Emergency Luminaire for Fluorescent Lamps Series EXLUX 6009

Similar documents
Linear Luminaire with LED Series EXLUX 6002/1 Version IIB+H2

Linear Luminaire with LED Series 6012/5

Linear Luminaire with LED Series 6412/5

Terminal Boxes Series 8118

Tubular Light Fitting with LED Series 6036

2.2. Ex-Linear LED light fittings. ellk/m 92 LED 400/800 / ellk/m 92 LED 400/800 V-CG-S / NE / NIB-HT / NIB-CSA (Zone 1, 2, 21, 22)

SolConeX extra-low voltage flange socket

Grounding Monitoring Device Series 8485

Load Disconnect Switches and Motor Switches

Grounding Systems / Ground Monitoring Device Series 8146/5075 and 8125/5071

Grounding Monitoring Device Series 8485

2.3. Ex-Linear light fittings for fluorescent lamps. ellk W 58 W / ellm W 36 W (Zone 1, 2, 21, 22)

Position Switches Series 8070

Cable End Boxes Series 8146

Control Buttons / Switches for Panel Mounting Series 8003

SolConeX Wall-Mounted Socket, 16 A

Throughwiring. single-ended. twin-ended

5 Fieldbus Technology

Operating and monitoring systems Thin Client SERIES 500 Device platform EAGLE PM ET-556-TX

Miniature Circuit-Breaker IEC Series 8562

FELED Series Nonmetallic LED Luminaires Standard and Emergency Battery Back-Up, Increased Safety

ATX FELED Series Nonmetallic LED Luminaires Standard and Emergency Battery Back-Up, Increased Safety

XLF. Ex d. - Zones 1, 2, 21, 22 - Obstruction warnings - Stroboscopic lights - Single or double fixtures - Low wind resistance

Digital Output Module 4-Channel Version for Zone 1 Series 9475/

Sicherheit, auf die Sie sich verlassen können

Operating and monitoring systems Panel PC SERIES 400 Device platform EAGLE PM ET-436-TX

Operating and monitoring systems Operator Interface SERIES 300 Device platform EAGLE PM MT-336-FX

Operating and monitoring systems Panel PC SERIES 400 Device platform EAGLE PM MT-436-TX

SKX 12 SKX 15. Zone. make your work surroundings safer IP 66

M C. Ex d M-0... control, monitoring and signalling devices

Page 1 of 5. Increased Safety, Encapsulation and Dust

Providing flexible power supply and signal connection there, where it is needed even in hazardous areas for the Zones 1and 2.

Control Switches for Panel Mounting Series 8003

Micro Limit Switch Series 8064

Product manual plug, sockets and coupler 16 A.- Z0251

Supplementary Components WirelessHART products

Digital Output Module 8-Channel Version for Zone 1 Series 9475/

GRP Flameproof Visual Signal Xenon or Steady LED

Digital Output Module 4-Channel Version for Zone 1 Series 9475/

Viamaster LED Series Luminaires For NEC and CEC Governed Hazardous Locations

Junction Boxes & Enclosures JBEP and ECEP Series: Undrilled Fiberglass Reinforced Polyester Enclosures Increased Safety

Ground Monitoring Device Series 8485

Digital Output Module 8-Channel Version for Zone 2 Series 9475/

Viamaster LED Series Luminaires For ATEX and IECEx Governed Hazardous Locations

Digital Output Module 8-Channel Version for Zone 2 Series 9475/

Ex Junction Boxes & Control Stations

Operating and monitoring systems Operator Interface SERIES 300 Device platform EAGLE OS ET-306-FX

11W & 22W: Ex d e mb IIC T6 Gb, Ex tb IIIC T85 C Db II 2GD ABS Assessed: #11-LD PDA

