Series IZH10. Handheld Electrostatic Meter. How to Order. Accessories and Option / Part Number for Individual Parts.

Similar documents
0.01kV (0 to ±0.99 kv)

High Pressure E/P Regulator. ITVH Series

Controller setting kit Software (ACT Controller)

JXC-W1 (JXC#3 Series)

Product Name. Controller Setting Software (For 3-axis Step Motor Controller) MODEL/ Series/ Product Number. JXC#2 Series

Digital Gap Checker. ON: Placed. Workpiece. Large gap. Workpiece. Workpiece. Small gap. Detection surface Detection nozzle. Air

Electrostatic Sensor Monitor IZE11

Doc. no. LEC-OM00501 PRODUCT NAME. Teaching Box for Electric actuator. MODEL / Series. LEC-T1 Series. Applicable models : For Series LECP, Series LECA

Document No. LEC-OM Product name. LEC Serial Communication Information. Model/ Series. LEC 6 Series. SMC Corporation

Flow Monitor PF2A20# PF2W20# PF2D20#

LEC-T1 Series Applicable models: For Series LECP6,LECPMJ For Series LECA6 For Series LECPA (TB Ver2.1 or more)

OPERATION MANUAL E/P REGULATOR MODEL NAME. Series. For DeviceNet TM CONTENTS. Contents. Safety Instructions. Precautions for Handling P3-4

The importance of the static electric control is put on confirming the actual status.

7032 Digital-Analog Multimeter

EtherNet/IP TM SI unit

Line reactors SINAMICS. SINAMICS G130 Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation

Pressure Sensor Controller PSE300

Fieldbus system (SI unit compatible CompoNet)

INSTALLATION INSTRUCTIONS

TOP - 1. Instruction Manual. Version 1.0 Produced in Jan. 2004

Fan Type Ionizer. IZF10R Series

EF-S1 SERIES. Continuously check invisible static electricity in lines. Constantly check static in lines!

Multi Channel Pressure Sensor Controller PSE200

Emerson Network Power provides customers with technical support. Users may contact the nearest Emerson local sales office or service center.

Ethernet ITV Modbus TCP

Digital Pressure Switch

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions

NJ-Series Power Supply Unit NJ-PA/PD

Line Interactive 1000VA/1400VA/2000VA Uninterruptible Power System

Doc. no. LEC-OM PRODUCT NAME Programless controller (with stroke study) Step motor (servo 24 VDC ) MODEL/ Series LECP2 Series

SoniChek MC. 99 Washington Street Melrose, MA Phone Toll Free TRIPLETT. Mini Sound Level Meter C Weighted

Doc. no.lec-om PRODUCT NAME Programless controller Step motor (servo 24 VDC ) MODEL/ Series LECP1 Series

TPE 1464 Series Pressure Transducer

NPN output. 200 mm. Type Cable length Model Remarks

Handheld Reader Writer

SI unit for IO-Link device

SOLAR POWER METER TM-206. User s Manual HB1TM

Digital Pressure Switch

Primary Injection Test Procedure

H Series PLC. ! : Indicates Compulsion. EH-150 Analog input module EH-AXH8M Instruction manual. Safety precautions DANGER CAUTION COMPULSION

Type MVTT 14 and MVTT 15: Static Digital Time delay relays

SI unit for IO-Link device

Conductive Level Controller

Smart Grid Tie Microinverter User Manual

MIYAWAKI ULTRASONIC TESTER PM11 OPERATOR S MANUAL. Be sure to read this manual for safe and proper operation. Store this manual carefully after use.

Pressure Switch CE40. Digital settings available via IR data communication without actually applying pressure to the unit

Output configuration Contact form Operation indicator Cable length Model PNP open collector. 1 m D5F-2B10 (+ common) ON when operated

D2VW. Sealed Miniature Basic Switch. Ordering Information Model Number Legend D2VW- -

GENERAL PRECAUTIONS GENERAL DESCRIPTION... 6

BatteryCheck USER MANUAL BATTERY MANAGEMENT TECHNOLOGY THAT POWERS YOUR ADVENTURES.

