 87050A Option H47

N5532B Sensor Module User s and Service Guide

S3101 Cable & Antenna Tester Datasheet

Interface Modules for HP Series Instruments. I/O Function Guide. Copyright Hewlett-Packard Company All rights reserved

Agilent. E5071C Network Analyzer 9 khz to 4.5/6.5/8.5 GHz 100 khz to 4.5/6.5/8.5 GHz (with bias tees) 300 khz to 14/20 GHz (with bias tees)

The HP Server Console Switch with Virtual Media is backwards compatible with all HP Cat5 based Server Console Switches and interface adapters.

About this Manual. Support for Your Product

Fluke Metrology Software

Datalogging IAQ Meter Instruction Manual

Getting Started. HP Business PCs

Agilent Technologies 1680/90-Series Logic Analyzer. Service Guide. Publication number October 2005

MICRO CRAFT CORPORATION

Agilent Noise Source Calibration Using the Agilent N8975A Noise Figure Analyzer and the N2002A Noise Source Test Set. Product Note

Portable PIM Analyzer

Keysight Technologies E5080A ENA Vector Network Analyzer. E5092A Configurable Multiport Test Set

Looking for a simple and intuitive solution that allows you to access and manage servers across your entire network?

Keysight MOI for USB Type-C Cable Assemblies Compliance Tests Using Keysight M937XA Multiport PXIe VNA

Operator Quick Guide ORBISPHERE 3650

University of Illinois Department of Electrical and Computer Engineering ECE 451 Automated Microwave Measurements Laboratory

Agilent 70612B K18 Switch Matrix

SERIES MS462XX VECTOR NETWORK MEASUREMENT SYSTEM VERIFICATION KITS OPERATION AND MAINTENANCE MANUAL

HP ProLiant ML370 G4 Storage Server

The TPU-2000R unit comes enclosed in a metal case. Follow the instructions and diagrams in this section to install the TPU-2000R.

CVI SPECTRAL PRODUCTS. 111 Highland Drive Putnam CT, (860) SM32Pro

Versatility, performance, and a great low price

Agilent Technologies 11667A DC to 18 GHz Power Splitter

service handbook chapter

Keysight E4991B Impedance Analyzer

HP 8714B Calibration

INTERFACE BUS. HEWLETT [hpl PACKARD. Versatile interconnect system for instruments and controllers

Security Features and Volatility Documentation

TN Vector Network Analyzer Calibrations and Their Effect on Measurement Results. Bernie McDermott. May 2010

Installation Note. Agilent PSA Series Spectrum Analyzers Secure Memory Erase, Option 117

About this Manual. Support for Your Product

Keysight Technologies N5394A DVI Electrical Performance Validation and Compliance Software for Infiniium Oscilloscopes. Data Sheet

Agilent 7061A and 87130A Switch Attenuator Drivers

ABCDE. HP Part No. E Printed in USA November Edition 3 E1195

HP G1701BA Productivity ChemStation Software. Installation Manual

Technical Specifications May 2003

Keysight Technologies E5071C Network Analyzer

Transcription:

Errata Title & Document Type: HP 4396A Network/Spectrum Analyzer Operation Manual Manual Part Number: 04396-90106 Revision Date: July 1999 HP References in this Manual This manual may contain references to HP or Hewlett-Packard. Please note that Hewlett-Packard's former test and measurement, semiconductor products and chemical analysis businesses are now part of Agilent Technologies. We have made no changes to this manual copy. The HP XXXX referred to in this document is now the Agilent XXXX. For example, model number HP8648A is now model number Agilent 8648A. About this Manual We ve added this manual to the Agilent website in an effort to help you support your product. This manual provides the best information we could find. It may be incomplete or contain dated information, and the scan quality may not be ideal. If we find a better copy in the future, we will add it to the Agilent website. Support for Your Product Agilent no longer sells or supports this product. You will find any other available product information on the Agilent Test & Measurement website: www.tm.agilent.com Search for the model number of this product, and the resulting product page will guide you to any available information. Our service centers may be able to perform calibration if no repair parts are needed, but no other support from Agilent is available

HP 4396A Network/Spectrum Analyzer Performance Test Program (PN: 04396-65001) Operation Manual ABCDE HP Part No. 04396-90106 Printed in JAPAN July 1999

Notice The information contained in this document is subject to change without notice. This document contains proprietary information which is protected by copyright. All rights are reserved. No part of this document may be photocopied, reproduced, or translated to another language without the prior written consent of the Hewlett-Packard Company. Hewlett-Packard Japan, LTD. Kobe Instrument Division 1-3-2, Murotani, Nishi-ku, Kobe-shi, Hyogo, 651-2241 Japan c Copyright 1993,1999 Hewlett-Packard Japan, LTD.