Ex-control switch Typ 292 without and Typ 293 with measuring instrument

4 Remote I/O. Digital Output Module 8-Channel Version Series 9475/ from Rev. F

4 Remote I/O. Digital Output Module 8-Channel Version Type 9475/ from Rev. F

Operating and monitoring systems Operator Interface SERIES 300 Device platform EAGLE OS MT-316-TX

Control Stations & Switches: Switches, Circuit Breakers and "Break Glass" Call Points SWE Series: 16 and 20 A Switches Increased Safety

Temperature Measurement SITRANS TS300

Ethernet CPU Module & Power Module for Zone 1 / Div. 1 Series 9441/12 and 9444/12

Industrial Light Fittings. for harsh and arduous environment

CPU module for zone 2 Series 9442/35

IECEx Certificate of Conformity

VersaPro Non-Metallic Fluorescent

Technical Data. General specifications. Rated operating distance s n 3 mm

74 PS range Push-buttons, selectors and indicators Ø 22mm

Technical data sheet Fila LED - FT0110-A4-P FILA LED

IECEx Certificate of Conformity

Pneumatic Control/Feedback

Termination Board FC-GPCS-SAI16-PF. Features. Assembly. Function. Connection. SAI-1620m HART 24 V DC (I), 24 V DC (II) Fault. Zone 0, 1, 2 Div.

Pneumatic Control/Feedback

TO ALL OUR CUSTOMERS 1. NEW ADVANCE GRP SERIES - 16A-32A-63A INTERLOCKED SOCKETS IN THERMOSET TING MATERIAL

Technical information

SIZE 1, 2 AND 3 POLYAMIDE PRE-DRILLED CONTROL STATIONS

Ex emergency pull-wire switches Ex ZS 71

Operating Manual / IEC. Explosion-Proofed Junction Boxes, Polyester. Wallücker Bahndamm 7 DE Kirchlengern

modular enclosure MUREVA, IP65 weatherproof & versatile enclosures aesthetics multi-functional evolutionary ergonomics and time saving security

Standard enclosure for Remote I/O Series 8150

A.A.G. Stucchi TRACK LIGHTING SYSTEM

Level Measurement Continuous level measurement - Ultrasonic transducers

AllPro Hazardous/Corrosive Area Fluorescent

CombiView DFON Graphical display

ERNG-X. Description. Applications. ERNG-X Specifications DERNG2108X012

Safety switches with separate actuator

EX-PROOF HD CAMERA IN A COMPACT DESIGN EC-910-AFZ-Full HD IP 10 x Zoom

Modular Terminal Blocks and Terminal Strips with CAGE CLAMP, Series 260 to 262, Side-Entry

Connector System for Fluorescent Lighting Fixtures. Connectors for In-Line Mounting of Fluorescent Lighting Fixtures. Fully Polarized Connectors

MRE Series 16 and 32 Amp Multiple Socket Outlets Stationary and Portable. Increased Safety

LEONARDO MULTIPOWER Quartz Halogen Fresnel Spotlight

Safety switches for hinged doors

Bayonet resistance thermometer Model TR53

Conveyor Belt Alignment Switches from IDEM

Cable Glands. Description Introduction to Cable Glands 399. EEXe Series EEXe Series. A2F, E1FX/E2FX, E1FW/E2FW and T3 Series

Accessories for control enclosures. BERNSTEIN attachment solutions. Double coupling head (console version with suspension system attachment)

4 Remote I/O. Analog Output Module HART Ex i / I.S. Outputs, 8 Channels Series 9466/12

ATX MRE Series 16 and 32 Amp Multiple Socket Outlets Stationary and Portable. Increased Safety

DECONTACTOR METAL 20 A/32 A/63 A/125 A/200 A

Argenta W A L L M O U N T I N G M E T A L C A B I N E T S

Operating Instructions (Translation) 3. Safety Information. 1. Description. 2. Explosion Protection. Supply module Type 17-21BB-170x