3-step setting 2. 2-Color Display High-Precision Digital Pressure Switch. ZSE30A(F)/ISE30A Series. Added vacuum range.

PRODUCT SPECIFICATION. PC Board Relays. Series.

Supporting Supplement Manual

Line filter SINAMICS. SINAMICS G130 Line filter. Safety information 1. General 2. Mechanical installation 3. Electrical installation 4

LXEM145 SERIES Lanx Australis single Phase KWh Meter 45Amp. User manual

Additional Explanation for A851GOT Graphic Operation Terminal

EtherNet/IP TM Compatible Fieldbus System

Option 2. Nil. Note 1) Option 1. Note With waterproof seal and mounting screw. With waterproof seal and mounting screw. 48 conversion adapter

SDM120 SERIES. SDM120 series User Manual. Single phase two wire DIN rail energy meter (One module)

Making Hazardous Operations Safe and Productive

DM-918 OPERATIONS MANUAL AUTORANGING MULTIMETER

Differential Liquid/Gas Pressure Transmitter

Model P4017 Single Channel USB Oscilloscope. Quick Start Guide

Instruction book IQAN-LST. Publ no HY /UK Edition 0301

Instruction Manual MINI CALIBRATOR MC-20

Model NPN output PNP output Standard. configuration

22-60VDC Grid Tie Microinverter User Manual

EM-F-7G Safety Extension Module

SAVE THESE INSTRUCTIONS

No.EX##-OMN0028. Fieldbus system PROFIBUS DP compatible SI unit PRODUCT NAME. EX600-SPR#A EX600-ED# MODEL/ Series

User Manual AIMB-C200. Economical Embedded Chassis for Mini-ITX Motherboard

No.EX##-OMN0036. Fieldbus system Digital unit PRODUCT NAME. EX600-DX## EX600-DY## EX600-DM## MODEL/ Series

Model VC-SHIELD Shield Box

User Manual IDS-3206 Series. 6.5" Industrial Panel Mount Monitor

Installation and Maintenance Instructions for GC55 Differential Pressure Transducer Version 1.0 5/11

Operation Manual. Fieldbus system EX510-GDN1. DeviceNet Compatible GW unit

EC Series. Safety Guide

MT1810A 4 Slot Chassis Operation Manual

E2K-F. Flat Capacitive Sensor with a Thickness of Only 10 mm. Flat Proximity Sensor. Ordering Information. Sensors [Refer to Dimensions on page 4.

Model Number Structure

No.EX##-OMN0034. Fieldbus system CC-Link compatible SI unit PRODUCT NAME. EX600-SMJ# EX600-ED# MODEL/ Series

No.EX##-OMN0030-A. Fieldbus system DeviceNet TM compatible SI unit PRODUCT NAME. EX600-SDN#A EX600-ED# MODEL/ Series

SIRIUS CAPACITOR MODULE User Manual. Model number: A-1.7C-M-SD-G Version 1.0; Release Date: April 2018

SUN2000P-375 W Smart PV Optimizer. User Manual. Issue 01. Date HUAWEI TECHNOLOGIES CO., LTD.

User Manual IDS-3106 Series. 6.5" Industrial Open Frame Monitor

Remote access to status, test and reset functions. Built-in diagnostic indicators. Options Lid-mounted reset key switch (MC4)

Model Number Structure

Operation Manual. Fieldbus system EX510-GPR1. PROFIBUS DP Compatible GW unit

INSTRUCTION MANUAL TRIP CIRCUIT SUPERVISION RELAY GKAD1

D5B. Detects Objects in Multiple Directions with High Sensitivity, Ideal for Robotics. Mechanical Touch Switch. Model Number Structure

Suitable for detecting transparent films or transparent bottles

Precautions. Please read carefully before using this product.