Contents 1. General Information Introduction................................. 1-1 Initial Inspection............................... 1-1 Making Working Copies............................ 1-2 Required Tools................................ 1-2 Hardware Requirements.......................... 1-2 Software Requirements.......................... 1-2 Test Equipment............................... 1-3 Calibration Data Required for Step Attenuator................ 1-4 2. Preparation Test Equipment Conguration........................ 2-1 System Setup................................ 2-2 3. Operation Keyboard and Mouse Operation........................ 3-1 Program Execution............................. 3-2 Built-in Calibration Data Editor........................ 3-3 Program Flow................................ 3-4 Main Program Flowchart.......................... 3-4 Built-in Calibration Data Editor Flowchart.................. 3-6 Contents-1

Figures 2-1. Performance Test Hardware Setup..................... 2-2 3-1. Performance Test Program Flowchart.................... 3-4 3-2. Built-in Calibration Data Editor Flowchart.................. 3-6 Tables 1-1. Required Equipment............................ 1-2 1-2. Required Language Extensions....................... 1-2 1-3. Recommended Test Equipment....................... 1-3 1-4. Calibration Data Required for HP 8496A/G................. 1-4 1-5. Calibration Data Required for HP 8494A/G................. 1-5 Contents-2

1 General Information Introduction The HP 4396A Performance Test Program (P/N: 04396-65001) is written in HP BASIC, designed to minimize the test time, and helps eliminate human error while performance testing the HP 4396A Network/Spectrum Analyzer. When executing the program, the computer displays the test instructions, and controls the HP 4396A under test and the related test equipment. This performance test program has the \Built-in Calibration Data Editor" which edits and stores the standards' calibration data needed in the tests. Initial Inspection The Performance Test Program for HP 4396A has been carefully inspected before being shipped from the factory. Verify that the shipping container contains the following: 2 ea. of 3-1/2 inch diskettes Operation Manual (this book) The diskettes should contain the following. Check the contents of the diskette using your computer CAT command: Filename TEST4396A SUBT4396A Description Main Program Subprogram CSUBS Compiled Utilities for BASIC 5.13 CSUBS6 TE_T4396A Compiled Utilities for BASIC 6.2 and above Test Equipment Conguration Program General Information 1-1

Making Working Copies HP 4396A Copy the contents of the performance test program diskette to a working diskette or to the hard disk to prevent accidental deletion or destruction of the program les. Use the working diskettes or the hard disk, and store the original diskette in a safe place. Note Make an exclusive directory for this program and copy the les of the diskette into the directory when you use a hard disk. Required Tools Hardware Requirements Table 1-1 lists the equipment required for executing the programs. Table 1-1. Required Equipment Equipment Requirements Recommended Models Qty. Computer No Substitute HP 9000 series 200 or 300 1 1 RAM 4 MBytes Operating System BASIC 5.1 or higher HP 98616A 1 Flexible Disk Drive Dual 3-1/2 inch Drive HP 9122C 1 Printer HP-IB Printer HP 2225AJ 1 1 Excluding the HP 9826A Software Requirements Table 1-2 lists the required language extensions to be used with the performance test program. If you already have a pre-congured BASIC system, you can verify if it contains all the required binaries by typing LIST BIN. Table 1-2. Required Language Extensions Name CLOCK EDIT GRAPHX MAT CRTA ERR HPIB MS Description Clock List and Edit Graphics Extensions Matrix Statements Alpha CRT Driver Error Messages HPIB Interface Driver Mass Storage Name CRTX FHPIB IO PDEV CS80 GRAPH KBD Description CRT Extensions Fast Disc Interface Driver I/O Program Development CS80 Disc Driver Graphics Keyboard Extensions 1-2 General Information