Threaded resistance thermometer Miniature design Model TR10-D

Safety switches with manual mechanical delay and separate actuator

westelettric ELECTRICAL RUBBER BOXES

Technical Datasheet. Connectors, Plugs & Sockets. Table of Contents. Selection Guide 2. 16A Range (ELCX ) 3. 32A Range (ELCX

Dräger Polytron 8200 Stationary gas detector (CatEx)

3.2. Ex-d/e Cable Glands Metal Design. For Zone 1, 2, 21 and 22 according EN :2012 / IEC : 2011

Transcription:

> As wall, ceiling and pendant light fitting or pole mounted light fitting > Version with 2 lamps: 18 W and 36 W > Central locking > All-pole disconnection via N/C switch when opening light fitting or battery enclosure > Weekly functional test > Light duration test of the emergency lighting once a year www.stahl.de The lights of the can be used as emergency lighting ATEX / IECEx Zone 0 1 2 20 21 22 For use in x x x x 16126E00 WebCode 6009A Lighting /1

Selection Table Version Lamps Battery Lighting hours Order number Weight W Standard luminaire 2 x 18 7 Ah 1.5 / 3 h (emergency light) 6009/522-9617-1611-71 7.600 Series 6009 2 x 36 7 Ah 1.5 / 3 h (emergency light) 6009/542-9617-1611-71 9.650 Order Number Supplement Through wiring without 6.09/...-.0..-...-.. with 6 conductors 6.09/...-.6..-...-.. ECG 220... 240 V 6.09/...-...7-...-.. 110... 127 V 6.09/...-...6-...-.. Connection terminal Cage clamp terminal type WAGO 0.5... 4 mm 2 6.09/...-...-1...-.. Screw-type terminal type STAHL 1.5... 6 mm 2 6.09/...-...-2...-.. Cable glands Standard 2 x M25 x 1.5 cable gland and 6.09/...-...-..1.-.. 1 x M25 x 1.5 stopping plugs kg Special 2 x M20 x 1,5 cable gland and 1 x M20 x 1,5 stopping plug 6.09/...-...-..2.-.. Emergency duration test with 6.09/...-...-...-7. without 6.09/...-...-...-8. Note The lights are delivered without fluorescent lamps and assembly parts. These parts must be ordered separately! Explosion Protection Global (IECEx) Gas and dust Europe (ATEX) Gas and dust Certifications and certificates Certificates Technical Data Electrical data Rated voltage Rated insulation voltage Disconnection of the light Ex d e mb IIC T4 Gb or Ex db eb mb IIC T4 Ex tb IIIC T80 C Db or Ex tb IIIC T80 C E II 2 G Ex d e mb IIC T4 Gb or Ex db eb mb IIC T4 E II 2 D Ex tb IIIC T80 C Db or Ex tb IIIC T80 C IECEx, ATEX Standard: 220... 240 V ± 10%, 50 / 60 Hz (Lamps acc. IEC60081) Optional: 110... 127 V ± 10%, 50 / 60 Hz (Lamps acc. IEC60081) 120V ± 10%, 50 / 60 Hz (Lamps acc. ANSI IEC C78.81) 320 V When opening the light Switch with safety lock; when opening the central lock, all poles of the voltage supply to the ballast are disconnected; contacts of the switching element are NC contacts, they can only switched on again when the lamp cover and the central locking system are closed. In case of a lamp fault, the electronic ballast disconnects the defective lamp from the power supply. /2 Lighting