Thank you for purchasing the CHP Assembly Tool. In order to ensure maximum performance and

Operating instructions Enabling switch (handle switch) ZSD5 ZSD6. 1. About this document. Content. 7 Appendix 7.1 Wiring example...

SS Series Compatible Mounting with a Simple Construction and Easy-to-Use Design Concept

External level devices for conductive point level switch

GREISINGER electronic GmbH D Regenstauf, Hans-Sachs-Straße 26

Instruction book IQAN-LSL. Publ no HY /UK Edition 0301

Ultra Slim Relays 24

Timers NEW DESIGN! RTE Series. RTE Series Analog Timers

Transcription:

Peak G 15min Handheld Electrostatic Meter Series IZH10 How to Order IZH10 Option Nil H None High-voltage measuring handle Accessories and Option / Part Number for Individual Parts The ground wire and soft case are attached to the IZH series. Ground wire (1.5 m) / Accessories IZH-A-01 Soft case / Accessories IZH-B-01 High-voltage measuring handle / Option IZH-C-01 Measured Potential Press for 6sec AUTO -OFF Extension Press! Press! PEAK / BOTTOM MODE Display Normal Bottom BATTERY 1.5V x 2 LR6 MADE IN JAPAN ±20.0kV Extends at Ground wire High-voltage measuring handle Soft case Note) Be sure to use a high-voltage measuring handle in situations such as during highvoltage measurement when there is a possibility of personnel coming in contact with electricity. Specifications Model Rated charge amount range Minimum display unit Measurement distance Power supply Note 1) Display accuracy Environmental resistance Enclosure Operating temperature range Operating humidity range Vibration resistance Material Mass Standards Accessories Note 1) 2A alkali dry cell batteries are not included, and must be acquired separately. Note 2) When new alkali dry cell batteries are used at ordinary temperature. 1100 Impact resistance IZH10 ±20.0 kv 0.1 kv (±1.0 kv to ±20.0 kv), 0.01 kv (0 to ±0.99 kv) 50 mm (between sensor part and measured target) 1.5 VDC 2A alkali dry cell battery, 2 pcs (continuous use for 15 hours or more, see Note 2) ) ±5% F.S. ±1 digit IP40 Operating: 0 to 40 C, Stored: 10 to 60 C (with no freezing or condensation) Operating/Stored: 35 to 85% R.H. (with no condensation) 10 to 150 Hz at whichever is smaller of 1.5 mm amplitude or 98 m/s 2 acceleration, in X, Y, Z directions for 2 hs. each (De-energized) 100 m/s 2 in X, Y, Z directions 3 times each (De-energized) Display part: PC/ABS Sensor part: ABS 85 g (excluding dry cell batteries) CE marking Ground wire, Soft case

Normal Press! Peak Extends at 15min Press! Bottom Handheld Electrostatic Meter Series IZH10 Dimensions (Unit: mm) Display part 40 20 Measured Potential ±20.0kV AUTO -OFF Extension Press for 6sec PEAK / BOTTOM MODE Display kv BATTERY 1.5V x 2 LR6 MADE IN JAPAN G LIGHT 2 x ø3.4 600 16.6 9 SMC 110 Do not apply a strong impact on the sensing part. Sensor part 87.5 ø4.8 13 0.5 8.8 6.5 7 (7.5) (175) IZS IZD IZE IZH (12.3) 60 21 (9.3) (55) 86 1101