HP 4396A Test Equipment Table 1-3 lists the required equipment to perform the performance test. Table 1-3. Recommended Test Equipment Equipment Name Model or HP Part Number Qty Frequency Counter HP 5343A Opt. 001 or HP 5334B Opt.010 or 1 HP 5335A Opt.010 1 Frequency Standard 2 HP 5061B 1 Spectrum Analyzer HP 8566A/B 1 Network Analyzer HP 8753A/B/C 1 Power Meter HP 436A Opt. 022 or HP 437B or HP 438A 1 Power Sensor HP 8482A 1 Power Sensor HP 8481D 1 Function Genarator HP 3325A 1 Signal Generator 3 HP 8663A or HP 8642B 2 Step Attenuator 4 HP 8496A/G Option 001 and H60 5 1 Step Attenuator 4 HP 8494A/G Option 001 and H60 6 1 Attenuator/Switch Driver HP 11713A 7 1 50 Type-N Calibration Kit HP 85032B 1 T/R Test Set HP 85044A 1 50 MHz Low Pass Filter PN 0955-0306 1 50 termination, type-n(m) HP 909C Opt 012 or part of HP 85032B 8 3 6 db Fixed Attenuation, 50 HP 8491A Opt 006 2 6 db Fixed Attenuation, 50, VSWR 1.015 HP 8491A Opt 006 & Opt H60 9 2 Two-way Power Splitter HP 11667A 1 N(m)-N(m) cable, 50 HP 11500B or part of HP 11851B 10 4 RF cable kit HP 11851B 1 1 Option 001 or 010 (optional time base) is not required, when a frequency standard in Table 1-3 is available. 2 Required for testing an analyzer equipped with Option 1D5 (High Stability Frequency Reference). 3 The \HPxxxx 2" type model number is assigned to the \Signal Generator 2", while the nomal \HPxxxx" is used for the \Signal Generator 1". This makes us possible to use two signal generators of the same model. 4 Calibration values at 50 MHz are required in the tests. See the Calibration Data Required for Step Attenuators later in this chapter. 5 An HP 8496A/G step attenuator with required low VSWR ( 1.02) can be purchased by specifying option H60. 6 An HP 8494A/G step attenuator with required low VSWR ( 1.02) can be purchased by specifying option H60. 7 Required when an HP 8494G or HP 8496G step attenuator is used in the tests. 8 The HP 85032B includes a type-n(m) 50 termination. 9 An HP 8491A Opt. 006 xed attenuator with required low VSWR ( 1.015) can be purchased by specifying Opt. H60. 10 The HP 11851B includes three N(m)-N(m) cables of 61 cm and a N(m)-N(m) cable of 88 cm. General Information 1-3

HP 4396A Table 1-3. Recommended Test Equipment (continued) Equipment Name Model or HP Part Number Qty BNC(m)-BNC(m) cable, 61 cm, 50 PN 8120-1839 1 BNC(m)-BNC(m) cable, 122 cm, 50 PN 8120-1840 2 BNC(f)-BNC(f) adapter, 50 PN 1250-0080 1 BNC(f)-SMA(f) adapter, 50 PN 1250-0562 1 Tee BNC(m)-(f)-(f) adapter, 50 PN 1250-0781 1 N(m)-N(m) adapter, 50 PN 1250-1475 1 N(m)-BNC(f) adapter, 50 PN 1250-1476 1 N(f)-BNC(m) adapter, 50 PN 1250-1477 1 APC 3.5(m)-APC 3.5(f) adapter, 50 PN 1250-1866 1 APC 7-N(f) adapter, 50 HP 11524A or part of HP 85032B 1 1 1 The HP 85032B includes two APC 7-N(f) adapters. Calibration Data Required for Step Attenuator The six performance tests listed below measure the analyzer's performance against a known standard (the attenuation values at a frequency 50 MHz of the HP 8496A/G and HP 8494A/G step attenuators). 3. Non-Sweep Power Linearity Test 4. Power Sweep Linearity Test 10. Magnitude Ratio/Phase Dynamic Accuracy Test 14. Amplitude Fidelity Test 15. Input Attenuator Switching Uncertainty Test 18. IF Gain Switching Uncertainty Test These tests require the calibrated values of the attenuators listed in Table 1-4 and Table 1-5. Enter these attenuation values (referenced to 0 db setting) at the beginning of the program with following instructions. See \Built-in Calibration Data Editor" in Chapter 3 for details. Table 1-4. Calibration Data Required for HP 8496A/G Frequency Attenuation Uncertainty 50 MHz 10 db 0.0060 db 20 db 0.0060 db 30 db 0.0066 db 40 db 0.0090 db 50 db 0.0165 db 60 db 0.0197 db 70 db 0.0272 db 1-4 General Information

HP 4396A Table 1-5. Calibration Data Required for HP 8494A/G Frequency Attenuation Uncertainty 50 MHz 2dB 0.007 db 4dB 0.007 db 6dB 0.007 db 8dB 0.007 db 10 db 0.007 db The calibration uncertainty is the primary source of measurement error in performance tests. The measurement uncertainties listed in the performance test record are valid only when the uncertainty of the step attenuation data satises that given in the third column of Table 1-4 and Table 1-5. The calibration of step attenuators, HP 8496A/G and HP 8494A/G, are available at Hewlett-Packard. For information about the calibration and the available uncertainties, contact your nearest Hewlett-Packard service center. General Information 1-5

