Bauart gepruft Sicherheit egelma ge od o s be wac g www. tuv.com ID 00000000 Rack System U Profile 9" Rack Shelf Supports Hot Swap 000~3000W MEAN WELL RCP-U Rack System (Fits 3 RCP-000 Hot Swap PSU) Providing exceptional customer service since 982 - File Name:RCP-U Rack SystemPEC 7-07-4.888.62.954
Rack System U Profile 9 Rack Shelf Supports Hot Swap 000~3000W MEAN WELL RCP-U Rack System (Fits 3 RCP-000 Hot Swap PSU) Providing exceptional customer service since 982 SPECIFICATION - Power Supply System MODEL RCP-3KU -2 RCP-3KU -24 RCP-3KU -48 RECTIFIER RCP-000-2 RCP-000-24 RCP-000-48 RACK SHELF RCP-UI or RCP-UT OUTPUT OUTPUT VOLTAGE 2V 24V 48V MAX. OUTPUT CURRENT 80A A 63A MAX. OUTPUT POWER Note.6 260W 2880W 3024W VOLTAGE RANGE Note.5 90 ~ 264VAC 27 ~ 370VDC INPUT FREQUENCY RANGE 47 ~ 63Hz AC CURRENT (Typ.)PER MODULE 8.5A/5VAC 4.5A/230VAC 0.5A/5VAC 5.5A/230VAC A/5VAC 5.5A/230VAC LEAKAGE CURRENT <3.5mA / 230VAC AUXILIARY POWER 5V @ 0.3A REMOTE ON-OFF CONTROL By electrical signal or dry contact ON:short OFF:open REMOTE SENSE Compensate voltage drop on the load wiring up to 0.5V. FUNCTION OUTPUT VOLTAGE PROGRAMMABLE Adjustment of output voltage is allowable to 90 ~ 0% of nominal output voltage. Please refer to the Function Manual. DC OK SIGNAL The isolated TTL signal out, Please refer to the Installation Manual AC OK SIGNAL The isolated TTL signal out, Please refer to the Installation Manual OVER TEMP WARNING Logic " High" for over temperature warning, Please refer to the Installation Manual, isolated signal ENVIRONMENT WORKING TEMP. WORKING HUMIDITY STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION - ~ +60 (Refer to "Derating Curve") ~ 90% RH non-condensing -40 ~ +85, 0 ~ 95% RH non-condensing ± 0.02%/ (0 ~ 50 ) 0 ~ 500Hz, 2G 0min./cycle, 60min. each along X, Y, Z axes SAFETY STANDARDS UL60950-, TUV EN60950- approved WITHSTAND VOLTAGE I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.7KVDC ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:00M Ohms / 500VDC / / 70% RH Parameter Standard Test Level / Note SAFETY & EMC (Note 4) OTHERS NOTE EMC EMISSION EMC IMMUNITY Conducted Radiated Harmonic Current Voltage Flicker EN55024, EN64-3, EN6000-6-2 Parameter ESD Radiated EFT / Burst Surge Conducted Magnetic Field Voltage Dips and Interruptions DIMENSION Rack 483.6*350.8*44(L*W*H) PACKING 3.2Kg; pcs/3.2kg/2.67cuft EN55032 (CISPR32) / EN550 (CISPR) Class B EN55032 (CISPR32) / EN550 (CISPR) Class B EN6000-3-2 ----- EN6000-3-3 ----- Standard EN6000-4-2 EN6000-4-3 EN6000-4-4 EN6000-4-5 EN6000-4-6 EN6000-4-8 EN6000-4- Test Level / Note Level 3, 8KV air ; Level 2, 4KV contact Level 3 Level 3 Level 4, 4KV/Line-Earth ; Level 3, 2KV/Line-Line Level 3 Level 4 >95% dip 0.5 periods, 30% dip periods, >95% interruptions 0 periods File Name:RCP-U Rack SystemPEC 7-07-4.888.62.954
Rack System U Profile 9 Rack Shelf Supports Hot Swap 000~3000W MEAN WELL RCP-U Rack System (Fits 3 RCP-000 Hot Swap PSU) Providing exceptional customer service since 982 Function Manual. Remote ON/OFF Control The PSU can be turned ON/OFF together or separately by using the "Remote ON-OFF" function. RCP-U System Remote ON-OFF A 8 Remote ON-OFF A 8 Remote ON-OFF B 5 Remote ON-OFF B 5 Remote ON-OFF C RCP-U Remote ON-OFF C System 2 2 Between Remote ON-OFF and Switch Open Switch Short Output OFF ON 2. Voltage Drop Compensation 2. Remote Sense The remote sense compensates voltage drop on the load wiring up to 0.5V. RCP-U System 2 LOAD Sense lines should be twisted in pairs 2.2 Local Sense Notice : The,, on CN500 have to be connected to the, terminals