Press! Normal Peak Extends at 15min Press! Bottom Series IZH10 Names and Functions of Individual Parts Peak display P Bottom display b LCD display Display of charged electricity Display of peak/bottom value Measured Potential ±20.0kV AUTO -OFF Extension Press for 6sec kv Ground terminal PEAK / BOTTOM MODE Display BATTERY 1.5V x 2 LR6 MADE IN JAPAN G Battery LOW L button Power ON/OFF Mode switching LIGHT LIGHT button Backlight ON/OFF LR6 dry cell battery (2 pcs) Function Details A Peak/Bottom display function The function constantly detects and updates the maximum and minimum electrostatic potential value and allows holding the display value. B Reset function The reading of the measured voltage can be adjusted to zero. The reading can be corrected within ±5% of F.S. from the factory-set condition. C LOW battery indicator When the batteries are low it is displayed in two stages: Battery LOW and Replace Battery. The battery level is indicated by the flashing or lightening up of on the display. flashes: Prepare to replace batteries. lights up: Replace batteries with new ones. D Auto power-off function If no button is operated for 5 min. or more while the power supply is on, the power supply will turn off automatically. When the [] button is pressed for 6 sec. or more with the power supply off, continuous operating time while no button is pushed will extend to 15 min. E Light-up of backlight The display can be easily seen in the dark. The backlight will be turned on and off by every press of the [LIGHT] button. F Displayed digit change function The minimum display digit is changed for the charged potential between 0.99 kv to +0.99 kv. Error Display Error description Error display Condition Zero clear error A charge over ±5% F.S. of default potential is applied to the sensor. The indication lasts approx. 1 sec. and then measurement mode returns automatically. There will be a slight displacement, depending on the deviation of the sensor itself and ambient environment. Sensor error System error Measurement error Cable breakage The sensor breaks. Internal display error. A charge over the upper limit of the measured voltage range is applied to the sensor, or the distance to the measured target is outside of specified range. A charge over the lower limit of the measured voltage range is applied to the sensor, or the distance to the measured target is outside of specified range. A broken cable prevents accurate measurement. The charge amount can be detected, but it will not change the displayed value. 1102

Series IZH10 Handheld Electrostatic Meter Precautions Be sure to read this before handling. Refer to front matters 58 and 59 for Safety Instructions. Warning Handling Precautions 1. Do not make any modifications (including exchanging the printed circuit board) to the product. It may cause human injuries and damage. 2. Use the device in the condition of specified range. Using it out of the specified range may result in fires, electric shock, or damage. Confirm the specifications before using. 3. Measurement near high-voltage Avoid measuring near high-voltage exceeding specifications as it can be dangerous. 4. Handling of ground wire Be sure to provide a ground wire to ensure safety and highaccuracy measurement when using the sensor. Also, if the ground wire is not connected properly, the power is pooled in the sensor part and/or ground terminal, which can discharge to an operator s hand. Handle the sensor part and ground terminal carefully. If grounding is not provided, Measurement accuracy gets worse. The sensor is charged and can discharge to an operator s hand. 5. Do not apply strong impact. Do not drop, allow collision or apply excessive shock to the sensor when handling. It can result in damage of the sensor and accidents. 6. Distance measurement is 50 mm. Use display of label attached to the sensors as a guide. Warning Operating Environment 1. Handheld electrostatic meters are CE marked; however, they are not equipped with surge protection against lighting. Lighting surge countermeasures should be applied directly to system components as necessary. 2. Handheld electrostatic meters do not have an explosion proof rating. Never use in the presence of an explosive gas as this may cause a serious explosion. Approx. 50 mm Distance measurement Detection area Detection hole 7. The measurement of a part with a high-charge potential can be highly dangerous as it can cause a discharge to the user s hand. In this case, use a handle specific for measuring high voltage, which is available as an option, and wear rubber gloves, etc. Also, gradually bring the sensor part close to the measured target from a distance, and stop the measurement immediately when the displayed value overflows (HHH) or underflows (LLL). (A target with a high-charge potential is very dangerous. The measured value does not changed even if the distance is shortened.) IZS IZD IZE IZH 1103