2 Preparation Test Equipment Conguration This procedure is used to select the equipment and to set their HP-IB addresses. When you perform the Performance Test Program at the rst time, perform this Equipment Conguration Program to select the equipment and the HP-IB address. After that, only when you want to change the equipment or the HP-IB address, perform this program. 1. Set the MSUS (Mass Strage Unit Specier) to the working directory or drive using the MSI command. 2. Load the Test Equipment Conguration Program, \TE T4396A" by pressing LOAD "TE_T4396A" 4Return5 (or 4ENTER5) key. 3. Execute the program by pressing RUN, and follow the instructions on the computer's screen. 4. The BDAT les which contain the test equipment conguration information will be created in the working directory / drive. Preparation 2-1

HP 4396A System Setup The system setup is shown in Figure 2-1 Figure 2-1. Performance Test Hardware Setup 2-2 Preparation

3 Operation This chapter describes a program owchart, and how to operate the program. Keyboard and Mouse Operation The menus in \TEST4396A" use a window format. It supports keyboard and mouse operations. The operations are as follows. Keyboard Operation 1. Press 485/495 cursors until your preference is highlighted. 2. Choose the highlighted item by pressing 4Return5 or 4Select5 (4ENTER5 or 4EXECUTE5). 3. If NNNNNNNNNNNNNN QUIT or NNNNNNNNNNNNNN EXIT is displayed in a menu, select one of these to exit the menu. Otherwise, press 45 (or 4CONTINUE5) key to exit. When you exit menus, the program displays next menu. Note Press 4?5 to access on-screen help information for the selection you have highlighted. Help information appears in a display window. Press 4Return5 or 4Select5 (4ENTER5 or 4EXECUTE5) to turn o the help screen. Mouse Operation 1. Slide the mouse up or down until your preference is highlighted. 2. Choose the highlighted item by pressing left-hand button on the mouse, or slide the mouse to the right. 3. If NNNNNNNNNNNNNN QUIT or NNNNNNNNNNNNNN EXIT is displayed in a menu, select one of these to exit the menu. Otherwise, slide the mouse to the left to exit. When you exit menus, the program displays next menu. Note Press the right-hand mouse button to access on-screen help information for the selection you have highlighted. Help information appears in a display window. Press the left-hand mouse button to turn o the help screen. Operation 3-1

HP 4396A Program Execution Perform the following steps to start the performance test program. Note In the program, the HP 4396A under test is referred as \UUT". Note Perform the Test Equipment Conguration prior to execution. Refer to \Test Equipment Conguration" in Chapter 2. Main Program Instruction 1. Turn on the computer and bring up the BASIC system. Refer to the Table 1-2 for the required language extensions. 2. Set the Mass Storage Unit Specier to the drive/directory where the adjustment program exists using the MSI command. 3. Load the program, \TEST4396A" by pressing LOAD "TEST4396A" 4Return5 (or 4ENTER5). 4. Execute the program by pressing RUN. 5. The copyright will be displayed on the computer's screen. Press any key to continue. 6. The UUT conguration window \UUT: HP4396A" will be opened. Enter the UUT (the HP 4396A under test) conguration (serial number, HP-IB address, environment, and line frequency), and press 45 (or 4CONTINUE5) key to continue. 7. The program will ask \Where should Test Reports be printed?". Select NNNNNNNNNNN CRT, NNNNNNNNNNNNNNNNNNNNNNN PRINTER, or NNNNNNNNNNNNNNNNNNNNNNNNNNNNN NO OUTPUT. Note If the performance test record is necessary, then select NNNNNNNNNNNNNNNNNNNNNNN PRINTER and connect a printer which is addressed 701 to the computer by HP-IB cable. 8. The used equipment list will be displayed. Select NNNNNNNNNNNNNNNNNNNNNNNNNN CONTINUE to go to next step, or NNNNNNNNNNNNNNNNN PRINT to print the used equipment list to the printer. 9. The used accessory list will be displayed. Select NNNNNNNNNNNNNNNNNNNNNNNNNN CONTINUE to go to next step, or NNNNNNNNNNNNNNNNN PRINT to print the used accessories list to the printer. 10. The \TEST LIST" menu will be opened. Each test can be selected using 485/495 cursors and 4Return5 (or 4ENTER5) key, or pressing 45 (or 4CONTINUE5) key to exit the program. Note INITIAL SETUP will be performed automatically when you select any other test before performing INITIAL SETUP. Note INITIAL SETUP includes the Built-in Calibration Data Editor and the Standard Selection screen. Refer to the next section for instruction of the Built-in Calibration Data Editor. 3-2 Operation