locally in order to get the correct output voltage if the remote sensing is not used. RCP-U System 2 3. Output Voltage Programming (or, PV / remote voltage programming / remote adjust / margin programming / dynamic voltage trim) ()Output voltage can be trimmed between 90~0% of its rated value by the following method. (2) &, & also need to be connected on CN500. RCP-U System V-TRIM-A V-TRIM-B V-TRIM-C 4 8 2 R R R R2 R2 R2 LOAD 3. RCP-000-2 00 0 98 08 96 06 94 04 92 02 90 00 80K 240K 350K 560K.2M NC R ( Ω) min. 0.W NC 300K K 62K 3K 3K R2 ( Ω) min. 0.W File Name:RCP-U Rack SystemPEC 7-07-4.888.62.954
Rack System U Profile 9 Rack Shelf Supports Hot Swap 000~3000W MEAN WELL RCP-U Rack System (Fits 3 RCP-000 Hot Swap PSU) Providing exceptional customer service since 982 3.2 RCP-000-24 00 98 96 94 92 0 08 06 04 02 90 00 560K 750K M.6M 3.3M NC R ( Ω) min. 0.W NC 330K 30K 62K 30K 0K R2 ( Ω) min. 0.W 3.3 RCP-000-48 00 0 98 08 96 06 94 04 92 02 90 00.3M.7M 2.4M 3.6M 7.6M NC R ( Ω) min. 0.W NC 345K 40K 70K 36K 5K R2 ( Ω) min. 0.W 2 4. I C Bus Interface Option For the details of I C option, please refer to the Installation Manual. File Name:RCP-U Rack SystemPEC 7-07-4.888.62.954
Providing exceptional customer service since 982 Rack System U Profile 9 Rack Shelf Supports Hot Swap 000~3000W MEAN WELL RCP-U Rack System (Fits 3 RCP-000 Hot Swap PSU) 000 ~ 3000W U Distributed Power System RCP-U Rack System Mechanical Specification (Rack System) Case No. 959A Unit:mm Fig 4 3 ADDRESS SWITCH - + CN500 4 RCP-UT LC NC LB NB LA NA 3 Mounting Bracket 0 8 ADDRESS SWITCH C B A + - 4 CN500 RCP-UI 3 440 50 3-M5 L=6mm 350.8 3-M5 L=6mm 50 24 Air flow direction Module C Module B Module A 44 7. 0.6 3.8 DC OK AC OK DC OK AC OK DC OK AC OK 466.2 6. 483.6 Mounting Instruction Hole No. Recommended Screw Size MAX. Penetration Depth L Recommended mounting torque M5 6mm 0Kgf-cm Mounting Surface Mounting Screw Chassis of RCP-U RACK L.888.62.954 File Name:RCP-U Rack SystemPEC 7-07-4
Rack System U Profile 9 Rack Shelf Supports Hot Swap 000~3000W MEAN WELL RCP-U Rack System (Fits 3 RCP-000 Hot Swap PSU) Providing exceptional customer service since 982 IN/OUT Connector Pin No. Assignment( CN500) : D-Type Right Angle positions(female type) 4 3 Pin No. Function Description,8,5 2,9,6 3,0,7 4,,8 5,2,9 RemoteON-OFF AC-OK DC-OK V-TRIM T-ALARM Each unit can separately turn the output on and off by electrical or dry contact between Remote ON-OFF A,B,C(pin,8,5) and (pin 2). Short: ON, Open:OFF. Low : When input voltage is 82Vrms +/-4V. High : When input voltage in 82Vrms +/-4V. High : When Vout 80%+/-5%. Low : When Vout 80%+/-5% Connection for output voltage programming. High : When the internal temperature is within safe limit. Low : 0 below the thermal shut down limit. 6 +5V-AUX Auxiliary voltage output, 4.3~5.3V, referenced to GND-AUX(pin 7). The maximum load current is 0.3A. This output has the built-in "Oring diodes" and is not controlled by the remote ON/OFF control. 7 GND-AUX Auxiliary voltage output GND. The signal return is isolated from the output terminals ( & ). 4 CS Current sharing signal. When units are connected in parallel, the CS pins of the units should be connected to allow current balance between units. 2 Positive sensing for Remote Sense. Negative sensing for Remote Sense. Positive output voltage. 23 SCL Serial clock used in the I C interface option. Refer to the Instruction Manual. 24 SDA Serial data used in the I C interface option. Refer to the Instruction Manual. Negative output voltage. File Name:RCP-U Rack SystemPEC 7-07-4.888.62.954