Safety Instructions These safety instructions are intended to prevent hazardous situations and/or equipment damage. These instructions indicate the level of potential hazard with the labels of Caution, Warning or Danger. They are all important notes for safety and must be followed in addition to International Standards (ISO/IEC), Japan Industrial Standards (JIS) 1) and other safety regulations 2). 1) ISO 4414: Pneumatic fluid power General rules relating to systems. ISO 4413: Hydraulic fluid power General rules relating to systems. IEC 60204-1: Safety of machinery Electrical equipment of machines. (Part 1: General requirements) ISO 10218-1992: Manipulating industrial robots -Safety. JIS B 8370: General rules for pneumatic equipment. JIS B 8361: General rules for hydraulic equipment. JIS B 9960-1: Safety of machinery Electrical equipment of machines. (Part 1: General requirements) JIS B 8433-1993: Manipulating industrial robots - Safety. etc. 2) Labor Safety and Sanitation Law, etc. Caution: Operator error could result in injury or equipment damage. Warning: Operator error could result in serious injury or loss of life. Danger : In extreme conditions, there is a possibility of serious injury or loss of life. Warning 1. The compatibility of the product is the responsibility of the person who designs the equipment or decides its specifications. Since the product specified here is used under various operating conditions, its compatibility with specific equipment must be decided by the person who designs the equipment or decides its specifications based on necessary analysis and test results. The expected performance and safety assurance of the equipment will be the responsibility of the person who has determined its compatibility with the product. This person should also continuously review all specifications of the product referring to its latest catalog information, with a view to giving due consideration to any possibility of equipment failure when configuring the equipment. 2. Only personnel with appropriate training should operate machinery and equipment. The product specified here may become unsafe if handled incorrectly. The assembly, operation and maintenance of machines or equipment including our products must be performed by an operator who is appropriately trained and experienced. 3. Do not service or attempt to remove product and machinery/equipment until safety is confirmed. 1. The inspection and maintenance of machinery/equipment should only be performed after measures to prevent falling or runaway of the driven objects have been confirmed. 2. When the product is to be removed, confirm that the safety measures as mentioned above are implemented and the power from any appropriate source is cut, and read and understand the specific product precautions of all relevant products carefully. 3. Before machinery/equipment is restarted, take measures to prevent unexpected operation and malfunction. 4. Contact SMC beforehand and take special consideration of safety measures if the product is to be used in any of the following conditions. 1. Conditions and environments outside of the given specifications, or use outdoors or in a place exposed to direct sunlight. 2. Installation on equipment in conjunction with atomic energy, railways, air navigation, space, shipping, vehicles, military, medical treatment, combustion and recreation, or equipment in contact with food and beverages, emergency stop circuits, clutch and brake circuits in press applications, safety equipment or other applications unsuitable for the standard specifications described in the product catalog. 3. An application which could have negative effects on people, property, or animals requiring special safety analysis. 4. Use in an interlock circuit, which requires the provision of double interlock for possible failure by using a mechanical protective function, and periodical checks to confirm proper operation. Front matter 58

Safety Instructions Caution The product is provided for use in manufacturing industries. The product herein described is basically provided for peaceful use in manufacturing industries. If considering using the product in other industries, consult SMC beforehand and exchange specifications or a contract if necessary. If anything is unclear, contact your nearest sales branch. Limited Warranty and Disclaimer/Compliance Requirements The product used is subject to the following Limited Warranty and Disclaimer and Compliance Requirements. Read and accept them before using the product. Limited Warranty and Disclaimer 1. The warranty period of the product is 1 year in service or 1.5 years after the product is delivered. 3) Also, the product may have specified durability, running distance or replacement parts. Please consult your nearest sales branch. 2. For any failure or damage reported within the warranty period which is clearly our responsibility, a replacement product or necessary parts will be provided. This limited warranty applies only to our product independently, and not to any other damage incurred due to the failure of the product. 3. Prior to using SMC products, please read and understand the warranty terms and disclaimers noted in the specified catalog for the particular products. 3) Vacuum pads are excluded from this 1 year warranty. A vacuum pad is a consumable part, so it is warranted for a year after it is delivered. Also, even within the warranty period, the wear of a product due to the use of the vacuum pad or failure due to the deterioration of rubber material are not covered by the limited warranty. Compliance Requirements When the product is exported, strictly follow the laws required by the Ministry of Economy, Trade and Industry (Foreign Exchange and Foreign Trade Control Law). Front matter 59