Technical Data Luminous characteristics Lamps Measures for light guidance Ambient conditions Ambient temperature 2x 18 W; 2x 36 W (acc. to IEC60081) 2x 17W; 2x 32W (acc. to ANSI IEC C78.81) Standard: wide beam, internal reflector of the light fittings is painted in white colour. Colour: signal white RAL 9003; lateral glare reduction in the luminaire trough. - 30... + 50 C - 20... + 50 C with Breathing Glands 8162-5... + 40 C operationable Mechanical data Degree of protection IP66 / IP67 (IP64 when using the breather 8162) IEC 60598 Protection class I (with internal PE connection) Material Enclosure Enclosure Polyester resin, glass fibre-reinforced Colour colour grey, similar to RAL 7035 Translucent cover Polycarbonate Gasket Silicone foam gasket in the lamp cover Luminaire locking Central locking which can be opened/closed using a socket key M8 / wrench size 13, hinged lamp cover Mounting / Installation Cable glands Standard luminaire Plastic: 2 x M25 x 1.5 cable entries 8161 and 2 x M25 x 1.5 stopping plugs 8290 (enclosed) Metal: 2 x metal plates M20 x 1.5 connected by means of PE for metal cable entries Attention: cable entries must be ordered separately Special: max. 4 drilled holes for M20, M25, NPSM ½ max. 2 drilled holes for NPT ¾ Connection Standard: Special: Metal cable glands: M20 x 1.5, M25 x 1.5; earthing of the metal cable entries by means of metal plates Spring clamp terminals 6-pole: L1, L2, L3, L', N, PE Clamping range: 1 x 0.75... 4 mm 2 (solid / finely stranded) (2 free clamping units per pole available) Terminal block with covering 6-pole: L1, L2, L3, L', N, PE Clamping range: 2 x 1.5... 6 mm 2 (solid); 2 x 1.5... 4 mm 2 (finely and extra finely stranded) Through wiring Through wiring Standard luminaire Luminaires are equipped with internal through wiring. Ingoing and outgoing leads can be connected to the opposite sides. Terminals: see techn. data Wiring cross section: 2.5 mm 2 for max. 16 A. without Optional On the connection side, there are 2 bores M25 x 1.5 for cable entries for ingoing and outgoing wiring of the connection line (ingoing and outgoing leads on one side). Assembly For outdoor mounting a breather is recommended Standard luminaire Standard: 2 x M8 insert nuts in the enclosure Special: Mounting grooves in the enclosure for use of fastening and ceiling rails for variable luminaire mounting (variable mounting distances for luminaires 17 W, 18 W: 320... 480 mm, 32 W, 36 W: 670... 930 mm) Lighting /3

Technical Data Emergency light electronics Emergency light mode Emergency light service time In the emergency light mode, only one lamp is used, which results in reduced light output Battery capacity Emergency light Emergency lighting power service time 17 W; 18 W 32 W; 36 W 7 Ah 1.5 h 100 % 60 % 3.0 h 60 % 30 % Switchover voltage Battery set Version Operating voltage Capacity Replacing the battery set from mains to battery operation for U < 0.74 x U N from battery to mains operation for U > 0.80 x U N Gas-tight NiCd battery 6 V 7 Ah When opening the battery enclosure, the connection between the battery set and the emergency light electronics is disconnected. The battery set can be replaced after disconnecting the plug-in contacts. Accessories and Spare Parts Designation Figure Description Art. no. Weight kg Fluorescent lamps 18 W 1350 Im 108952 0.100 04936E00 36 W 3350 Im 108951 0.200 Two-pin cap d 26 mm Light colour: universal white Pins made of brass Bracket for wall mounting with tube for side entry lamp; with tube, length 400 mm, d 42 mm 108947 2.480 05460E00 Lamp cover for luminaire L=700 222427 0.639 for luminaire L=1310 222428 1.149 for luminaire L=700 (resistant to aromatic substances) 256534 0.639 for luminaire L=1310 (resistant to aromatic substances) 256535 1.149 Lamp-holder Lamp holder G13 1 piece 117252 0.036 05696E00 Switch Switching element 8080/1-3-L, 2 normally closed contacts 132527 0.026 10809E00 Socket key M8 / wrench size 13; to open/close the central locking 222430 0.210 15507E00 /4 Lighting