HP 4396A 11. The program will invoke the Calibration Data Editor. Select the calibration standard's serial number to be used in the test among the listed serial numbers. Built-in Calibration Data Editor This section provides the instructions for the Built-in Calibration Data Editor. Built-in Calibration Data Editor Instruction 1. The window \Enter the CAL FACTOR volume Msvs" will be opened. Enter the MSVS (Mass Storage Volume Specier) which the calibration data will be stored in. Note The directory must be already exist before executing the performance test program. Create directory rst which the calibration data should be stored in. 2. The menu for selecting ADD, EDIT or DELETE the standard will be opened. Select NNNNNNNNNNN ADD for adding the new standard data, NNNNNNNNNNNNNN EDIT for editing an existing standard data, or NNNNNNNNNNNNNNNNNNNN DELETE for deleting an existing standard data. Note The NNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNN SERIAL NUMBER eld cannot be modied when editing the calibration data. Operation 3-3

Program Flow HP 4396A Figure 3-1 shows the performance test program owchart. The following information gives a brief explanation for each menu item. Figure 3-2 shows the Built-in calibration data editor owchart. Main Program Flowchart Figure 3-1. Performance Test Program Flowchart 3-4 Operation

HP 4396A UUT Conguration Input Destination of Test Report Selection Equipment / Accessories Conrmation TEST LIST Menu Built-in Calibration Data Editor Standards Selection Performing Each Test Test Report Output Input the UUT serial number, HP-IB address, installed options, environment, and line frequency. Select where the Test Report will be output. The output medium can be selected as NNNNNNNNNNN CRT, NNNNNNNNNNNNNNNNNNNNNNN PRINTER,or NNNNNNNNNNNNNNNNNNNNNNNNNNNNN NO OUTPUT. Conrm equipment and accessories are correct. If necessary, select NNNNNNNNNNNNNNNNN PRINT to print out the list. Otherwise, select NNNNNNNNNNNNNNNNNNNNNNNNNN CONTINUE to continue. Each test can be selected by using 485/495 cursors and 4Return5 (or 4ENTER5) key. If necessary, you can invoke the Built-in Calibration Data Editor by selecting \INITIAL SETUP". Press 45 (or 4CONTINUE5) key to quit the program. Input standards' calibration data which are needed to perform the performance test. Select the standards' serial numbers used in the performance test. This list must be lled before performing each test. Press 45 (or 4CONTINUE5) key to exit this screen. Each test can be selected in the `TEST LIST' Menu. Outputs the Test Report to the medium that was selected at \Destination of Test Report Selection". Operation 3-5

HP 4396A Built-in Calibration Data Editor Flowchart Figure 3-2. Built-in Calibration Data Editor Flowchart 3-6 Operation

HP 4396A Power Sensor or Step Attenuator Entering the MSVS to store the Calibration Data Select NNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNN POWER SENSOR or NNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNN STEP ATTENUATOR. Selecting NNNNNNNNNNNNNN EXIT or pressing 45 (or 4CONTINUE5) key quits the Built-in Calibration Data Editor. Enter the MSVS (Mass Storage Volume Specier) which the calibration data will be stored in. For example: :CS80,702,1 /CAL_FACTORS:REMOTE Flexible disk based system SRM based system Default MSVS is current MSVS. Press 45 (or 4CONTINUE5) key to exit this screen. Add / Edit / Delete Menu Entering / Editing the Tag Data Existing Data Selection Editing the Calibrated Values You can select NNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNN NEW CAL FACTOR FILE to add the new calibration data, or NNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNN EDIT CAL FACTOR FILE to modify the existing calibration data, or NNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNN PURGE CAL FACTOR FILE to delete the existing calibration data. Enter / edit the serial number, cal due date, trace number, and press 45 (or 4CONTINUE5) key to exit this screen. A list of existing data is displayed. Select one of the data to be edited / deleted using 485/495 cursors, and press 4Return5 (or 4ENTER5) key to go to next step. A screen that corresponds to the Calibration Report is displayed. You can select the eld that you want to edit by using 485/495 cursors, and pressing 4Return5 (or 4ENTER5) key to start modify. Each value is adjusted by 485/495 cursors. Press 45 (or 4CONTINUE5) key to back to previous screen. Operation 3-7