Accessories and Spare Parts Designation Figure Description Art. no. Weight kg Adapter plates 1 x M20 x 1.5 1 piece 115815 0.070 1 x M25 x 1.5 1 piece 115818 0.070 05755E00 2 x M20 x 1.5 1 piece 2 x M25 x 1.5 1 piece 115826 0.058 115828 0.060 Mounting rail for use together with metal cable glands; the metal cable glands are integrated in the earthing system via adapter plates for a variable mounting distance 222826 0.300 Mounting bracket 15584E00 mounting clamp mounted on a mounting rail for a variable mounting distance 222456 0.400 Pole mounting sleeve 15585E00 for the subsequent mounting on lights 18 W and 36 W, completely with assembly parts 227512 3.200 16985E00 Pipe clamp R 1 1 / 2 222459 1.200 R 1 1 / 4 222458 1.250 R 2 222460 1.300 Ring bolt 15583E00 with mounting rail for a variable mounting distance; Material: stainless steel M8, direct mounting in insert nuts 115736 0.112 05378E00 Breathing gland M25 x 1.5 in order to avoid condensate formation 115738 0.017 05703E00 Ceiling and wallmounting bracket 15586E00 mounted on a mounting rail for a variable mounting distance; Material: stainless steel Lamp can be swiveled in steps of 15 222827 2.400 Battery set for 6409 Battery cover with built-in battery. Gas-tight NiCd battery; 7 Ah / 6 V 223532 1.195 16332E00 Dimensional Drawings (All Dimensions in mm [inches]) - Subject to Alterations 183,5 [7,22] M25 x 1,5 L1 L2 L3 M25 x 1,5 125 [4,92] 16127E00 Lighting /5

Dimensional Drawings (All Dimensions in mm [inches]) - Subject to Alterations Dimensions EXLUX 6009 Luminaire 17/18 W 32/36 W L1 857 [33.74] 1467 [57.76] L2 1) 400 [15.75] 800 [31.50] L3 2) 320... 480 [12.60... 18.90] 1) fixed mounting distance 2) variable mounting distance 670... 930 [26.38... 36.61] Dimensional Drawings for Assembly Parts and Accessories (All Dimensions in mm [inches]) - Subject to Alterations 12 [ 0, 47 ] 18,50 [ 0, 73 ] 30 30,50 [ 1, 20 ] 215 [ 8.46] [1,18]. 9 [0,35] 193-198 [7,60-7,80] 124 [ 4, 88] 11 [ 0, 43] 86 [ 3, 39] 74 [ 2, 91] 32 [1,26] 6,10 [0,24] ø 6,10 ø 8,10 9 [ø. 0, 24] [ø 0,32] [0,35] 13 [0,51] 215 [ 8, 46] 193-198 [7,60. - 7,80]. 143 [5,63] 15778E00 15779E00 Mounting rail ø 20 [ø 0,79] 24 [0,95] ø 42 [ø 1 1/4] ø 48 [ø 1 1/2] ø 60 [ø 2] 162 [6,38] 172 [6,77] 180,50 [1 1/4] 187,50 [1 1/2] 200,50 [2] 15782E00 15781E00 15783E00 Ring bolt fitted in insert nut of the luminaire Mounting bracket fitted in mounting rail Pipe clamp fitted in mounting rail /6 Lighting

Dimensional Drawings for Assembly Parts and Accessories (All Dimensions in mm [inches]) - Subject to Alterations 10x15 A 296 [11,65] 42 [ 1,65] ø 10,50 [ ø 0,41] 15 400 [15,75] A [1,39] 34 65,50-74,50 [2,58-2,93] 110 [4,33] 8,50 [0,35] 8,50 [0,35] Wall mounting bracket fitted in mounting rail 15780E00 198 [7,80] 160 [6,30] 120 [4,72] 143 [5,63] 104 [4,09] 90 130 [5,12] 220 [8,66] SW 5 20 [0,79] 180 [7,09] Bracket for wall mounting with pipe section 03257E00 We reserve the right to make alterations to the technical data, dimensions, weights, designs and products available without notice. The illustrations cannot be considered binding. Lighting /7